Search criteria
3 vulnerabilities found for wnce3001 by netgear
CVE-2025-6565 (GCVE-0-2025-6565)
Vulnerability from cvelistv5 – Published: 2025-06-24 13:00 – Updated: 2025-06-25 12:41
VLAI?
Summary
A vulnerability was found in Netgear WNCE3001 1.0.0.50. It has been classified as critical. This affects the function http_d of the component HTTP POST Request Handler. The manipulation of the argument Host leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Credits
xiaobor123 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6565",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:36:46.136796Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:41:43.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "WNCE3001",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.0.50"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "xiaobor123 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNCE3001 1.0.0.50. It has been classified as critical. This affects the function http_d of the component HTTP POST Request Handler. The manipulation of the argument Host leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Netgear WNCE3001 1.0.0.50 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion http_d der Komponente HTTP POST Request Handler. Mittels Manipulieren des Arguments Host mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:00:12.914Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-313737 | Netgear WNCE3001 HTTP POST Request http_d stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.313737"
},
{
"name": "VDB-313737 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.313737"
},
{
"name": "Submit #590030 | Netgear WNCE3001 1.0.0.50 Stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.590030"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-wnce3001-netgear"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-wnce3001-netgear#poc"
},
{
"tags": [
"product"
],
"url": "https://www.netgear.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-24T10:04:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNCE3001 HTTP POST Request http_d stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6565",
"datePublished": "2025-06-24T13:00:12.914Z",
"dateReserved": "2025-06-24T07:59:36.976Z",
"dateUpdated": "2025-06-25T12:41:43.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6565 (GCVE-0-2025-6565)
Vulnerability from nvd – Published: 2025-06-24 13:00 – Updated: 2025-06-25 12:41
VLAI?
Summary
A vulnerability was found in Netgear WNCE3001 1.0.0.50. It has been classified as critical. This affects the function http_d of the component HTTP POST Request Handler. The manipulation of the argument Host leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Credits
xiaobor123 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6565",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-24T15:36:46.136796Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T12:41:43.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "WNCE3001",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.0.50"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "xiaobor123 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNCE3001 1.0.0.50. It has been classified as critical. This affects the function http_d of the component HTTP POST Request Handler. The manipulation of the argument Host leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Netgear WNCE3001 1.0.0.50 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion http_d der Komponente HTTP POST Request Handler. Mittels Manipulieren des Arguments Host mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-24T13:00:12.914Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-313737 | Netgear WNCE3001 HTTP POST Request http_d stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.313737"
},
{
"name": "VDB-313737 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.313737"
},
{
"name": "Submit #590030 | Netgear WNCE3001 1.0.0.50 Stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.590030"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-wnce3001-netgear"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-wnce3001-netgear#poc"
},
{
"tags": [
"product"
],
"url": "https://www.netgear.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-24T10:04:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNCE3001 HTTP POST Request http_d stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6565",
"datePublished": "2025-06-24T13:00:12.914Z",
"dateReserved": "2025-06-24T07:59:36.976Z",
"dateUpdated": "2025-06-25T12:41:43.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-202203-0653
Vulnerability from variot - Updated: 2023-12-18 13:37A vulnerability is in the 'MNU_top.htm' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device. of netgear mbr1517 firmware, wnce3001 firmware, WAC104 Firmware has a lack of authentication vulnerability for critical functionality.Information may be obtained. Netgear W104 is a wireless access point from Netgear Corporation of the United States
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202203-0653",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mbr1517",
"scope": "eq",
"trust": 1.0,
"vendor": "netgear",
"version": "*"
},
{
"model": "wac104",
"scope": "lte",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.13"
},
{
"model": "wnce3001",
"scope": "eq",
"trust": 1.0,
"vendor": "netgear",
"version": "*"
},
{
"model": "wac104",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wnce3001",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "mbr1517",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wac104",
"scope": "lte",
"trust": 0.6,
"vendor": "netgear",
"version": "\u003c=1.0.4.13"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22306"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "NVD",
"id": "CVE-2021-44262"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:mbr1517_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:mbr1517:v2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wnce3001_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wnce3001:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wac104_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.0.4.13",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wac104:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-44262"
}
]
},
"cve": "CVE-2021-44262",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-44262",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-22306",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-44262",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-44262",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-22306",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202203-1571",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22306"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability is in the \u0027MNU_top.htm\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device. of netgear mbr1517 firmware, wnce3001 firmware, WAC104 Firmware has a lack of authentication vulnerability for critical functionality.Information may be obtained. Netgear W104 is a wireless access point from Netgear Corporation of the United States",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "CNVD",
"id": "CNVD-2022-22306"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-44262",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-018882",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-22306",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1571",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22306"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
]
},
"id": "VAR-202203-0653",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22306"
}
],
"trust": 1.21673352
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22306"
}
]
},
"last_update_date": "2023-12-18T13:37:02.226000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.0
},
{
"problemtype": "Lack of authentication for critical features (CWE-306) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "NVD",
"id": "CVE-2021-44262"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/zer0yu/cve_request/blob/master/netgear/netgear_w104_unauthorized_access_vulnerability_second.md"
},
{
"trust": 2.4,
"url": "https://www.netgear.com/about/security/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-44262"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2021-44262/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-22306"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-22306"
},
{
"date": "2023-07-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"date": "2022-03-17T13:15:07.593000",
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"date": "2022-03-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-22306"
},
{
"date": "2023-07-10T08:22:00",
"db": "JVNDB",
"id": "JVNDB-2021-018882"
},
{
"date": "2022-03-23T18:52:02.227000",
"db": "NVD",
"id": "CVE-2021-44262"
},
{
"date": "2022-03-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerability related to lack of authentication for important functions in multiple NETGEAR products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-018882"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-1571"
}
],
"trust": 0.6
}
}