Search criteria
339 vulnerabilities found for wndr3700_firmware by netgear
FKIE_CVE-2023-0849
Vulnerability from fkie_nvd - Published: 2023-02-15 22:15 - Updated: 2024-11-21 07:37
Severity ?
4.7 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://vuldb.com/?ctiid.221152 | Permissions Required, Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.221152 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.221152 | Permissions Required, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.221152 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wndr3700_firmware | 1.0.1.14 | |
| netgear | wndr3700 | v2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:1.0.1.14:*:*:*:*:*:*:*",
"matchCriteriaId": "C070DBCF-B268-4CD5-B914-BBD115E219A9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "7C0FE2FB-A508-4429-86F4-FFE93C1DA055",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152."
}
],
"id": "CVE-2023-0849",
"lastModified": "2024-11-21T07:37:57.207",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.4,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.4,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-02-15T22:15:12.233",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.221152"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.221152"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.221152"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.221152"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "cna@vuldb.com",
"type": "Primary"
}
]
}
FKIE_CVE-2023-0850
Vulnerability from fkie_nvd - Published: 2023-02-15 22:15 - Updated: 2024-11-21 07:37
Severity ?
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://vuldb.com/?ctiid.221153 | Permissions Required, Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.221153 | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.221153 | Permissions Required, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.221153 | Exploit, Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wndr3700_firmware | 1.0.1.14 | |
| netgear | wndr3700 | v2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:1.0.1.14:*:*:*:*:*:*:*",
"matchCriteriaId": "C070DBCF-B268-4CD5-B914-BBD115E219A9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "7C0FE2FB-A508-4429-86F4-FFE93C1DA055",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability."
}
],
"id": "CVE-2023-0850",
"lastModified": "2024-11-21T07:37:57.340",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:M/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.4,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 1.4,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-02-15T22:15:12.323",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.221153"
},
{
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.221153"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.221153"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.221153"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-404"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-0848
Vulnerability from fkie_nvd - Published: 2023-02-15 22:15 - Updated: 2024-11-21 07:37
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability was found in Netgear WNDR3700v2 1.0.1.14. It has been rated as problematic. This issue affects some unknown processing of the component Web Management Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221147.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://vuldb.com/?ctiid.221147 | Permissions Required, Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.221147 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.221147 | Permissions Required, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.221147 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wndr3700_firmware | 1.0.1.14 | |
| netgear | wndr3700 | v2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:1.0.1.14:*:*:*:*:*:*:*",
"matchCriteriaId": "C070DBCF-B268-4CD5-B914-BBD115E219A9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "7C0FE2FB-A508-4429-86F4-FFE93C1DA055",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14. It has been rated as problematic. This issue affects some unknown processing of the component Web Management Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221147."
}
],
"id": "CVE-2023-0848",
"lastModified": "2024-11-21T07:37:57.063",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-02-15T22:15:12.127",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.221147"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.221147"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.221147"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.221147"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-404"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-38514
Vulnerability from fkie_nvd - Published: 2021-08-11 00:15 - Updated: 2024-11-21 06:17
Severity ?
2.4 (Low) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6C8A5E09-861A-4C5F-8C0A-96803782E9EF",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33C16A69-C930-4DA3-8750-EB50F2827731",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A",
"versionEndExcluding": "1.0.0.63",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FCEBCD7-1D0D-47F6-BC72-A53BFBF3662D",
"versionEndExcluding": "1.1.00.34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F36AC74-11DB-4805-9B73-302F86A8C240",
"versionEndExcluding": "1.0.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "58E68C65-9685-40E8-8D51-6C922232168B",
"versionEndExcluding": "1.0.0.86",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AD73CBDF-0B17-4B1A-8A06-9F3926D1D113",
"versionEndExcluding": "1.0.1.70",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0A0D49BA-4843-4F7E-984A-FF7BDF292F56",
"versionEndExcluding": "1.0.0.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5",
"versionEndExcluding": "1.0.1.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C329B7CB-1281-480D-BDDB-E222044D715E",
"versionEndExcluding": "1.0.3.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDF9C0E1-7128-4052-B05E-3DD3394208A0",
"versionEndExcluding": "1.0.0.42",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "373DD028-D307-4B4A-9C35-DDC9366F481F",
"versionEndExcluding": "1.0.0.108",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgnd2200b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "411A0637-1498-4376-B10D-004D096EC4F6",
"versionEndExcluding": "1.0.0.108",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgnd2200b:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "D6EBFFCE-0D9E-4383-8CD6-3DC4D2412446",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100",
"versionEndExcluding": "1.0.1.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0864CF6F-C025-44FE-B00F-83E14ACE1F8F",
"versionEndExcluding": "1.0.0.76",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B760484C-0D85-49BF-AA5D-2DB0A3A5D7E6",
"versionEndExcluding": "1.0.0.76",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E8357471-53D2-4FCF-85CD-7D4297960841",
"versionEndExcluding": "1.0.0.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "02E7CA7E-E6CA-4BAB-8F40-4731EA523D91",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "094113E0-3656-4E2A-B9EF-D397296BD07C",
"versionEndExcluding": "1.0.2.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AB84CD03-765C-4D4F-A176-364F8E72A4E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963",
"versionEndExcluding": "1.0.1.76",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23EA7CC1-B1E8-431F-B4AF-8393B85F26E3",
"versionEndExcluding": "1.0.0.42",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18C88DDC-92C2-400E-8269-88A0EA65A98A",
"versionEndExcluding": "1.0.0.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D74896A7-7EF2-41C9-8A29-59B2EA5ABA5C",
"versionEndExcluding": "1.0.0.42",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6150:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "2CB9BD19-E748-41B9-8873-316FEB83F13D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC",
"versionEndExcluding": "1.0.1.76",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A81A7574-A2C7-4216-98C6-6790FA705013",
"versionEndExcluding": "1.0.3.88",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49",
"versionEndExcluding": "1.0.1.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F",
"versionEndExcluding": "1.0.2.136",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2F1E93FB-4926-4AF5-BA5F-A4DE4314B45F",
"versionEndExcluding": "1.0.0.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0",
"versionEndExcluding": "1.0.2.136",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048",
"versionEndExcluding": "1.0.1.180",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EFF5F80A-5196-4585-9993-6D985561B75E",
"versionEndExcluding": "2.1.4.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A59BA256-2D2F-4930-9033-D312BA01D1FB",
"versionEndExcluding": "2.1.4.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD22FA4E-1D05-4A83-9610-731957A96A96",
"versionEndExcluding": "2.1.4.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14BE7862-3CBB-472E-9339-1435999C57F9",
"versionEndExcluding": "2.1.4.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2FCEC68E-0BD3-47E6-AD24-EE9076654B86",
"versionEndExcluding": "2.1.4.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "00C4765D-D903-4967-91D2-11F59458EBCD",
"versionEndExcluding": "2.1.4.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CE0E9E59-4F1F-490B-BCE8-B3690593353B",
"versionEndExcluding": "2.2.1.204",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "50E2E26A-200E-4D00-9657-034EACE3944F",
"versionEndExcluding": "1.0.0.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27FC1738-5A2C-4D4B-944C-1EB1A8D2476E",
"versionEndExcluding": "1.0.0.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "442B71BC-D2D4-4F0F-8962-B50D5E8D2833",
"versionEndExcluding": "1.0.0.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EDB0CD0A-A68D-4EF5-A938-6A15604C9107",
"versionEndExcluding": "1.0.1.18",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*",
"matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC9C60BB-2E7F-4D35-9348-8D8AEFAAD75F",
"versionEndExcluding": "1.0.1.18",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "92F53D21-C688-4477-815D-EFFF08F7D085",
"versionEndExcluding": "1.0.0.46",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51FC4898-BF35-443A-A003-40351B20ADEC",
"versionEndExcluding": "1.1.0.86",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1DD1F7D-7556-4B95-A33F-E389948D20AA",
"versionEndExcluding": "1.0.4.34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E997B769-B2F7-4BB5-A834-96A68EF842BA",
"versionEndExcluding": "1.0.4.32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF638167-B018-4140-B115-C65F387EFD77",
"versionEndExcluding": "1.0.1.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "91532716-831D-401C-8707-86785F0A4E16",
"versionEndExcluding": "1.0.2.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "732F20CF-135F-4CBF-988F-215B534994B1",
"versionEndExcluding": "1.0.1.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4A4FB8A1-D380-4234-88EB-91BFF6D215C7",
"versionEndExcluding": "1.2.0.36",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3C39CE79-6433-47E2-A439-9AB1DFBD843C",
"versionEndExcluding": "1.2.0.36",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DB6992BA-B0F5-4E00-84F4-0B0336910AFA",
"versionEndExcluding": "1.2.0.36",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7BAAD2F7-BF0A-412B-BC2E-A69DC9BCB52E",
"versionEndExcluding": "1.0.1.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E453D3AE-A218-4791-BB19-79C2CF6EC6F8",
"versionEndExcluding": "1.0.9.34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "103B19E9-C72D-43C2-8369-1C425E9B9AC7",
"versionEndExcluding": "1.3.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E23D8A41-75D8-4067-A961-3B81276527A8",
"versionEndExcluding": "1.3.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B484FA9-17B9-4829-9152-83691EE6A9BB",
"versionEndExcluding": "1.0.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F168C3F8-F77C-4918-A752-9A04CED2349E",
"versionEndExcluding": "1.0.0.70",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C",
"versionEndExcluding": "1.0.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845CF217-8361-4D5B-811D-B9CEB68880CB",
"versionEndExcluding": "1.0.3.8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "98FAEBDA-5FBA-402D-9BA1-25E5DF4EF55F",
"versionEndExcluding": "1.0.4.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8BBB7E16-D31C-49EA-9D82-D3BACED95441",
"versionEndExcluding": "1.4.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6791754E-E5F9-42EA-AFDA-F93E8227A7C8",
"versionEndExcluding": "1.4.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FD0AB065-3152-492B-A66D-2BCCA1E3B1DA",
"versionEndExcluding": "1.0.2.128",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "28EC6190-68BC-4D9A-9973-01935EB3472F",
"versionEndExcluding": "1.0.2.128",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12",
"versionEndExcluding": "1.0.3.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6160F657-601E-4BDD-949A-D1411F08A8F9",
"versionEndExcluding": "2.2.0.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk50v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF38D418-BF9B-4C69-8D05-6D216B487182",
"versionEndExcluding": "2.2.0.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk50v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "54453B5D-4E51-4DAB-8670-5A99C0D4CE3E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E",
"versionEndExcluding": "1.0.1.32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0675F6C4-EB61-4DA3-8473-448E93D5E0A5",
"versionEndExcluding": "1.0.1.54",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "1C4C1B98-9551-4862-AEAC-3D5C313BD275",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "250E8C27-ED0F-46FC-B630-52E9BF2CA812",
"versionEndExcluding": "1.0.2.78",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A480981E-57ED-47E3-B9AB-190E4783DC04",
"versionEndExcluding": "1.0.0.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "46D1F73B-1AE0-40AE-BED7-CAE3C7EFEE3B",
"versionEndExcluding": "1.0.1.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39",
"versionEndExcluding": "1.0.2.102",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C",
"versionEndExcluding": "1.0.2.104",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88",
"versionEndExcluding": "1.0.0.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED",
"versionEndExcluding": "1.0.0.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F3D02E3-8FA1-4129-A4B2-25235AF0E49C",
"versionEndExcluding": "1.0.0.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E0141851-BE96-4F6A-883F-3B20AE6945C1",
"versionEndExcluding": "1.1.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "727F8FD9-692C-4752-9B1E-D6281919061C",
"versionEndExcluding": "1.1.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1748207-4BAA-4CC2-AD44-19D895B1C08B",
"versionEndExcluding": "1.2.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C031037-5177-4871-9C61-15BC580CC41D",
"versionEndExcluding": "2.3.2.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de la autenticaci\u00f3n. Esto afecta a D3600 versiones anteriores a 1.0.0.72, D6000 versiones anteriores a 1.0.0.72, D6100 versiones anteriores a 1.0.0.63, D6200 versiones anteriores a 1.1.00.34, D6220 versiones anteriores a 1.0.0.48, D6400 versiones anteriores a 1.0.0.86, D7000 versiones anteriores a 1.0.1.70, D7000v2 versiones anteriores a 1.0.0.52, D7800 versiones anteriores a 1.0.1.56, D8500 versiones anteriores a 1.0.3.44, DC112A versiones anteriores a 1.0.0.42, DGN8000 versiones anteriores a 1.0.4.98. 0.0.42, DGN2200v4 versiones anteriores a 1.0.0.108, DGND2200Bv4 versiones anteriores a 1.0.0.108, EX2700 versiones anteriores a 1.0.1.48, EX3700 versiones anteriores a 1.0.0.76, EX3800 versiones anteriores a 1.0.0.76, EX6000 versiones anteriores a 1.0.0.38, EX6100 versiones anteriores a 1.0.2.24, EX6100v2 versiones anteriores a 1.0.1.76, EX6120 versiones anteriores a 1.0.0.42, EX6130 versiones anteriores a 1. 0.0.28, EX6150v1 versiones anteriores a 1.0.0.42, EX6150v2 versiones anteriores a 1.0.1.76, EX6200 versiones anteriores a 1.0.3.88, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7000 versiones anteriores a 1.0.0.66, EX7300 versiones anteriores a 1.0.2.136, EX8000 versiones anteriores a 1.0.1.180, RBK50 versiones anteriores a 2.1.4.10, RBR50 versiones anteriores a 2.1.4. 10, RBS50 versiones anteriores a 2.1.4.10, RBK40 versiones anteriores a 2.1.4.10, RBR40 versiones anteriores a 2.1.4.10, RBS40 versiones anteriores a 2.1.4.10, RBW30 versiones anteriores a 2.2.1.204, PR2000 versiones anteriores a 1.0.0.28, R6020 versiones anteriores a 1.0.0.38, R6080 versiones anteriores a 1.0.0.38, R6050 versiones anteriores a 1.0.1.18, JR6150 versiones anteriores a 1.0.1.18, R6120 versiones anteriores a 1.0. 0.46, R6220 versiones anteriores a 1.1.0.86, R6250 versiones anteriores a 1.0.4.34, R6300v2 versiones anteriores a 1.0.4.32, R6400 versiones anteriores a 1.0.1.44, R6400v2 versiones anteriores a 1.0.2. 62, R6700 versiones anteriores a 1.0.1.48, R6700v2 versiones anteriores a 1.2.0.36, R6800 versiones anteriores a 1.2.0.36, R6900v2 versiones anteriores a 1.2.0.36, R6900 versiones anteriores a 1.0.1.48, R7000 versiones anteriores a 1. 0.9.34, R6900P versiones anteriores a 1.3.1.64, R7000P versiones anteriores a 1.3.1.64, R7100LG versiones anteriores a 1.0.0.48, R7300DST versiones anteriores a 1.0.0.70, R7500v2 versiones anteriores a 1. 0.3.38, R7800 versiones anteriores a 1.0.2.52, R7900 versiones anteriores a 1.0.3.8, R8000 versiones anteriores a 1.0.4.28, R7900P versiones anteriores a 1.4.1.30, R8000P versiones anteriores a 1.4.1. 30, R8300 versiones anteriores a 1.0.2.128, R8500 versiones anteriores a 1.0.2.128, R9000 versiones anteriores a 1.0.3.10, RBS40V versiones anteriores a 2.2.0.58, RBK50V versiones anteriores a 2.2.0. 58, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN2500RPv2 versiones anteriores a 1.0.1.54, WN3000RPv3 versiones anteriores a 1.0.2.78, WN3100RPv2 versiones anteriores a 1.0.0.66, WNDR3400v3 versiones anteriores a 1.0. 1.22, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56, WNDR4500v3 versiones anteriores a 1.0.0. 56, WNR2000v5 (R2000) versiones anteriores a 1.0.0.66, WNR2020 versiones anteriores a 1.1.0.62, WNR2050 versiones anteriores a 1.1.0.62, WNR3500Lv2 versiones anteriores a 1.2.0.62 y XR500 versiones anteriores a 2.3.2.22"
}
],
"id": "CVE-2021-38514",
"lastModified": "2024-11-21T06:17:17.693",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 1.4,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-11T00:15:15.663",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21224
Vulnerability from fkie_nvd - Published: 2020-04-28 17:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | d3600_firmware | * | |
| netgear | d3600 | - | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | wnr2000_firmware | * | |
| netgear | wnr2000 | v5 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02",
"versionEndExcluding": "1.0.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62."
}
],
"id": "CVE-2018-21224",
"lastModified": "2024-11-21T04:03:13.280",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T17:15:13.103",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21222
Vulnerability from fkie_nvd - Published: 2020-04-28 17:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wnr2000_firmware | * | |
| netgear | wnr2000 | v5 | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d3600_firmware | * | |
| netgear | d3600 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02",
"versionEndExcluding": "1.0.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62."
}
],
"id": "CVE-2018-21222",
"lastModified": "2024-11-21T04:03:12.950",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T17:15:12.930",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2016-11057
Vulnerability from fkie_nvd - Published: 2020-04-28 17:15 - Updated: 2024-11-21 02:45
Severity ?
Summary
Certain NETGEAR devices are affected by mishandling of repeated URL calls. This affects JNR1010v2 before 2017-01-06, WNR614 before 2017-01-06, WNR618 before 2017-01-06, JWNR2000v5 before 2017-01-06, WNR2020 before 2017-01-06, JWNR2010v5 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2020v2 before 2017-01-06, R6220 before 2017-01-06, and WNDR3700v5 before 2017-01-06.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | jnr1010_firmware | * | |
| netgear | jnr1010 | v2 | |
| netgear | jwnr2000_firmware | * | |
| netgear | jwnr2000 | v5 | |
| netgear | jwnr2010_firmware | * | |
| netgear | jwnr2010 | v5 | |
| netgear | r6220_firmware | * | |
| netgear | r6220 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v5 | |
| netgear | wnr1000_firmware | * | |
| netgear | wnr1000 | v4 | |
| netgear | wnr2020_firmware | * | |
| netgear | wnr2020 | - | |
| netgear | wnr2020_firmware | * | |
| netgear | wnr2020 | v2 | |
| netgear | wnr614_firmware | * | |
| netgear | wnr614 | - | |
| netgear | wnr618_firmware | * | |
| netgear | wnr618 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F19C07A-65D3-4FFF-9D11-58C2B4D7A531",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jwnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "86B79A3A-8A63-4BD5-9016-8C98AEF737A8",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jwnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "3D78543E-37A7-4829-9165-D0CF52DD4867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3B1059F8-32A9-4E9A-BBFF-548CFDCF676A",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "717CDDCB-3DEB-4949-AAC8-D939D01A0858",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "894CEEC8-F75E-45EB-B1C8-87BB465980BA",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "894CEEC8-F75E-45EB-B1C8-87BB465980BA",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2020:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "3EA06558-20FF-4E1D-BA34-9645421F8CC1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr614_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D327648B-8616-4965-9471-243501A8E4E9",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr614:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EC8A668E-4A30-4364-AF7A-F3C814BBAACA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr618_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FB949B1-75B6-4262-919F-119B2D8ABF8C",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr618:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7BAA7BF1-2DFE-4ADA-B3A7-F33EEAAC5962",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by mishandling of repeated URL calls. This affects JNR1010v2 before 2017-01-06, WNR614 before 2017-01-06, WNR618 before 2017-01-06, JWNR2000v5 before 2017-01-06, WNR2020 before 2017-01-06, JWNR2010v5 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2020v2 before 2017-01-06, R6220 before 2017-01-06, and WNDR3700v5 before 2017-01-06."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por el manejo inapropiado de llamadas URL repetidas. Esto afecta a JNR1010v2 hasta el 06-01-2017 WNR614 hasta el 06-01-2017, WNR618 hasta el 06-01-2017, JWNR2000v5 hasta el 06-01-2017, WNR2020 hasta el 06-01-2017, JWNR2010v5 hasta el 06-01-2017, WNR1000v4 hasta el 06-01-2017, WNR2020v2 hasta el 06-01-2017, R6220 hasta el 06-01-2017, y WNDR3700v5 hasta el 06-01-2017."
}
],
"id": "CVE-2016-11057",
"lastModified": "2024-11-21T02:45:23.920",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T17:15:12.353",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/29960/NETGEAR-Product-Vulnerability-Advisory-Potential-security-issue-associated-with-remote-management"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/29960/NETGEAR-Product-Vulnerability-Advisory-Potential-security-issue-associated-with-remote-management"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21223
Vulnerability from fkie_nvd - Published: 2020-04-28 17:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | d3600_firmware | * | |
| netgear | d3600 | - | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | wnr2000_firmware | * | |
| netgear | wnr2000 | v5 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02",
"versionEndExcluding": "1.0.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62."
}
],
"id": "CVE-2018-21223",
"lastModified": "2024-11-21T04:03:13.120",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T17:15:12.993",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2016-11059
Vulnerability from fkie_nvd - Published: 2020-04-28 17:15 - Updated: 2024-11-21 02:45
Severity ?
Summary
Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ac1450_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "32794415-73D5-4C63-BCAB-FA324BBCE850",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ac1450:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4BA18B2-8234-4C26-B865-741D467C5EBE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:c6300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4DC0FCBB-5F1B-417C-8E4B-FBD403CF2E38",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:c6300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7185DE0B-B15C-417D-9AF5-FBF15F9C2241",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d1500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56141687-D086-4EEE-9F8A-C238CC26854E",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d1500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "78DC8809-C26D-48D8-9E12-228C3669B824",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B175146A-AA48-4A89-9712-E87BBB0B389F",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DD7FA616-CD66-488A-92ED-3F28954F9E45",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CE070E3-C0B1-455F-83A9-5C60C489816F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D53F8CC0-F707-4F98-85CE-9A816BE39809",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D349BA3-DF82-4DD5-BDA6-6AB5F3B70BD3",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F22E4FA5-DB96-4946-86B1-0D18A3BEBB2A",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6200b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DFEBB6A6-EABA-4A04-8B49-3C9F64D7C5C6",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6200b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "60FAC76D-96D6-41FB-8EE8-C25F3CBB3307",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2EC71979-23F7-4623-BE4A-82713E95DACD",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "78542C95-85CC-43E5-9F0E-B12DDD5B79C4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6300b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "357F14D2-06B8-4BA5-9D7E-B334F59C7250",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6300b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "37B89703-CAFB-43F6-8880-90349F8ED856",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BEFBB234-2155-45F8-933D-93E89EC1F54F",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn1000:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "430497AE-7C43-400E-9C70-001B2DA23B67",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "769065AA-BC73-4674-87B0-3D514FEFDBEF",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn2200:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "F50D834B-D7B3-43D6-8072-8992FBC8C97B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "769065AA-BC73-4674-87B0-3D514FEFDBEF",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn2200:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "509F9F22-24E7-45E9-AB96-17F8B50813F5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "769065AA-BC73-4674-87B0-3D514FEFDBEF",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5158CF4D-80FC-44FD-B9DA-442FA3A1A913",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn2200b:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "8A4EE9AB-F3DE-4EA8-8344-7F62288EC921",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5158CF4D-80FC-44FD-B9DA-442FA3A1A913",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgnd3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "696689E8-E4C4-4A92-9D00-4C6B8CA80448",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgnd3700:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "8A5971C6-2F27-4715-BC9E-378B647611D8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgnd3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "696689E8-E4C4-4A92-9D00-4C6B8CA80448",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgnd3700:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "7A8F0B8E-D3F2-43C9-8B12-43DE4226E826",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dgnd3700b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E607B102-4151-4829-B5D5-779D096D620F",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dgnd3700b:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "C6F2634F-EA5A-48CE-91BA-964C0B40AF8E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F19C07A-65D3-4FFF-9D11-58C2B4D7A531",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jnr1010:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "B4196FE8-4491-442C-96A0-23495165D3B9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F19C07A-65D3-4FFF-9D11-58C2B4D7A531",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jnr3300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D5738544-7D8A-45AD-99F3-6F92C6886ACD",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jnr3300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "64CA12CC-48D8-4510-983C-8350A87CD5D2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jr6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "30751D8C-301D-4C9F-8512-E887512CE388",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jr6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2C1C81B4-033E-4F44-9D17-27B04FCF8EF4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0AF8ACF6-2BDF-49C2-B92F-2207D83664BF",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jwnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "86B79A3A-8A63-4BD5-9016-8C98AEF737A8",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jwnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "3D78543E-37A7-4829-9165-D0CF52DD4867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D0BCC15-918E-4A31-A943-C5B72CB117E9",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B1D13C3-5663-447F-9FD9-71EBEC471DAF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "675EBB75-3DB8-45D7-9512-5D297C680750",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*",
"matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "067085C6-EA5C-430B-B81E-A5809BD047B0",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ECBBDBEC-C896-4130-933B-150DB17662A3",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8A466B29-3ADA-46D9-824C-8DF9160B7DD7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ECBBDBEC-C896-4130-933B-150DB17662A3",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6200:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "719248B0-BE22-4836-A23E-FE9F7590FB0C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "717CDDCB-3DEB-4949-AAC8-D939D01A0858",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "760BD171-837C-4D36-A4AF-551E926B53C0",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AC7F9A44-CC92-4E00-A274-ADA08469F33F",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9597966A-B13C-4098-838B-EC9AA8DE443D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AC7F9A44-CC92-4E00-A274-ADA08469F33F",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "66DBD436-0DA8-4917-99EB-6A5D0C3D42D1",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D2356B7-389D-4612-8DBE-00C6AC35BD3D",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9866D7B9-622A-4B25-8CFA-D31AB4406A4F",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2BC36898-99C5-4755-9C42-687EAC07013B",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1BBF5B80-58EB-467E-8E07-6CB6C2E88BBC",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wgr614_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A746A6A7-AFD5-41DC-B805-C1526CFD2E95",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wgr614:v10:*:*:*:*:*:*:*",
"matchCriteriaId": "B47B0897-A9B9-4568-84DD-C3CE0118B439",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B2BF93E7-2E14-48C7-BD1A-9C5FC3451334",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3400:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "25187765-6842-4F6A-BF5E-B2E634A958A0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B2BF93E7-2E14-48C7-BD1A-9C5FC3451334",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "A239B4C0-0CD9-4632-A1E3-68B8E39692B3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "58CC514B-1570-4116-9E1F-289BD9DD5935",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "58CC514B-1570-4116-9E1F-289BD9DD5935",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A3BC4526-3FCE-42D3-B34A-C32060B78AF7",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "829C71CF-A1E7-456E-8230-8929BD7E867C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A3BC4526-3FCE-42D3-B34A-C32060B78AF7",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A3BC4526-3FCE-42D3-B34A-C32060B78AF7",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr1000:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "938F4D22-AEFC-4141-BC1C-101F835D4E77",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr1000:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "91D091D4-04EA-4564-A2CC-88E217A9FC08",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCA254A9-B22D-44C5-9261-19AFBD2B2EE4",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C547734B-BF1A-4CD9-8FD8-9ECB3D15B0BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCA254A9-B22D-44C5-9261-19AFBD2B2EE4",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "D2913468-C442-48A3-8AD9-A2F3CCDD7952",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCA254A9-B22D-44C5-9261-19AFBD2B2EE4",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFCD5179-4D17-4187-BFFD-7FF080804D95",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "94B74E4A-3E2F-4CB1-B33D-8618ED1C7E9F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF1CD0F5-D109-460F-9417-1907A6368A8B",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EA9EF618-6194-4127-BD60-FB0E645C8993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DDBCEE9B-9189-42DA-86D1-3FF6E4168127",
"versionEndExcluding": "2017-01-06",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por una exposici\u00f3n de contrase\u00f1as. Esto afecta a AC1450 hasta el 06-01-2017, C6300 hasta el 06-01-2017, D500 hasta el 06-01-2017, D1500 hasta el 06-01-2017, D3600 hasta el 06-01-2017, D6000 hasta el 06-01-2017, D6100 hasta el 06-01-2017, D6200 hasta el 06-01-2017, D6200B hasta el 06-01-2017, D6300B hasta el 06-01-2017, D6300 hasta el 06-01-2017, DGN1000v3 hasta el 06-01-2017, DGN2200v1 hasta el 06-01-2017, DGN2200v3 hasta el 06-01-2017, DGN2200V4 hasta el 06-01-2017, DGN2200Bv3 hasta el 06-01-2017, DGN2200Bv4 hasta el 06-01-2017, DGND3700v1 hasta el 06-01-2017, DGND3700v2 hasta el 06-01-2017, DGND3700Bv2 hasta el 06-01-2017, JNR1010v1 hasta el 06-01-2017, JNR1010v2 hasta el 06-01-2017, JNR3300 hasta el 06-01-2017, JR6100 hasta el 06-01-2017, JR6150 hasta el 06-01-2017, JWNR2000v5 hasta el 06-01-2017, R2000 hasta el 06-01-2017, R6050 hasta el 06-01-2017, R6100 hasta el 06-01-2017, R6200 hasta el 06-01-2017, R6200v2 hasta el 06-01-2017, R6220 hasta el 06-01-2017, R6250 hasta el 06-01-2017, R6300 hasta el 06-01-2017, R6300v2 hasta el 06-01-2017, R6700 hasta el 06-01-2017, R7000 hasta el 06-01-2017, R7900 hasta el 06-01-2017, R7500 hasta el 06-01-2017, R8000 hasta el 06-01-2017, WGR614v10 hasta el 06-01-2017, WNR1000v2 hasta el 06-01-2017, WNR1000v3 hasta el 06-01-2017, WNR1000v4 hasta el 06-01-2017, WNR2000v3 hasta el 06-01-2017, WNR2000v4 hasta el 06-01-2017, WNR2000v5 hasta el 06-01-2017, WNR2200 hasta el 06-01-2017, WNR2500 hasta el 06-01-2017, WNR3500Lv2 hasta el 06-01-2017, WNDR3400v2 hasta el 06-01-2017, WNDR3400v3 hasta el 06-01-2017, WNDR3700v3 hasta el 06-01-2017, WNDR3700v4 hasta el 06-01-2017, WNDR3700v5 hasta el 06-01-2017, WNDR4300 hasta el 06-01-2017, WNDR4300v2 hasta el 06-01-2017, WNDR4500v1 hasta el 06-01-2017, WNDR4500v2 hasta el 06-01-2017, and WNDR4500v3 hasta el 06-01-2017."
}
],
"id": "CVE-2016-11059",
"lastModified": "2024-11-21T02:45:24.220",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T17:15:12.460",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21220
Vulnerability from fkie_nvd - Published: 2020-04-28 16:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wnr2000_firmware | * | |
| netgear | wnr2000 | v5 | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d3600_firmware | * | |
| netgear | d3600 | - | |
| netgear | d6100_firmware | * | |
| netgear | d6100 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02",
"versionEndExcluding": "1.0.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43",
"versionEndExcluding": "1.0.0.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62."
}
],
"id": "CVE-2018-21220",
"lastModified": "2024-11-21T04:03:12.643",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T16:15:14.403",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21218
Vulnerability from fkie_nvd - Published: 2020-04-28 16:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wnr2000_firmware | * | |
| netgear | wnr2000 | v5 | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d3600_firmware | * | |
| netgear | d3600 | - | |
| netgear | d6100_firmware | * | |
| netgear | d6100 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02",
"versionEndExcluding": "1.0.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43",
"versionEndExcluding": "1.0.0.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62."
}
],
"id": "CVE-2018-21218",
"lastModified": "2024-11-21T04:03:12.327",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T16:15:14.310",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21219
Vulnerability from fkie_nvd - Published: 2020-04-28 16:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wnr2000_firmware | * | |
| netgear | wnr2000 | v5 | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d3600_firmware | * | |
| netgear | d3600 | - | |
| netgear | d6100_firmware | * | |
| netgear | d6100 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02",
"versionEndExcluding": "1.0.0.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43",
"versionEndExcluding": "1.0.0.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62."
}
],
"id": "CVE-2018-21219",
"lastModified": "2024-11-21T04:03:12.487",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T16:15:14.373",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21213
Vulnerability from fkie_nvd - Published: 2020-04-28 16:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | r7800_firmware | * | |
| netgear | r7800 | - | |
| netgear | r9000_firmware | * | |
| netgear | r9000 | - | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d3600_firmware | * | |
| netgear | d3600 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6",
"versionEndExcluding": "1.0.2.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por el desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50."
}
],
"id": "CVE-2018-21213",
"lastModified": "2024-11-21T04:03:11.563",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T16:15:14.060",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21207
Vulnerability from fkie_nvd - Published: 2020-04-28 16:15 - Updated: 2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | d3600_firmware | * | |
| netgear | d3600 | - | |
| netgear | d6000_firmware | * | |
| netgear | d6000 | - | |
| netgear | d7800_firmware | * | |
| netgear | d7800 | - | |
| netgear | ex2700_firmware | * | |
| netgear | ex2700 | - | |
| netgear | r6100_firmware | * | |
| netgear | r6100 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | - | |
| netgear | r7500_firmware | * | |
| netgear | r7500 | v2 | |
| netgear | r7800_firmware | * | |
| netgear | r7800 | - | |
| netgear | r900_firmware | * | |
| netgear | r900 | - | |
| netgear | wn2000rpt_firmware | * | |
| netgear | wn2000rpt | v3 | |
| netgear | wn3000rp_firmware | * | |
| netgear | wn3000rp | v3 | |
| netgear | wn3100rp_firmware | * | |
| netgear | wn3100rp | v2 | |
| netgear | wndr3700_firmware | * | |
| netgear | wndr3700 | v4 | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | - | |
| netgear | wndr4300_firmware | * | |
| netgear | wndr4300 | v2 | |
| netgear | wndr4500_firmware | * | |
| netgear | wndr4500 | v3 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB",
"versionEndExcluding": "1.0.0.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75",
"versionEndExcluding": "1.0.1.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B",
"versionEndExcluding": "1.0.1.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D",
"versionEndExcluding": "1.0.0.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C",
"versionEndExcluding": "1.0.3.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6",
"versionEndExcluding": "1.0.2.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3ABBD2E7-85AA-4EDA-908C-410D44DD74DC",
"versionEndExcluding": "1.0.2.52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F75EB581-AACC-401D-ACA7-0BCA73D12621",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21",
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30",
"versionEndExcluding": "1.0.2.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6",
"versionEndExcluding": "1.0.0.56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA",
"versionEndExcluding": "1.0.0.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50."
},
{
"lang": "es",
"value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, EX2700 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1. 0.2.52, WN2000RPTv3 versiones anteriores a 1.0.1.20, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50."
}
],
"id": "CVE-2018-21207",
"lastModified": "2024-11-21T04:03:10.640",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-28T16:15:13.700",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-0850 (GCVE-0-2023-0850)
Vulnerability from cvelistv5 – Published: 2023-02-15 21:45 – Updated: 2024-08-02 05:24
VLAI?
Summary
A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability.
Severity ?
CWE
- CWE-404 - Denial of Service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | WNDR3700v2 |
Affected:
1.0.1.14
|
Credits
leetsun (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.449Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit",
"x_transferred"
],
"url": "https://vuldb.com/?id.221153"
},
{
"tags": [
"signature",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.221153"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Interface"
],
"product": "WNDR3700v2",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.1.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetsun (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability."
},
{
"lang": "de",
"value": "Eine problematische Schwachstelle wurde in Netgear WNDR3700v2 1.0.1.14 gefunden. Betroffen davon ist ein unbekannter Prozess der Komponente Web Interface. Durch das Beeinflussen mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "CWE-404 Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T21:10:18.524Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit"
],
"url": "https://vuldb.com/?id.221153"
},
{
"tags": [
"signature"
],
"url": "https://vuldb.com/?ctiid.221153"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-02-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-03-16T10:22:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNDR3700v2 Web Interface denial of service"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-0850",
"datePublished": "2023-02-15T21:45:33.719Z",
"dateReserved": "2023-02-15T21:44:48.964Z",
"dateUpdated": "2024-08-02T05:24:34.449Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0849 (GCVE-0-2023-0849)
Vulnerability from cvelistv5 – Published: 2023-02-15 21:43 – Updated: 2024-08-02 05:24
VLAI?
Summary
A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152.
Severity ?
4.7 (Medium)
4.7 (Medium)
CWE
- CWE-77 - Command Injection
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | WNDR3700v2 |
Affected:
1.0.1.14
|
Credits
leetsun (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.450Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit",
"x_transferred"
],
"url": "https://vuldb.com/?id.221152"
},
{
"tags": [
"signature",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.221152"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Interface"
],
"product": "WNDR3700v2",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.1.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetsun (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152."
},
{
"lang": "de",
"value": "In Netgear WNDR3700v2 1.0.1.14 wurde eine kritische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Komponente Web Interface. Durch Manipulieren mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T21:09:05.334Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit"
],
"url": "https://vuldb.com/?id.221152"
},
{
"tags": [
"signature"
],
"url": "https://vuldb.com/?ctiid.221152"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-02-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-03-16T10:11:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNDR3700v2 Web Interface command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-0849",
"datePublished": "2023-02-15T21:43:27.588Z",
"dateReserved": "2023-02-15T21:42:08.094Z",
"dateUpdated": "2024-08-02T05:24:34.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0848 (GCVE-0-2023-0848)
Vulnerability from cvelistv5 – Published: 2023-02-15 21:31 – Updated: 2024-08-02 05:24
VLAI?
Summary
A vulnerability was found in Netgear WNDR3700v2 1.0.1.14. It has been rated as problematic. This issue affects some unknown processing of the component Web Management Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221147.
Severity ?
5.3 (Medium)
5.3 (Medium)
CWE
- CWE-404 - Denial of Service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | WNDR3700v2 |
Affected:
1.0.1.14
|
Credits
leetsun (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.221147"
},
{
"tags": [
"signature",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.221147"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "WNDR3700v2",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.1.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetsun (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14. It has been rated as problematic. This issue affects some unknown processing of the component Web Management Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221147."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Netgear WNDR3700v2 1.0.1.14 ausgemacht. Sie wurde als problematisch eingestuft. Dies betrifft einen unbekannten Teil der Komponente Web Management Interface. Durch die Manipulation mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "CWE-404 Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T21:07:52.131Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.221147"
},
{
"tags": [
"signature"
],
"url": "https://vuldb.com/?ctiid.221147"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-02-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-03-16T09:45:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNDR3700v2 Web Management Interface denial of service"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-0848",
"datePublished": "2023-02-15T21:31:42.916Z",
"dateReserved": "2023-02-15T21:29:44.397Z",
"dateUpdated": "2024-08-02T05:24:34.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38514 (GCVE-0-2021-38514)
Vulnerability from cvelistv5 – Published: 2021-08-10 23:54 – Updated: 2024-08-04 01:44
VLAI?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22.
Severity ?
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:23.472Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-10T23:54:27",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-38514",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449",
"refsource": "MISC",
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-38514",
"datePublished": "2021-08-10T23:54:27",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:23.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21224 (GCVE-0-2018-21224)
Vulnerability from cvelistv5 – Published: 2020-04-28 16:28 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:38.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-02-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:28:05",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21224",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21224",
"datePublished": "2020-04-28T16:28:05",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:38.997Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21223 (GCVE-0-2018-21223)
Vulnerability from cvelistv5 – Published: 2020-04-28 16:26 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:39.356Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-02-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:26:40",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21223",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21223",
"datePublished": "2020-04-28T16:26:40",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:39.356Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21222 (GCVE-0-2018-21222)
Vulnerability from cvelistv5 – Published: 2020-04-28 16:24 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:39.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-02-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:24:51",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21222",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21222",
"datePublished": "2020-04-28T16:24:51",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:39.447Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-11059 (GCVE-0-2016-11059)
Vulnerability from cvelistv5 – Published: 2020-04-28 16:20 – Updated: 2024-08-06 03:47
VLAI?
Summary
Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T03:47:34.858Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-01-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:20:22",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-11059",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-11059",
"datePublished": "2020-04-28T16:20:22",
"dateReserved": "2020-04-27T00:00:00",
"dateUpdated": "2024-08-06T03:47:34.858Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0850 (GCVE-0-2023-0850)
Vulnerability from nvd – Published: 2023-02-15 21:45 – Updated: 2024-08-02 05:24
VLAI?
Summary
A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability.
Severity ?
CWE
- CWE-404 - Denial of Service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | WNDR3700v2 |
Affected:
1.0.1.14
|
Credits
leetsun (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.449Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit",
"x_transferred"
],
"url": "https://vuldb.com/?id.221153"
},
{
"tags": [
"signature",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.221153"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Interface"
],
"product": "WNDR3700v2",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.1.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetsun (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14 and classified as problematic. This issue affects some unknown processing of the component Web Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221153 was assigned to this vulnerability."
},
{
"lang": "de",
"value": "Eine problematische Schwachstelle wurde in Netgear WNDR3700v2 1.0.1.14 gefunden. Betroffen davon ist ein unbekannter Prozess der Komponente Web Interface. Durch das Beeinflussen mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "CWE-404 Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T21:10:18.524Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit"
],
"url": "https://vuldb.com/?id.221153"
},
{
"tags": [
"signature"
],
"url": "https://vuldb.com/?ctiid.221153"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-02-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-03-16T10:22:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNDR3700v2 Web Interface denial of service"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-0850",
"datePublished": "2023-02-15T21:45:33.719Z",
"dateReserved": "2023-02-15T21:44:48.964Z",
"dateUpdated": "2024-08-02T05:24:34.449Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0849 (GCVE-0-2023-0849)
Vulnerability from nvd – Published: 2023-02-15 21:43 – Updated: 2024-08-02 05:24
VLAI?
Summary
A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152.
Severity ?
4.7 (Medium)
4.7 (Medium)
CWE
- CWE-77 - Command Injection
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | WNDR3700v2 |
Affected:
1.0.1.14
|
Credits
leetsun (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.450Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit",
"x_transferred"
],
"url": "https://vuldb.com/?id.221152"
},
{
"tags": [
"signature",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.221152"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Interface"
],
"product": "WNDR3700v2",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.1.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetsun (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152."
},
{
"lang": "de",
"value": "In Netgear WNDR3700v2 1.0.1.14 wurde eine kritische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Komponente Web Interface. Durch Manipulieren mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T21:09:05.334Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"exploit"
],
"url": "https://vuldb.com/?id.221152"
},
{
"tags": [
"signature"
],
"url": "https://vuldb.com/?ctiid.221152"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-02-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-03-16T10:11:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNDR3700v2 Web Interface command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-0849",
"datePublished": "2023-02-15T21:43:27.588Z",
"dateReserved": "2023-02-15T21:42:08.094Z",
"dateUpdated": "2024-08-02T05:24:34.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0848 (GCVE-0-2023-0848)
Vulnerability from nvd – Published: 2023-02-15 21:31 – Updated: 2024-08-02 05:24
VLAI?
Summary
A vulnerability was found in Netgear WNDR3700v2 1.0.1.14. It has been rated as problematic. This issue affects some unknown processing of the component Web Management Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221147.
Severity ?
5.3 (Medium)
5.3 (Medium)
CWE
- CWE-404 - Denial of Service
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | WNDR3700v2 |
Affected:
1.0.1.14
|
Credits
leetsun (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.221147"
},
{
"tags": [
"signature",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.221147"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "WNDR3700v2",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "1.0.1.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "leetsun (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Netgear WNDR3700v2 1.0.1.14. It has been rated as problematic. This issue affects some unknown processing of the component Web Management Interface. The manipulation leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221147."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Netgear WNDR3700v2 1.0.1.14 ausgemacht. Sie wurde als problematisch eingestuft. Dies betrifft einen unbekannten Teil der Komponente Web Management Interface. Durch die Manipulation mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "CWE-404 Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T21:07:52.131Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.221147"
},
{
"tags": [
"signature"
],
"url": "https://vuldb.com/?ctiid.221147"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-02-15T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-02-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-03-16T09:45:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netgear WNDR3700v2 Web Management Interface denial of service"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-0848",
"datePublished": "2023-02-15T21:31:42.916Z",
"dateReserved": "2023-02-15T21:29:44.397Z",
"dateUpdated": "2024-08-02T05:24:34.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38514 (GCVE-0-2021-38514)
Vulnerability from nvd – Published: 2021-08-10 23:54 – Updated: 2024-08-04 01:44
VLAI?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22.
Severity ?
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:44:23.472Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-10T23:54:27",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-38514",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449",
"refsource": "MISC",
"url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-38514",
"datePublished": "2021-08-10T23:54:27",
"dateReserved": "2021-08-10T00:00:00",
"dateUpdated": "2024-08-04T01:44:23.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21224 (GCVE-0-2018-21224)
Vulnerability from nvd – Published: 2020-04-28 16:28 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:38.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-02-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:28:05",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21224",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21224",
"datePublished": "2020-04-28T16:28:05",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:38.997Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21223 (GCVE-0-2018-21223)
Vulnerability from nvd – Published: 2020-04-28 16:26 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:39.356Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-02-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:26:40",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21223",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21223",
"datePublished": "2020-04-28T16:26:40",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:39.356Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21222 (GCVE-0-2018-21222)
Vulnerability from nvd – Published: 2020-04-28 16:24 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:39.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-02-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:24:51",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21222",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21222",
"datePublished": "2020-04-28T16:24:51",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:39.447Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-11059 (GCVE-0-2016-11059)
Vulnerability from nvd – Published: 2020-04-28 16:20 – Updated: 2024-08-06 03:47
VLAI?
Summary
Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T03:47:34.858Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-01-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T16:20:22",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-11059",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-11059",
"datePublished": "2020-04-28T16:20:22",
"dateReserved": "2020-04-27T00:00:00",
"dateUpdated": "2024-08-06T03:47:34.858Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}