FKIE_CVE-2024-50696
Vulnerability from fkie_nvd - Published: 2025-02-26 21:15 - Updated: 2025-04-07 18:48
Severity ?
Summary
SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://en.sungrowpower.com/security-notice-detail-2/6140 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "271D759A-8B61-44BF-B164-792D2874CBC3",
"versionEndIncluding": "200.001.00.P025",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server."
},
{
"lang": "es",
"value": "SunGrow WiNet-S V200.001.00.P025 y las versiones anteriores les faltan comprobaciones de integridad para las actualizaciones de firmware. El env\u00edo de un mensaje MQTT espec\u00edfico permite una actualizaci\u00f3n de un inversor o un dispositivo de conectividad WiNet con un archivo de firmware falso que se encuentra en un servidor controlado por el atacante."
}
],
"id": "CVE-2024-50696",
"lastModified": "2025-04-07T18:48:52.107",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-02-26T21:15:17.997",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/6140"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-494"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-50697
Vulnerability from fkie_nvd - Published: 2025-01-24 23:15 - Updated: 2025-05-29 16:02
Severity ?
Summary
In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when decrypting MQTT messages, the code that parses specific TLV fields does not have sufficient bounds checks. This may result in a stack-based buffer overflow.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://en.sungrowpower.com/security-notice-detail-2/5961 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EC5C36C-0726-4C02-9C89-FC97EB06D144",
"versionEndExcluding": "200.001.00.p027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when decrypting MQTT messages, the code that parses specific TLV fields does not have sufficient bounds checks. This may result in a stack-based buffer overflow."
},
{
"lang": "es",
"value": "En SunGrow WiNet-SV200.001.00.P027 y versiones anteriores, al descifrar mensajes MQTT, el c\u00f3digo que analiza campos TLV espec\u00edficos no tiene suficientes comprobaciones de los l\u00edmites. Esto puede provocar un desbordamiento del b\u00fafer basado en la pila."
}
],
"id": "CVE-2024-50697",
"lastModified": "2025-05-29T16:02:02.670",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-24T23:15:09.253",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-50694
Vulnerability from fkie_nvd - Published: 2025-01-24 23:15 - Updated: 2025-05-29 16:02
Severity ?
Summary
In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when copying the timestamp read from an MQTT message, the underlying code does not check the bounds of the buffer that is used to store the message. This may lead to a stack-based buffer overflow.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://en.sungrowpower.com/security-notice-detail-2/5961 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EC5C36C-0726-4C02-9C89-FC97EB06D144",
"versionEndExcluding": "200.001.00.p027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when copying the timestamp read from an MQTT message, the underlying code does not check the bounds of the buffer that is used to store the message. This may lead to a stack-based buffer overflow."
},
{
"lang": "es",
"value": "En SunGrow WiNet-SV200.001.00.P027 y versiones anteriores, al copiar la lectura timestamp de un mensaje MQTT, el c\u00f3digo subyacente no comprueba los l\u00edmites del b\u00fafer que se utiliza para almacenar el mensaje. Esto puede provocar un desbordamiento del b\u00fafer basado en la pila."
}
],
"id": "CVE-2024-50694",
"lastModified": "2025-05-29T16:02:20.297",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-24T23:15:09.000",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-50695
Vulnerability from fkie_nvd - Published: 2025-01-24 23:15 - Updated: 2025-05-29 16:02
Severity ?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to stack-based buffer overflow when parsing MQTT messages, due to missing MQTT topic bounds checks.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://en.sungrowpower.com/security-notice-detail-2/5961 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EC5C36C-0726-4C02-9C89-FC97EB06D144",
"versionEndExcluding": "200.001.00.p027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to stack-based buffer overflow when parsing MQTT messages, due to missing MQTT topic bounds checks."
},
{
"lang": "es",
"value": "SunGrow WiNet-SV200.001.00.P027 y versiones anteriores son vulnerables al desbordamiento de b\u00fafer basado en pila al analizar mensajes MQTT, debido a la falta de comprobaciones de los l\u00edmites de temas MQTT."
}
],
"id": "CVE-2024-50695",
"lastModified": "2025-05-29T16:02:13.390",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-24T23:15:09.130",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-50698
Vulnerability from fkie_nvd - Published: 2025-01-24 23:15 - Updated: 2025-05-29 16:01
Severity ?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to heap-based buffer overflow due to bounds checks of the MQTT message content.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://en.sungrowpower.com/security-notice-detail-2/5961 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EC5C36C-0726-4C02-9C89-FC97EB06D144",
"versionEndExcluding": "200.001.00.p027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to heap-based buffer overflow due to bounds checks of the MQTT message content."
},
{
"lang": "es",
"value": "SunGrow WiNet-SV200.001.00.P027 y versiones anteriores son vulnerables al desbordamiento del b\u00fafer basado en el mont\u00f3n debido a las comprobaciones de los l\u00edmites del contenido del mensaje MQTT."
}
],
"id": "CVE-2024-50698",
"lastModified": "2025-05-29T16:01:55.367",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-24T23:15:09.380",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-50690
Vulnerability from fkie_nvd - Published: 2025-01-24 23:15 - Updated: 2025-05-29 16:02
Severity ?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions contains a hardcoded password that can be used to decrypt all firmware updates.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://en.sungrowpower.com/security-notice-detail-2/5961 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EC5C36C-0726-4C02-9C89-FC97EB06D144",
"versionEndExcluding": "200.001.00.p027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions contains a hardcoded password that can be used to decrypt all firmware updates."
},
{
"lang": "es",
"value": "SunGrow WiNet-SV200.001.00.P027 y versiones anteriores contienen una contrase\u00f1a codificada que se puede utilizar para descifrar todas las actualizaciones de firmware."
}
],
"id": "CVE-2024-50690",
"lastModified": "2025-05-29T16:02:33.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 2.5,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-24T23:15:08.227",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-50692
Vulnerability from fkie_nvd - Published: 2025-01-24 23:15 - Updated: 2025-05-29 16:02
Severity ?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions contains hardcoded MQTT credentials that allow an attacker to send arbitrary commands to an arbitrary inverter. It is also possible to impersonate the broker, because TLS is not used to identify the real MQTT broker. This means that MQTT communications are vulnerable to MitM attacks at the TCP/IP level.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sungrowpower | winet-s_firmware | 200.001.00.p027 | |
| sungrowpower | winet-s_firmware | * | |
| sungrowpower | winet-s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:200.001.00.p027:*:*:*:*:*:*:*",
"matchCriteriaId": "63F88B4E-D11C-45DA-B951-A2198E22F316",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7EC5C36C-0726-4C02-9C89-FC97EB06D144",
"versionEndExcluding": "200.001.00.p027",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions contains hardcoded MQTT credentials that allow an attacker to send arbitrary commands to an arbitrary inverter. It is also possible to impersonate the broker, because TLS is not used to identify the real MQTT broker. This means that MQTT communications are vulnerable to MitM attacks at the TCP/IP level."
},
{
"lang": "es",
"value": "SunGrow WiNet-SV200.001.00.P027 y versiones anteriores contienen credenciales MQTT codificadas que permiten a un atacante enviar comandos arbitrarios a un inversor arbitrario. Tambi\u00e9n es posible hacerse pasar por el br\u00f3ker, ya que no se utiliza TLS para identificar al br\u00f3ker MQTT real. Esto significa que las comunicaciones MQTT son vulnerables a ataques MitM a nivel TCP/IP."
}
],
"id": "CVE-2024-50692",
"lastModified": "2025-05-29T16:02:26.353",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-24T23:15:08.893",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"Product"
],
"url": "https://mqtt-pwn.readthedocs.io/en/latest/intro.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
CVE-2024-50696 (GCVE-0-2024-50696)
Vulnerability from cvelistv5 – Published: 2025-02-26 00:00 – Updated: 2025-03-04 21:09
VLAI?
Summary
SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50696",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-28T16:59:23.203751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-04T21:09:49.150Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T20:48:21.220Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/6140"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50696",
"datePublished": "2025-02-26T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-03-04T21:09:49.150Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50690 (GCVE-0-2024-50690)
Vulnerability from cvelistv5 – Published: 2025-01-24 00:00 – Updated: 2025-02-06 21:26
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions contains a hardcoded password that can be used to decrypt all firmware updates.
Severity ?
6.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50690",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T14:38:14.503801Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:26:55.806Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions contains a hardcoded password that can be used to decrypt all firmware updates."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:57:30.177Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50690",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-06T21:26:55.806Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50692 (GCVE-0-2024-50692)
Vulnerability from cvelistv5 – Published: 2025-01-24 00:00 – Updated: 2025-02-06 16:15
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions contains hardcoded MQTT credentials that allow an attacker to send arbitrary commands to an arbitrary inverter. It is also possible to impersonate the broker, because TLS is not used to identify the real MQTT broker. This means that MQTT communications are vulnerable to MitM attacks at the TCP/IP level.
Severity ?
5.4 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50692",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T14:31:47.649209Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T16:15:21.745Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://mqtt-pwn.readthedocs.io/en/latest/intro.html"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions contains hardcoded MQTT credentials that allow an attacker to send arbitrary commands to an arbitrary inverter. It is also possible to impersonate the broker, because TLS is not used to identify the real MQTT broker. This means that MQTT communications are vulnerable to MitM attacks at the TCP/IP level."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:56:35.998Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50692",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-06T16:15:21.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50695 (GCVE-0-2024-50695)
Vulnerability from cvelistv5 – Published: 2025-01-24 00:00 – Updated: 2025-02-05 14:32
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to stack-based buffer overflow when parsing MQTT messages, due to missing MQTT topic bounds checks.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50695",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T16:49:23.610987Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T14:32:09.430Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to stack-based buffer overflow when parsing MQTT messages, due to missing MQTT topic bounds checks."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T23:00:21.742Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50695",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-05T14:32:09.430Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50698 (GCVE-0-2024-50698)
Vulnerability from cvelistv5 – Published: 2025-01-24 00:00 – Updated: 2025-09-15 15:35
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to heap-based buffer overflow due to bounds checks of the MQTT message content.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50698",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T16:49:21.704121Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T15:35:57.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to heap-based buffer overflow due to bounds checks of the MQTT message content."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T23:01:22.613Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50698",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-09-15T15:35:57.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50694 (GCVE-0-2024-50694)
Vulnerability from cvelistv5 – Published: 2025-01-24 00:00 – Updated: 2025-02-05 14:32
VLAI?
Summary
In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when copying the timestamp read from an MQTT message, the underlying code does not check the bounds of the buffer that is used to store the message. This may lead to a stack-based buffer overflow.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T16:49:25.536166Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T14:32:28.508Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when copying the timestamp read from an MQTT message, the underlying code does not check the bounds of the buffer that is used to store the message. This may lead to a stack-based buffer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:58:40.424Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50694",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-05T14:32:28.508Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50697 (GCVE-0-2024-50697)
Vulnerability from cvelistv5 – Published: 2025-01-24 00:00 – Updated: 2025-01-27 15:37
VLAI?
Summary
In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when decrypting MQTT messages, the code that parses specific TLV fields does not have sufficient bounds checks. This may result in a stack-based buffer overflow.
Severity ?
8.1 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50697",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T15:35:15.858352Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-27T15:37:57.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when decrypting MQTT messages, the code that parses specific TLV fields does not have sufficient bounds checks. This may result in a stack-based buffer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:59:36.437Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50697",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-01-27T15:37:57.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50696 (GCVE-0-2024-50696)
Vulnerability from nvd – Published: 2025-02-26 00:00 – Updated: 2025-03-04 21:09
VLAI?
Summary
SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50696",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-28T16:59:23.203751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-04T21:09:49.150Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T20:48:21.220Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/6140"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50696",
"datePublished": "2025-02-26T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-03-04T21:09:49.150Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50690 (GCVE-0-2024-50690)
Vulnerability from nvd – Published: 2025-01-24 00:00 – Updated: 2025-02-06 21:26
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions contains a hardcoded password that can be used to decrypt all firmware updates.
Severity ?
6.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50690",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T14:38:14.503801Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:26:55.806Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions contains a hardcoded password that can be used to decrypt all firmware updates."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:57:30.177Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50690",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-06T21:26:55.806Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50692 (GCVE-0-2024-50692)
Vulnerability from nvd – Published: 2025-01-24 00:00 – Updated: 2025-02-06 16:15
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions contains hardcoded MQTT credentials that allow an attacker to send arbitrary commands to an arbitrary inverter. It is also possible to impersonate the broker, because TLS is not used to identify the real MQTT broker. This means that MQTT communications are vulnerable to MitM attacks at the TCP/IP level.
Severity ?
5.4 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50692",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T14:31:47.649209Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T16:15:21.745Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://mqtt-pwn.readthedocs.io/en/latest/intro.html"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions contains hardcoded MQTT credentials that allow an attacker to send arbitrary commands to an arbitrary inverter. It is also possible to impersonate the broker, because TLS is not used to identify the real MQTT broker. This means that MQTT communications are vulnerable to MitM attacks at the TCP/IP level."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:56:35.998Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50692",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-06T16:15:21.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50695 (GCVE-0-2024-50695)
Vulnerability from nvd – Published: 2025-01-24 00:00 – Updated: 2025-02-05 14:32
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to stack-based buffer overflow when parsing MQTT messages, due to missing MQTT topic bounds checks.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50695",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T16:49:23.610987Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T14:32:09.430Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to stack-based buffer overflow when parsing MQTT messages, due to missing MQTT topic bounds checks."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T23:00:21.742Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50695",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-05T14:32:09.430Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50698 (GCVE-0-2024-50698)
Vulnerability from nvd – Published: 2025-01-24 00:00 – Updated: 2025-09-15 15:35
VLAI?
Summary
SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to heap-based buffer overflow due to bounds checks of the MQTT message content.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50698",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T16:49:21.704121Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T15:35:57.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-SV200.001.00.P027 and earlier versions is vulnerable to heap-based buffer overflow due to bounds checks of the MQTT message content."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T23:01:22.613Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50698",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-09-15T15:35:57.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50694 (GCVE-0-2024-50694)
Vulnerability from nvd – Published: 2025-01-24 00:00 – Updated: 2025-02-05 14:32
VLAI?
Summary
In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when copying the timestamp read from an MQTT message, the underlying code does not check the bounds of the buffer that is used to store the message. This may lead to a stack-based buffer overflow.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T16:49:25.536166Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T14:32:28.508Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when copying the timestamp read from an MQTT message, the underlying code does not check the bounds of the buffer that is used to store the message. This may lead to a stack-based buffer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:58:40.424Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50694",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-02-05T14:32:28.508Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-50697 (GCVE-0-2024-50697)
Vulnerability from nvd – Published: 2025-01-24 00:00 – Updated: 2025-01-27 15:37
VLAI?
Summary
In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when decrypting MQTT messages, the code that parses specific TLV fields does not have sufficient bounds checks. This may result in a stack-based buffer overflow.
Severity ?
8.1 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-50697",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-27T15:35:15.858352Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-27T15:37:57.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In SunGrow WiNet-SV200.001.00.P027 and earlier versions, when decrypting MQTT messages, the code that parses specific TLV fields does not have sufficient bounds checks. This may result in a stack-based buffer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T22:59:36.437Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/5961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-50697",
"datePublished": "2025-01-24T00:00:00.000Z",
"dateReserved": "2024-10-28T00:00:00.000Z",
"dateUpdated": "2025-01-27T15:37:57.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}