Search criteria
3 vulnerabilities found for t301_firmware by ruckuswireless
FKIE_CVE-2017-6229
Vulnerability from fkie_nvd - Published: 2018-02-14 19:29 - Updated: 2024-11-21 03:29
Severity ?
Summary
Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:r500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7842F7BA-DB75-44BA-A505-03AC07443F55",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:r500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9BBDBE9C-BE4B-4ED6-AF62-8FE484C519E2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:r600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01AEB940-2D3C-4F8A-B2D2-075665F893EC",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:r600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5421B1D7-E630-4BDA-BA34-7DD8D0738DF4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:r310_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "08795F10-C276-4A7D-83FD-C39A8844D854",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:r310:-:*:*:*:*:*:*:*",
"matchCriteriaId": "40D3129E-4C02-484F-96B6-59D76F787D21",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:h320_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B282766-1ACE-4249-99CB-CF8DD099EBDC",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:h320:-:*:*:*:*:*:*:*",
"matchCriteriaId": "282C3A1D-711C-4415-B9BE-A9B518204AEB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:h510_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01348379-0624-46A2-B0EF-8877A6CBB8B6",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:h510:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CB1FAB48-786A-4FB3-AB6D-3118E94E68C7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:r710_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61041E50-BDB8-431E-959F-BA6BF734F889",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:r710:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E95884E9-C6AF-4106-A178-9274AD27EF65",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:r720_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F40E9FA2-CAD7-43E4-AACC-6E61B5D3B41C",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:r720:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DDFDAF0A-9F5D-4E34-805E-6F27103AAA32",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:t300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACA58F89-2F73-42A6-AF00-BD17275650EA",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:t300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0511674E-59A6-427C-A265-B277D84DE301",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:t301_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F5B07FA9-7E5A-4429-A4F6-B2AD1AB89388",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:t301:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7FFEA172-9781-4FA8-96F2-DE09FB6340FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:t300e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3FAD7213-2C06-4B24-8E36-9D5EE2B32720",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:t300e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "787156EB-F6AA-445F-8B56-4C3696E08697",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:t610_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0395ED7F-AE77-4FF3-A139-718956FA13A7",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:t610:-:*:*:*:*:*:*:*",
"matchCriteriaId": "210D55AB-9305-4D0B-B9F0-47889D37373B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:t710_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A02D3DD9-5369-45E4-84BE-678EC3DDDAC4",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:t710:-:*:*:*:*:*:*:*",
"matchCriteriaId": "862672CC-0480-405C-9791-8993D19931A2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:r510_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6248C61C-ED6C-42AC-8B0D-DF197BF1107D",
"versionEndExcluding": "200.6.10.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:r510:-:*:*:*:*:*:*:*",
"matchCriteriaId": "80B2E8CC-EACE-4A80-9EB1-DADAB8034415",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA60F3C8-CF88-4336-A214-98292E45B39D",
"versionEndIncluding": "9.10.2.0.53",
"versionStartIncluding": "9.10.2.0.11",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "87A7791C-AD3E-433E-9383-69BCC6F1A91F",
"versionEndIncluding": "9.12.3.0.83",
"versionStartIncluding": "9.12.3.0.28",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "882D995A-9677-46BD-BF59-91DDAA4C73F6",
"versionEndIncluding": "9.13.3.0.145",
"versionStartIncluding": "9.13.3.0.22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AB97CF78-F5A4-4BEE-B447-4E27CE05022B",
"versionEndIncluding": "10.0.1.0.44",
"versionStartIncluding": "10.0.1.0.17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:10.1.0.0.1515:*:*:*:*:*:*:*",
"matchCriteriaId": "E832AD5B-50F7-4BB1-9116-33B67286D197",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:zonedirector_1200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0FE0C2B2-D14B-4798-95C4-F911B3B1D88E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3DBB4B6-0ED3-425A-AB4A-B8B76521312F",
"versionEndIncluding": "9.10.2.0.53",
"versionStartIncluding": "9.10.2.0.11",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "77C9E693-D648-4636-97E0-62B819DDB9CB",
"versionEndIncluding": "9.12.3.0.83",
"versionStartIncluding": "9.12.3.0.28",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC11B771-8CB6-4009-861F-0AC6CA0519C1",
"versionEndIncluding": "9.13.3.0.145",
"versionStartIncluding": "9.13.3.0.22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "26F9F52E-11E2-4995-AA03-F0AC4F33D0C9",
"versionEndIncluding": "10.0.1.0.44",
"versionStartIncluding": "10.0.1.0.17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:10.1.0.0.1515:*:*:*:*:*:*:*",
"matchCriteriaId": "A8636729-51EA-4292-8477-C78C11C5A8AC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ruckuswireless:zonedirector_3000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5A1F42A8-8785-48A5-B0B0-68504EFD38B9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems."
},
{
"lang": "es",
"value": "Ruckus Networks Unleashed AP, en versiones de firmware anteriores a 200.6.10.1.x y Ruckus Networks Zone Director, en versiones de firmware 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x y 10.0.1.0.x o anteriores, contienen inyecci\u00f3n de comandos root autenticados en la interfaz de l\u00ednea de comandos que podr\u00edan permitir que usuarios autenticados v\u00e1lidos ejecuten comandos privilegiados en los respectivos sistemas."
}
],
"id": "CVE-2017-6229",
"lastModified": "2024-11-21T03:29:18.477",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-02-14T19:29:00.213",
"references": [
{
"source": "sirt@brocade.com",
"tags": [
"Vendor Advisory"
],
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
],
"sourceIdentifier": "sirt@brocade.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2017-6229 (GCVE-0-2017-6229)
Vulnerability from cvelistv5 – Published: 2018-02-14 19:00 – Updated: 2024-09-16 23:55
VLAI?
Summary
Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems.
Severity ?
No CVSS data available.
CWE
- Authenticated command injection in CLI interface of ZD/Unleashed software.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Brocade Communications Systems, Inc. | Ruckus Networks Unleashed APs and Zone Director |
Affected:
Unleashed AP firmware releases before 200.6.10.1.x and ZD firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x,9.13.3.0.x, 10.0.1.0.x or before
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:25:48.601Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ruckus Networks Unleashed APs and Zone Director",
"vendor": "Brocade Communications Systems, Inc.",
"versions": [
{
"status": "affected",
"version": "Unleashed AP firmware releases before 200.6.10.1.x and ZD firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x,9.13.3.0.x, 10.0.1.0.x or before"
}
]
}
],
"datePublic": "2018-02-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authenticated command injection in CLI interface of ZD/Unleashed software.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-02-14T18:57:02",
"orgId": "87b297d7-335e-4844-9551-11b97995a791",
"shortName": "brocade"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "sirt@brocade.com",
"DATE_PUBLIC": "2018-02-09T00:00:00",
"ID": "CVE-2017-6229",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ruckus Networks Unleashed APs and Zone Director",
"version": {
"version_data": [
{
"version_value": "Unleashed AP firmware releases before 200.6.10.1.x and ZD firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x,9.13.3.0.x, 10.0.1.0.x or before"
}
]
}
}
]
},
"vendor_name": "Brocade Communications Systems, Inc."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authenticated command injection in CLI interface of ZD/Unleashed software."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt",
"refsource": "CONFIRM",
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
"assignerShortName": "brocade",
"cveId": "CVE-2017-6229",
"datePublished": "2018-02-14T19:00:00Z",
"dateReserved": "2017-02-23T00:00:00",
"dateUpdated": "2024-09-16T23:55:41.500Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6229 (GCVE-0-2017-6229)
Vulnerability from nvd – Published: 2018-02-14 19:00 – Updated: 2024-09-16 23:55
VLAI?
Summary
Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems.
Severity ?
No CVSS data available.
CWE
- Authenticated command injection in CLI interface of ZD/Unleashed software.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Brocade Communications Systems, Inc. | Ruckus Networks Unleashed APs and Zone Director |
Affected:
Unleashed AP firmware releases before 200.6.10.1.x and ZD firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x,9.13.3.0.x, 10.0.1.0.x or before
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:25:48.601Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Ruckus Networks Unleashed APs and Zone Director",
"vendor": "Brocade Communications Systems, Inc.",
"versions": [
{
"status": "affected",
"version": "Unleashed AP firmware releases before 200.6.10.1.x and ZD firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x,9.13.3.0.x, 10.0.1.0.x or before"
}
]
}
],
"datePublic": "2018-02-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authenticated command injection in CLI interface of ZD/Unleashed software.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-02-14T18:57:02",
"orgId": "87b297d7-335e-4844-9551-11b97995a791",
"shortName": "brocade"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "sirt@brocade.com",
"DATE_PUBLIC": "2018-02-09T00:00:00",
"ID": "CVE-2017-6229",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ruckus Networks Unleashed APs and Zone Director",
"version": {
"version_data": [
{
"version_value": "Unleashed AP firmware releases before 200.6.10.1.x and ZD firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x,9.13.3.0.x, 10.0.1.0.x or before"
}
]
}
}
]
},
"vendor_name": "Brocade Communications Systems, Inc."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authenticated command injection in CLI interface of ZD/Unleashed software."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt",
"refsource": "CONFIRM",
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-20180202-v1.0.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
"assignerShortName": "brocade",
"cveId": "CVE-2017-6229",
"datePublished": "2018-02-14T19:00:00Z",
"dateReserved": "2017-02-23T00:00:00",
"dateUpdated": "2024-09-16T23:55:41.500Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}