Search criteria
12 vulnerabilities found for vigorap_910c_firmware by draytek
FKIE_CVE-2020-28968
Vulnerability from fkie_nvd - Published: 2021-10-22 20:15 - Updated: 2024-11-21 05:23
Severity ?
Summary
Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://www.vulnerability-lab.com/get_content.php?id=2244 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.vulnerability-lab.com/get_content.php?id=2244 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorap_1000c_firmware | 1.3.2 | |
| draytek | vigorap_1000c | - | |
| draytek | vigorap_700_firmware | 1.11 | |
| draytek | vigorap_700 | - | |
| draytek | vigorap_710_firmware | 1.2.5 | |
| draytek | vigorap_710 | - | |
| draytek | vigorap_800_firmware | 1.1.4 | |
| draytek | vigorap_800 | - | |
| draytek | vigorap_802_firmware | 1.3.2 | |
| draytek | vigorap_802 | - | |
| draytek | vigorap_810_firmware | 1.2.5 | |
| draytek | vigorap_810 | - | |
| draytek | vigorap_900_firmware | 1.2.0 | |
| draytek | vigorap_900 | - | |
| draytek | vigorap_902_firmware | 1.2.5 | |
| draytek | vigorap_902 | - | |
| draytek | vigorap_903_firmware | 1.3.1 | |
| draytek | vigorap_903 | - | |
| draytek | vigorap_910c_firmware | 1.2.5 | |
| draytek | vigorap_910c | - | |
| draytek | vigorap_912c_firmware | 1.3.2 | |
| draytek | vigorap_912c | - | |
| draytek | vigorap_918r_firmware | 1.3.2 | |
| draytek | vigorap_918r | - | |
| draytek | vigorap_920r_firmware | 1.3.0 | |
| draytek | vigorap_920r | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_1000c_firmware:1.3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "742C6089-9E2E-4ECB-AF7E-5D9B894F9AED",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_1000c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E93E754E-F8F5-4E77-8ED1-BFA34C26C2F1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_700_firmware:1.11:*:*:*:*:*:*:*",
"matchCriteriaId": "159E7D7F-6753-4B9D-B68C-EBC8B103523C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "83567C7C-880E-4275-9146-A309C12272FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_710_firmware:1.2.5:*:*:*:*:*:*:*",
"matchCriteriaId": "57291C9F-03E6-471E-90AD-9EA3410386CA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_710:-:*:*:*:*:*:*:*",
"matchCriteriaId": "88458732-9951-41A4-8FF5-638E1C2849FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_800_firmware:1.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "89196326-E450-49BD-B6A0-A4CD83F16051",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "83AA8C11-D451-4545-8B83-80CB2B20EBB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_802_firmware:1.3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "BE6F104E-1406-4167-A0C7-00CBF0E1DC9B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DAE5715D-BA12-43D8-913F-3F067DBAE9BF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_810_firmware:1.2.5:*:*:*:*:*:*:*",
"matchCriteriaId": "3011DC89-E9B5-4359-8715-C9EAE5F5A63A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_810:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4093BE65-79DE-4920-AD37-B0A19E101993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_900_firmware:1.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DF25D657-6E0A-48FC-9218-ACF6BE1ABC6C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E891B2CB-6EB5-447B-A588-2CB1A99BF407",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_902_firmware:1.2.5:*:*:*:*:*:*:*",
"matchCriteriaId": "1023654B-CDFD-485A-92B5-37BD9AAE023E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_902:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E8BCD733-094A-42DC-BFFC-C0D77EF5B91F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_903_firmware:1.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "AB11C0E7-D52A-4ED2-8F0F-C5D418BE5046",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_903:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D793F78F-1A6C-47AC-9F17-877DA0C6DD7D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_910c_firmware:1.2.5:*:*:*:*:*:*:*",
"matchCriteriaId": "D6701321-8DF1-4BCF-8BF8-BBFE78720D13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_910c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2DE2DE3-EB97-45F2-87EF-B7F2B72F036B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_912c_firmware:1.3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "1B4544C4-4C80-4227-ADFC-24638764CAE6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_912c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F2052075-C2C4-4462-96B7-E3C448B81AD7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_918r_firmware:1.3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "9362C3C6-94A7-49EC-AA3F-CDA1F319366F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_918r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "257B6270-8551-4E08-8A04-E8D575407EE0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_920r_firmware:1.3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "7A824F6F-744D-4E6A-8319-5615827478DF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_920r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B9CAC188-1AA6-4158-89FE-42D4680F7A02",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field."
},
{
"lang": "es",
"value": "Draytek VigorAP 1000C contiene una vulnerabilidad de tipo cross-site scripting (XSS) almacenada en el m\u00f3dulo RADIUS Setting - RADIUS Server Configuration. Esta vulnerabilidad permite a atacantes ejecutar scripts web o HTML arbitrarios por medio de una carga \u00fatil dise\u00f1ada en el campo de entrada username"
}
],
"id": "CVE-2020-28968",
"lastModified": "2024-11-21T05:23:23.830",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-22T20:15:11.020",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-3932
Vulnerability from fkie_nvd - Published: 2020-04-15 07:15 - Updated: 2024-11-21 05:31
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage.
References
| URL | Tags | ||
|---|---|---|---|
| twcert@cert.org.tw | https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorap_910c_firmware | 1.3.1 | |
| draytek | vigorap_910c | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_910c_firmware:1.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "24AA83B5-0E47-4EE3-979E-71961BBF7710",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_910c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2DE2DE3-EB97-45F2-87EF-B7F2B72F036B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage."
},
{
"lang": "es",
"value": "Un SNMP vulnerable en Draytek VigorAP910C no puede ser deshabilitado lo que puede causar filtrado de informaci\u00f3n."
}
],
"id": "CVE-2020-3932",
"lastModified": "2024-11-21T05:31:59.197",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "twcert@cert.org.tw",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-15T07:15:13.067",
"references": [
{
"source": "twcert@cert.org.tw",
"tags": [
"Third Party Advisory"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
],
"sourceIdentifier": "twcert@cert.org.tw",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-11649
Vulnerability from fkie_nvd - Published: 2018-03-07 02:29 - Updated: 2024-11-21 03:08
Severity ?
Summary
Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorap_910c_firmware | 1.2.0 | |
| draytek | vigorap_910c | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_910c_firmware:1.2.0:rc3:*:*:*:*:*:*",
"matchCriteriaId": "A47E218D-D40D-4F24-B158-1DF0F011D8A7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_910c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2DE2DE3-EB97-45F2-87EF-B7F2B72F036B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp."
},
{
"lang": "es",
"value": "Vulnerabilidad de Cross-Site Request Forgery (CSRF) en dispositivos DrayTek Vigor AP910C con firmware 1.2.0_RC3 build r6594 permite que atacantes remotos secuestren la autenticaci\u00f3n de usuarios sin especificar para peticiones que habilitan SNMP en el dispositivo remoto mediante vectores relacionados con goform/setSnmp."
}
],
"id": "CVE-2017-11649",
"lastModified": "2024-11-21T03:08:13.573",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-07T02:29:00.517",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-11650
Vulnerability from fkie_nvd - Published: 2018-03-07 02:29 - Updated: 2024-11-21 03:08
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigorap_910c_firmware | 1.2.0 | |
| draytek | vigorap_910c | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorap_910c_firmware:1.2.0:rc3:*:*:*:*:*:*",
"matchCriteriaId": "A47E218D-D40D-4F24-B158-1DF0F011D8A7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigorap_910c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2DE2DE3-EB97-45F2-87EF-B7F2B72F036B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp."
},
{
"lang": "es",
"value": "Vulnerabilidad de Cross-Site Scripting (XSS) en dispositivos DrayTek Vigor AP910C con firmware 1.2.0_RC3 build r6594 permite que atacantes remotos inyecten scripts web o HTML arbitrarios mediante vectores relacionados con home.asp."
}
],
"id": "CVE-2017-11650",
"lastModified": "2024-11-21T03:08:13.727",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-07T02:29:00.563",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-28968 (GCVE-0-2020-28968)
Vulnerability from cvelistv5 – Published: 2021-10-22 19:20 – Updated: 2024-08-04 16:48
VLAI?
Summary
Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:00.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-22T19:20:05",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-28968",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.vulnerability-lab.com/get_content.php?id=2244",
"refsource": "MISC",
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-28968",
"datePublished": "2021-10-22T19:20:05",
"dateReserved": "2020-11-19T00:00:00",
"dateUpdated": "2024-08-04T16:48:00.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-3932 (GCVE-0-2020-3932)
Vulnerability from cvelistv5 – Published: 2020-04-15 06:20 – Updated: 2024-09-16 22:51
VLAI?
Title
Draytek VigorAP910C - Information Leakage
Summary
A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage.
Severity ?
7.5 (High)
CWE
- Information Leakage
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| DRAYTEK CORP. | VigorAP910C |
Affected:
unspecified , < 1.3.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:52:19.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "VigorAP910C",
"vendor": "DRAYTEK CORP.",
"versions": [
{
"lessThan": "1.3.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-04-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information Leakage",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-15T06:20:24",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Draytek VigorAP910C to version 1.3.2"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Draytek VigorAP910C - Information Leakage",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2020-04-15T05:30:00.000Z",
"ID": "CVE-2020-3932",
"STATE": "PUBLIC",
"TITLE": "Draytek VigorAP910C - Information Leakage"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "VigorAP910C",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.3.1"
}
]
}
}
]
},
"vendor_name": "DRAYTEK CORP."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Leakage"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Draytek VigorAP910C to version 1.3.2"
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2020-3932",
"datePublished": "2020-04-15T06:20:24.488515Z",
"dateReserved": "2019-12-20T00:00:00",
"dateUpdated": "2024-09-16T22:51:54.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-11649 (GCVE-0-2017-11649)
Vulnerability from cvelistv5 – Published: 2018-03-06 22:00 – Updated: 2024-08-05 18:12
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:12:40.570Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-03-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-06T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11649",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html",
"refsource": "MISC",
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-11649",
"datePublished": "2018-03-06T22:00:00",
"dateReserved": "2017-07-25T00:00:00",
"dateUpdated": "2024-08-05T18:12:40.570Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-11650 (GCVE-0-2017-11650)
Vulnerability from cvelistv5 – Published: 2018-03-06 22:00 – Updated: 2024-08-05 18:12
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:12:40.918Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-03-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-06T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11650",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html",
"refsource": "MISC",
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-11650",
"datePublished": "2018-03-06T22:00:00",
"dateReserved": "2017-07-25T00:00:00",
"dateUpdated": "2024-08-05T18:12:40.918Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-28968 (GCVE-0-2020-28968)
Vulnerability from nvd – Published: 2021-10-22 19:20 – Updated: 2024-08-04 16:48
VLAI?
Summary
Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:00.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-22T19:20:05",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-28968",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.vulnerability-lab.com/get_content.php?id=2244",
"refsource": "MISC",
"url": "https://www.vulnerability-lab.com/get_content.php?id=2244"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-28968",
"datePublished": "2021-10-22T19:20:05",
"dateReserved": "2020-11-19T00:00:00",
"dateUpdated": "2024-08-04T16:48:00.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-3932 (GCVE-0-2020-3932)
Vulnerability from nvd – Published: 2020-04-15 06:20 – Updated: 2024-09-16 22:51
VLAI?
Title
Draytek VigorAP910C - Information Leakage
Summary
A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage.
Severity ?
7.5 (High)
CWE
- Information Leakage
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| DRAYTEK CORP. | VigorAP910C |
Affected:
unspecified , < 1.3.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:52:19.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "VigorAP910C",
"vendor": "DRAYTEK CORP.",
"versions": [
{
"lessThan": "1.3.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-04-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information Leakage",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-15T06:20:24",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update Draytek VigorAP910C to version 1.3.2"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Draytek VigorAP910C - Information Leakage",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2020-04-15T05:30:00.000Z",
"ID": "CVE-2020-3932",
"STATE": "PUBLIC",
"TITLE": "Draytek VigorAP910C - Information Leakage"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "VigorAP910C",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.3.1"
}
]
}
}
]
},
"vendor_name": "DRAYTEK CORP."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerable SNMP in Draytek VigorAP910C cannot be disabled, which may cause information leakage."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Leakage"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-3537-1e215-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update Draytek VigorAP910C to version 1.3.2"
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2020-3932",
"datePublished": "2020-04-15T06:20:24.488515Z",
"dateReserved": "2019-12-20T00:00:00",
"dateUpdated": "2024-09-16T22:51:54.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-11649 (GCVE-0-2017-11649)
Vulnerability from nvd – Published: 2018-03-06 22:00 – Updated: 2024-08-05 18:12
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:12:40.570Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-03-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-06T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11649",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to hijack the authentication of unspecified users for requests that enable SNMP on the remote device via vectors involving goform/setSnmp."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html",
"refsource": "MISC",
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-11649",
"datePublished": "2018-03-06T22:00:00",
"dateReserved": "2017-07-25T00:00:00",
"dateUpdated": "2024-08-05T18:12:40.570Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-11650 (GCVE-0-2017-11650)
Vulnerability from nvd – Published: 2018-03-06 22:00 – Updated: 2024-08-05 18:12
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:12:40.918Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-03-03T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-06T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11650",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in DrayTek Vigor AP910C devices with firmware 1.2.0_RC3 build r6594 allows remote attackers to inject arbitrary web script or HTML via vectors involving home.asp."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html",
"refsource": "MISC",
"url": "https://iscouncil.blogspot.in/2018/03/dray-tek-vigor-ap910c-multiple.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-11650",
"datePublished": "2018-03-06T22:00:00",
"dateReserved": "2017-07-25T00:00:00",
"dateUpdated": "2024-08-05T18:12:40.918Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}