Search criteria
18 vulnerabilities found for tapo by tp-link
FKIE_CVE-2023-27098
Vulnerability from fkie_nvd - Published: 2024-01-09 02:15 - Updated: 2025-06-18 17:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
TP-Link Tapo APK up to v2.12.703 uses hardcoded credentials for access to the login panel.
References
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:tapo:*:*:*:*:*:android:*:*",
"matchCriteriaId": "C9EB199F-FE2B-4E4B-B74E-C6B0A2D55AA7",
"versionEndExcluding": "2.11.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:tapo_c200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91B3D3B3-6E31-4F14-8DF5-0E3519C29DFD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "TP-Link Tapo APK up to v2.12.703 uses hardcoded credentials for access to the login panel."
},
{
"lang": "es",
"value": "TP-Link Tapo APK hasta v2.12.703 utiliza credenciales codificadas para acceder al panel de inicio de sesi\u00f3n."
}
],
"id": "CVE-2023-27098",
"lastModified": "2025-06-18T17:15:26.690",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-01-09T02:15:44.113",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "http://tp-lin.com"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "http://tp-link.com"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/c0d3x27/CVEs/tree/main/CVE-2023-27098"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/support/contact-technical-support/#LiveChat-Support"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "http://tp-lin.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "http://tp-link.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/c0d3x27/CVEs/tree/main/CVE-2023-27098"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/support/contact-technical-support/#LiveChat-Support"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-34829
Vulnerability from fkie_nvd - Published: 2023-12-28 03:15 - Updated: 2025-04-17 21:15
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/SecureScripts/TP-Link_Tapo_Hack | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/SecureScripts/TP-Link_Tapo_Hack | Exploit, Third Party Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:tapo:*:*:*:*:*:*:*:*",
"matchCriteriaId": "72827595-F645-4D2C-BDFA-F211C1994100",
"versionEndExcluding": "3.1.315",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext."
},
{
"lang": "es",
"value": "El control de acceso incorrecto en TP-Link Tapo anterior a v3.1.315 permite a los atacantes acceder a las credenciales de usuario en texto plano."
}
],
"id": "CVE-2023-34829",
"lastModified": "2025-04-17T21:15:46.723",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-12-28T03:15:07.587",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/SecureScripts/TP-Link_Tapo_Hack"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/SecureScripts/TP-Link_Tapo_Hack"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-38907
Vulnerability from fkie_nvd - Published: 2023-09-25 23:15 - Updated: 2024-11-21 08:14
Severity ?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | tapo_l530e_firmware | 1.0.0 | |
| tp-link | tapo_l530e | - | |
| tp-link | tapo | 2.8.14 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:tapo_l530e_firmware:1.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "0427C4E5-322A-40F0-AA88-2FF57A32885F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:tapo_l530e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49091A2E-84FF-4A44-87EE-2BA8C366BE51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:tapo:2.8.14:*:*:*:*:*:*:*",
"matchCriteriaId": "D392C8A7-8A3F-490A-90B5-F7D7BFDC7F72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
},
{
"lang": "es",
"value": "Un problema en TPLink Smart bulb TPLink Tapo series L530 v.1.0.0 y Tapo Application v.2.8.14 permite a un atacante remoto obtener informaci\u00f3n sensible a trav\u00e9s de la clave de sesi\u00f3n en la funci\u00f3n de mensaje."
}
],
"id": "CVE-2023-38907",
"lastModified": "2024-11-21T08:14:25.267",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-09-25T23:15:09.543",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Technical Description",
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "cve@mitre.org",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "cve@mitre.org",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description",
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-38909
Vulnerability from fkie_nvd - Published: 2023-08-22 01:15 - Updated: 2024-11-21 08:14
Severity ?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://arxiv.org/abs/2308.09019 | Third Party Advisory | |
| cve@mitre.org | https://arxiv.org/pdf/2308.09019.pdf | Exploit, Technical Description, Third Party Advisory | |
| cve@mitre.org | https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/ | ||
| cve@mitre.org | https://www.scitepress.org/Papers/2023/120929/120929.pdf | ||
| cve@mitre.org | https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=&t=1 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://arxiv.org/abs/2308.09019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://arxiv.org/pdf/2308.09019.pdf | Exploit, Technical Description, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/ | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://www.scitepress.org/Papers/2023/120929/120929.pdf | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=&t=1 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | tapo | 2.8.14 | |
| tp-link | tapo_l530e_firmware | 1.0.0 | |
| tp-link | tapo_l530e | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:tapo:2.8.14:*:*:*:*:*:*:*",
"matchCriteriaId": "D392C8A7-8A3F-490A-90B5-F7D7BFDC7F72",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:tapo_l530e_firmware:1.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "0427C4E5-322A-40F0-AA88-2FF57A32885F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:tapo_l530e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49091A2E-84FF-4A44-87EE-2BA8C366BE51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
},
{
"lang": "es",
"value": "un problema en TPLink Smart bulb Tapo series L530 v.1.0.0 y Tapo Application v.2.8.14 permite a un atacante remoto obtener informaci\u00f3n sensible a trav\u00e9s del componente IV en la funci\u00f3n AES128-CBC."
}
],
"id": "CVE-2023-38909",
"lastModified": "2024-11-21T08:14:25.580",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-22T01:15:08.537",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Technical Description",
"Third Party Advisory"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"source": "cve@mitre.org",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "cve@mitre.org",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Technical Description",
"Third Party Advisory"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-38908
Vulnerability from fkie_nvd - Published: 2023-08-22 01:15 - Updated: 2024-11-21 08:14
Severity ?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | tapo | 2.8.14 | |
| tp-link | tapo_l530e_firmware | 1.0.0 | |
| tp-link | tapo_l530e | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:tapo:2.8.14:*:*:*:*:*:*:*",
"matchCriteriaId": "D392C8A7-8A3F-490A-90B5-F7D7BFDC7F72",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:tapo_l530e_firmware:1.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "0427C4E5-322A-40F0-AA88-2FF57A32885F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:tapo_l530e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49091A2E-84FF-4A44-87EE-2BA8C366BE51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
},
{
"lang": "es",
"value": "Un problema en TPLink Smart bulb Tapo series L530 v.1.0.0 y la aplicaci\u00f3n Tapo v.2.8.14 permite a un atacante remoto obtener informaci\u00f3n confidencial a trav\u00e9s de la funci\u00f3n de autenticaci\u00f3n TSKEP."
}
],
"id": "CVE-2023-38908",
"lastModified": "2024-11-21T08:14:25.427",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-22T01:15:08.153",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "cve@mitre.org",
"tags": [
"Technical Description",
"Third Party Advisory"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"source": "cve@mitre.org",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "cve@mitre.org",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description",
"Third Party Advisory"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-38906
Vulnerability from fkie_nvd - Published: 2023-08-22 00:15 - Updated: 2024-11-21 08:14
Severity ?
Summary
An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | tapo | 2.8.14 | |
| tp-link | tapo_l530e_firmware | 1.0.0 | |
| tp-link | tapo_l530e | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:tapo:2.8.14:*:*:*:*:*:*:*",
"matchCriteriaId": "D392C8A7-8A3F-490A-90B5-F7D7BFDC7F72",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:tapo_l530e_firmware:1.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "0427C4E5-322A-40F0-AA88-2FF57A32885F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:tapo_l530e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49091A2E-84FF-4A44-87EE-2BA8C366BE51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
},
{
"lang": "es",
"value": "Un problema en la bombilla inteligente TP Link Tapo serie L530 v.1.0.0 y la aplicaci\u00f3n Tapo v.2.8.14 permite a un atacante remoto obtener informaci\u00f3n confidencial a trav\u00e9s del c\u00f3digo de autenticaci\u00f3n para el mensaje UDP."
}
],
"id": "CVE-2023-38906",
"lastModified": "2024-11-21T08:14:25.103",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-22T00:15:07.920",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "cve@mitre.org",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "cve@mitre.org",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-27098 (GCVE-0-2023-27098)
Vulnerability from cvelistv5 – Published: 2024-01-09 00:00 – Updated: 2025-06-18 16:57
VLAI?
Summary
TP-Link Tapo APK up to v2.12.703 uses hardcoded credentials for access to the login panel.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:01:32.348Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "http://tp-link.com"
},
{
"tags": [
"x_transferred"
],
"url": "http://tp-lin.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tp-link.com/support/contact-technical-support/#LiveChat-Support"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/c0d3x27/CVEs/tree/main/CVE-2023-27098"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-27098",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-09T16:12:46.723468Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-18T16:57:42.565Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TP-Link Tapo APK up to v2.12.703 uses hardcoded credentials for access to the login panel."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T01:10:11.743Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "http://tp-link.com"
},
{
"url": "http://tp-lin.com"
},
{
"url": "https://www.tp-link.com/support/contact-technical-support/#LiveChat-Support"
},
{
"url": "https://github.com/c0d3x27/CVEs/tree/main/CVE-2023-27098"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-27098",
"datePublished": "2024-01-09T00:00:00.000Z",
"dateReserved": "2023-02-27T00:00:00.000Z",
"dateUpdated": "2025-06-18T16:57:42.565Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34829 (GCVE-0-2023-34829)
Vulnerability from cvelistv5 – Published: 2023-12-28 00:00 – Updated: 2025-04-17 20:32
VLAI?
Summary
Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext.
Severity ?
6.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:17:04.158Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/SecureScripts/TP-Link_Tapo_Hack"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34829",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-02T19:10:45.480016Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-17T20:32:57.968Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-28T02:50:46.930Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/SecureScripts/TP-Link_Tapo_Hack"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34829",
"datePublished": "2023-12-28T00:00:00.000Z",
"dateReserved": "2023-06-07T00:00:00.000Z",
"dateUpdated": "2025-04-17T20:32:57.968Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38907 (GCVE-0-2023-38907)
Vulnerability from cvelistv5 – Published: 2023-09-25 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.232Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:31:52.486653",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38907",
"datePublished": "2023-09-25T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.232Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38908 (GCVE-0-2023-38908)
Vulnerability from cvelistv5 – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.219Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:18:59.022586",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38908",
"datePublished": "2023-08-22T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38909 (GCVE-0-2023-38909)
Vulnerability from cvelistv5 – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.599Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:26:21.306503",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38909",
"datePublished": "2023-08-22T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.599Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38906 (GCVE-0-2023-38906)
Vulnerability from cvelistv5 – Published: 2023-08-21 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:37:00.745727",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38906",
"datePublished": "2023-08-21T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.265Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27098 (GCVE-0-2023-27098)
Vulnerability from nvd – Published: 2024-01-09 00:00 – Updated: 2025-06-18 16:57
VLAI?
Summary
TP-Link Tapo APK up to v2.12.703 uses hardcoded credentials for access to the login panel.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:01:32.348Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "http://tp-link.com"
},
{
"tags": [
"x_transferred"
],
"url": "http://tp-lin.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tp-link.com/support/contact-technical-support/#LiveChat-Support"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/c0d3x27/CVEs/tree/main/CVE-2023-27098"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-27098",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-09T16:12:46.723468Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-18T16:57:42.565Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TP-Link Tapo APK up to v2.12.703 uses hardcoded credentials for access to the login panel."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T01:10:11.743Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "http://tp-link.com"
},
{
"url": "http://tp-lin.com"
},
{
"url": "https://www.tp-link.com/support/contact-technical-support/#LiveChat-Support"
},
{
"url": "https://github.com/c0d3x27/CVEs/tree/main/CVE-2023-27098"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-27098",
"datePublished": "2024-01-09T00:00:00.000Z",
"dateReserved": "2023-02-27T00:00:00.000Z",
"dateUpdated": "2025-06-18T16:57:42.565Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34829 (GCVE-0-2023-34829)
Vulnerability from nvd – Published: 2023-12-28 00:00 – Updated: 2025-04-17 20:32
VLAI?
Summary
Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext.
Severity ?
6.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:17:04.158Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/SecureScripts/TP-Link_Tapo_Hack"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34829",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-02T19:10:45.480016Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-17T20:32:57.968Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-28T02:50:46.930Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/SecureScripts/TP-Link_Tapo_Hack"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34829",
"datePublished": "2023-12-28T00:00:00.000Z",
"dateReserved": "2023-06-07T00:00:00.000Z",
"dateUpdated": "2025-04-17T20:32:57.968Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38907 (GCVE-0-2023-38907)
Vulnerability from nvd – Published: 2023-09-25 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.232Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:31:52.486653",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38907",
"datePublished": "2023-09-25T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.232Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38908 (GCVE-0-2023-38908)
Vulnerability from nvd – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.219Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:18:59.022586",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38908",
"datePublished": "2023-08-22T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38909 (GCVE-0-2023-38909)
Vulnerability from nvd – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.599Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:26:21.306503",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://arxiv.org/pdf/2308.09019.pdf"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38909",
"datePublished": "2023-08-22T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.599Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38906 (GCVE-0-2023-38906)
Vulnerability from nvd – Published: 2023-08-21 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:54:39.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"tags": [
"x_transferred"
],
"url": "https://arxiv.org/abs/2308.09019"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T14:37:00.745727",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
},
{
"url": "https://arxiv.org/abs/2308.09019"
},
{
"url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
},
{
"url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38906",
"datePublished": "2023-08-21T00:00:00",
"dateReserved": "2023-07-25T00:00:00",
"dateUpdated": "2024-08-02T17:54:39.265Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}