All the vulnerabilites related to cisco - vpn_3060_concentrator
cve-2005-0943
Vulnerability from cvelistv5
Published
2005-04-03 05:00
Modified
2024-08-07 21:28
Severity ?
Summary
Cisco VPN 3000 series Concentrator running firmware 4.1.7.A and earlier allows remote attackers to cause a denial of service (device reload or drop user connection) via a crafted HTTPS packet.
References
http://www.cisco.com/warp/public/707/cisco-sa-20050330-vpn3k.shtmlvendor-advisory, x_refsource_CISCO
http://www.securityfocus.com/bid/12948vdb-entry, x_refsource_BID
http://secunia.com/advisories/14784third-party-advisory, x_refsource_SECUNIA
https://exchange.xforce.ibmcloud.com/vulnerabilities/19903vdb-entry, x_refsource_XF
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T21:28:29.161Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20050330 Cisco VPN 3000 Concentrator Vulnerable to Crafted SSL Attack",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/warp/public/707/cisco-sa-20050330-vpn3k.shtml"
          },
          {
            "name": "12948",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/12948"
          },
          {
            "name": "14784",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/14784"
          },
          {
            "name": "cisco-vpn-3000-dos(19903)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/19903"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2005-03-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco VPN 3000 series Concentrator running firmware 4.1.7.A and earlier allows remote attackers to cause a denial of service (device reload or drop user connection) via a crafted HTTPS packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-10T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20050330 Cisco VPN 3000 Concentrator Vulnerable to Crafted SSL Attack",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/warp/public/707/cisco-sa-20050330-vpn3k.shtml"
        },
        {
          "name": "12948",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/12948"
        },
        {
          "name": "14784",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/14784"
        },
        {
          "name": "cisco-vpn-3000-dos(19903)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/19903"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2005-0943",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco VPN 3000 series Concentrator running firmware 4.1.7.A and earlier allows remote attackers to cause a denial of service (device reload or drop user connection) via a crafted HTTPS packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20050330 Cisco VPN 3000 Concentrator Vulnerable to Crafted SSL Attack",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/warp/public/707/cisco-sa-20050330-vpn3k.shtml"
            },
            {
              "name": "12948",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/12948"
            },
            {
              "name": "14784",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/14784"
            },
            {
              "name": "cisco-vpn-3000-dos(19903)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/19903"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2005-0943",
    "datePublished": "2005-04-03T05:00:00",
    "dateReserved": "2005-04-03T00:00:00",
    "dateUpdated": "2024-08-07T21:28:29.161Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2010-4354
Vulnerability from cvelistv5
Published
2010-11-30 22:00
Modified
2024-09-16 18:18
Severity ?
Summary
The remote-access IPSec VPN implementation on Cisco Adaptive Security Appliances (ASA) 5500 series devices, PIX Security Appliances 500 series devices, and VPN Concentrators 3000 series devices responds to an Aggressive Mode IKE Phase I message only when the group name is configured on the device, which allows remote attackers to enumerate valid group names via a series of IKE negotiation attempts, aka Bug ID CSCtj96108, a different vulnerability than CVE-2005-2025.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T03:43:14.665Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20101129 Cisco IPSec VPN Implementation Group Name Enumeration Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/en/US/products/products_security_response09186a0080b5992c.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The remote-access IPSec VPN implementation on Cisco Adaptive Security Appliances (ASA) 5500 series devices, PIX Security Appliances 500 series devices, and VPN Concentrators 3000 series devices responds to an Aggressive Mode IKE Phase I message only when the group name is configured on the device, which allows remote attackers to enumerate valid group names via a series of IKE negotiation attempts, aka Bug ID CSCtj96108, a different vulnerability than CVE-2005-2025."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2010-11-30T22:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20101129 Cisco IPSec VPN Implementation Group Name Enumeration Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/en/US/products/products_security_response09186a0080b5992c.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2010-4354",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The remote-access IPSec VPN implementation on Cisco Adaptive Security Appliances (ASA) 5500 series devices, PIX Security Appliances 500 series devices, and VPN Concentrators 3000 series devices responds to an Aggressive Mode IKE Phase I message only when the group name is configured on the device, which allows remote attackers to enumerate valid group names via a series of IKE negotiation attempts, aka Bug ID CSCtj96108, a different vulnerability than CVE-2005-2025."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20101129 Cisco IPSec VPN Implementation Group Name Enumeration Vulnerability",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/en/US/products/products_security_response09186a0080b5992c.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2010-4354",
    "datePublished": "2010-11-30T22:00:00Z",
    "dateReserved": "2010-11-30T00:00:00Z",
    "dateUpdated": "2024-09-16T18:18:43.875Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2001-0427
Vulnerability from cvelistv5
Published
2001-09-18 04:00
Modified
2024-08-08 04:21
Severity ?
Summary
Cisco VPN 3000 series concentrators before 2.5.2(F) allow remote attackers to cause a denial of service via a flood of invalid login requests to (1) the SSL service, or (2) the telnet service, which do not properly disconnect the user after several failed login attempts.
References
http://www.cisco.com/warp/public/707/vpn3k-telnet-vuln-pub.shtmlvendor-advisory, x_refsource_CISCO
http://www.osvdb.org/5643vdb-entry, x_refsource_OSVDB
https://exchange.xforce.ibmcloud.com/vulnerabilities/6298vdb-entry, x_refsource_XF
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-08T04:21:38.518Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20010328 VPN3000 Concentrator TELNET Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/warp/public/707/vpn3k-telnet-vuln-pub.shtml"
          },
          {
            "name": "5643",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/5643"
          },
          {
            "name": "cisco-vpn-telnet-dos(6298)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/6298"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2001-03-28T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco VPN 3000 series concentrators before 2.5.2(F) allow remote attackers to cause a denial of service via a flood of invalid login requests to (1) the SSL service, or (2) the telnet service, which do not properly disconnect the user after several failed login attempts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2004-09-02T09:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20010328 VPN3000 Concentrator TELNET Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/warp/public/707/vpn3k-telnet-vuln-pub.shtml"
        },
        {
          "name": "5643",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/5643"
        },
        {
          "name": "cisco-vpn-telnet-dos(6298)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/6298"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2001-0427",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco VPN 3000 series concentrators before 2.5.2(F) allow remote attackers to cause a denial of service via a flood of invalid login requests to (1) the SSL service, or (2) the telnet service, which do not properly disconnect the user after several failed login attempts."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20010328 VPN3000 Concentrator TELNET Vulnerability",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/warp/public/707/vpn3k-telnet-vuln-pub.shtml"
            },
            {
              "name": "5643",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/5643"
            },
            {
              "name": "cisco-vpn-telnet-dos(6298)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/6298"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2001-0427",
    "datePublished": "2001-09-18T04:00:00",
    "dateReserved": "2001-05-24T00:00:00",
    "dateUpdated": "2024-08-08T04:21:38.518Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2003-0260
Vulnerability from cvelistv5
Published
2003-05-08 04:00
Modified
2024-08-08 01:50
Severity ?
Summary
Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7A allow remote attackers to cause a denial of service (slowdown and possibly reload) via a flood of malformed ICMP packets.
References
https://exchange.xforce.ibmcloud.com/vulnerabilities/11956vdb-entry, x_refsource_XF
http://www.kb.cert.org/vuls/id/221164third-party-advisory, x_refsource_CERT-VN
http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtmlvendor-advisory, x_refsource_CISCO
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-08T01:50:46.871Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "cisco-vpn-icmp-dos(11956)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11956"
          },
          {
            "name": "VU#221164",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/221164"
          },
          {
            "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2003-05-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7A allow remote attackers to cause a denial of service (slowdown and possibly reload) via a flood of malformed ICMP packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-10T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "cisco-vpn-icmp-dos(11956)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11956"
        },
        {
          "name": "VU#221164",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/221164"
        },
        {
          "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2003-0260",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7A allow remote attackers to cause a denial of service (slowdown and possibly reload) via a flood of malformed ICMP packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "cisco-vpn-icmp-dos(11956)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11956"
            },
            {
              "name": "VU#221164",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/221164"
            },
            {
              "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2003-0260",
    "datePublished": "2003-05-08T04:00:00",
    "dateReserved": "2003-05-07T00:00:00",
    "dateUpdated": "2024-08-08T01:50:46.871Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2003-0258
Vulnerability from cvelistv5
Published
2003-05-08 04:00
Modified
2024-08-08 01:50
Severity ?
Summary
Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 3.5.x through 4.0.REL, when enabling IPSec over TCP for a port on the concentrator, allow remote attackers to reach the private network without authentication.
References
http://www.kb.cert.org/vuls/id/727780third-party-advisory, x_refsource_CERT-VN
http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtmlvendor-advisory, x_refsource_CISCO
https://exchange.xforce.ibmcloud.com/vulnerabilities/11954vdb-entry, x_refsource_XF
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-08T01:50:46.866Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#727780",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/727780"
          },
          {
            "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
          },
          {
            "name": "cisco-vpn-unauth-access(11954)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11954"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2003-05-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 3.5.x through 4.0.REL, when enabling IPSec over TCP for a port on the concentrator, allow remote attackers to reach the private network without authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-10T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "VU#727780",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/727780"
        },
        {
          "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
        },
        {
          "name": "cisco-vpn-unauth-access(11954)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11954"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2003-0258",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 3.5.x through 4.0.REL, when enabling IPSec over TCP for a port on the concentrator, allow remote attackers to reach the private network without authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#727780",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/727780"
            },
            {
              "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
            },
            {
              "name": "cisco-vpn-unauth-access(11954)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11954"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2003-0258",
    "datePublished": "2003-05-08T04:00:00",
    "dateReserved": "2003-05-07T00:00:00",
    "dateUpdated": "2024-08-08T01:50:46.866Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2003-0259
Vulnerability from cvelistv5
Published
2003-05-08 04:00
Modified
2024-08-08 01:50
Severity ?
Summary
Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7 allows remote attackers to cause a denial of service (reload) via a malformed SSH initialization packet.
References
https://exchange.xforce.ibmcloud.com/vulnerabilities/11955vdb-entry, x_refsource_XF
http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtmlvendor-advisory, x_refsource_CISCO
http://www.kb.cert.org/vuls/id/317348third-party-advisory, x_refsource_CERT-VN
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-08T01:50:47.052Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "cisco-vpn-ssh-dos(11955)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11955"
          },
          {
            "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
          },
          {
            "name": "VU#317348",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/317348"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2003-05-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7 allows remote attackers to cause a denial of service (reload) via a malformed SSH initialization packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-10T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "cisco-vpn-ssh-dos(11955)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11955"
        },
        {
          "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
        },
        {
          "name": "VU#317348",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/317348"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2003-0259",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7 allows remote attackers to cause a denial of service (reload) via a malformed SSH initialization packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "cisco-vpn-ssh-dos(11955)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11955"
            },
            {
              "name": "20030507 Cisco VPN 3000 Concentrator Vulnerabilities",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
            },
            {
              "name": "VU#317348",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/317348"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2003-0259",
    "datePublished": "2003-05-08T04:00:00",
    "dateReserved": "2003-05-07T00:00:00",
    "dateUpdated": "2024-08-08T01:50:47.052Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2006-3906
Vulnerability from cvelistv5
Published
2006-07-27 22:00
Modified
2024-08-07 18:48
Severity ?
Summary
Internet Key Exchange (IKE) version 1 protocol, as implemented on Cisco IOS, VPN 3000 Concentrators, and PIX firewalls, allows remote attackers to cause a denial of service (resource exhaustion) via a flood of IKE Phase-1 packets that exceed the session expiration rate. NOTE: it has been argued that this is due to a design weakness of the IKE version 1 protocol, in which case other vendors and implementations would also be affected.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T18:48:39.430Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html"
          },
          {
            "name": "19176",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/19176"
          },
          {
            "name": "20060726 Cisco VPN Concentrator IKE resource exhaustion DoS Advisory",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/441203/100/0/threaded"
          },
          {
            "name": "29068",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/29068"
          },
          {
            "name": "20060728 Re: Cisco VPN Concentrator IKE resource exhaustion DoS Advisory",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html"
          },
          {
            "name": "oval:org.mitre.oval:def:5299",
            "tags": [
              "vdb-entry",
              "signature",
              "x_refsource_OVAL",
              "x_transferred"
            ],
            "url": "https://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299"
          },
          {
            "name": "1016582",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://securitytracker.com/id?1016582"
          },
          {
            "name": "1293",
            "tags": [
              "third-party-advisory",
              "x_refsource_SREASON",
              "x_transferred"
            ],
            "url": "http://securityreason.com/securityalert/1293"
          },
          {
            "name": "20060726 Internet Key Exchange Resource Exhaustion Attack",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html"
          },
          {
            "name": "cisco-ike-resource-exhaustion-dos(27972)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/27972"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2006-07-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Internet Key Exchange (IKE) version 1 protocol, as implemented on Cisco IOS, VPN 3000 Concentrators, and PIX firewalls, allows remote attackers to cause a denial of service (resource exhaustion) via a flood of IKE Phase-1 packets that exceed the session expiration rate. NOTE: it has been argued that this is due to a design weakness of the IKE version 1 protocol, in which case other vendors and implementations would also be affected."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-17T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html"
        },
        {
          "name": "19176",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/19176"
        },
        {
          "name": "20060726 Cisco VPN Concentrator IKE resource exhaustion DoS Advisory",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/441203/100/0/threaded"
        },
        {
          "name": "29068",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/29068"
        },
        {
          "name": "20060728 Re: Cisco VPN Concentrator IKE resource exhaustion DoS Advisory",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html"
        },
        {
          "name": "oval:org.mitre.oval:def:5299",
          "tags": [
            "vdb-entry",
            "signature",
            "x_refsource_OVAL"
          ],
          "url": "https://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299"
        },
        {
          "name": "1016582",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://securitytracker.com/id?1016582"
        },
        {
          "name": "1293",
          "tags": [
            "third-party-advisory",
            "x_refsource_SREASON"
          ],
          "url": "http://securityreason.com/securityalert/1293"
        },
        {
          "name": "20060726 Internet Key Exchange Resource Exhaustion Attack",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "http://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html"
        },
        {
          "name": "cisco-ike-resource-exhaustion-dos(27972)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/27972"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2006-3906",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Internet Key Exchange (IKE) version 1 protocol, as implemented on Cisco IOS, VPN 3000 Concentrators, and PIX firewalls, allows remote attackers to cause a denial of service (resource exhaustion) via a flood of IKE Phase-1 packets that exceed the session expiration rate. NOTE: it has been argued that this is due to a design weakness of the IKE version 1 protocol, in which case other vendors and implementations would also be affected."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html",
              "refsource": "MISC",
              "url": "http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html"
            },
            {
              "name": "19176",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/19176"
            },
            {
              "name": "20060726 Cisco VPN Concentrator IKE resource exhaustion DoS Advisory",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/441203/100/0/threaded"
            },
            {
              "name": "29068",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/29068"
            },
            {
              "name": "20060728 Re: Cisco VPN Concentrator IKE resource exhaustion DoS Advisory",
              "refsource": "BUGTRAQ",
              "url": "http://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html"
            },
            {
              "name": "oval:org.mitre.oval:def:5299",
              "refsource": "OVAL",
              "url": "https://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299"
            },
            {
              "name": "1016582",
              "refsource": "SECTRACK",
              "url": "http://securitytracker.com/id?1016582"
            },
            {
              "name": "1293",
              "refsource": "SREASON",
              "url": "http://securityreason.com/securityalert/1293"
            },
            {
              "name": "20060726 Internet Key Exchange Resource Exhaustion Attack",
              "refsource": "CISCO",
              "url": "http://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html"
            },
            {
              "name": "cisco-ike-resource-exhaustion-dos(27972)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/27972"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2006-3906",
    "datePublished": "2006-07-27T22:00:00",
    "dateReserved": "2006-07-27T00:00:00",
    "dateUpdated": "2024-08-07T18:48:39.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2005-2025
Vulnerability from cvelistv5
Published
2005-06-21 04:00
Modified
2024-08-07 22:15
Severity ?
Summary
Cisco VPN 3000 Concentrator before 4.1.7.F allows remote attackers to determine valid groupnames by sending an IKE Aggressive Mode packet with the groupname in the ID field, which generates a response if the groupname is valid, but does not generate a response for an invalid groupname.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T22:15:36.602Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.nta-monitor.com/news/vpn-flaws/cisco/VPN-Concentrator/index.htm"
          },
          {
            "name": "13992",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/13992"
          },
          {
            "name": "ADV-2005-0822",
            "tags": [
              "vdb-entry",
              "x_refsource_VUPEN",
              "x_transferred"
            ],
            "url": "http://www.vupen.com/english/advisories/2005/0822"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2005-06-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cisco VPN 3000 Concentrator before 4.1.7.F allows remote attackers to determine valid groupnames by sending an IKE Aggressive Mode packet with the groupname in the ID field, which generates a response if the groupname is valid, but does not generate a response for an invalid groupname."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2009-02-26T10:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.nta-monitor.com/news/vpn-flaws/cisco/VPN-Concentrator/index.htm"
        },
        {
          "name": "13992",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/13992"
        },
        {
          "name": "ADV-2005-0822",
          "tags": [
            "vdb-entry",
            "x_refsource_VUPEN"
          ],
          "url": "http://www.vupen.com/english/advisories/2005/0822"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2005-2025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cisco VPN 3000 Concentrator before 4.1.7.F allows remote attackers to determine valid groupnames by sending an IKE Aggressive Mode packet with the groupname in the ID field, which generates a response if the groupname is valid, but does not generate a response for an invalid groupname."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.nta-monitor.com/news/vpn-flaws/cisco/VPN-Concentrator/index.htm",
              "refsource": "MISC",
              "url": "http://www.nta-monitor.com/news/vpn-flaws/cisco/VPN-Concentrator/index.htm"
            },
            {
              "name": "13992",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/13992"
            },
            {
              "name": "ADV-2005-0822",
              "refsource": "VUPEN",
              "url": "http://www.vupen.com/english/advisories/2005/0822"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2005-2025",
    "datePublished": "2005-06-21T04:00:00",
    "dateReserved": "2005-06-21T00:00:00",
    "dateUpdated": "2024-08-07T22:15:36.602Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2005-4499
Vulnerability from cvelistv5
Published
2005-12-22 11:00
Modified
2024-08-07 23:46
Severity ?
Summary
The Downloadable RADIUS ACLs feature in Cisco PIX and VPN 3000 concentrators, when creating an ACL on the Cisco Secure Access Control Server (CS ACS), generates a random internal name for an ACL that is also used as a hidden user name and password, which allows remote attackers to gain privileges by sniffing the username from the cleartext portion of a RADIUS session, then using the password to log in to another device that uses CS ACS.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T23:46:05.525Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20051221 Cisco PIX / CS ACS: Downloadable RADIUS ACLs vulnerability",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/420020/100/0/threaded"
          },
          {
            "name": "16025",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/16025"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_field_notice09186a00805bf1c4.shtml"
          },
          {
            "name": "22193",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/22193"
          },
          {
            "name": "20051222 Re: Cisco PIX / CS ACS: Downloadable RADIUS ACLs vulnerability",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/420103/100/0/threaded"
          },
          {
            "name": "18141",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/18141"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2005-12-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Downloadable RADIUS ACLs feature in Cisco PIX and VPN 3000 concentrators, when creating an ACL on the Cisco Secure Access Control Server (CS ACS), generates a random internal name for an ACL that is also used as a hidden user name and password, which allows remote attackers to gain privileges by sniffing the username from the cleartext portion of a RADIUS session, then using the password to log in to another device that uses CS ACS."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-19T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20051221 Cisco PIX / CS ACS: Downloadable RADIUS ACLs vulnerability",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/420020/100/0/threaded"
        },
        {
          "name": "16025",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/16025"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_field_notice09186a00805bf1c4.shtml"
        },
        {
          "name": "22193",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/22193"
        },
        {
          "name": "20051222 Re: Cisco PIX / CS ACS: Downloadable RADIUS ACLs vulnerability",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/420103/100/0/threaded"
        },
        {
          "name": "18141",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/18141"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2005-4499",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Downloadable RADIUS ACLs feature in Cisco PIX and VPN 3000 concentrators, when creating an ACL on the Cisco Secure Access Control Server (CS ACS), generates a random internal name for an ACL that is also used as a hidden user name and password, which allows remote attackers to gain privileges by sniffing the username from the cleartext portion of a RADIUS session, then using the password to log in to another device that uses CS ACS."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20051221 Cisco PIX / CS ACS: Downloadable RADIUS ACLs vulnerability",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/420020/100/0/threaded"
            },
            {
              "name": "16025",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/16025"
            },
            {
              "name": "http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_field_notice09186a00805bf1c4.shtml",
              "refsource": "MISC",
              "url": "http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_field_notice09186a00805bf1c4.shtml"
            },
            {
              "name": "22193",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/22193"
            },
            {
              "name": "20051222 Re: Cisco PIX / CS ACS: Downloadable RADIUS ACLs vulnerability",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/420103/100/0/threaded"
            },
            {
              "name": "18141",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/18141"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2005-4499",
    "datePublished": "2005-12-22T11:00:00",
    "dateReserved": "2005-12-22T00:00:00",
    "dateUpdated": "2024-08-07T23:46:05.525Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2005-03-30 05:00
Modified
2024-11-20 23:56
Severity ?
Summary
Cisco VPN 3000 series Concentrator running firmware 4.1.7.A and earlier allows remote attackers to cause a denial of service (device reload or drop user connection) via a crafted HTTPS packet.
Impacted products
Vendor Product Version
cisco vpn_3015_concentrator *
cisco vpn_3020_concentrator *
cisco vpn_3030_concentator *
cisco vpn_3060_concentrator *
cisco vpn_3080_concentrator *
cisco vpn_3000_concentrator_series_software 2.0
cisco vpn_3000_concentrator_series_software 2.5.2.a
cisco vpn_3000_concentrator_series_software 2.5.2.b
cisco vpn_3000_concentrator_series_software 2.5.2.c
cisco vpn_3000_concentrator_series_software 2.5.2.d
cisco vpn_3000_concentrator_series_software 2.5.2.f
cisco vpn_3000_concentrator_series_software 3.0
cisco vpn_3000_concentrator_series_software 3.0.3.a
cisco vpn_3000_concentrator_series_software 3.0.3.b
cisco vpn_3000_concentrator_series_software 3.0.4
cisco vpn_3000_concentrator_series_software 3.1
cisco vpn_3000_concentrator_series_software 3.1\(rel\)
cisco vpn_3000_concentrator_series_software 3.1.1
cisco vpn_3000_concentrator_series_software 3.1.2
cisco vpn_3000_concentrator_series_software 3.1.4
cisco vpn_3000_concentrator_series_software 3.5\(rel\)
cisco vpn_3000_concentrator_series_software 3.5.1
cisco vpn_3000_concentrator_series_software 3.5.2
cisco vpn_3000_concentrator_series_software 3.5.3
cisco vpn_3000_concentrator_series_software 3.5.4
cisco vpn_3000_concentrator_series_software 3.5.5
cisco vpn_3000_concentrator_series_software 3.6
cisco vpn_3000_concentrator_series_software 3.6.1
cisco vpn_3000_concentrator_series_software 3.6.3
cisco vpn_3000_concentrator_series_software 3.6.5
cisco vpn_3000_concentrator_series_software 3.6.7
cisco vpn_3000_concentrator_series_software 3.6.7.a
cisco vpn_3000_concentrator_series_software 3.6.7.b
cisco vpn_3000_concentrator_series_software 3.6.7.c
cisco vpn_3000_concentrator_series_software 3.6.7.d
cisco vpn_3000_concentrator_series_software 3.6.7.f
cisco vpn_3000_concentrator_series_software 3.6.7d
cisco vpn_3000_concentrator_series_software 4.0
cisco vpn_3000_concentrator_series_software 4.0.1
cisco vpn_3000_concentrator_series_software 4.0.5.b
cisco vpn_3000_concentrator_series_software 4.1
cisco vpn_3000_concentrator_series_software 4.1.5.b
cisco vpn_3000_concentrator_series_software 4.1.7.a
cisco vpn_3005_concentrator_software 4.0.1
cisco vpn_3002_hardware_client *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3020_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5D50FE2-A4E6-4EF4-A91C-88FB0AF6CCB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "923949D1-06EC-462F-A3BC-FCAB448042A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "901B1838-7169-41E5-80EF-29BB680BF937",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAEAA5F-0A98-48B7-8012-9B9909243135",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "11DA4B03-2D30-4514-9DF5-5F0DDD4B8DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB38834B-E4AB-43F4-888B-14B088C95594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "23F8059B-3968-4D63-B1B3-74E545C918D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "701CDA0D-F932-4251-B484-8F20F0AE9003",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "E674AA43-905E-40E0-A70F-77D05C62C18D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0D767F-7142-46D2-B3E4-7FE8E9E3285A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "057A6BA0-5F5E-4FC4-B2EC-A17968EAC2C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "645AB682-2965-4C8D-B323-AB510E424407",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "76F7F019-A0A4-49CD-BB28-24BF7725AC89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "175CD875-3402-4B06-A3FA-7DFFCBB44056",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF61B8A5-31E7-40F5-8B3D-CA90E50618AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C9017BB-5848-4361-ABB9-C69FB3AB90FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF5F3FA-5FA4-408E-BA62-3943C5DFD859",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2AFAF42-B894-4D62-A9CF-3349A43191AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE5BB7F-D8B4-441B-9F45-56F622EEAA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B87A7EC-DC23-4075-8C4A-2317FF34BDB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "98AC18E3-D12B-489D-9D95-6C9210235FB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9DB969E-8BE9-46E0-B8AA-5057E320F1ED",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7d:*:*:*:*:*:*:*",
              "matchCriteriaId": "36291ADE-3D5A-4E49-8BA7-B71CAAA226B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D953DA9F-B54E-4941-85BE-48933C98DB55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E298AD-26AC-4E1D-83D8-5C2016CC6559",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "B71DAF71-5763-44D8-AD1E-5ADE8BC15120",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B35B6FA9-E504-4CE3-B171-815291A812CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFA54782-93A8-47BE-863D-89CA3678BF6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "67F66A10-246D-447B-941F-F1175684F0D6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3005_concentrator_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "17196F00-9D7A-4AF6-AE1E-EA2E450A8ABD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:vpn_3002_hardware_client:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12ECF578-84BF-4F41-9462-C09FA517F2A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cisco VPN 3000 series Concentrator running firmware 4.1.7.A and earlier allows remote attackers to cause a denial of service (device reload or drop user connection) via a crafted HTTPS packet."
    }
  ],
  "id": "CVE-2005-0943",
  "lastModified": "2024-11-20T23:56:14.487",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2005-03-30T05:00:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/14784"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20050330-vpn3k.shtml"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.securityfocus.com/bid/12948"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/19903"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/14784"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20050330-vpn3k.shtml"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.securityfocus.com/bid/12948"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/19903"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2001-06-18 04:00
Modified
2024-11-20 23:35
Severity ?
Summary
Cisco VPN 3000 series concentrators before 2.5.2(F) allow remote attackers to cause a denial of service via a flood of invalid login requests to (1) the SSL service, or (2) the telnet service, which do not properly disconnect the user after several failed login attempts.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3000_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24BE2649-D823-486B-8F6C-4B8128EC2795",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3005_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E098419B-1B9E-4191-9C72-65CE43E38F3B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cisco VPN 3000 series concentrators before 2.5.2(F) allow remote attackers to cause a denial of service via a flood of invalid login requests to (1) the SSL service, or (2) the telnet service, which do not properly disconnect the user after several failed login attempts."
    }
  ],
  "id": "CVE-2001-0427",
  "lastModified": "2024-11-20T23:35:20.590",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2001-06-18T04:00:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/vpn3k-telnet-vuln-pub.shtml"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.osvdb.org/5643"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/6298"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/vpn3k-telnet-vuln-pub.shtml"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.osvdb.org/5643"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/6298"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2003-05-27 04:00
Modified
2024-11-20 23:44
Severity ?
Summary
Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 3.5.x through 4.0.REL, when enabling IPSec over TCP for a port on the concentrator, allow remote attackers to reach the private network without authentication.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF5F3FA-5FA4-408E-BA62-3943C5DFD859",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2AFAF42-B894-4D62-A9CF-3349A43191AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE5BB7F-D8B4-441B-9F45-56F622EEAA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B87A7EC-DC23-4075-8C4A-2317FF34BDB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "98AC18E3-D12B-489D-9D95-6C9210235FB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7d:*:*:*:*:*:*:*",
              "matchCriteriaId": "36291ADE-3D5A-4E49-8BA7-B71CAAA226B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D953DA9F-B54E-4941-85BE-48933C98DB55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3005_concentrator_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "17196F00-9D7A-4AF6-AE1E-EA2E450A8ABD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:vpn_3002_hardware_client:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12ECF578-84BF-4F41-9462-C09FA517F2A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 3.5.x through 4.0.REL, when enabling IPSec over TCP for a port on the concentrator, allow remote attackers to reach the private network without authentication."
    },
    {
      "lang": "es",
      "value": "Concentradores de Cisco de la serie VPN 3000 y Cisco VPN 3002 Hardware Client 2.x.x hasta 4.0.REL, cuando se configuran para permitir IPSec sobre TCP para un puerto del concentrador, permiten que atacantes remotos alcancen la red privada sin autentificaci\u00f3n."
    }
  ],
  "id": "CVE-2003-0258",
  "lastModified": "2024-11-20T23:44:19.913",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": true,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2003-05-27T04:00:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/727780"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11954"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/727780"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11954"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2003-05-27 04:00
Modified
2024-11-20 23:44
Severity ?
Summary
Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7A allow remote attackers to cause a denial of service (slowdown and possibly reload) via a flood of malformed ICMP packets.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "923949D1-06EC-462F-A3BC-FCAB448042A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "901B1838-7169-41E5-80EF-29BB680BF937",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAEAA5F-0A98-48B7-8012-9B9909243135",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "11DA4B03-2D30-4514-9DF5-5F0DDD4B8DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB38834B-E4AB-43F4-888B-14B088C95594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "23F8059B-3968-4D63-B1B3-74E545C918D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "701CDA0D-F932-4251-B484-8F20F0AE9003",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "E674AA43-905E-40E0-A70F-77D05C62C18D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0D767F-7142-46D2-B3E4-7FE8E9E3285A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "057A6BA0-5F5E-4FC4-B2EC-A17968EAC2C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "645AB682-2965-4C8D-B323-AB510E424407",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "76F7F019-A0A4-49CD-BB28-24BF7725AC89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "175CD875-3402-4B06-A3FA-7DFFCBB44056",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF61B8A5-31E7-40F5-8B3D-CA90E50618AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C9017BB-5848-4361-ABB9-C69FB3AB90FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF5F3FA-5FA4-408E-BA62-3943C5DFD859",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:vpn_3002_hardware_client:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12ECF578-84BF-4F41-9462-C09FA517F2A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7A allow remote attackers to cause a denial of service (slowdown and possibly reload) via a flood of malformed ICMP packets."
    },
    {
      "lang": "es",
      "value": "Concentradores de Cisco de la serie VPN 3000 y Cisco VPN 3002 Hardware Client 2.x.x hasta 3.6.7A  permiten que atacantes remotos causen una denegaci\u00f3n de servicio (ralentizaci\u00f3n y posiblemente recarga) mediante una inundaci\u00f3n con paquetes ICMP mal constru\u00eddos."
    }
  ],
  "id": "CVE-2003-0260",
  "lastModified": "2024-11-20T23:44:20.210",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2003-05-27T04:00:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/221164"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11956"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/221164"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11956"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2006-07-27 22:04
Modified
2024-11-21 00:14
Severity ?
Summary
Internet Key Exchange (IKE) version 1 protocol, as implemented on Cisco IOS, VPN 3000 Concentrators, and PIX firewalls, allows remote attackers to cause a denial of service (resource exhaustion) via a flood of IKE Phase-1 packets that exceed the session expiration rate. NOTE: it has been argued that this is due to a design weakness of the IKE version 1 protocol, in which case other vendors and implementations would also be affected.
References
cve@mitre.orghttp://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html
cve@mitre.orghttp://securityreason.com/securityalert/1293
cve@mitre.orghttp://securitytracker.com/id?1016582
cve@mitre.orghttp://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html
cve@mitre.orghttp://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html
cve@mitre.orghttp://www.osvdb.org/29068
cve@mitre.orghttp://www.securityfocus.com/archive/1/441203/100/0/threaded
cve@mitre.orghttp://www.securityfocus.com/bid/19176
cve@mitre.orghttps://exchange.xforce.ibmcloud.com/vulnerabilities/27972
cve@mitre.orghttps://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299
af854a3a-2127-422b-91ae-364da2661108http://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html
af854a3a-2127-422b-91ae-364da2661108http://securityreason.com/securityalert/1293
af854a3a-2127-422b-91ae-364da2661108http://securitytracker.com/id?1016582
af854a3a-2127-422b-91ae-364da2661108http://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html
af854a3a-2127-422b-91ae-364da2661108http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html
af854a3a-2127-422b-91ae-364da2661108http://www.osvdb.org/29068
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/archive/1/441203/100/0/threaded
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/19176
af854a3a-2127-422b-91ae-364da2661108https://exchange.xforce.ibmcloud.com/vulnerabilities/27972
af854a3a-2127-422b-91ae-364da2661108https://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299
Impacted products
Vendor Product Version
cisco ios *
cisco vpn_3001_concentrator *
cisco vpn_3015_concentrator *
cisco vpn_3020_concentrator *
cisco vpn_3030_concentator *
cisco vpn_3060_concentrator *
cisco vpn_3080_concentrator *
cisco adaptive_security_appliance_software 7.0
cisco adaptive_security_appliance_software 7.0\(4\)
cisco adaptive_security_appliance_software 7.0\(5\)
cisco adaptive_security_appliance_software 7.0.1.4
cisco adaptive_security_appliance_software 7.0.4.3
cisco adaptive_security_appliance_software 7.1\(2\)
cisco vpn_3000_concentrator_series_software 2.0
cisco vpn_3000_concentrator_series_software 2.5.2.a
cisco vpn_3000_concentrator_series_software 2.5.2.b
cisco vpn_3000_concentrator_series_software 2.5.2.c
cisco vpn_3000_concentrator_series_software 2.5.2.d
cisco vpn_3000_concentrator_series_software 2.5.2.f
cisco vpn_3000_concentrator_series_software 3.0
cisco vpn_3000_concentrator_series_software 3.0.3.a
cisco vpn_3000_concentrator_series_software 3.0.3.b
cisco vpn_3000_concentrator_series_software 3.0.4
cisco vpn_3000_concentrator_series_software 3.1
cisco vpn_3000_concentrator_series_software 3.1\(rel\)
cisco vpn_3000_concentrator_series_software 3.1.1
cisco vpn_3000_concentrator_series_software 3.1.2
cisco vpn_3000_concentrator_series_software 3.1.4
cisco vpn_3000_concentrator_series_software 3.5\(rel\)
cisco vpn_3000_concentrator_series_software 3.5.1
cisco vpn_3000_concentrator_series_software 3.5.2
cisco vpn_3000_concentrator_series_software 3.5.3
cisco vpn_3000_concentrator_series_software 3.5.4
cisco vpn_3000_concentrator_series_software 3.5.5
cisco vpn_3000_concentrator_series_software 3.6
cisco vpn_3000_concentrator_series_software 3.6.1
cisco vpn_3000_concentrator_series_software 3.6.3
cisco vpn_3000_concentrator_series_software 3.6.5
cisco vpn_3000_concentrator_series_software 3.6.7
cisco vpn_3000_concentrator_series_software 3.6.7.a
cisco vpn_3000_concentrator_series_software 3.6.7.b
cisco vpn_3000_concentrator_series_software 3.6.7.c
cisco vpn_3000_concentrator_series_software 3.6.7.d
cisco vpn_3000_concentrator_series_software 3.6.7.f
cisco vpn_3000_concentrator_series_software 3.6.7d
cisco vpn_3000_concentrator_series_software 4.0
cisco vpn_3000_concentrator_series_software 4.0.1
cisco vpn_3000_concentrator_series_software 4.0.2
cisco vpn_3000_concentrator_series_software 4.0.5.b
cisco vpn_3000_concentrator_series_software 4.1
cisco vpn_3000_concentrator_series_software 4.1.5.b
cisco vpn_3000_concentrator_series_software 4.1.7.a
cisco vpn_3000_concentrator_series_software 4.1.7.b
cisco vpn_3000_concentrator_series_software 4.1.7.l
cisco vpn_3000_concentrator_series_software 4.7
cisco vpn_3000_concentrator_series_software 4.7\(rel\)
cisco vpn_3000_concentrator_series_software 4.7.1
cisco vpn_3000_concentrator_series_software 4.7.1.f
cisco vpn_3000_concentrator_series_software 4.7.2
cisco vpn_3000_concentrator_series_software 4.7.2.a
cisco vpn_3000_concentrator_series_software 4.7.2.f
cisco vpn_3005_concentrator_software 4.0.1
cisco vpn_3030_concentator 4.7\(rel\)
cisco vpn_3030_concentator 4.7.1
cisco vpn_3030_concentator 4.7.1.f
cisco vpn_3030_concentator 4.7.2
cisco vpn_3030_concentator 4.7.2.a
cisco vpn_3030_concentator 4.7.2.f
cisco pix_asa_ids *
cisco pix_firewall 6.2.2_.111
cisco pix_firewall 6.2.3_\(110\)
cisco pix_firewall 6.3.3_\(133\)
cisco pix_firewall 6.3.5_\(112\)
cisco pix_firewall_501 *
cisco pix_firewall_506 *
cisco pix_firewall_515 *
cisco pix_firewall_515e *
cisco pix_firewall_520 *
cisco pix_firewall_525 *
cisco pix_firewall_535 *
cisco secure_pix_firewall *
cisco pix_firewall_software 2.7
cisco pix_firewall_software 3.0
cisco pix_firewall_software 3.1
cisco pix_firewall_software 4.0
cisco pix_firewall_software 4.1\(6\)
cisco pix_firewall_software 4.1\(6b\)
cisco pix_firewall_software 4.2
cisco pix_firewall_software 4.2\(1\)
cisco pix_firewall_software 4.2\(2\)
cisco pix_firewall_software 4.2\(5\)
cisco pix_firewall_software 4.3
cisco pix_firewall_software 4.4
cisco pix_firewall_software 4.4\(4\)
cisco pix_firewall_software 4.4\(7.202\)
cisco pix_firewall_software 4.4\(8\)
cisco pix_firewall_software 5.0
cisco pix_firewall_software 5.1
cisco pix_firewall_software 5.1\(4\)
cisco pix_firewall_software 5.1\(4.206\)
cisco pix_firewall_software 5.2
cisco pix_firewall_software 5.2\(1\)
cisco pix_firewall_software 5.2\(2\)
cisco pix_firewall_software 5.2\(3.210\)
cisco pix_firewall_software 5.2\(5\)
cisco pix_firewall_software 5.2\(6\)
cisco pix_firewall_software 5.2\(7\)
cisco pix_firewall_software 5.2\(9\)
cisco pix_firewall_software 5.3
cisco pix_firewall_software 5.3\(1\)
cisco pix_firewall_software 5.3\(1.200\)
cisco pix_firewall_software 5.3\(2\)
cisco pix_firewall_software 5.3\(3\)
cisco pix_firewall_software 6.0
cisco pix_firewall_software 6.0\(1\)
cisco pix_firewall_software 6.0\(2\)
cisco pix_firewall_software 6.0\(3\)
cisco pix_firewall_software 6.0\(4\)
cisco pix_firewall_software 6.0\(4.101\)
cisco pix_firewall_software 6.1
cisco pix_firewall_software 6.1\(1\)
cisco pix_firewall_software 6.1\(2\)
cisco pix_firewall_software 6.1\(3\)
cisco pix_firewall_software 6.1\(4\)
cisco pix_firewall_software 6.1\(5\)
cisco pix_firewall_software 6.1.5\(104\)
cisco pix_firewall_software 6.2
cisco pix_firewall_software 6.2\(1\)
cisco pix_firewall_software 6.2\(2\)
cisco pix_firewall_software 6.2\(3\)
cisco pix_firewall_software 6.2\(3.100\)
cisco pix_firewall_software 6.3
cisco pix_firewall_software 6.3\(1\)
cisco pix_firewall_software 6.3\(2\)
cisco pix_firewall_software 6.3\(3\)
cisco pix_firewall_software 6.3\(3.102\)
cisco pix_firewall_software 6.3\(3.109\)
cisco pix_firewall_software 6.3\(5\)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ios:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5802E2D8-7069-474C-826F-AEE7B50BFE34",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3001_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786346D5-13D8-45C9-B91D-C2AACF675377",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3020_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5D50FE2-A4E6-4EF4-A91C-88FB0AF6CCB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "85ED2D96-5CC9-4851-986A-C9ED5E2D96CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "AC150564-7413-401A-9DD8-8AD773F1D8F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D0714F9E-75AD-4405-BBC3-E0D817C05EF6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EA0DDDD-C987-4DA6-ADEE-77B387C26A92",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0.4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "49696766-ECCE-4903-AA54-271EFEA58B8D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.1\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D1557499-D1A1-4A26-80DA-A3D66AA53580",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "923949D1-06EC-462F-A3BC-FCAB448042A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "901B1838-7169-41E5-80EF-29BB680BF937",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAEAA5F-0A98-48B7-8012-9B9909243135",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "11DA4B03-2D30-4514-9DF5-5F0DDD4B8DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB38834B-E4AB-43F4-888B-14B088C95594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "23F8059B-3968-4D63-B1B3-74E545C918D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "701CDA0D-F932-4251-B484-8F20F0AE9003",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "E674AA43-905E-40E0-A70F-77D05C62C18D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0D767F-7142-46D2-B3E4-7FE8E9E3285A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "057A6BA0-5F5E-4FC4-B2EC-A17968EAC2C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "645AB682-2965-4C8D-B323-AB510E424407",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "76F7F019-A0A4-49CD-BB28-24BF7725AC89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "175CD875-3402-4B06-A3FA-7DFFCBB44056",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF61B8A5-31E7-40F5-8B3D-CA90E50618AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C9017BB-5848-4361-ABB9-C69FB3AB90FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF5F3FA-5FA4-408E-BA62-3943C5DFD859",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2AFAF42-B894-4D62-A9CF-3349A43191AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE5BB7F-D8B4-441B-9F45-56F622EEAA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B87A7EC-DC23-4075-8C4A-2317FF34BDB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "98AC18E3-D12B-489D-9D95-6C9210235FB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9DB969E-8BE9-46E0-B8AA-5057E320F1ED",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7d:*:*:*:*:*:*:*",
              "matchCriteriaId": "36291ADE-3D5A-4E49-8BA7-B71CAAA226B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D953DA9F-B54E-4941-85BE-48933C98DB55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E298AD-26AC-4E1D-83D8-5C2016CC6559",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "590283B1-4965-44D3-A0D4-CD90DD6B2D2A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "B71DAF71-5763-44D8-AD1E-5ADE8BC15120",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B35B6FA9-E504-4CE3-B171-815291A812CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFA54782-93A8-47BE-863D-89CA3678BF6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "67F66A10-246D-447B-941F-F1175684F0D6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "82435757-D892-4298-9176-5EC1FEC93037",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.l:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5BAFC4A-D8FB-4450-BC29-83B306000C99",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "D03F5D3F-6FB1-4A25-B544-D3C973F35DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "432A18AD-A495-4750-85A5-7D82FC321D7B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A90348C-94E2-4F04-A887-E7EFFC1ACF12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.1.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F5E136E-9215-46A8-A40A-AE964C588A38",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9729CAA-8041-43D6-9299-07CCCBFD3907",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "45A33500-B013-4863-BF12-27283ACD4AB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "A13F7BC2-7491-4266-9B32-3E6D8978A6C7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3005_concentrator_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "17196F00-9D7A-4AF6-AE1E-EA2E450A8ABD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "A459B6C2-EE91-43AE-A837-BCF4188BEB40",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "32200DE2-71BA-417C-AF24-3BE549A68711",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.1.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "25F3F37E-4BBD-4A0E-A1DF-64602D75207D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0722179-9602-42A1-81CA-062D4010B9CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA0E5615-4855-4A35-BE58-B9B27C7B2CC1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "65D48968-68F5-49BD-88CF-6C8D73D7F967",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:pix_asa_ids:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "701810DC-0A46-4D01-90BD-03AAF277E4DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.2.2_.111:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECBC761F-A8F5-4CD8-B19C-5CE8FFC58FDD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.2.3_\\(110\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "900DC321-4CEF-4810-8247-B82FE93F48BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.3.3_\\(133\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "422F8E64-2376-4E82-A1A2-916BFB7172AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.3.5_\\(112\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "54389797-86AA-4744-AA84-9B66FB6E01E3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_501:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "151D5A44-2D0D-478A-B011-A0892817B814",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_506:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E346F334-9BA3-4BDC-8D0F-D749A7D76E66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_515:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6EE5C14-F556-48A5-BB3F-5465DC823B85",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_515e:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "286199EA-71CF-46B4-9131-F1752C2EA82D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_520:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32E437F4-1B19-4B57-9EAD-3AC04717E389",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_525:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29B2019F-DF6E-4924-B0D2-37094B5265F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_535:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9600B7CF-4AEB-4319-8EF4-4FEA40EF6367",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:secure_pix_firewall:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "507B3A76-3F01-4BF0-8A3B-9E620DCB082D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:2.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "026A2C0D-AD93-49DC-AF72-8C12AD565B2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "920FAF7C-2964-497B-B1F8-3B060AAB4C55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D499F38-A34C-44D0-A061-C3AE08CF178B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "63E564B5-A39F-4837-93B8-1331CD975D4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.1\\(6\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "1EEDB9DD-C862-4783-9F96-88836424B298",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.1\\(6b\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3BD36C4A-4B90-4012-B4A5-6081C413E302",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "C39A993C-5A36-4D3F-B8B6-9B3252713127",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B1C4F7D5-DCD0-409C-86BF-A96A5253DF64",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "8198D129-76D0-4983-BFC4-8EC724FE1B6A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEECFAA-9DD5-4950-B9F1-CF8582225314",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "49566EAC-05AF-4880-8000-351AF538E4CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "23E9FBEE-3213-47FA-8CBA-C285533265FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "118CBF59-DAD8-468E-B279-F6359E4624F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4\\(7.202\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "957E6F8F-6881-44DE-A687-9D1E0C13F6CE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4\\(8\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E56328FE-F499-4325-AFEC-45BFEAB7662D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AA2E425-904C-4070-8F5F-B81BCF3147F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "604CF950-5D4B-4DC6-819E-0528B22CB05C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.1\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E12887E5-A2BB-4B1E-9621-2961458BCE21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.1\\(4.206\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3B5BE2F7-687C-477B-818B-A102526DF36D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "999A0969-60EB-4B2E-A274-9F05D9F840E5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "626E41D2-A5EF-493D-9486-3D9BC3793EAC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "EBA31E4D-2215-4E4A-BCCC-B3D922CB752D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(3.210\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "4F16AD2C-1CC1-43D9-A944-F67071B62E66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "A42FFBF7-9ADB-4F14-BED8-F2E53BEE7B62",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(6\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "25D16481-CA9A-4B4D-AC9D-3A4F0387FF19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(7\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "56E4588E-6C1F-4720-8082-0EF299435CB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(9\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D24E0E92-59D7-4B16-8B0D-2FD0EE821D93",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED24C763-7558-4AC0-AE10-FDA3D3078D27",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "4CC85ED3-B598-4A87-A2B8-8D3B52ECC2F0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(1.200\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "C84CE24E-4ED6-43D0-A234-FBD24D22A8A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "FF84B9FE-7C6C-4578-A5A9-EF0D5EEEEC19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "72C3E2B4-3A36-44B5-90D3-1BF9FAD98579",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "58BE9C02-2A01-4F6F-A6BD-BC0173561E9B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "C558CED8-8342-46CB-9F52-580B626D320E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "0F85D19E-6C26-429D-B876-F34238B9DAAF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "FEC7CCF7-CBC6-4EDC-8EDD-884DFFFBCC7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E5011A33-CD6D-4EFC-ACFD-E51C9AE726A3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(4.101\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "09063867-0E64-4630-B35B-4CCA348E4DAB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F98CD7-A352-483C-9968-8FB2627A7CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "F97FE485-705F-4707-B6C6-0EF9E8A85D5F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E2B925E8-D2C2-4E8C-AC21-0C422245C482",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B9170562-872E-4C32-869C-B10FF35A925E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D0927A68-8BB2-4F03-8396-E9CACC158FC0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "559DDBA3-2AF4-4A0C-B219-6779BA931F21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1.5\\(104\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "F76AED68-8304-4BC6-9D98-64231B08A6A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED9D142A-DDC8-4BD6-8C22-F242C9C0B1ED",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "5226C9CC-6933-4F10-B426-B47782C606FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "757DAE9A-B25D-4B8A-A41B-66C2897B537E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "5E3DC170-E279-4725-B9EE-6840B5685CC9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(3.100\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "8091EDA9-BD18-47F7-8CEC-E086238647C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F867890-74A4-4892-B99A-27DB4603B873",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "CE05B514-F094-4632-B25B-973F976F6409",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3392428D-1A85-4472-A276-C482A78E2CE1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B0D74D2C-662B-4D24-89EE-3DB73F96BBF5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(3.102\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "40954985-16E6-4F37-B014-6A55166AE093",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(3.109\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "0C097809-1FEF-4417-A201-42291CC29122",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "5E6D5FD3-CF95-4A3B-9ADB-CEC77F73CA78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Internet Key Exchange (IKE) version 1 protocol, as implemented on Cisco IOS, VPN 3000 Concentrators, and PIX firewalls, allows remote attackers to cause a denial of service (resource exhaustion) via a flood of IKE Phase-1 packets that exceed the session expiration rate. NOTE: it has been argued that this is due to a design weakness of the IKE version 1 protocol, in which case other vendors and implementations would also be affected."
    },
    {
      "lang": "es",
      "value": "Protocolo Internet Key Exchange (IKE) version 1, implementado para Cisco IOS, VPN 3000 Concentrators, y PIX firewalls, permite a atacantes remotos provocar denegaci\u00f3n de servicio (agotamiento de recursos) a trav\u00e9s de un flood de paquetes IKE Phase-1 que exceden el ratio de expiraci\u00f3n de la sesi\u00f3n. NOTA: se ha indicado que esto es debido a un dise\u00f1o debil del protocolo IKe version 1, en cuyo caso otros vendedores e implementaciones podr\u00edan verse afectados."
    }
  ],
  "id": "CVE-2006-3906",
  "lastModified": "2024-11-21T00:14:40.813",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2006-07-27T22:04:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://securityreason.com/securityalert/1293"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://securitytracker.com/id?1016582"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.osvdb.org/29068"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/archive/1/441203/100/0/threaded"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/19176"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/27972"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://archives.neohapsis.com/archives/bugtraq/2006-07/0531.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://securityreason.com/securityalert/1293"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://securitytracker.com/id?1016582"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.cisco.com/en/US/tech/tk583/tk372/tsd_technology_security_response09186a00806f33d4.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.nta-monitor.com/posts/2006/07/cisco-concentrator-dos.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.osvdb.org/29068"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/archive/1/441203/100/0/threaded"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/19176"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/27972"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://oval.cisecurity.org/repository/search/definition/oval%3Aorg.mitre.oval%3Adef%3A5299"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2010-11-30 22:14
Modified
2024-11-21 01:20
Severity ?
Summary
The remote-access IPSec VPN implementation on Cisco Adaptive Security Appliances (ASA) 5500 series devices, PIX Security Appliances 500 series devices, and VPN Concentrators 3000 series devices responds to an Aggressive Mode IKE Phase I message only when the group name is configured on the device, which allows remote attackers to enumerate valid group names via a series of IKE negotiation attempts, aka Bug ID CSCtj96108, a different vulnerability than CVE-2005-2025.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:asa_5500:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FCBA3A3-7C8F-481A-9BEC-78981547F8BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:pix_500:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2706D3BA-37A2-4D71-94DD-5386F5C94374",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3000_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24BE2649-D823-486B-8F6C-4B8128EC2795",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3005_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E098419B-1B9E-4191-9C72-65CE43E38F3B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3020_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5D50FE2-A4E6-4EF4-A91C-88FB0AF6CCB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The remote-access IPSec VPN implementation on Cisco Adaptive Security Appliances (ASA) 5500 series devices, PIX Security Appliances 500 series devices, and VPN Concentrators 3000 series devices responds to an Aggressive Mode IKE Phase I message only when the group name is configured on the device, which allows remote attackers to enumerate valid group names via a series of IKE negotiation attempts, aka Bug ID CSCtj96108, a different vulnerability than CVE-2005-2025."
    },
    {
      "lang": "es",
      "value": "La implementaci\u00f3n del acceso remoto de IPSec VPN en las series de dispositivos Cisco Adaptive Security Appliances (ASA) 5500, PIX Security Appliances 500 , y concentradores VPN 3000 responden a un mensaje \u0027Aggressive Mode IKE Phase I\u0027 s\u00f3lo cuando el nombre del grupo est\u00e1 configurado en el dispositivo, lo que permite enumerar los nombres v\u00e1lidos de grupo a atacantes remotos a trav\u00e9s de una serie de intentos de negociaci\u00f3n IKE. Este fallo tambi\u00e9n conocido como ID CSCtj96108. Se trata de una vulnerabilidad diferente a CVE-2005-2025.\r\n"
    }
  ],
  "id": "CVE-2010-4354",
  "lastModified": "2024-11-21T01:20:45.830",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2010-11-30T22:14:00.913",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/en/US/products/products_security_response09186a0080b5992c.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/en/US/products/products_security_response09186a0080b5992c.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2005-12-22 11:03
Modified
2024-11-21 00:04
Severity ?
Summary
The Downloadable RADIUS ACLs feature in Cisco PIX and VPN 3000 concentrators, when creating an ACL on the Cisco Secure Access Control Server (CS ACS), generates a random internal name for an ACL that is also used as a hidden user name and password, which allows remote attackers to gain privileges by sniffing the username from the cleartext portion of a RADIUS session, then using the password to log in to another device that uses CS ACS.
Impacted products
Vendor Product Version
cisco vpn_3001_concentrator *
cisco vpn_3015_concentrator *
cisco vpn_3020_concentrator *
cisco vpn_3030_concentator *
cisco vpn_3060_concentrator *
cisco vpn_3080_concentrator *
cisco adaptive_security_appliance_software 7.0
cisco adaptive_security_appliance_software 7.0\(4\)
cisco adaptive_security_appliance_software 7.0.1.4
cisco adaptive_security_appliance_software 7.0.4.3
cisco vpn_3000_concentrator_series_software 2.0
cisco vpn_3000_concentrator_series_software 2.5.2.a
cisco vpn_3000_concentrator_series_software 2.5.2.b
cisco vpn_3000_concentrator_series_software 2.5.2.c
cisco vpn_3000_concentrator_series_software 2.5.2.d
cisco vpn_3000_concentrator_series_software 2.5.2.f
cisco vpn_3000_concentrator_series_software 3.0
cisco vpn_3000_concentrator_series_software 3.0.3.a
cisco vpn_3000_concentrator_series_software 3.0.3.b
cisco vpn_3000_concentrator_series_software 3.0.4
cisco vpn_3000_concentrator_series_software 3.1
cisco vpn_3000_concentrator_series_software 3.1\(rel\)
cisco vpn_3000_concentrator_series_software 3.1.1
cisco vpn_3000_concentrator_series_software 3.1.2
cisco vpn_3000_concentrator_series_software 3.1.4
cisco vpn_3000_concentrator_series_software 3.5\(rel\)
cisco vpn_3000_concentrator_series_software 3.5.1
cisco vpn_3000_concentrator_series_software 3.5.2
cisco vpn_3000_concentrator_series_software 3.5.3
cisco vpn_3000_concentrator_series_software 3.5.4
cisco vpn_3000_concentrator_series_software 3.5.5
cisco vpn_3000_concentrator_series_software 3.6
cisco vpn_3000_concentrator_series_software 3.6.1
cisco vpn_3000_concentrator_series_software 3.6.3
cisco vpn_3000_concentrator_series_software 3.6.5
cisco vpn_3000_concentrator_series_software 3.6.7
cisco vpn_3000_concentrator_series_software 3.6.7.a
cisco vpn_3000_concentrator_series_software 3.6.7.b
cisco vpn_3000_concentrator_series_software 3.6.7.c
cisco vpn_3000_concentrator_series_software 3.6.7.d
cisco vpn_3000_concentrator_series_software 3.6.7.f
cisco vpn_3000_concentrator_series_software 3.6.7d
cisco vpn_3000_concentrator_series_software 4.0
cisco vpn_3000_concentrator_series_software 4.0.1
cisco vpn_3000_concentrator_series_software 4.0.2
cisco vpn_3000_concentrator_series_software 4.0.5.b
cisco vpn_3000_concentrator_series_software 4.1.5.b
cisco vpn_3000_concentrator_series_software 4.1.7.a
cisco vpn_3000_concentrator_series_software 4.1.7.b
cisco vpn_3000_concentrator_series_software 4.7.1
cisco vpn_3000_concentrator_series_software 4.7.1.f
cisco vpn_3005_concentrator_software 4.0.1
cisco vpn_3030_concentator 4.7.1
cisco vpn_3030_concentator 4.7.1.f
cisco pix_asa_ids *
cisco pix_firewall 6.2.2_.111
cisco pix_firewall 6.2.3_\(110\)
cisco pix_firewall 6.3.3_\(133\)
cisco secure_access_control_server *
cisco secure_access_control_server 2.0
cisco secure_access_control_server 2.1
cisco secure_access_control_server 2.3
cisco secure_access_control_server 2.3
cisco secure_access_control_server 2.3.5.1
cisco secure_access_control_server 2.3.6.1
cisco secure_access_control_server 2.4
cisco secure_access_control_server 2.5
cisco secure_access_control_server 2.6
cisco secure_access_control_server 2.6.2
cisco secure_access_control_server 2.6.3
cisco secure_access_control_server 2.6.4
cisco secure_access_control_server 2.42
cisco secure_access_control_server 3.0
cisco secure_access_control_server 3.0
cisco secure_access_control_server 3.0.1
cisco secure_access_control_server 3.0.3
cisco secure_access_control_server 3.1
cisco secure_access_control_server 3.1.1
cisco secure_access_control_server 3.2
cisco secure_access_control_server 3.2
cisco secure_access_control_server 3.2\(1\)
cisco secure_access_control_server 3.2\(1.20\)
cisco secure_access_control_server 3.2\(2\)
cisco secure_access_control_server 3.2\(3\)
cisco secure_access_control_server 3.2.1
cisco secure_access_control_server 3.2.2
cisco secure_access_control_server 3.3
cisco secure_access_control_server 3.3\(1\)
cisco secure_access_control_server 3.3.1
cisco secure_access_control_server 3.3.2
cisco vpn_3002_hardware_client *
cisco pix_firewall_501 *
cisco pix_firewall_506 *
cisco pix_firewall_515 *
cisco pix_firewall_515e *
cisco pix_firewall_520 *
cisco pix_firewall_525 *
cisco pix_firewall_535 *
cisco pix_firewall *
cisco pix_firewall_software 2.7
cisco pix_firewall_software 3.0
cisco pix_firewall_software 3.1
cisco pix_firewall_software 4.0
cisco pix_firewall_software 4.1\(6\)
cisco pix_firewall_software 4.1\(6b\)
cisco pix_firewall_software 4.2
cisco pix_firewall_software 4.2\(1\)
cisco pix_firewall_software 4.2\(2\)
cisco pix_firewall_software 4.2\(5\)
cisco pix_firewall_software 4.3
cisco pix_firewall_software 4.4
cisco pix_firewall_software 4.4\(4\)
cisco pix_firewall_software 4.4\(7.202\)
cisco pix_firewall_software 4.4\(8\)
cisco pix_firewall_software 5.0
cisco pix_firewall_software 5.1
cisco pix_firewall_software 5.1\(4\)
cisco pix_firewall_software 5.1\(4.206\)
cisco pix_firewall_software 5.2
cisco pix_firewall_software 5.2\(1\)
cisco pix_firewall_software 5.2\(2\)
cisco pix_firewall_software 5.2\(3.210\)
cisco pix_firewall_software 5.2\(5\)
cisco pix_firewall_software 5.2\(6\)
cisco pix_firewall_software 5.2\(7\)
cisco pix_firewall_software 5.2\(9\)
cisco pix_firewall_software 5.3
cisco pix_firewall_software 5.3\(1\)
cisco pix_firewall_software 5.3\(1.200\)
cisco pix_firewall_software 5.3\(2\)
cisco pix_firewall_software 5.3\(3\)
cisco pix_firewall_software 6.0
cisco pix_firewall_software 6.0\(1\)
cisco pix_firewall_software 6.0\(2\)
cisco pix_firewall_software 6.0\(3\)
cisco pix_firewall_software 6.0\(4\)
cisco pix_firewall_software 6.0\(4.101\)
cisco pix_firewall_software 6.1
cisco pix_firewall_software 6.1\(1\)
cisco pix_firewall_software 6.1\(2\)
cisco pix_firewall_software 6.1\(3\)
cisco pix_firewall_software 6.1\(4\)
cisco pix_firewall_software 6.1\(5\)
cisco pix_firewall_software 6.1.5\(104\)
cisco pix_firewall_software 6.2
cisco pix_firewall_software 6.2\(1\)
cisco pix_firewall_software 6.2\(2\)
cisco pix_firewall_software 6.2\(3\)
cisco pix_firewall_software 6.2\(3.100\)
cisco pix_firewall_software 6.3
cisco pix_firewall_software 6.3\(1\)
cisco pix_firewall_software 6.3\(2\)
cisco pix_firewall_software 6.3\(3\)
cisco pix_firewall_software 6.3\(3.102\)
cisco pix_firewall_software 6.3\(3.109\)
cisco pix_firewall_software 6.3\(5\)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3001_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786346D5-13D8-45C9-B91D-C2AACF675377",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3020_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5D50FE2-A4E6-4EF4-A91C-88FB0AF6CCB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "85ED2D96-5CC9-4851-986A-C9ED5E2D96CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "AC150564-7413-401A-9DD8-8AD773F1D8F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EA0DDDD-C987-4DA6-ADEE-77B387C26A92",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:adaptive_security_appliance_software:7.0.4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "49696766-ECCE-4903-AA54-271EFEA58B8D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "923949D1-06EC-462F-A3BC-FCAB448042A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "901B1838-7169-41E5-80EF-29BB680BF937",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAEAA5F-0A98-48B7-8012-9B9909243135",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "11DA4B03-2D30-4514-9DF5-5F0DDD4B8DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB38834B-E4AB-43F4-888B-14B088C95594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "23F8059B-3968-4D63-B1B3-74E545C918D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "701CDA0D-F932-4251-B484-8F20F0AE9003",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "E674AA43-905E-40E0-A70F-77D05C62C18D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0D767F-7142-46D2-B3E4-7FE8E9E3285A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "057A6BA0-5F5E-4FC4-B2EC-A17968EAC2C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "645AB682-2965-4C8D-B323-AB510E424407",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "76F7F019-A0A4-49CD-BB28-24BF7725AC89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "175CD875-3402-4B06-A3FA-7DFFCBB44056",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF61B8A5-31E7-40F5-8B3D-CA90E50618AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C9017BB-5848-4361-ABB9-C69FB3AB90FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF5F3FA-5FA4-408E-BA62-3943C5DFD859",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2AFAF42-B894-4D62-A9CF-3349A43191AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE5BB7F-D8B4-441B-9F45-56F622EEAA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B87A7EC-DC23-4075-8C4A-2317FF34BDB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "98AC18E3-D12B-489D-9D95-6C9210235FB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9DB969E-8BE9-46E0-B8AA-5057E320F1ED",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7d:*:*:*:*:*:*:*",
              "matchCriteriaId": "36291ADE-3D5A-4E49-8BA7-B71CAAA226B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D953DA9F-B54E-4941-85BE-48933C98DB55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E298AD-26AC-4E1D-83D8-5C2016CC6559",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "590283B1-4965-44D3-A0D4-CD90DD6B2D2A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "B71DAF71-5763-44D8-AD1E-5ADE8BC15120",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFA54782-93A8-47BE-863D-89CA3678BF6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "67F66A10-246D-447B-941F-F1175684F0D6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "82435757-D892-4298-9176-5EC1FEC93037",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A90348C-94E2-4F04-A887-E7EFFC1ACF12",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.7.1.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F5E136E-9215-46A8-A40A-AE964C588A38",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3005_concentrator_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "17196F00-9D7A-4AF6-AE1E-EA2E450A8ABD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "32200DE2-71BA-417C-AF24-3BE549A68711",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3030_concentator:4.7.1.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "25F3F37E-4BBD-4A0E-A1DF-64602D75207D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:pix_asa_ids:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "701810DC-0A46-4D01-90BD-03AAF277E4DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.2.2_.111:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECBC761F-A8F5-4CD8-B19C-5CE8FFC58FDD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.2.3_\\(110\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "900DC321-4CEF-4810-8247-B82FE93F48BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:pix_firewall:6.3.3_\\(133\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "422F8E64-2376-4E82-A1A2-916BFB7172AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE5C8F8B-4F20-4635-81FF-92F144F43793",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.0:*:unix:*:*:*:*:*",
              "matchCriteriaId": "22B6CD99-5B21-4961-AD47-B1722E586664",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.1:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "3BF391B2-17C6-4633-8CE9-35B637BFDC79",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.3:*:unix:*:*:*:*:*",
              "matchCriteriaId": "7889030E-97F7-4CCD-8050-5250B1F58C26",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.3:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "26B0CB70-CC82-4FF1-882C-0712354DA113",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.3.5.1:*:unix:*:*:*:*:*",
              "matchCriteriaId": "543A3774-28EB-406D-830E-957B5E9E7A66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.3.6.1:*:unix:*:*:*:*:*",
              "matchCriteriaId": "B0B5C19A-58BB-4A7A-886D-3567B37F466D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.4:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "4126D9DE-A75E-4A9E-9DA7-1477D5688872",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.5:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "0354C50C-4104-4960-B1EE-F212CD3D6AE5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.6:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "DE9B81AC-1D16-4FDF-B438-3D3ED2BE9538",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.6.2:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "8F515D7A-D663-49F0-8F12-1484000505FB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.6.3:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "A668278F-8080-4295-95EB-88341478D16B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.6.4:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "A66BED35-F385-4A0C-9416-6F007536133E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:2.42:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "5EA57609-522C-4431-92AE-4FF11AA67320",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "44D05855-C8C1-4243-8438-5A36A01A8F48",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.0:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "A60B49A7-B569-4485-A6B3-E14B9FB96950",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.0.1:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "FA889730-B2FF-4219-BBCA-A4364BA61EAF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.0.3:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "8731D5CC-A6F9-48DB-B1D1-FD50CEAC63D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB11A75E-2E4B-4B83-B763-CBBC1D9DFB36",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.1.1:*:windows_nt:*:*:*:*:*",
              "matchCriteriaId": "DFFE6A50-B704-42BB-8FFF-27E9F4D3B576",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "109147BF-3225-48E4-8BE1-2E5B59921032",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2:*:windows_server:*:*:*:*:*",
              "matchCriteriaId": "7CDA01B6-6887-40BB-B541-65F198D03219",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "86806D6E-1BDF-4253-AEB7-D9D88D224812",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2\\(1.20\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B0BD6882-379C-4EA7-8E51-124273C5A56F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "680E5A81-6409-4CE7-8496-D7845FD7E851",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3868E060-0278-491A-9943-1A2E435C7606",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "F39D3441-C84A-403A-ACB4-8019579EE4DB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.2.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "61ED039B-C3E6-4BC8-A97A-351EC9CEAF16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2793200-D95D-4BD3-8DF2-4A847230FBE5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.3\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "0E587654-B5A0-47A4-BED6-D8DB69AEF566",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F07B954-817F-47AC-BCAC-3DA697A6E2F2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:secure_access_control_server:3.3.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC1B599-05C0-4FB5-A47B-5D858DAB43A0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:cisco:vpn_3002_hardware_client:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12ECF578-84BF-4F41-9462-C09FA517F2A0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_501:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "151D5A44-2D0D-478A-B011-A0892817B814",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_506:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E346F334-9BA3-4BDC-8D0F-D749A7D76E66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_515:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6EE5C14-F556-48A5-BB3F-5465DC823B85",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_515e:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "286199EA-71CF-46B4-9131-F1752C2EA82D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_520:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32E437F4-1B19-4B57-9EAD-3AC04717E389",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_525:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29B2019F-DF6E-4924-B0D2-37094B5265F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:pix_firewall_535:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9600B7CF-4AEB-4319-8EF4-4FEA40EF6367",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2C5A417-C48D-4799-A766-7B231ADF27C7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:2.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "026A2C0D-AD93-49DC-AF72-8C12AD565B2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "920FAF7C-2964-497B-B1F8-3B060AAB4C55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D499F38-A34C-44D0-A061-C3AE08CF178B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "63E564B5-A39F-4837-93B8-1331CD975D4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.1\\(6\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "1EEDB9DD-C862-4783-9F96-88836424B298",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.1\\(6b\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3BD36C4A-4B90-4012-B4A5-6081C413E302",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "C39A993C-5A36-4D3F-B8B6-9B3252713127",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B1C4F7D5-DCD0-409C-86BF-A96A5253DF64",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "8198D129-76D0-4983-BFC4-8EC724FE1B6A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.2\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEECFAA-9DD5-4950-B9F1-CF8582225314",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "49566EAC-05AF-4880-8000-351AF538E4CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "23E9FBEE-3213-47FA-8CBA-C285533265FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "118CBF59-DAD8-468E-B279-F6359E4624F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4\\(7.202\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "957E6F8F-6881-44DE-A687-9D1E0C13F6CE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:4.4\\(8\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E56328FE-F499-4325-AFEC-45BFEAB7662D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AA2E425-904C-4070-8F5F-B81BCF3147F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "604CF950-5D4B-4DC6-819E-0528B22CB05C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.1\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E12887E5-A2BB-4B1E-9621-2961458BCE21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.1\\(4.206\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3B5BE2F7-687C-477B-818B-A102526DF36D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "999A0969-60EB-4B2E-A274-9F05D9F840E5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "626E41D2-A5EF-493D-9486-3D9BC3793EAC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "EBA31E4D-2215-4E4A-BCCC-B3D922CB752D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(3.210\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "4F16AD2C-1CC1-43D9-A944-F67071B62E66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "A42FFBF7-9ADB-4F14-BED8-F2E53BEE7B62",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(6\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "25D16481-CA9A-4B4D-AC9D-3A4F0387FF19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(7\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "56E4588E-6C1F-4720-8082-0EF299435CB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.2\\(9\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D24E0E92-59D7-4B16-8B0D-2FD0EE821D93",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED24C763-7558-4AC0-AE10-FDA3D3078D27",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "4CC85ED3-B598-4A87-A2B8-8D3B52ECC2F0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(1.200\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "C84CE24E-4ED6-43D0-A234-FBD24D22A8A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "FF84B9FE-7C6C-4578-A5A9-EF0D5EEEEC19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:5.3\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "72C3E2B4-3A36-44B5-90D3-1BF9FAD98579",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "58BE9C02-2A01-4F6F-A6BD-BC0173561E9B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "C558CED8-8342-46CB-9F52-580B626D320E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "0F85D19E-6C26-429D-B876-F34238B9DAAF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "FEC7CCF7-CBC6-4EDC-8EDD-884DFFFBCC7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E5011A33-CD6D-4EFC-ACFD-E51C9AE726A3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.0\\(4.101\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "09063867-0E64-4630-B35B-4CCA348E4DAB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F98CD7-A352-483C-9968-8FB2627A7CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "F97FE485-705F-4707-B6C6-0EF9E8A85D5F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "E2B925E8-D2C2-4E8C-AC21-0C422245C482",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B9170562-872E-4C32-869C-B10FF35A925E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(4\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D0927A68-8BB2-4F03-8396-E9CACC158FC0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "559DDBA3-2AF4-4A0C-B219-6779BA931F21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.1.5\\(104\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "F76AED68-8304-4BC6-9D98-64231B08A6A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED9D142A-DDC8-4BD6-8C22-F242C9C0B1ED",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "5226C9CC-6933-4F10-B426-B47782C606FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "757DAE9A-B25D-4B8A-A41B-66C2897B537E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "5E3DC170-E279-4725-B9EE-6840B5685CC9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.2\\(3.100\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "8091EDA9-BD18-47F7-8CEC-E086238647C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F867890-74A4-4892-B99A-27DB4603B873",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(1\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "CE05B514-F094-4632-B25B-973F976F6409",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(2\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3392428D-1A85-4472-A276-C482A78E2CE1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(3\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "B0D74D2C-662B-4D24-89EE-3DB73F96BBF5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(3.102\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "40954985-16E6-4F37-B014-6A55166AE093",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(3.109\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "0C097809-1FEF-4417-A201-42291CC29122",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:pix_firewall_software:6.3\\(5\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "5E6D5FD3-CF95-4A3B-9ADB-CEC77F73CA78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Downloadable RADIUS ACLs feature in Cisco PIX and VPN 3000 concentrators, when creating an ACL on the Cisco Secure Access Control Server (CS ACS), generates a random internal name for an ACL that is also used as a hidden user name and password, which allows remote attackers to gain privileges by sniffing the username from the cleartext portion of a RADIUS session, then using the password to log in to another device that uses CS ACS."
    }
  ],
  "id": "CVE-2005-4499",
  "lastModified": "2024-11-21T00:04:24.143",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": true,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2005-12-22T11:03:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://secunia.com/advisories/18141"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_field_notice09186a00805bf1c4.shtml"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.osvdb.org/22193"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/archive/1/420020/100/0/threaded"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/archive/1/420103/100/0/threaded"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/16025"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://secunia.com/advisories/18141"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_field_notice09186a00805bf1c4.shtml"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.osvdb.org/22193"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/archive/1/420020/100/0/threaded"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/archive/1/420103/100/0/threaded"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/16025"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2005-06-20 04:00
Modified
2024-11-20 23:58
Severity ?
Summary
Cisco VPN 3000 Concentrator before 4.1.7.F allows remote attackers to determine valid groupnames by sending an IKE Aggressive Mode packet with the groupname in the ID field, which generates a response if the groupname is valid, but does not generate a response for an invalid groupname.
Impacted products
Vendor Product Version
cisco vpn_3000_concentrator *
cisco vpn_3015_concentrator *
cisco vpn_3020_concentrator *
cisco vpn_3030_concentator *
cisco vpn_3060_concentrator *
cisco vpn_3080_concentrator *
cisco vpn_3000_concentrator_series_software 2.0
cisco vpn_3000_concentrator_series_software 2.5.2.a
cisco vpn_3000_concentrator_series_software 2.5.2.b
cisco vpn_3000_concentrator_series_software 2.5.2.c
cisco vpn_3000_concentrator_series_software 2.5.2.d
cisco vpn_3000_concentrator_series_software 2.5.2.f
cisco vpn_3000_concentrator_series_software 3.0
cisco vpn_3000_concentrator_series_software 3.0.3.a
cisco vpn_3000_concentrator_series_software 3.0.3.b
cisco vpn_3000_concentrator_series_software 3.0.4
cisco vpn_3000_concentrator_series_software 3.1\(rel\)
cisco vpn_3000_concentrator_series_software 3.1.1
cisco vpn_3000_concentrator_series_software 3.1.2
cisco vpn_3000_concentrator_series_software 3.1.4
cisco vpn_3000_concentrator_series_software 3.5\(rel\)
cisco vpn_3000_concentrator_series_software 3.5.1
cisco vpn_3000_concentrator_series_software 3.5.2
cisco vpn_3000_concentrator_series_software 3.5.3
cisco vpn_3000_concentrator_series_software 3.5.4
cisco vpn_3000_concentrator_series_software 3.5.5
cisco vpn_3000_concentrator_series_software 3.6.1
cisco vpn_3000_concentrator_series_software 3.6.3
cisco vpn_3000_concentrator_series_software 3.6.5
cisco vpn_3000_concentrator_series_software 3.6.7
cisco vpn_3000_concentrator_series_software 3.6.7.a
cisco vpn_3000_concentrator_series_software 3.6.7.b
cisco vpn_3000_concentrator_series_software 3.6.7.c
cisco vpn_3000_concentrator_series_software 3.6.7.d
cisco vpn_3000_concentrator_series_software 3.6.7.f
cisco vpn_3000_concentrator_series_software 3.6.7d
cisco vpn_3000_concentrator_series_software 4.0
cisco vpn_3000_concentrator_series_software 4.0.1
cisco vpn_3000_concentrator_series_software 4.0.5.b
cisco vpn_3000_concentrator_series_software 4.1
cisco vpn_3000_concentrator_series_software 4.1.5.b
cisco vpn_3000_concentrator_series_software 4.1.7.a
cisco vpn_3000_concentrator_series_software 4.1.7.b
cisco vpn_3005_concentrator_software 4.0.1



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3000_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24BE2649-D823-486B-8F6C-4B8128EC2795",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3020_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5D50FE2-A4E6-4EF4-A91C-88FB0AF6CCB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "923949D1-06EC-462F-A3BC-FCAB448042A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "901B1838-7169-41E5-80EF-29BB680BF937",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAEAA5F-0A98-48B7-8012-9B9909243135",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "11DA4B03-2D30-4514-9DF5-5F0DDD4B8DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB38834B-E4AB-43F4-888B-14B088C95594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "23F8059B-3968-4D63-B1B3-74E545C918D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "701CDA0D-F932-4251-B484-8F20F0AE9003",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "E674AA43-905E-40E0-A70F-77D05C62C18D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0D767F-7142-46D2-B3E4-7FE8E9E3285A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "057A6BA0-5F5E-4FC4-B2EC-A17968EAC2C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "76F7F019-A0A4-49CD-BB28-24BF7725AC89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "175CD875-3402-4B06-A3FA-7DFFCBB44056",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF61B8A5-31E7-40F5-8B3D-CA90E50618AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C9017BB-5848-4361-ABB9-C69FB3AB90FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2AFAF42-B894-4D62-A9CF-3349A43191AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE5BB7F-D8B4-441B-9F45-56F622EEAA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B87A7EC-DC23-4075-8C4A-2317FF34BDB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "98AC18E3-D12B-489D-9D95-6C9210235FB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9DB969E-8BE9-46E0-B8AA-5057E320F1ED",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7d:*:*:*:*:*:*:*",
              "matchCriteriaId": "36291ADE-3D5A-4E49-8BA7-B71CAAA226B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D953DA9F-B54E-4941-85BE-48933C98DB55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E298AD-26AC-4E1D-83D8-5C2016CC6559",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.0.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "B71DAF71-5763-44D8-AD1E-5ADE8BC15120",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B35B6FA9-E504-4CE3-B171-815291A812CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.5.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFA54782-93A8-47BE-863D-89CA3678BF6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "67F66A10-246D-447B-941F-F1175684F0D6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:4.1.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "82435757-D892-4298-9176-5EC1FEC93037",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3005_concentrator_software:4.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "17196F00-9D7A-4AF6-AE1E-EA2E450A8ABD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cisco VPN 3000 Concentrator before 4.1.7.F allows remote attackers to determine valid groupnames by sending an IKE Aggressive Mode packet with the groupname in the ID field, which generates a response if the groupname is valid, but does not generate a response for an invalid groupname."
    }
  ],
  "id": "CVE-2005-2025",
  "lastModified": "2024-11-20T23:58:37.943",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2005-06-20T04:00:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.nta-monitor.com/news/vpn-flaws/cisco/VPN-Concentrator/index.htm"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.securityfocus.com/bid/13992"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.vupen.com/english/advisories/2005/0822"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.nta-monitor.com/news/vpn-flaws/cisco/VPN-Concentrator/index.htm"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.securityfocus.com/bid/13992"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.vupen.com/english/advisories/2005/0822"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2003-05-27 04:00
Modified
2024-11-20 23:44
Severity ?
Summary
Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7 allows remote attackers to cause a denial of service (reload) via a malformed SSH initialization packet.
Impacted products
Vendor Product Version
cisco vpn_3015_concentrator *
cisco vpn_3030_concentator *
cisco vpn_3060_concentrator *
cisco vpn_3080_concentrator *
cisco vpn_3000_concentrator_series_software 2.0
cisco vpn_3000_concentrator_series_software 2.5.2.a
cisco vpn_3000_concentrator_series_software 2.5.2.b
cisco vpn_3000_concentrator_series_software 2.5.2.c
cisco vpn_3000_concentrator_series_software 2.5.2.d
cisco vpn_3000_concentrator_series_software 2.5.2.f
cisco vpn_3000_concentrator_series_software 3.0
cisco vpn_3000_concentrator_series_software 3.0.3.a
cisco vpn_3000_concentrator_series_software 3.0.3.b
cisco vpn_3000_concentrator_series_software 3.0.4
cisco vpn_3000_concentrator_series_software 3.1
cisco vpn_3000_concentrator_series_software 3.1\(rel\)
cisco vpn_3000_concentrator_series_software 3.1.1
cisco vpn_3000_concentrator_series_software 3.1.2
cisco vpn_3000_concentrator_series_software 3.1.4
cisco vpn_3000_concentrator_series_software 3.5\(rel\)
cisco vpn_3000_concentrator_series_software 3.5.1
cisco vpn_3000_concentrator_series_software 3.5.2
cisco vpn_3000_concentrator_series_software 3.5.3
cisco vpn_3000_concentrator_series_software 3.5.4
cisco vpn_3000_concentrator_series_software 3.5.5
cisco vpn_3000_concentrator_series_software 3.6
cisco vpn_3000_concentrator_series_software 3.6.1
cisco vpn_3000_concentrator_series_software 3.6.3
cisco vpn_3000_concentrator_series_software 3.6.5
cisco vpn_3000_concentrator_series_software 3.6.7
cisco vpn_3000_concentrator_series_software 3.6.7.a
cisco vpn_3000_concentrator_series_software 3.6.7.b
cisco vpn_3000_concentrator_series_software 3.6.7.c
cisco vpn_3000_concentrator_series_software 3.6.7.d
cisco vpn_3000_concentrator_series_software 3.6.7d
cisco vpn_3002_hardware_client *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3015_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A512328-2FD0-4B1D-9327-A13A0BCE9C0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3030_concentator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6548F964-B8EE-4B39-87CF-99743D41C42C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3060_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08810E6-33B6-45FF-91C7-EED10DC023EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:cisco:vpn_3080_concentrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD1A1AC-980F-428E-8BAF-0FC821014868",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "923949D1-06EC-462F-A3BC-FCAB448042A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "901B1838-7169-41E5-80EF-29BB680BF937",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAEAA5F-0A98-48B7-8012-9B9909243135",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "11DA4B03-2D30-4514-9DF5-5F0DDD4B8DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB38834B-E4AB-43F4-888B-14B088C95594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:2.5.2.f:*:*:*:*:*:*:*",
              "matchCriteriaId": "23F8059B-3968-4D63-B1B3-74E545C918D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "701CDA0D-F932-4251-B484-8F20F0AE9003",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "E674AA43-905E-40E0-A70F-77D05C62C18D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.3.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0D767F-7142-46D2-B3E4-7FE8E9E3285A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "057A6BA0-5F5E-4FC4-B2EC-A17968EAC2C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "645AB682-2965-4C8D-B323-AB510E424407",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "76F7F019-A0A4-49CD-BB28-24BF7725AC89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "175CD875-3402-4B06-A3FA-7DFFCBB44056",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF61B8A5-31E7-40F5-8B3D-CA90E50618AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.1.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C9017BB-5848-4361-ABB9-C69FB3AB90FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5\\(rel\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "207034E8-35F7-4E78-A3FC-C86D20EB8D9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C544E523-15E5-4CE5-8113-53454F5D9973",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B09F6EBD-C3FC-4680-BE31-A766D863237D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF8C3FDA-D321-4202-A8EA-6C1464558A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "B68705AB-A133-401F-9F41-64594E071816",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.5.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9092680-E154-4EAB-A2D5-B692073F894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF5F3FA-5FA4-408E-BA62-3943C5DFD859",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADFC9764-5BF5-449F-9200-5569C13F8309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12F2AAC-DB5B-4C28-86C5-F59490362E54",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "071F52AD-D59B-4673-BCBE-112B94D3EB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "80709CB0-D386-4C4F-B3EE-7A0501FD7248",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.a:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2AFAF42-B894-4D62-A9CF-3349A43191AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.b:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE5BB7F-D8B4-441B-9F45-56F622EEAA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.c:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B87A7EC-DC23-4075-8C4A-2317FF34BDB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7.d:*:*:*:*:*:*:*",
              "matchCriteriaId": "98AC18E3-D12B-489D-9D95-6C9210235FB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:cisco:vpn_3000_concentrator_series_software:3.6.7d:*:*:*:*:*:*:*",
              "matchCriteriaId": "36291ADE-3D5A-4E49-8BA7-B71CAAA226B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:cisco:vpn_3002_hardware_client:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12ECF578-84BF-4F41-9462-C09FA517F2A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cisco VPN 3000 series concentrators and Cisco VPN 3002 Hardware Client 2.x.x through 3.6.7 allows remote attackers to cause a denial of service (reload) via a malformed SSH initialization packet."
    },
    {
      "lang": "es",
      "value": "Concentradores de Cisco de la serie VPN 3000 y Cisco VPN 3002 Hardware Client 2.x.x hasta 3.6.7 permiten que atacantes remotos causen una denegaci\u00f3n de servicio (recarga) mediante un paquete de inicializaci\u00f3n SSH mal constru\u00eddo."
    }
  ],
  "id": "CVE-2003-0259",
  "lastModified": "2024-11-20T23:44:20.057",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2003-05-27T04:00:00.000",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/317348"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11955"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.cisco.com/warp/public/707/cisco-sa-20030507-vpn3k.shtml"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/317348"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/11955"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}