All the vulnerabilites related to netgear - wndr4500_firmware
cve-2019-20752
Vulnerability from cvelistv5
Published
2020-04-16 21:04
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:09.221Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060967/Security-Advisory-for-Site-Stored-Cross-Scripting-on-Some-Gateways-Routers-and-WiFi-Systems-PSV-2018-0250" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T21:04:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060967/Security-Advisory-for-Site-Stored-Cross-Scripting-on-Some-Gateways-Routers-and-WiFi-Systems-PSV-2018-0250" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20752", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060967/Security-Advisory-for-Site-Stored-Cross-Scripting-on-Some-Gateways-Routers-and-WiFi-Systems-PSV-2018-0250", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060967/Security-Advisory-for-Site-Stored-Cross-Scripting-on-Some-Gateways-Routers-and-WiFi-Systems-PSV-2018-0250" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20752", "datePublished": "2020-04-16T21:04:31", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:09.221Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18714
Vulnerability from cvelistv5
Published
2020-04-24 13:33
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
NETGEAR WNDR4500v3 devices before 1.0.0.48 are affected by denial of service.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:42.654Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "NETGEAR WNDR4500v3 devices before 1.0.0.48 are affected by denial of service." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T13:33:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18714", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "NETGEAR WNDR4500v3 devices before 1.0.0.48 are affected by denial of service." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18714", "datePublished": "2020-04-24T13:33:00", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:42.654Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20728
Vulnerability from cvelistv5
Published
2020-04-16 19:05
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6400 before 1.0.0.74, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.102, DGND2200Bv4 before 1.0.0.102, DM200 before 1.0.0.52, JNDR3000 before 1.0.0.22, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, RBW30 before 2.1.2.6, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, WNR2000v5 before 1.0.0.64, and WNR3500Lv2 before 1.2.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.903Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061199/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2017-315" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6400 before 1.0.0.74, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.102, DGND2200Bv4 before 1.0.0.102, DM200 before 1.0.0.52, JNDR3000 before 1.0.0.22, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, RBW30 before 2.1.2.6, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, WNR2000v5 before 1.0.0.64, and WNR3500Lv2 before 1.2.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:L/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:05:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061199/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2017-315" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20728", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6400 before 1.0.0.74, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.102, DGND2200Bv4 before 1.0.0.102, DM200 before 1.0.0.52, JNDR3000 before 1.0.0.22, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, RBW30 before 2.1.2.6, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, WNR2000v5 before 1.0.0.64, and WNR3500Lv2 before 1.2.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:L/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061199/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2017-315", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061199/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2017-315" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20728", "datePublished": "2020-04-16T19:05:04", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.903Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20729
Vulnerability from cvelistv5
Published
2020-04-16 19:08
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JNDR3000 before 1.0.0.22, R6250 before 1.0.4.26, R6300v2 before 1.0.4.22, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R6900P before 1.3.1.26, R7000P before 1.3.1.26, R7300DST before 1.0.0.62, R7900 before 1.0.2.16, R8000 before 1.0.4.18, R7900P before 1.4.1.42, R8000P before 1.4.1.42, R8300 before 1.0.2.116, R8500 before 1.0.2.116, WNDR3400v3 before 1.0.1.18, WNDR4500v2 before 1.0.0.68, and WNR3500Lv2 before 1.2.0.48.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.543Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JNDR3000 before 1.0.0.22, R6250 before 1.0.4.26, R6300v2 before 1.0.4.22, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R6900P before 1.3.1.26, R7000P before 1.3.1.26, R7300DST before 1.0.0.62, R7900 before 1.0.2.16, R8000 before 1.0.4.18, R7900P before 1.4.1.42, R8000P before 1.4.1.42, R8300 before 1.0.2.116, R8500 before 1.0.2.116, WNDR3400v3 before 1.0.1.18, WNDR4500v2 before 1.0.0.68, and WNR3500Lv2 before 1.2.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:L/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:08:24", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20729", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JNDR3000 before 1.0.0.22, R6250 before 1.0.4.26, R6300v2 before 1.0.4.22, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R6900P before 1.3.1.26, R7000P before 1.3.1.26, R7300DST before 1.0.0.62, R7900 before 1.0.2.16, R8000 before 1.0.4.18, R7900P before 1.4.1.42, R8000P before 1.4.1.42, R8300 before 1.0.2.116, R8500 before 1.0.2.116, WNDR3400v3 before 1.0.1.18, WNDR4500v2 before 1.0.0.68, and WNR3500Lv2 before 1.2.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:L/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20729", "datePublished": "2020-04-16T19:08:24", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.543Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18773
Vulnerability from cvelistv5
Published
2020-04-22 14:46
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.267Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:46:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18773", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18773", "datePublished": "2020-04-22T14:46:18", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:44.267Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18705
Vulnerability from cvelistv5
Published
2020-04-24 14:03
Modified
2024-08-05 21:28
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:28:55.955Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053197/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0526" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:03:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053197/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0526" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18705", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053197/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0526", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053197/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0526" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18705", "datePublished": "2020-04-24T14:03:01", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:28:55.955Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21206
Vulnerability from cvelistv5
Published
2020-04-28 15:14
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.234Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055143/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2567" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:14:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055143/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2567" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21206", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055143/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2567", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055143/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2567" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21206", "datePublished": "2020-04-28T15:14:12", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.234Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2016-5638
Vulnerability from cvelistv5
Published
2018-07-24 15:00
Modified
2024-08-06 01:07
Severity ?
EPSS score ?
Summary
There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie_ping.htm or genie_ping2.htm or genie_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz & 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T01:07:59.943Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WNDR4500", "vendor": "Netgear", "versions": [ { "status": "affected", "version": "V1.0.1.40_1.0.6877" } ] } ], "datePublic": "2017-01-03T00:00:00", "descriptions": [ { "lang": "en", "value": "There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie_ping.htm or genie_ping2.htm or genie_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz \u0026 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-24T14:57:01", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html" } ], "solutions": [ { "lang": "en", "value": "Netgear has released firmware version 1.0.0.52 for DGN2200 \u0026 1.0.0.28 for DGND3700 to address this issue." } ], "source": { "discovery": "UNKNOWN" }, "title": "Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877 reveals some sensitive information such as 2.4GHz \u0026 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2016-5638", "STATE": "PUBLIC", "TITLE": "Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877 reveals some sensitive information such as 2.4GHz \u0026 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WNDR4500", "version": { "version_data": [ { "affected": "=", "version_affected": "=", "version_name": "V1.0.1.40_1.0.6877", "version_value": "V1.0.1.40_1.0.6877" } ] } } ] }, "vendor_name": "Netgear" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie_ping.htm or genie_ping2.htm or genie_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz \u0026 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319" } ] } ] }, "references": { "reference_data": [ { "name": "https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html", "refsource": "MISC", "url": "https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html" } ] }, "solution": [ { "lang": "en", "value": "Netgear has released firmware version 1.0.0.52 for DGN2200 \u0026 1.0.0.28 for DGND3700 to address this issue." } ], "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2016-5638", "datePublished": "2018-07-24T15:00:00", "dateReserved": "2016-06-16T00:00:00", "dateUpdated": "2024-08-06T01:07:59.943Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21204
Vulnerability from cvelistv5
Published
2020-04-28 15:11
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.305Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055145/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2569" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:11:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055145/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2569" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21204", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055145/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2569", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055145/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2569" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21204", "datePublished": "2020-04-28T15:11:56", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.305Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21213
Vulnerability from cvelistv5
Published
2020-04-28 15:40
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.542Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:40:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21213", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21213", "datePublished": "2020-04-28T15:40:20", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.542Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21207
Vulnerability from cvelistv5
Published
2020-04-28 15:15
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.332Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:15:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21207", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21207", "datePublished": "2020-04-28T15:15:12", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.332Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21172
Vulnerability from cvelistv5
Published
2020-04-27 17:38
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.153Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055186/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2631" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:38:02", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055186/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2631" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21172", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055186/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2631", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055186/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2631" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21172", "datePublished": "2020-04-27T17:38:02", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.153Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20688
Vulnerability from cvelistv5
Published
2020-04-16 14:23
Modified
2024-08-05 02:46
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:46:10.437Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061451/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0142" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T14:23:55", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061451/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0142" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20688", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061451/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0142", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061451/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0142" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20688", "datePublished": "2020-04-16T14:23:55", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:46:10.437Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20735
Vulnerability from cvelistv5
Published
2020-04-16 19:13
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before V1.0.0.75, D6100 before V1.0.0.63, R7800 before v1.0.2.52, R8900 before v1.0.4.2, R9000 before v1.0.4.2, RBK50 before v2.3.0.32, RBR50 before v2.3.0.32, RBS50 before v2.3.0.32, WNDR3700v4 before V1.0.2.102, WNDR4300v1 before V1.0.2.104, WNDR4300v2 before v1.0.0.58, WNDR4500v3 before v1.0.0.58, WNR2000v5 before v1.0.0.68, and XR500 before V2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before V1.0.0.75, D6100 before V1.0.0.63, R7800 before v1.0.2.52, R8900 before v1.0.4.2, R9000 before v1.0.4.2, RBK50 before v2.3.0.32, RBR50 before v2.3.0.32, RBS50 before v2.3.0.32, WNDR3700v4 before V1.0.2.102, WNDR4300v1 before V1.0.2.104, WNDR4300v2 before v1.0.0.58, WNDR4500v3 before v1.0.0.58, WNR2000v5 before v1.0.0.68, and XR500 before V2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:13:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20735", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before V1.0.0.75, D6100 before V1.0.0.63, R7800 before v1.0.2.52, R8900 before v1.0.4.2, R9000 before v1.0.4.2, RBK50 before v2.3.0.32, RBR50 before v2.3.0.32, RBS50 before v2.3.0.32, WNDR3700v4 before V1.0.2.102, WNDR4300v1 before V1.0.2.104, WNDR4300v2 before v1.0.0.58, WNDR4500v3 before v1.0.0.58, WNR2000v5 before v1.0.0.68, and XR500 before V2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20735", "datePublished": "2020-04-16T19:13:41", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21177
Vulnerability from cvelistv5
Published
2020-04-27 19:48
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.997Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055181/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2622" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T19:48:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055181/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2622" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21177", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055181/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2622", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055181/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2622" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21177", "datePublished": "2020-04-27T19:48:30", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.997Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21178
Vulnerability from cvelistv5
Published
2020-04-27 20:09
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.278Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055180/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2621" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T20:09:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055180/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2621" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21178", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055180/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2621", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055180/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2621" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21178", "datePublished": "2020-04-27T20:09:01", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.278Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21179
Vulnerability from cvelistv5
Published
2020-04-27 20:10
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.199Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055179/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2620" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T20:10:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055179/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2620" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21179", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055179/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2620", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055179/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2620" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21179", "datePublished": "2020-04-27T20:10:09", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.199Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21187
Vulnerability from cvelistv5
Published
2020-04-28 14:54
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.518Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055170/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2608" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:54:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055170/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2608" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21187", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055170/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2608", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055170/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2608" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21187", "datePublished": "2020-04-28T14:54:53", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.518Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21202
Vulnerability from cvelistv5
Published
2020-04-28 15:10
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.454Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055147/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2590" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:10:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055147/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2590" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21202", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055147/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2590", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055147/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2590" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21202", "datePublished": "2020-04-28T15:10:04", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.454Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38514
Vulnerability from cvelistv5
Published
2021-08-10 23:54
Modified
2024-08-04 01:44
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:44:23.472Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 2.4, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:N/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T23:54:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-38514", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:N/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449", "refsource": "MISC", "url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-38514", "datePublished": "2021-08-10T23:54:27", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-08-04T01:44:23.472Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18713
Vulnerability from cvelistv5
Published
2020-04-24 13:34
Modified
2024-08-05 21:28
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:28:56.036Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053135/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0114" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T13:34:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053135/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0114" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18713", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053135/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0114", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053135/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0114" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18713", "datePublished": "2020-04-24T13:34:07", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:28:56.036Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21175
Vulnerability from cvelistv5
Published
2020-04-27 19:39
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.583Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055183/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2624" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T19:39:47", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055183/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2624" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21175", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055183/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2624", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055183/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2624" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21175", "datePublished": "2020-04-27T19:39:47", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.583Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21144
Vulnerability from cvelistv5
Published
2020-04-21 21:01
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects DM200 before 1.0.0.52, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.16, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.302Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059489/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3166" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects DM200 before 1.0.0.52, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.16, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-21T21:01:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059489/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3166" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21144", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects DM200 before 1.0.0.52, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.16, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059489/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3166", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059489/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3166" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21144", "datePublished": "2020-04-21T21:01:07", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.302Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20714
Vulnerability from cvelistv5
Published
2020-04-16 15:39
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:07.487Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T15:39:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20714", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20714", "datePublished": "2020-04-16T15:39:29", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:07.487Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21174
Vulnerability from cvelistv5
Published
2020-04-27 18:22
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.996Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055184/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2625" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T18:22:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055184/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2625" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21174", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055184/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2625", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055184/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2625" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21174", "datePublished": "2020-04-27T18:22:06", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.996Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20738
Vulnerability from cvelistv5
Published
2020-04-16 19:17
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.34, JNR1010v2 before 1.1.0.50, JWNR2010v5 before 1.1.0.50, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, R6020 before 1.0.0.30, R6080 before 1.0.0.30, R6100 before 1.0.1.16, R6120 before 1.0.0.40, R6700v2 before 1.2.0.14, R6800 before 1.2.0.14, R6900v2 before 1.2.0.14, R7500v2 before 1.0.3.26, R7800 before 1.0.2.46, R9000 before 1.0.4.2, WN3000RPv2 before 1.0.0.52, WN3000RPv3 before 1.0.2.78, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.50, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.50, and WNR2050 before 1.1.0.50. NOTE: this may be a result of an incomplete fix for CVE-2017-18866.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.601Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061187/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2016-0100" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.34, JNR1010v2 before 1.1.0.50, JWNR2010v5 before 1.1.0.50, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, R6020 before 1.0.0.30, R6080 before 1.0.0.30, R6100 before 1.0.1.16, R6120 before 1.0.0.40, R6700v2 before 1.2.0.14, R6800 before 1.2.0.14, R6900v2 before 1.2.0.14, R7500v2 before 1.0.3.26, R7800 before 1.0.2.46, R9000 before 1.0.4.2, WN3000RPv2 before 1.0.0.52, WN3000RPv3 before 1.0.2.78, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.50, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.50, and WNR2050 before 1.1.0.50. NOTE: this may be a result of an incomplete fix for CVE-2017-18866." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-05-05T22:26:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061187/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2016-0100" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20738", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.34, JNR1010v2 before 1.1.0.50, JWNR2010v5 before 1.1.0.50, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, R6020 before 1.0.0.30, R6080 before 1.0.0.30, R6100 before 1.0.1.16, R6120 before 1.0.0.40, R6700v2 before 1.2.0.14, R6800 before 1.2.0.14, R6900v2 before 1.2.0.14, R7500v2 before 1.0.3.26, R7800 before 1.0.2.46, R9000 before 1.0.4.2, WN3000RPv2 before 1.0.0.52, WN3000RPv3 before 1.0.2.78, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.50, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.50, and WNR2050 before 1.1.0.50. NOTE: this may be a result of an incomplete fix for CVE-2017-18866." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061187/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2016-0100", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061187/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2016-0100" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20738", "datePublished": "2020-04-16T19:17:40", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.601Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20725
Vulnerability from cvelistv5
Published
2020-04-16 19:01
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.602Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061203/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0143" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:01:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061203/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0143" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20725", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061203/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0143", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061203/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0143" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20725", "datePublished": "2020-04-16T19:01:52", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.602Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21193
Vulnerability from cvelistv5
Published
2020-04-28 14:59
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.275Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055164/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2602" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:59:45", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055164/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2602" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21193", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055164/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2602", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055164/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2602" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21193", "datePublished": "2020-04-28T14:59:45", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.275Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21194
Vulnerability from cvelistv5
Published
2020-04-28 15:00
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.290Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055163/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2601" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:00:23", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055163/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2601" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21194", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055163/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2601", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055163/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2601" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21194", "datePublished": "2020-04-28T15:00:23", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.290Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20753
Vulnerability from cvelistv5
Published
2020-04-16 21:06
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects DGN2200v1 before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.78, D6220 before 1.0.0.44, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900 before 1.0.2.16, R7000P before 1.3.2.34, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.2.34, R7000 before 1.0.9.28, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.974Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060629/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0085" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects DGN2200v1 before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.78, D6220 before 1.0.0.44, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900 before 1.0.2.16, R7000P before 1.3.2.34, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.2.34, R7000 before 1.0.9.28, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T21:06:54", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060629/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0085" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20753", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects DGN2200v1 before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.78, D6220 before 1.0.0.44, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900 before 1.0.2.16, R7000P before 1.3.2.34, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.2.34, R7000 before 1.0.9.28, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060629/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0085", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060629/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0085" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20753", "datePublished": "2020-04-16T21:06:54", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.974Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21148
Vulnerability from cvelistv5
Published
2020-04-21 21:08
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.303Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059485/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3157" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-21T21:08:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059485/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3157" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21148", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059485/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3157", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059485/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3157" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21148", "datePublished": "2020-04-21T21:08:00", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.303Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18749
Vulnerability from cvelistv5
Published
2020-04-23 15:25
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by CSRF. This affects JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.976Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T15:25:38", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18749", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by CSRF. This affects JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18749", "datePublished": "2020-04-23T15:25:38", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.976Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18711
Vulnerability from cvelistv5
Published
2020-04-24 13:42
Modified
2024-08-05 21:28
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:28:56.034Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053137/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2016-0131" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:L/I:L/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T13:42:58", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053137/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2016-0131" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18711", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:L/I:L/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053137/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2016-0131", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053137/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2016-0131" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18711", "datePublished": "2020-04-24T13:42:58", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:28:56.034Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21185
Vulnerability from cvelistv5
Published
2020-04-28 12:54
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.691Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T12:54:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21185", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21185", "datePublished": "2020-04-28T12:54:09", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.691Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20746
Vulnerability from cvelistv5
Published
2020-04-16 20:57
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by reflected XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.8, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:09.332Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060973/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0252" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by reflected XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.8, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T20:57:38", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060973/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0252" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20746", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by reflected XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.8, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060973/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0252", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060973/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0252" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20746", "datePublished": "2020-04-16T20:57:38", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:09.332Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20767
Vulnerability from cvelistv5
Published
2020-04-15 13:42
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, D3600 before 1.0.0.75, D6000 before 1.0.0.75, R9000 before 1.0.4.26, R8900 before 1.0.4.26, R7800 before 1.0.2.52, WNDR4500v3 before 1.0.0.58, WNDR4300v2 before 1.0.0.58, WNDR4300 before 1.0.2.104, WNDR3700v4 before 1.0.2.102, and WNR2000v5 before 1.0.0.66.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.913Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060632/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0116" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, D3600 before 1.0.0.75, D6000 before 1.0.0.75, R9000 before 1.0.4.26, R8900 before 1.0.4.26, R7800 before 1.0.2.52, WNDR4500v3 before 1.0.0.58, WNDR4300v2 before 1.0.0.58, WNDR4300 before 1.0.2.104, WNDR3700v4 before 1.0.2.102, and WNR2000v5 before 1.0.0.66." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-15T13:42:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060632/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0116" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20767", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, D3600 before 1.0.0.75, D6000 before 1.0.0.75, R9000 before 1.0.4.26, R8900 before 1.0.4.26, R7800 before 1.0.2.52, WNDR4500v3 before 1.0.0.58, WNDR4300v2 before 1.0.0.58, WNDR4300 before 1.0.2.104, WNDR3700v4 before 1.0.2.102, and WNR2000v5 before 1.0.0.66." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060632/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0116", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060632/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0116" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20767", "datePublished": "2020-04-15T13:42:05", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.913Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20717
Vulnerability from cvelistv5
Published
2020-04-16 15:43
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:07.567Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:N/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T15:43:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20717", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:N/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20717", "datePublished": "2020-04-16T15:43:18", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:07.567Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21219
Vulnerability from cvelistv5
Published
2020-04-28 15:44
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.919Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:44:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21219", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21219", "datePublished": "2020-04-28T15:44:48", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.919Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21190
Vulnerability from cvelistv5
Published
2020-04-28 14:57
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.204Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055167/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2605" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:57:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055167/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2605" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21190", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055167/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2605", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055167/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2605" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21190", "datePublished": "2020-04-28T14:57:41", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.204Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18757
Vulnerability from cvelistv5
Published
2020-04-22 16:06
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.16, R7500 before 1.0.0.116, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR4300v2 before 1.0.0.48, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.917Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.16, R7500 before 1.0.0.116, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR4300v2 before 1.0.0.48, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:H/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T16:06:21", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18757", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.16, R7500 before 1.0.0.116, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR4300v2 before 1.0.0.48, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:H/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18757", "datePublished": "2020-04-22T16:06:21", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.917Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20727
Vulnerability from cvelistv5
Published
2020-04-16 19:04
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.895Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061201/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2018-0139" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:04:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061201/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2018-0139" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20727", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061201/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2018-0139", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061201/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2018-0139" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20727", "datePublished": "2020-04-16T19:04:09", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.895Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21113
Vulnerability from cvelistv5
Published
2020-04-22 14:38
Modified
2024-08-05 12:19
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:19:27.629Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-12-07T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:38:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21113", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21113", "datePublished": "2020-04-22T14:38:25", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:19:27.629Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21146
Vulnerability from cvelistv5
Published
2020-04-21 21:04
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.901Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059487/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3159" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-21T21:04:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059487/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3159" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21146", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059487/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3159", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059487/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3159" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21146", "datePublished": "2020-04-21T21:04:41", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.901Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20726
Vulnerability from cvelistv5
Published
2020-04-16 19:02
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.658Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:02:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20726", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20726", "datePublished": "2020-04-16T19:02:25", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.658Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21197
Vulnerability from cvelistv5
Published
2020-04-28 15:03
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.686Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055152/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2596" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:03:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055152/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2596" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21197", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055152/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2596", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055152/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2596" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21197", "datePublished": "2020-04-28T15:03:19", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.686Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20721
Vulnerability from cvelistv5
Published
2020-04-16 16:19
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:07.558Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T16:19:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20721", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20721", "datePublished": "2020-04-16T16:19:28", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:07.558Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21228
Vulnerability from cvelistv5
Published
2020-04-24 14:34
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, EX6100v2 before 1.0.1.50, EX6150v2 before 1.0.1.50, EX6200v2 before 1.0.1.44, EX6400 before 1.0.1.60, EX7300 before 1.0.1.60, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.2.30, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.285Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0607" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, EX6100v2 before 1.0.1.50, EX6150v2 before 1.0.1.50, EX6200v2 before 1.0.1.44, EX6400 before 1.0.1.60, EX7300 before 1.0.1.60, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.2.30, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:34:08", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0607" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21228", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, EX6100v2 before 1.0.1.50, EX6150v2 before 1.0.1.50, EX6200v2 before 1.0.1.44, EX6400 before 1.0.1.60, EX7300 before 1.0.1.60, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.2.30, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0607", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0607" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21228", "datePublished": "2020-04-24T14:34:08", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.285Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21168
Vulnerability from cvelistv5
Published
2020-04-27 17:30
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D7000 before 1.0.1.52, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.362Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055190/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3059" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D7000 before 1.0.1.52, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:30:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055190/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3059" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21168", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D7000 before 1.0.1.52, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055190/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3059", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055190/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3059" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21168", "datePublished": "2020-04-27T17:30:29", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.362Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18740
Vulnerability from cvelistv5
Published
2020-04-23 16:00
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.61, D6000 before 1.0.0.61, D6100 before 1.0.0.55, D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.475Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051515/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0615" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.61, D6000 before 1.0.0.61, D6100 before 1.0.0.55, D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:L/I:L/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T16:00:10", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051515/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0615" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18740", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.61, D6000 before 1.0.0.61, D6100 before 1.0.0.55, D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:L/I:L/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051515/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0615", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051515/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0615" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18740", "datePublished": "2020-04-23T16:00:10", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.475Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21139
Vulnerability from cvelistv5
Published
2020-04-23 20:12
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.58, D6200 before 1.1.00.30, D6220 before 1.0.0.46, D6400 before 1.0.0.82, D7000 before 1.0.1.68, D7000v2 before 1.0.0.51, D7800 before 1.0.1.42, D8500 before 1.0.3.42, DC112A before 1.0.0.40, DGN2200Bv4 before 1.0.0.102, DGN2200v4 before 1.0.0.102, JNR1010v2 before 1.1.0.54, JR6150 before 1.0.1.18, JWNR2010v5 before 1.1.0.54, PR2000 before 1.0.0.24, R6020 before 1.0.0.34, R6050 before 1.0.1.18, R6080 before 1.0.0.34, R6100 before 1.0.1.22, R6120 before 1.0.0.42, R6220 before 1.1.0.68, R6250 before 1.0.4.30, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.60, R6700 before 1.0.1.48, R6700v2 before 1.2.0.24, R6800 before 1.2.0.24, R6900 before 1.0.1.48, R6900P before 1.3.1.44, R6900v2 before 1.2.0.24, R7000 before 1.0.9.34, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7300 before 1.0.0.68, R7500 before 1.0.0.124, R7500v2 before 1.0.3.38, R7900 before 1.0.2.16, R7900P before 1.4.1.24, R8000 before 1.0.4.18, R8000P before 1.4.1.24, R8300 before 1.0.2.122, R8500 before 1.0.2.122, WN3000RP before 1.0.0.68, WN3000RPv2 before 1.0.0.68, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR1000v4 before 1.1.0.54, WNR2020 before 1.1.0.54, WNR2050 before 1.1.0.54, and WNR3500Lv2 before 1.2.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.327Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060220/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-Smart-Cradles-PSV-2017-2198" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-09-25T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.58, D6200 before 1.1.00.30, D6220 before 1.0.0.46, D6400 before 1.0.0.82, D7000 before 1.0.1.68, D7000v2 before 1.0.0.51, D7800 before 1.0.1.42, D8500 before 1.0.3.42, DC112A before 1.0.0.40, DGN2200Bv4 before 1.0.0.102, DGN2200v4 before 1.0.0.102, JNR1010v2 before 1.1.0.54, JR6150 before 1.0.1.18, JWNR2010v5 before 1.1.0.54, PR2000 before 1.0.0.24, R6020 before 1.0.0.34, R6050 before 1.0.1.18, R6080 before 1.0.0.34, R6100 before 1.0.1.22, R6120 before 1.0.0.42, R6220 before 1.1.0.68, R6250 before 1.0.4.30, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.60, R6700 before 1.0.1.48, R6700v2 before 1.2.0.24, R6800 before 1.2.0.24, R6900 before 1.0.1.48, R6900P before 1.3.1.44, R6900v2 before 1.2.0.24, R7000 before 1.0.9.34, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7300 before 1.0.0.68, R7500 before 1.0.0.124, R7500v2 before 1.0.3.38, R7900 before 1.0.2.16, R7900P before 1.4.1.24, R8000 before 1.0.4.18, R8000P before 1.4.1.24, R8300 before 1.0.2.122, R8500 before 1.0.2.122, WN3000RP before 1.0.0.68, WN3000RPv2 before 1.0.0.68, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR1000v4 before 1.1.0.54, WNR2020 before 1.1.0.54, WNR2050 before 1.1.0.54, and WNR3500Lv2 before 1.2.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T20:12:33", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060220/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-Smart-Cradles-PSV-2017-2198" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21139", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.58, D6200 before 1.1.00.30, D6220 before 1.0.0.46, D6400 before 1.0.0.82, D7000 before 1.0.1.68, D7000v2 before 1.0.0.51, D7800 before 1.0.1.42, D8500 before 1.0.3.42, DC112A before 1.0.0.40, DGN2200Bv4 before 1.0.0.102, DGN2200v4 before 1.0.0.102, JNR1010v2 before 1.1.0.54, JR6150 before 1.0.1.18, JWNR2010v5 before 1.1.0.54, PR2000 before 1.0.0.24, R6020 before 1.0.0.34, R6050 before 1.0.1.18, R6080 before 1.0.0.34, R6100 before 1.0.1.22, R6120 before 1.0.0.42, R6220 before 1.1.0.68, R6250 before 1.0.4.30, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.60, R6700 before 1.0.1.48, R6700v2 before 1.2.0.24, R6800 before 1.2.0.24, R6900 before 1.0.1.48, R6900P before 1.3.1.44, R6900v2 before 1.2.0.24, R7000 before 1.0.9.34, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7300 before 1.0.0.68, R7500 before 1.0.0.124, R7500v2 before 1.0.3.38, R7900 before 1.0.2.16, R7900P before 1.4.1.24, R8000 before 1.0.4.18, R8000P before 1.4.1.24, R8300 before 1.0.2.122, R8500 before 1.0.2.122, WN3000RP before 1.0.0.68, WN3000RPv2 before 1.0.0.68, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR1000v4 before 1.1.0.54, WNR2020 before 1.1.0.54, WNR2050 before 1.1.0.54, and WNR3500Lv2 before 1.2.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060220/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-Smart-Cradles-PSV-2017-2198", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060220/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-Smart-Cradles-PSV-2017-2198" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21139", "datePublished": "2020-04-23T20:12:33", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.327Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20751
Vulnerability from cvelistv5
Published
2020-04-16 21:01
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.662Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T21:01:32", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20751", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20751", "datePublished": "2020-04-16T21:01:32", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.662Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21141
Vulnerability from cvelistv5
Published
2020-04-21 20:57
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.322Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-21T20:57:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21141", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21141", "datePublished": "2020-04-21T20:57:19", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.322Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18867
Vulnerability from cvelistv5
Published
2020-05-05 13:47
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6100 before 1.0.0.55, D7800 before V1.0.1.24, R7100LG before V1.0.0.32, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.311Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000049554/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2198" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6100 before 1.0.0.55, D7800 before V1.0.1.24, R7100LG before V1.0.0.32, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:P/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-05-05T13:47:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000049554/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2198" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18867", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6100 before 1.0.0.55, D7800 before V1.0.1.24, R7100LG before V1.0.0.32, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:P/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049554/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2198", "refsource": "MISC", "url": "https://kb.netgear.com/000049554/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2198" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18867", "datePublished": "2020-05-05T13:47:18", "dateReserved": "2020-05-05T00:00:00", "dateUpdated": "2024-08-05T21:37:44.311Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-17372
Vulnerability from cvelistv5
Published
2019-10-09 12:06
Modified
2024-08-05 01:40
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices allow remote attackers to disable all authentication requirements by visiting genieDisableLanChanged.cgi. The attacker can then, for example, visit MNU_accessPassword_recovered.html to obtain a valid new admin password. This affects AC1450, D8500, DC112A, JNDR3000, LG2200D, R4500, R6200, R6200V2, R6250, R6300, R6300v2, R6400, R6700, R6900P, R6900, R7000P, R7000, R7100LG, R7300, R7900, R8000, R8300, R8500, WGR614v10, WN2500RPv2, WNDR3400v2, WNDR3700v3, WNDR4000, WNDR4500, WNDR4500v2, WNR1000, WNR1000v3, WNR3500L, and WNR3500L.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T01:40:15.201Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices allow remote attackers to disable all authentication requirements by visiting genieDisableLanChanged.cgi. The attacker can then, for example, visit MNU_accessPassword_recovered.html to obtain a valid new admin password. This affects AC1450, D8500, DC112A, JNDR3000, LG2200D, R4500, R6200, R6200V2, R6250, R6300, R6300v2, R6400, R6700, R6900P, R6900, R7000P, R7000, R7100LG, R7300, R7900, R8000, R8300, R8500, WGR614v10, WN2500RPv2, WNDR3400v2, WNDR3700v3, WNDR4000, WNDR4500, WNDR4500v2, WNR1000, WNR1000v3, WNR3500L, and WNR3500L." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-09T12:06:57", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-17372", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices allow remote attackers to disable all authentication requirements by visiting genieDisableLanChanged.cgi. The attacker can then, for example, visit MNU_accessPassword_recovered.html to obtain a valid new admin password. This affects AC1450, D8500, DC112A, JNDR3000, LG2200D, R4500, R6200, R6200V2, R6250, R6300, R6300v2, R6400, R6700, R6900P, R6900, R7000P, R7000, R7100LG, R7300, R7900, R8000, R8300, R8500, WGR614v10, WN2500RPv2, WNDR3400v2, WNDR3700v3, WNDR4000, WNDR4500, WNDR4500v2, WNR1000, WNR1000v3, WNR3500L, and WNR3500L." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md", "refsource": "MISC", "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-17372", "datePublished": "2019-10-09T12:06:57", "dateReserved": "2019-10-09T00:00:00", "dateUpdated": "2024-08-05T01:40:15.201Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21165
Vulnerability from cvelistv5
Published
2020-04-23 21:22
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.024Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-03-02T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T21:22:55", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21165", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21165", "datePublished": "2020-04-23T21:22:55", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.024Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2016-11059
Vulnerability from cvelistv5
Published
2020-04-28 16:20
Modified
2024-08-06 03:47
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T03:47:34.858Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-01-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T16:20:22", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-11059", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers", "refsource": "CONFIRM", "url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-11059", "datePublished": "2020-04-28T16:20:22", "dateReserved": "2020-04-27T00:00:00", "dateUpdated": "2024-08-06T03:47:34.858Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18764
Vulnerability from cvelistv5
Published
2020-04-22 15:42
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.18, R6050 before 1.0.1.10, R6100 before 1.0.1.14, R6120 before 1.0.0.30, R6220 before 1.1.0.50, R6700v2 before 1.2.0.4, R6800 before 1.2.0.4, R6900v2 before 1.2.0.4, R7500 before 1.0.0.110, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.920Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051481/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2210" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.18, R6050 before 1.0.1.10, R6100 before 1.0.1.14, R6120 before 1.0.0.30, R6220 before 1.1.0.50, R6700v2 before 1.2.0.4, R6800 before 1.2.0.4, R6900v2 before 1.2.0.4, R7500 before 1.0.0.110, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T15:42:38", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051481/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2210" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18764", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.18, R6050 before 1.0.1.10, R6100 before 1.0.1.14, R6120 before 1.0.0.30, R6220 before 1.1.0.50, R6700v2 before 1.2.0.4, R6800 before 1.2.0.4, R6900v2 before 1.2.0.4, R7500 before 1.0.0.110, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051481/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2210", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051481/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2210" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18764", "datePublished": "2020-04-22T15:42:38", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.920Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21176
Vulnerability from cvelistv5
Published
2020-04-27 19:40
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.114Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055182/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2623" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T19:40:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055182/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2623" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21176", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055182/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2623", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055182/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2623" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21176", "datePublished": "2020-04-27T19:40:53", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.114Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18769
Vulnerability from cvelistv5
Published
2020-04-22 14:54
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX6200v2 before 1.0.1.50, EX7000 before 1.0.0.56, JR6150 before 1.0.1.18, R6050 before 1.0.1.10J, R6100 before 1.0.1.16, R6150 before 1.0.1.10, R6220 before 1.1.0.50, R6250 before 1.0.4.12, R6300v2 before 1.0.4.12, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.26, R6700v2 before 1.2.0.4, R6800 before 1.0.1.10, R6900 before 1.0.1.26, R6900P before 1.0.0.58, R6900v2 before 1.2.0.4, R7000 before 1.0.9.6, R7000P before 1.0.0.58, R7100LG before 1.0.0.32, R7300 before 1.0.0.54, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.40, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR3500Lv2 before 1.2.0.44.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.224Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051474/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0122" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX6200v2 before 1.0.1.50, EX7000 before 1.0.0.56, JR6150 before 1.0.1.18, R6050 before 1.0.1.10J, R6100 before 1.0.1.16, R6150 before 1.0.1.10, R6220 before 1.1.0.50, R6250 before 1.0.4.12, R6300v2 before 1.0.4.12, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.26, R6700v2 before 1.2.0.4, R6800 before 1.0.1.10, R6900 before 1.0.1.26, R6900P before 1.0.0.58, R6900v2 before 1.2.0.4, R7000 before 1.0.9.6, R7000P before 1.0.0.58, R7100LG before 1.0.0.32, R7300 before 1.0.0.54, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.40, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR3500Lv2 before 1.2.0.44." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:P/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:54:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051474/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0122" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18769", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX6200v2 before 1.0.1.50, EX7000 before 1.0.0.56, JR6150 before 1.0.1.18, R6050 before 1.0.1.10J, R6100 before 1.0.1.16, R6150 before 1.0.1.10, R6220 before 1.1.0.50, R6250 before 1.0.4.12, R6300v2 before 1.0.4.12, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.26, R6700v2 before 1.2.0.4, R6800 before 1.0.1.10, R6900 before 1.0.1.26, R6900P before 1.0.0.58, R6900v2 before 1.2.0.4, R7000 before 1.0.9.6, R7000P before 1.0.0.58, R7100LG before 1.0.0.32, R7300 before 1.0.0.54, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.40, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR3500Lv2 before 1.2.0.44." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:P/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051474/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0122", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051474/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0122" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18769", "datePublished": "2020-04-22T14:54:48", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:44.224Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21195
Vulnerability from cvelistv5
Published
2020-04-28 15:01
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.451Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055162/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2600" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:01:44", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055162/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2600" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21195", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055162/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2600", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055162/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2600" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21195", "datePublished": "2020-04-28T15:01:44", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.451Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18762
Vulnerability from cvelistv5
Published
2020-04-22 15:44
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.399Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T15:44:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18762", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18762", "datePublished": "2020-04-22T15:44:39", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.399Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21149
Vulnerability from cvelistv5
Published
2020-04-27 17:08
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.0.54, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.054Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059484/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3156" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.0.54, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:08:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059484/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3156" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21149", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.0.54, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059484/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3156", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059484/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3156" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21149", "datePublished": "2020-04-27T17:08:06", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.054Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21191
Vulnerability from cvelistv5
Published
2020-04-28 14:58
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.226Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055166/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2604" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:58:14", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055166/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2604" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21191", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055166/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2604", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055166/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2604" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21191", "datePublished": "2020-04-28T14:58:14", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.226Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21220
Vulnerability from cvelistv5
Published
2020-04-28 15:46
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.346Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:46:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21220", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21220", "datePublished": "2020-04-28T15:46:27", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.346Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20754
Vulnerability from cvelistv5
Published
2020-04-16 21:07
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects DGN2200 before 1.0.0.58, DGN2200B before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.80, D6220 before 1.0.0.44, EX7000 before 1.0.0.66, EX6200 before 1.0.3.88, EX6150 before 1.0.0.42, EX7500 before 1.0.0.46, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900P before 1.4.0.10, R8000P before 1.4.0.10, R7900 before 1.0.2.16, R7000P before 1.3.1.44, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.1.44, R7000 before 1.0.9.32, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:09.110Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060628/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Modem-Routers-and-Extenders-PSV-2018-0054" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects DGN2200 before 1.0.0.58, DGN2200B before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.80, D6220 before 1.0.0.44, EX7000 before 1.0.0.66, EX6200 before 1.0.3.88, EX6150 before 1.0.0.42, EX7500 before 1.0.0.46, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900P before 1.4.0.10, R8000P before 1.4.0.10, R7900 before 1.0.2.16, R7000P before 1.3.1.44, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.1.44, R7000 before 1.0.9.32, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T21:07:26", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060628/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Modem-Routers-and-Extenders-PSV-2018-0054" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20754", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects DGN2200 before 1.0.0.58, DGN2200B before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.80, D6220 before 1.0.0.44, EX7000 before 1.0.0.66, EX6200 before 1.0.3.88, EX6150 before 1.0.0.42, EX7500 before 1.0.0.46, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900P before 1.4.0.10, R8000P before 1.4.0.10, R7900 before 1.0.2.16, R7000P before 1.3.1.44, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.1.44, R7000 before 1.0.9.32, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060628/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Modem-Routers-and-Extenders-PSV-2018-0054", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060628/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Modem-Routers-and-Extenders-PSV-2018-0054" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20754", "datePublished": "2020-04-16T21:07:26", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:09.110Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21157
Vulnerability from cvelistv5
Published
2020-04-27 17:15
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R7500v2 before 1.0.3.24, R7800 before 1.0.2.38, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.017Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059473/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-2248" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R7500v2 before 1.0.3.24, R7800 before 1.0.2.38, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:15:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059473/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-2248" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21157", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R7500v2 before 1.0.3.24, R7800 before 1.0.2.38, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059473/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-2248", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059473/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-2248" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21157", "datePublished": "2020-04-27T17:15:25", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.017Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21227
Vulnerability from cvelistv5
Published
2020-04-24 14:29
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R6400v2 before 1.0.2.34, R6700 before 1.0.1.30, R6900 before 1.0.1.30, R6900P before 1.0.0.62, R7000 before 1.0.9.12, R7000P before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.584Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-0737" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R6400v2 before 1.0.2.34, R6700 before 1.0.1.30, R6900 before 1.0.1.30, R6900P before 1.0.0.62, R7000 before 1.0.9.12, R7000P before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:29:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-0737" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21227", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R6400v2 before 1.0.2.34, R6700 before 1.0.1.30, R6900 before 1.0.1.30, R6900P before 1.0.0.62, R7000 before 1.0.9.12, R7000P before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-0737", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-0737" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21227", "datePublished": "2020-04-24T14:29:40", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.584Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21147
Vulnerability from cvelistv5
Published
2020-04-21 21:06
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.926Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059486/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3158" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-21T21:06:11", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059486/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3158" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21147", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059486/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3158", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059486/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3158" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21147", "datePublished": "2020-04-21T21:06:11", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.926Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21145
Vulnerability from cvelistv5
Published
2020-04-21 21:03
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.320Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059488/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3160" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-21T21:03:08", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059488/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3160" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21145", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059488/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3160", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059488/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3160" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21145", "datePublished": "2020-04-21T21:03:08", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.320Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21114
Vulnerability from cvelistv5
Published
2020-04-22 14:43
Modified
2024-08-05 12:19
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:19:27.653Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-12-07T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:43:55", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21114", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21114", "datePublished": "2020-04-22T14:43:55", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:19:27.653Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21155
Vulnerability from cvelistv5
Published
2020-04-27 17:12
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.52, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.4.2, R9000 before 1.0.3.16, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.950Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Gateways-and-Routers-PSV-2017-3101" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.52, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.4.2, R9000 before 1.0.3.16, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:12:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Gateways-and-Routers-PSV-2017-3101" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21155", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.52, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.4.2, R9000 before 1.0.3.16, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Gateways-and-Routers-PSV-2017-3101", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Gateways-and-Routers-PSV-2017-3101" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21155", "datePublished": "2020-04-27T17:12:46", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.950Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18706
Vulnerability from cvelistv5
Published
2020-04-24 14:01
Modified
2024-08-05 21:28
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R6100 before 1.0.1.20, R7500 before 1.0.0.118, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:28:55.948Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R6100 before 1.0.1.20, R7500 before 1.0.0.118, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:01:32", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18706", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R6100 before 1.0.1.20, R7500 before 1.0.0.118, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18706", "datePublished": "2020-04-24T14:01:32", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:28:55.948Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21135
Vulnerability from cvelistv5
Published
2020-04-23 20:02
Modified
2024-08-05 12:19
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6700 before 1.0.1.48, R7500 before 1.0.0.124, R7800 before 1.0.2.58, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5-R2000 before 1.0.0.68.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:19:27.669Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060225/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3165" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-09-26T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6700 before 1.0.1.48, R7500 before 1.0.0.124, R7800 before 1.0.2.58, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5-R2000 before 1.0.0.68." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T20:02:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060225/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3165" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21135", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6700 before 1.0.1.48, R7500 before 1.0.0.124, R7800 before 1.0.2.58, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5-R2000 before 1.0.0.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060225/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3165", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060225/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3165" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21135", "datePublished": "2020-04-23T20:02:40", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:19:27.669Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21166
Vulnerability from cvelistv5
Published
2020-04-23 21:31
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.508Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-03-02T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T21:31:08", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21166", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21166", "datePublished": "2020-04-23T21:31:08", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.508Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21192
Vulnerability from cvelistv5
Published
2020-04-28 14:58
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.351Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055165/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2603" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:58:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055165/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2603" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21192", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055165/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2603", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055165/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2603" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21192", "datePublished": "2020-04-28T14:58:48", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.351Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20755
Vulnerability from cvelistv5
Published
2020-04-16 21:08
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6220 before 1.0.0.46, D6400 before 1.0.0.80, D7000v2 before 1.0.0.51, D8500 before 1.0.3.42, DGN2200v1 before 1.0.0.58, DGN2200B before 1.0.0.58, JNDR3000 before 1.0.0.24, RBW30 before 2.1.4.16, R6250 before 1.0.4.26, R6300v2 before 1.0.4.28, R6400 before 1.0.1.42, R6400v2 before 1.0.2.56, R6700 before 1.0.1.46, R6900 before 1.0.1.46, R7000 before 1.0.9.32, R6900P before 1.3.1.44, R7100LG before 1.0.0.46, R7300DST before 1.0.0.68, R7000P before 1.3.1.44, R7900 before 1.0.2.16, R8000P before 1.4.0.10, R7900P before 1.4.0.10, R8300 before 1.0.2.122, R8500 before 1.0.2.122, R8000 before 1.0.4.18, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, WNR3500Lv2 before 1.2.0.54, WN3100RP before 1.0.0.20, and WN2500RPv2 before 1.0.1.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:09.159Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060627/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Modem-Routers-Extenders-and-Orbi-Satellites-PSV-2018-0053" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6220 before 1.0.0.46, D6400 before 1.0.0.80, D7000v2 before 1.0.0.51, D8500 before 1.0.3.42, DGN2200v1 before 1.0.0.58, DGN2200B before 1.0.0.58, JNDR3000 before 1.0.0.24, RBW30 before 2.1.4.16, R6250 before 1.0.4.26, R6300v2 before 1.0.4.28, R6400 before 1.0.1.42, R6400v2 before 1.0.2.56, R6700 before 1.0.1.46, R6900 before 1.0.1.46, R7000 before 1.0.9.32, R6900P before 1.3.1.44, R7100LG before 1.0.0.46, R7300DST before 1.0.0.68, R7000P before 1.3.1.44, R7900 before 1.0.2.16, R8000P before 1.4.0.10, R7900P before 1.4.0.10, R8300 before 1.0.2.122, R8500 before 1.0.2.122, R8000 before 1.0.4.18, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, WNR3500Lv2 before 1.2.0.54, WN3100RP before 1.0.0.20, and WN2500RPv2 before 1.0.1.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T21:08:03", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060627/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Modem-Routers-Extenders-and-Orbi-Satellites-PSV-2018-0053" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20755", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6220 before 1.0.0.46, D6400 before 1.0.0.80, D7000v2 before 1.0.0.51, D8500 before 1.0.3.42, DGN2200v1 before 1.0.0.58, DGN2200B before 1.0.0.58, JNDR3000 before 1.0.0.24, RBW30 before 2.1.4.16, R6250 before 1.0.4.26, R6300v2 before 1.0.4.28, R6400 before 1.0.1.42, R6400v2 before 1.0.2.56, R6700 before 1.0.1.46, R6900 before 1.0.1.46, R7000 before 1.0.9.32, R6900P before 1.3.1.44, R7100LG before 1.0.0.46, R7300DST before 1.0.0.68, R7000P before 1.3.1.44, R7900 before 1.0.2.16, R8000P before 1.4.0.10, R7900P before 1.4.0.10, R8300 before 1.0.2.122, R8500 before 1.0.2.122, R8000 before 1.0.4.18, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, WNR3500Lv2 before 1.2.0.54, WN3100RP before 1.0.0.20, and WN2500RPv2 before 1.0.1.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060627/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Modem-Routers-Extenders-and-Orbi-Satellites-PSV-2018-0053", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060627/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Modem-Routers-Extenders-and-Orbi-Satellites-PSV-2018-0053" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20755", "datePublished": "2020-04-16T21:08:03", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:09.159Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21151
Vulnerability from cvelistv5
Published
2020-04-22 19:57
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.897Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059482/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3154" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T19:57:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059482/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3154" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21151", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059482/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3154", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059482/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3154" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21151", "datePublished": "2020-04-22T19:57:49", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.897Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21210
Vulnerability from cvelistv5
Published
2020-04-28 15:33
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.251Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055139/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2492" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:33:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055139/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2492" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21210", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055139/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2492", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055139/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2492" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21210", "datePublished": "2020-04-28T15:33:29", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.251Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18775
Vulnerability from cvelistv5
Published
2020-04-22 14:44
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by CSRF. This affects R6100 before 1.0.1.12, R7500 before 1.0.0.108, WNDR3700v4 before 1.0.2.86, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.42.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.990Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000049553/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-and-Gateways-PSV-2017-0388" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects R6100 before 1.0.1.12, R7500 before 1.0.0.108, WNDR3700v4 before 1.0.2.86, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.42." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:44:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000049553/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-and-Gateways-PSV-2017-0388" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18775", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by CSRF. This affects R6100 before 1.0.1.12, R7500 before 1.0.0.108, WNDR3700v4 before 1.0.2.86, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.42." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049553/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-and-Gateways-PSV-2017-0388", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000049553/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-and-Gateways-PSV-2017-0388" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18775", "datePublished": "2020-04-22T14:44:20", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.990Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21203
Vulnerability from cvelistv5
Published
2020-04-28 15:11
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects R6100 before 1.0.1.20, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.233Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055146/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2589" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects R6100 before 1.0.1.20, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:11:10", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055146/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2589" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21203", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects R6100 before 1.0.1.20, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055146/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2589", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055146/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2589" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21203", "datePublished": "2020-04-28T15:11:10", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.233Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21201
Vulnerability from cvelistv5
Published
2020-04-28 15:07
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.356Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055148/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2591" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:07:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055148/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2591" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21201", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055148/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2591", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055148/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2591" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21201", "datePublished": "2020-04-28T15:07:27", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.356Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21189
Vulnerability from cvelistv5
Published
2020-04-28 14:57
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.092Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055168/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2606" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055168/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2606" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21189", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055168/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2606", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055168/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2606" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21189", "datePublished": "2020-04-28T14:57:01", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.092Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21212
Vulnerability from cvelistv5
Published
2020-04-28 15:36
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.357Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055137/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2490" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:36:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055137/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2490" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21212", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055137/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2490", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055137/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2490" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21212", "datePublished": "2020-04-28T15:36:49", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.357Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21167
Vulnerability from cvelistv5
Published
2020-04-27 17:28
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.57, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.78, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.280Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055191/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Routers-Gateways-Extenders-and-DSL-Modems-PSV-2017-3093" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.57, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.78, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:28:35", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055191/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Routers-Gateways-Extenders-and-DSL-Modems-PSV-2017-3093" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21167", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.57, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.78, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055191/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Routers-Gateways-Extenders-and-DSL-Modems-PSV-2017-3093", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055191/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Routers-Gateways-Extenders-and-DSL-Modems-PSV-2017-3093" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21167", "datePublished": "2020-04-27T17:28:35", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.280Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21173
Vulnerability from cvelistv5
Published
2020-04-27 17:39
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.274Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055185/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2627" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:39:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055185/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2627" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21173", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055185/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2627", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055185/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2627" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21173", "datePublished": "2020-04-27T17:39:46", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.274Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18748
Vulnerability from cvelistv5
Published
2020-04-23 15:30
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX6200v2 before 1.0.1.44, R6100 before 1.0.1.12, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, R7800 before 1.0.2.28, R9000 before 1.0.2.30, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:42.914Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051506/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0104" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX6200v2 before 1.0.1.44, R6100 before 1.0.1.12, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, R7800 before 1.0.2.28, R9000 before 1.0.2.30, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T15:30:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051506/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0104" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18748", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX6200v2 before 1.0.1.44, R6100 before 1.0.1.12, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, R7800 before 1.0.2.28, R9000 before 1.0.2.30, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051506/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0104", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051506/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0104" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18748", "datePublished": "2020-04-23T15:30:29", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:42.914Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21205
Vulnerability from cvelistv5
Published
2020-04-28 15:13
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.538Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055144/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2568" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:13:35", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055144/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2568" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21205", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055144/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2568", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055144/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2568" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21205", "datePublished": "2020-04-28T15:13:35", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.538Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20747
Vulnerability from cvelistv5
Published
2020-04-16 20:58
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.40, R7500v2 before 1.0.3.34, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.3.16, RAX120 before 1.0.0.74, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBK40 before 2.3.0.22, RBS40 before 2.3.0.22, SRK60 before 2.2.0.64, SRR60 before 2.2.0.64, SRS60 before 2.2.0.64, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5 before 1.0.0.66.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.827Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060962/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0032" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.40, R7500v2 before 1.0.3.34, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.3.16, RAX120 before 1.0.0.74, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBK40 before 2.3.0.22, RBS40 before 2.3.0.22, SRK60 before 2.2.0.64, SRR60 before 2.2.0.64, SRS60 before 2.2.0.64, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5 before 1.0.0.66." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T20:58:15", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060962/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0032" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20747", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.40, R7500v2 before 1.0.3.34, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.3.16, RAX120 before 1.0.0.74, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBK40 before 2.3.0.22, RBS40 before 2.3.0.22, SRK60 before 2.2.0.64, SRR60 before 2.2.0.64, SRS60 before 2.2.0.64, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5 before 1.0.0.66." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060962/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0032", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060962/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0032" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20747", "datePublished": "2020-04-16T20:58:15", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.827Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21169
Vulnerability from cvelistv5
Published
2020-04-27 17:32
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7000 before 2018-03-01, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 2018-03-01, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.177Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055189/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2913" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7000 before 2018-03-01, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 2018-03-01, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:32:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055189/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2913" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21169", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7000 before 2018-03-01, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 2018-03-01, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055189/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2913", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055189/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2913" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21169", "datePublished": "2020-04-27T17:32:01", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.177Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21208
Vulnerability from cvelistv5
Published
2020-04-28 15:30
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.694Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2516" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:30:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2516" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21208", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2516", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2516" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21208", "datePublished": "2020-04-28T15:30:56", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.694Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21111
Vulnerability from cvelistv5
Published
2020-04-22 14:23
Modified
2024-08-05 12:19
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.60, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.66.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:19:27.631Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000060440/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0115" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-12-07T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.60, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.66." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:23:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000060440/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0115" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21111", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.60, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.66." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000060440/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0115", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000060440/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0115" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21111", "datePublished": "2020-04-22T14:23:27", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:19:27.631Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18776
Vulnerability from cvelistv5
Published
2020-04-22 14:43
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D6100 before V1.0.0.55, D7000 before V1.0.1.50, D7800 before V1.0.1.24, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, R6100 before 1.0.1.12, R6220 before 1.1.0.50, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.40, WNR2000v5 before 1.0.0.42, WNR2020 before 1.1.0.40, and WNR2050 before 1.1.0.40.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.206Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000049552/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-Gateways-PSV-2017-0387" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects D6100 before V1.0.0.55, D7000 before V1.0.1.50, D7800 before V1.0.1.24, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, R6100 before 1.0.1.12, R6220 before 1.1.0.50, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.40, WNR2000v5 before 1.0.0.42, WNR2020 before 1.1.0.40, and WNR2050 before 1.1.0.40." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:43:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000049552/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-Gateways-PSV-2017-0387" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18776", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects D6100 before V1.0.0.55, D7000 before V1.0.1.50, D7800 before V1.0.1.24, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, R6100 before 1.0.1.12, R6220 before 1.1.0.50, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.40, WNR2000v5 before 1.0.0.42, WNR2020 before 1.1.0.40, and WNR2050 before 1.1.0.40." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049552/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-Gateways-PSV-2017-0387", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000049552/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-Gateways-PSV-2017-0387" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18776", "datePublished": "2020-04-22T14:43:25", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:44.206Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21211
Vulnerability from cvelistv5
Published
2020-04-28 15:34
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.311Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055138/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2491" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:34:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055138/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2491" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21211", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055138/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2491", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055138/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2491" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21211", "datePublished": "2020-04-28T15:34:28", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.311Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18703
Vulnerability from cvelistv5
Published
2020-04-24 14:08
Modified
2024-08-05 21:28
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by CSRF. This affects D1500 before 1.0.0.25, D500 before 1.0.0.25, D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, EX6100v2 before 1.0.1.60, EX6150v2 before 1.0.1.60, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.16, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.18, R6020 before 1.0.0.26, R6050 before 1.0.1.16, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6220 before 1.1.0.60, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3700v5 before 1.1.0.48, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.46, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:28:56.070Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053199/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0736" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects D1500 before 1.0.0.25, D500 before 1.0.0.25, D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, EX6100v2 before 1.0.1.60, EX6150v2 before 1.0.1.60, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.16, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.18, R6020 before 1.0.0.26, R6050 before 1.0.1.16, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6220 before 1.1.0.60, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3700v5 before 1.1.0.48, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.46, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:08:11", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053199/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0736" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18703", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by CSRF. This affects D1500 before 1.0.0.25, D500 before 1.0.0.25, D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, EX6100v2 before 1.0.1.60, EX6150v2 before 1.0.1.60, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.16, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.18, R6020 before 1.0.0.26, R6050 before 1.0.1.16, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6220 before 1.1.0.60, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3700v5 before 1.1.0.48, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.46, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053199/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0736", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053199/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0736" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18703", "datePublished": "2020-04-24T14:08:11", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:28:56.070Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18785
Vulnerability from cvelistv5
Published
2020-04-22 14:23
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by XSS. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6100v2 before 1.0.1.54, EX6150v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6020 before 1.0.0.26, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6800 before 1.2.0.12, R6900v2 before 1.2.0.12, R6700v2 before 1.2.0.12, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.18, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R7900P before 1.1.5.14, R8000 before 1.0.4.4, R8000P before 1.1.5.14, R8500 before 1.0.2.110, R8300 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.8, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.42, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.208Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000049534/Security-Advisory-for-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2950" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by XSS. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6100v2 before 1.0.1.54, EX6150v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6020 before 1.0.0.26, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6800 before 1.2.0.12, R6900v2 before 1.2.0.12, R6700v2 before 1.2.0.12, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.18, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R7900P before 1.1.5.14, R8000 before 1.0.4.4, R8000P before 1.1.5.14, R8500 before 1.0.2.110, R8300 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.8, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.42, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:L/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:23:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000049534/Security-Advisory-for-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2950" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18785", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by XSS. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6100v2 before 1.0.1.54, EX6150v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6020 before 1.0.0.26, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6800 before 1.2.0.12, R6900v2 before 1.2.0.12, R6700v2 before 1.2.0.12, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.18, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R7900P before 1.1.5.14, R8000 before 1.0.4.4, R8000P before 1.1.5.14, R8500 before 1.0.2.110, R8300 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.8, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.42, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:L/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049534/Security-Advisory-for-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2950", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000049534/Security-Advisory-for-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2950" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18785", "datePublished": "2020-04-22T14:23:04", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:44.208Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18853
Vulnerability from cvelistv5
Published
2020-04-29 13:10
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by password recovery and file access. This affects D8500 1.0.3.27 and earlier, DGN2200v4 1.0.0.82 and earlier, R6300v2 1.0.4.06 and earlier, R6400 1.0.1.20 and earlier, R6400v2 1.0.2.18 and earlier, R6700 1.0.1.22 and earlier, R6900 1.0.1.20 and earlier, R7000 1.0.7.10 and earlier, R7000P 1.0.0.58 and earlier, R7100LG 1.0.0.28 and earlier, R7300DST 1.0.0.52 and earlier, R7900 1.0.1.12 and earlier, R8000 1.0.3.46 and earlier, R8300 1.0.2.86 and earlier, R8500 1.0.2.86 and earlier, WNDR3400v3 1.0.1.8 and earlier, and WNDR4500v2 1.0.0.62 and earlier.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.295Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000045848/Security-Advisory-for-Password-Recovery-and-File-Access-on-Some-Routers-and-Modem-Routers-PSV-2017-0677" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-09-29T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password recovery and file access. This affects D8500 1.0.3.27 and earlier, DGN2200v4 1.0.0.82 and earlier, R6300v2 1.0.4.06 and earlier, R6400 1.0.1.20 and earlier, R6400v2 1.0.2.18 and earlier, R6700 1.0.1.22 and earlier, R6900 1.0.1.20 and earlier, R7000 1.0.7.10 and earlier, R7000P 1.0.0.58 and earlier, R7100LG 1.0.0.28 and earlier, R7300DST 1.0.0.52 and earlier, R7900 1.0.1.12 and earlier, R8000 1.0.3.46 and earlier, R8300 1.0.2.86 and earlier, R8500 1.0.2.86 and earlier, WNDR3400v3 1.0.1.8 and earlier, and WNDR4500v2 1.0.0.62 and earlier." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-29T13:10:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000045848/Security-Advisory-for-Password-Recovery-and-File-Access-on-Some-Routers-and-Modem-Routers-PSV-2017-0677" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18853", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by password recovery and file access. This affects D8500 1.0.3.27 and earlier, DGN2200v4 1.0.0.82 and earlier, R6300v2 1.0.4.06 and earlier, R6400 1.0.1.20 and earlier, R6400v2 1.0.2.18 and earlier, R6700 1.0.1.22 and earlier, R6900 1.0.1.20 and earlier, R7000 1.0.7.10 and earlier, R7000P 1.0.0.58 and earlier, R7100LG 1.0.0.28 and earlier, R7300DST 1.0.0.52 and earlier, R7900 1.0.1.12 and earlier, R8000 1.0.3.46 and earlier, R8300 1.0.2.86 and earlier, R8500 1.0.2.86 and earlier, WNDR3400v3 1.0.1.8 and earlier, and WNDR4500v2 1.0.0.62 and earlier." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000045848/Security-Advisory-for-Password-Recovery-and-File-Access-on-Some-Routers-and-Modem-Routers-PSV-2017-0677", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000045848/Security-Advisory-for-Password-Recovery-and-File-Access-on-Some-Routers-and-Modem-Routers-PSV-2017-0677" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18853", "datePublished": "2020-04-29T13:10:31", "dateReserved": "2020-04-27T00:00:00", "dateUpdated": "2024-08-05T21:37:44.295Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20722
Vulnerability from cvelistv5
Published
2020-04-16 17:04
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.722Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061206/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0148" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T17:04:08", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061206/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0148" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20722", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061206/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0148", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061206/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0148" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20722", "datePublished": "2020-04-16T17:04:08", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.722Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21186
Vulnerability from cvelistv5
Published
2020-04-28 14:54
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.285Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055172/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2609" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:54:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055172/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2609" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21186", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055172/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2609", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055172/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2609" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21186", "datePublished": "2020-04-28T14:54:13", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.285Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21222
Vulnerability from cvelistv5
Published
2020-04-28 16:24
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.447Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-02-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T16:24:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21222", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21222", "datePublished": "2020-04-28T16:24:51", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.447Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21223
Vulnerability from cvelistv5
Published
2020-04-28 16:26
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.356Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-02-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T16:26:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21223", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21223", "datePublished": "2020-04-28T16:26:40", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.356Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20724
Vulnerability from cvelistv5
Published
2020-04-16 19:00
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, D7800 before 1.0.1.44, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.669Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061204/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0144" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, D7800 before 1.0.1.44, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:00:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061204/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0144" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20724", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, D7800 before 1.0.1.44, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061204/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0144", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061204/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0144" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20724", "datePublished": "2020-04-16T19:00:20", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.669Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21231
Vulnerability from cvelistv5
Published
2020-04-24 14:22
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1.78, JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055103/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0102" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1.78, JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:22:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055103/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0102" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21231", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1.78, JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055103/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0102", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055103/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0102" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21231", "datePublished": "2020-04-24T14:22:48", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.563Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21152
Vulnerability from cvelistv5
Published
2020-04-27 17:09
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.510Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059481/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3152" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:09:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059481/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3152" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21152", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059481/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3152", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059481/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3152" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21152", "datePublished": "2020-04-27T17:09:39", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.510Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21198
Vulnerability from cvelistv5
Published
2020-04-28 15:04
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.2.0.44, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.393Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055151/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2594" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.2.0.44, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:04:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055151/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2594" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21198", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.2.0.44, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055151/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2594", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055151/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2594" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21198", "datePublished": "2020-04-28T15:04:12", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.393Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-5521
Vulnerability from cvelistv5
Published
2017-01-17 09:22
Modified
2024-08-05 15:04
Severity ?
EPSS score ?
Summary
An issue was discovered on NETGEAR R8500, R8300, R7000, R6400, R7300, R7100LG, R6300v2, WNDR3400v3, WNR3500Lv2, R6250, R6700, R6900, and R8000 devices. They are prone to password disclosure via simple crafted requests to the web management server. The bug is exploitable remotely if the remote management option is set, and can also be exploited given access to the router over LAN or WLAN. When trying to access the web panel, a user is asked to authenticate; if the authentication is canceled and password recovery is not enabled, the user is redirected to a page that exposes a password recovery token. If a user supplies the correct token to the page /passwordrecovered.cgi?id=TOKEN (and password recovery is not enabled), they will receive the admin password for the router. If password recovery is set the exploit will fail, as it will ask the user for the recovery questions that were previously set when enabling that feature. This is persistent (even after disabling the recovery option, the exploit will fail) because the router will ask for the security questions.
References
▼ | URL | Tags |
---|---|---|
https://www.exploit-db.com/exploits/41205/ | exploit, x_refsource_EXPLOIT-DB | |
http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability | x_refsource_CONFIRM | |
http://www.securityfocus.com/bid/95457 | vdb-entry, x_refsource_BID |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T15:04:14.997Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "41205", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "https://www.exploit-db.com/exploits/41205/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability" }, { "name": "95457", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/95457" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-01-17T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on NETGEAR R8500, R8300, R7000, R6400, R7300, R7100LG, R6300v2, WNDR3400v3, WNR3500Lv2, R6250, R6700, R6900, and R8000 devices. They are prone to password disclosure via simple crafted requests to the web management server. The bug is exploitable remotely if the remote management option is set, and can also be exploited given access to the router over LAN or WLAN. When trying to access the web panel, a user is asked to authenticate; if the authentication is canceled and password recovery is not enabled, the user is redirected to a page that exposes a password recovery token. If a user supplies the correct token to the page /passwordrecovered.cgi?id=TOKEN (and password recovery is not enabled), they will receive the admin password for the router. If password recovery is set the exploit will fail, as it will ask the user for the recovery questions that were previously set when enabling that feature. This is persistent (even after disabling the recovery option, the exploit will fail) because the router will ask for the security questions." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-31T09:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "name": "41205", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "https://www.exploit-db.com/exploits/41205/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability" }, { "name": "95457", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/95457" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-5521", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on NETGEAR R8500, R8300, R7000, R6400, R7300, R7100LG, R6300v2, WNDR3400v3, WNR3500Lv2, R6250, R6700, R6900, and R8000 devices. They are prone to password disclosure via simple crafted requests to the web management server. The bug is exploitable remotely if the remote management option is set, and can also be exploited given access to the router over LAN or WLAN. When trying to access the web panel, a user is asked to authenticate; if the authentication is canceled and password recovery is not enabled, the user is redirected to a page that exposes a password recovery token. If a user supplies the correct token to the page /passwordrecovered.cgi?id=TOKEN (and password recovery is not enabled), they will receive the admin password for the router. If password recovery is set the exploit will fail, as it will ask the user for the recovery questions that were previously set when enabling that feature. This is persistent (even after disabling the recovery option, the exploit will fail) because the router will ask for the security questions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "41205", "refsource": "EXPLOIT-DB", "url": "https://www.exploit-db.com/exploits/41205/" }, { "name": "http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability", "refsource": "CONFIRM", "url": "http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability" }, { "name": "95457", "refsource": "BID", "url": "http://www.securityfocus.com/bid/95457" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-5521", "datePublished": "2017-01-17T09:22:00", "dateReserved": "2017-01-17T00:00:00", "dateUpdated": "2024-08-05T15:04:14.997Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21153
Vulnerability from cvelistv5
Published
2020-04-27 17:10
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.62, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.554Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059480/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Gateways-Routers-and-Extenders-PSV-2017-3136" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.62, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T17:10:47", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059480/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Gateways-Routers-and-Extenders-PSV-2017-3136" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21153", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.62, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059480/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Gateways-Routers-and-Extenders-PSV-2017-3136", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059480/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Gateways-Routers-and-Extenders-PSV-2017-3136" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21153", "datePublished": "2020-04-27T17:10:47", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.554Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21150
Vulnerability from cvelistv5
Published
2020-04-22 19:55
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.919Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T19:55:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21150", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21150", "datePublished": "2020-04-22T19:55:42", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.919Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20723
Vulnerability from cvelistv5
Published
2020-04-16 17:05
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.521Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T17:05:44", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20723", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20723", "datePublished": "2020-04-16T17:05:44", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.521Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18778
Vulnerability from cvelistv5
Published
2020-04-22 14:41
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D7000 before 1.0.1.52, D7000v2 before 1.0.0.38, D7800 before 1.0.1.24, D8500 before 1.0.3.29, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7100LG before 1.0.0.32, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300v1 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.252Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000049543/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2957" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D7000 before 1.0.1.52, D7000v2 before 1.0.0.38, D7800 before 1.0.1.24, D8500 before 1.0.3.29, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7100LG before 1.0.0.32, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300v1 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T14:41:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000049543/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2957" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18778", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D7000 before 1.0.1.52, D7000v2 before 1.0.0.38, D7800 before 1.0.1.24, D8500 before 1.0.3.29, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7100LG before 1.0.0.32, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300v1 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049543/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2957", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000049543/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2957" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18778", "datePublished": "2020-04-22T14:41:00", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:44.252Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20736
Vulnerability from cvelistv5
Published
2020-04-16 19:14
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6000 before 1.0.0.72, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.655Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061190/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0133" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6000 before 1.0.0.72, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:14:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061190/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0133" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20736", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6000 before 1.0.0.72, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061190/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0133", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061190/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0133" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20736", "datePublished": "2020-04-16T19:14:48", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.655Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18751
Vulnerability from cvelistv5
Published
2020-04-23 15:21
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.858Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051503/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2517" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T15:21:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051503/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2517" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18751", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051503/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2517", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051503/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2517" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18751", "datePublished": "2020-04-23T15:21:56", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.858Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21218
Vulnerability from cvelistv5
Published
2020-04-28 15:43
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.056Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:43:54", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21218", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21218", "datePublished": "2020-04-28T15:43:54", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.056Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18712
Vulnerability from cvelistv5
Published
2020-04-24 13:35
Modified
2024-08-05 21:28
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:28:56.072Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000053136/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0127" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T13:35:16", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000053136/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0127" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18712", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000053136/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0127", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000053136/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0127" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18712", "datePublished": "2020-04-24T13:35:16", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:28:56.072Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18788
Vulnerability from cvelistv5
Published
2020-04-22 13:42
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6150v2 before 1.0.1.54, EX6100v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.18, R6900P before 1.3.0.8, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R8000 before 1.0.4.4_1.1.42, R7900P before 1.1.5.14, R8000P before 1.1.5.14, R8300 before 1.0.2.110, R8500 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.14, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:43.975Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000049527/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2947" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6150v2 before 1.0.1.54, EX6100v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.18, R6900P before 1.3.0.8, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R8000 before 1.0.4.4_1.1.42, R7900P before 1.1.5.14, R8000P before 1.1.5.14, R8300 before 1.0.2.110, R8500 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.14, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-22T13:42:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000049527/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2947" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18788", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6150v2 before 1.0.1.54, EX6100v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.18, R6900P before 1.3.0.8, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R8000 before 1.0.4.4_1.1.42, R7900P before 1.1.5.14, R8000P before 1.1.5.14, R8300 before 1.0.2.110, R8500 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.14, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000049527/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2947", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000049527/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2947" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18788", "datePublished": "2020-04-22T13:42:30", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:43.975Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21230
Vulnerability from cvelistv5
Published
2020-04-24 14:26
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1., JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.309Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055104/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0117" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1., JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:26:58", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055104/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0117" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21230", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1., JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055104/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0117", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055104/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0117" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21230", "datePublished": "2020-04-24T14:26:58", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.309Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20730
Vulnerability from cvelistv5
Published
2020-04-16 19:09
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by SQL injection. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6200 before 1.1.00.28, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DC112A before 1.0.0.40, EX8000 before 1.0.0.118, JR6150 before 1.0.1.18, R6050 before 1.0.1.18, R6220 before 1.1.0.66, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900v2 before 1.2.0.16, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500 before 1.0.0.118, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.6, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:08.529Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061197/Security-Advisory-for-SQL-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3056" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by SQL injection. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6200 before 1.1.00.28, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DC112A before 1.0.0.40, EX8000 before 1.0.0.118, JR6150 before 1.0.1.18, R6050 before 1.0.1.18, R6220 before 1.1.0.66, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900v2 before 1.2.0.16, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500 before 1.0.0.118, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.6, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:N/A:N/C:H/I:L/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T19:09:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061197/Security-Advisory-for-SQL-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3056" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20730", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by SQL injection. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6200 before 1.1.00.28, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DC112A before 1.0.0.40, EX8000 before 1.0.0.118, JR6150 before 1.0.1.18, R6050 before 1.0.1.18, R6220 before 1.1.0.66, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900v2 before 1.2.0.16, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500 before 1.0.0.118, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.6, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:N/A:N/C:H/I:L/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061197/Security-Advisory-for-SQL-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3056", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061197/Security-Advisory-for-SQL-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3056" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20730", "datePublished": "2020-04-16T19:09:31", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:08.529Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21142
Vulnerability from cvelistv5
Published
2020-04-23 20:13
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:37.306Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-06-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T20:13:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21142", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21142", "datePublished": "2020-04-23T20:13:41", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:37.306Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21181
Vulnerability from cvelistv5
Published
2020-04-28 12:47
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.308Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T12:47:24", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21181", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21181", "datePublished": "2020-04-28T12:47:24", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.308Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20689
Vulnerability from cvelistv5
Published
2020-04-16 14:24
Modified
2024-08-05 02:46
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:46:10.451Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0132" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T14:24:35", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0132" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20689", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0132", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0132" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20689", "datePublished": "2020-04-16T14:24:35", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:46:10.451Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21188
Vulnerability from cvelistv5
Published
2020-04-28 14:56
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.983Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055169/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2607" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T14:56:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055169/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2607" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21188", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055169/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2607", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055169/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2607" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21188", "datePublished": "2020-04-28T14:56:01", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.983Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21229
Vulnerability from cvelistv5
Published
2020-04-24 14:27
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R7500v2 before 1.0.3.20, R7800 before 1.0.2.38, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:39.306Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055105/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0124" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R7500v2 before 1.0.3.20, R7800 before 1.0.2.38, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:H/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-24T14:27:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055105/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0124" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21229", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R7500v2 before 1.0.3.20, R7800 before 1.0.2.38, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:H/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055105/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0124", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055105/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0124" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21229", "datePublished": "2020-04-24T14:27:52", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:39.306Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18738
Vulnerability from cvelistv5
Published
2020-04-23 16:04
Modified
2024-08-05 21:37
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects EX6150v2 before 1.0.1.54, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.22, R6900 before 1.0.1.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R6900P before 1.2.0.22, R7100LG before 1.0.0.32, R7300DST before 1.0.0.54, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.106, R8500 before 1.0.2.106, R6100 before 1.0.1.16, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.182Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000051517/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Extenders-PSV-2017-0706" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects EX6150v2 before 1.0.1.54, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.22, R6900 before 1.0.1.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R6900P before 1.2.0.22, R7100LG before 1.0.0.32, R7300DST before 1.0.0.54, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.106, R8500 before 1.0.2.106, R6100 before 1.0.1.16, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-23T16:04:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000051517/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Extenders-PSV-2017-0706" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18738", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects EX6150v2 before 1.0.1.54, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.22, R6900 before 1.0.1.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R6900P before 1.2.0.22, R7100LG before 1.0.0.32, R7300DST before 1.0.0.54, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.106, R8500 before 1.0.2.106, R6100 before 1.0.1.16, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000051517/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Extenders-PSV-2017-0706", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000051517/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Extenders-PSV-2017-0706" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18738", "datePublished": "2020-04-23T16:04:20", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T21:37:44.182Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21224
Vulnerability from cvelistv5
Published
2020-04-28 16:28
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.997Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-02-22T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T16:28:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21224", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21224", "datePublished": "2020-04-28T16:28:05", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.997Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-21180
Vulnerability from cvelistv5
Published
2020-04-27 20:10
Modified
2024-08-05 12:26
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:26:38.604Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000055178/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2619" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-27T20:10:48", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000055178/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2619" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-21180", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000055178/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2619", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000055178/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2619" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-21180", "datePublished": "2020-04-27T20:10:48", "dateReserved": "2020-04-20T00:00:00", "dateUpdated": "2024-08-05T12:26:38.604Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2020-04-21 21:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Ciertos dispositivos NETGEAR se ven afectados por la denegaci\u00f3n de servicio. Esto afecta a R6100 en versiones anteriores a la 1.0.1.22, R7500 en versiones anteriores a la 1.0.0.122, R7800 en versiones anteriores a la 1.0.2.42, R8900 en versiones anteriores a la 1.0.3.10, R9000 en versiones anteriores a la 1.0.3.10, WNDR3700v4 en versiones anteriores a la 1.0.2.96, WNDR4300 en versiones anteriores a la 1.0.2.98, WNDR4300v2 en versiones anteriores a la 1.0.0.54, WNDR4500v3 en versiones anteriores a la 1.0.0.54 y WNR2000v5 en versiones anteriores a la 1.0.0.64." } ], "id": "CVE-2018-21141", "lastModified": "2024-11-21T04:03:00.047", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 2.7, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-21T21:15:12.740", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059492/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3168" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, D7800 versiones anteriores a 1.0.1.34, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0. 2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21190", "lastModified": "2024-11-21T04:03:07.983", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.597", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055167/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2605" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055167/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2605" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CD898239-AEDF-4CA5-A5AE-946584971C8F", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "911BC502-92BB-4E99-9BC8-1972C8E727ED", "versionEndExcluding": "1.0.1.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048", "versionEndExcluding": "1.0.1.180", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9D54BE2-47EB-48F1-A6D0-FB0A2F5094C4", "versionEndExcluding": "1.0.2.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1BC2531A-35BD-4C38-BDB5-22E11FCBB30C", "versionEndExcluding": "2.2.1.210", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCC347EB-699E-4626-A944-2D378101DDCF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A195DB28-E5A6-43B5-811A-138BDE4C79EF", "versionEndExcluding": "2.2.1.210", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "55E6F589-04DA-431C-9E03-BA2A59BB0E4A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A23A7EC0-83D8-449E-8FEE-256D08F995F1", "versionEndExcluding": "2.2.1.210", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFB01247-A20F-41CA-8718-E8E60E7F14B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C9BEC80-8534-4485-9762-612242EDC0BE", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, EX2700 before 1.0.1.52, EX6200v2 before 1.0.1.74, EX8000 before 1.0.1.180, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, SRK60 before 2.2.1.210, SRR60 before 2.2.1.210, SRS60 before 2.2.1.210, WN2000RPTv3 before 1.0.1.34, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, and WNDR4500v3 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D7800 versiones anteriores a 1.0.1.44, EX2700 versiones anteriores a 1.0.1.52, EX6200v2 versiones anteriores a 1.0.1.74, EX8000 versiones anteriores a 1.0.1. 180, R7500v2 versiones anteriores a 1.0.3.38, R7800 versiones anteriores a 1.0.2.58, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2. 3.0.32, RBS50 versiones anteriores a 2.3.0.32, RBS40 versiones anteriores a 2.3.0.28, SRK60 versiones anteriores a 2.2.1.210, SRR60 versiones anteriores a 2.2.1.210, SRS60 versiones anteriores a 2.2.1.210, WN2000RPTv3 versiones anteriores a 1.0. 1.34, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR4300v2 versiones anteriores a 1.0.0.58, y WNDR4500v3 versiones anteriores a 1.0.0.58." } ], "id": "CVE-2019-20717", "lastModified": "2024-11-21T04:39:10.313", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:24.930", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061211/Security-Advisory-for-Denial-of-Service-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2018-0225" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR4300v2 versiones anteriores a 1.0.0.54 y WNDR4500v3 versiones anteriores a 1.0.0.54." } ], "id": "CVE-2018-21152", "lastModified": "2024-11-21T04:03:01.707", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.170", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059481/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3152" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059481/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3152" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r900_firmware | * | |
netgear | r900 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3ABBD2E7-85AA-4EDA-908C-410D44DD74DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r900:-:*:*:*:*:*:*:*", "matchCriteriaId": "F75EB581-AACC-401D-ACA7-0BCA73D12621", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, EX2700 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WN2000RPTv3 versiones anteriores a 1. 0.1.20, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21205", "lastModified": "2024-11-21T04:03:10.330", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.497", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055144/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2568" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055144/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2568" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2. 52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21186", "lastModified": "2024-11-21T04:03:07.333", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.363", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055172/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2609" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055172/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2609" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2. 40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, y WNDR4500v3 versiones anteriores a 1.0.0.54." } ], "id": "CVE-2018-21202", "lastModified": "2024-11-21T04:03:09.880", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.327", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055147/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2590" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055147/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2590" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-29 14:15
Modified
2024-11-21 03:21
Severity ?
Summary
Certain NETGEAR devices are affected by password recovery and file access. This affects D8500 1.0.3.27 and earlier, DGN2200v4 1.0.0.82 and earlier, R6300v2 1.0.4.06 and earlier, R6400 1.0.1.20 and earlier, R6400v2 1.0.2.18 and earlier, R6700 1.0.1.22 and earlier, R6900 1.0.1.20 and earlier, R7000 1.0.7.10 and earlier, R7000P 1.0.0.58 and earlier, R7100LG 1.0.0.28 and earlier, R7300DST 1.0.0.52 and earlier, R7900 1.0.1.12 and earlier, R8000 1.0.3.46 and earlier, R8300 1.0.2.86 and earlier, R8500 1.0.2.86 and earlier, WNDR3400v3 1.0.1.8 and earlier, and WNDR4500v2 1.0.0.62 and earlier.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d8500_firmware | * | |
netgear | d8500 | - | |
netgear | dgn2200_firmware | * | |
netgear | dgn2200 | v4 | |
netgear | r6300_firmware | * | |
netgear | r6300 | v2 | |
netgear | r6400_firmware | * | |
netgear | r6400 | - | |
netgear | r6400_firmware | * | |
netgear | r6400 | v2 | |
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r7100lg_firmware | * | |
netgear | r7100lg | - | |
netgear | r7300dst_firmware | * | |
netgear | r7300dst | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8300_firmware | * | |
netgear | r8300 | - | |
netgear | r8500_firmware | * | |
netgear | r8500 | - | |
netgear | wndr3400_firmware | * | |
netgear | wndr3400 | v3 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3CABB269-2967-49F4-B8E8-66825747EB97", "versionEndIncluding": "1.0.3.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4B809BE-307B-4309-A333-DB5E7722F8A2", "versionEndIncluding": "1.0.0.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38C75CA-2B68-4D85-B1FC-3CF9281D5D1B", "versionEndIncluding": "1.0.4.06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "11AA26A0-5DAA-46B6-B7B8-E34DB439ABDC", "versionEndIncluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C9D4FA9-A99B-4931-B89E-247EB64567AA", "versionEndIncluding": "1.0.2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3AC00FC1-A271-477A-B22C-4C58D0915B28", "versionEndIncluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A231747C-B62D-445E-8A1E-B233FC057A14", "versionEndIncluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B34F561-E662-498D-824A-DD4358334396", "versionEndIncluding": "1.0.7.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B773066-41DF-4EFF-A063-20063C49856D", "versionEndIncluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4B29972-7657-41E4-AB1D-F2183479927E", "versionEndIncluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "83A30682-9882-46FA-8690-C33B9006F54C", "versionEndIncluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5ABC8087-5B43-4C05-B210-3D5519D76B7B", "versionEndIncluding": "1.0.1.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C59B5FF-EB54-4CFE-AF59-FCD090847F00", "versionEndIncluding": "1.0.3.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C51DBE7B-AC3B-4BB3-91D9-7AA679676B49", "versionEndIncluding": "1.0.2.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5DEA7DEA-328B-40B7-865E-88797DEB3965", "versionEndIncluding": "1.0.2.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F271857E-66B1-4AC3-8C8B-07A9C96BB066", "versionEndIncluding": "1.0.1.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FFA07BD5-8D6F-4F1D-A227-BDD67DD8D152", "versionEndIncluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password recovery and file access. This affects D8500 1.0.3.27 and earlier, DGN2200v4 1.0.0.82 and earlier, R6300v2 1.0.4.06 and earlier, R6400 1.0.1.20 and earlier, R6400v2 1.0.2.18 and earlier, R6700 1.0.1.22 and earlier, R6900 1.0.1.20 and earlier, R7000 1.0.7.10 and earlier, R7000P 1.0.0.58 and earlier, R7100LG 1.0.0.28 and earlier, R7300DST 1.0.0.52 and earlier, R7900 1.0.1.12 and earlier, R8000 1.0.3.46 and earlier, R8300 1.0.2.86 and earlier, R8500 1.0.2.86 and earlier, WNDR3400v3 1.0.1.8 and earlier, and WNDR4500v2 1.0.0.62 and earlier." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una recuperaci\u00f3n de la contrase\u00f1a y el acceso a los archivos. Esto afecta a D8500 versiones 1.0.3.27 y anteriores, DGN2200v4 versiones 1.0.0.82 y anteriores, R6300v2 versiones 1.0.4.06 y anteriores, R6400 versiones 1.0.1.20 y anteriores, R6400v2 versiones 1.0.2.18 y anteriores, R6700 versiones 1.0.1.22 y anteriores, R6900 versiones 1.0.1.20 y anteriores, R7000 versiones 1.0.7.10 y anteriores, R7000P versiones 1.0.0.58 y anteriores, R7100LG versiones 1.0.0.28 y anteriores, R7300DST versiones 1.0.0.52 y anteriores, R7900 versiones 1.0.1.12 y anteriores, R8000 versiones 1.0.3.46 y anteriores, R8300 versiones 1.0.2.86 y anteriores, R8500 versiones 1.0.2.86 y anteriores, WNDR3400v3 versiones 1.0.1.8 y anteriores, y WNDR4500v2 versiones 1.0.0.62 y anteriores." } ], "id": "CVE-2017-18853", "lastModified": "2024-11-21T03:21:05.863", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-29T14:15:12.370", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000045848/Security-Advisory-for-Password-Recovery-and-File-Access-on-Some-Routers-and-Modem-Routers-PSV-2017-0677" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000045848/Security-Advisory-for-Password-Recovery-and-File-Access-on-Some-Routers-and-Modem-Routers-PSV-2017-0677" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-15 14:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, D3600 before 1.0.0.75, D6000 before 1.0.0.75, R9000 before 1.0.4.26, R8900 before 1.0.4.26, R7800 before 1.0.2.52, WNDR4500v3 before 1.0.0.58, WNDR4300v2 before 1.0.0.58, WNDR4300 before 1.0.2.104, WNDR3700v4 before 1.0.2.102, and WNR2000v5 before 1.0.0.66.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA3E7329-F839-4DD3-921F-B9E8DEDC8F12", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D34DD834-FE59-4F04-9448-FDC385CF70F6", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEF7967B-5FA3-4D43-BEC5-2644FBB1D168", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F3D02E3-8FA1-4129-A4B2-25235AF0E49C", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, D3600 before 1.0.0.75, D6000 before 1.0.0.75, R9000 before 1.0.4.26, R8900 before 1.0.4.26, R7800 before 1.0.2.52, WNDR4500v3 before 1.0.0.58, WNDR4300v2 before 1.0.0.58, WNDR4300 before 1.0.2.104, WNDR3700v4 before 1.0.2.102, and WNR2000v5 before 1.0.0.66." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.60, D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, R9000 versiones anteriores a 1.0.4.26, R8900 versiones anteriores a 1.0.4.26, R7800 versiones anteriores a 1.0.2.52, WNDR4500v3 versiones anteriores a 1.0.0.58, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4300 versiones anteriores a 1.0.2.104, WNDR3700v4 versiones anteriores a 1.0.2.102 y WNR2000v5 versiones anteriores a 1.0.0.66." } ], "id": "CVE-2019-20767", "lastModified": "2024-11-21T04:39:18.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-15T14:15:18.560", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060632/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0116" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060632/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0116" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | ex8000_firmware | * | |
netgear | ex8000 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048", "versionEndExcluding": "1.0.1.180", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1. 0,1,76, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7300 versiones anteriores a 1.0.2.136, EX8000 versiones anteriores a 1.0.1.180, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1. 0.4.2, R9000 versiones anteriores a 1.0.4.2, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR3700v4 versiones anteriores a 1.0.2. 102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20688", "lastModified": "2024-11-21T04:39:05.197", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:23.260", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061451/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0142" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061451/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0142" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-10-09 13:15
Modified
2024-11-21 04:32
Severity ?
Summary
Certain NETGEAR devices allow remote attackers to disable all authentication requirements by visiting genieDisableLanChanged.cgi. The attacker can then, for example, visit MNU_accessPassword_recovered.html to obtain a valid new admin password. This affects AC1450, D8500, DC112A, JNDR3000, LG2200D, R4500, R6200, R6200V2, R6250, R6300, R6300v2, R6400, R6700, R6900P, R6900, R7000P, R7000, R7100LG, R7300, R7900, R8000, R8300, R8500, WGR614v10, WN2500RPv2, WNDR3400v2, WNDR3700v3, WNDR4000, WNDR4500, WNDR4500v2, WNR1000, WNR1000v3, WNR3500L, and WNR3500L.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md | Exploit, Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac1450_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3AE717E0-B9A2-4A3F-843C-D9A1AEF8D024", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac1450:-:*:*:*:*:*:*:*", "matchCriteriaId": "E4BA18B2-8234-4C26-B865-741D467C5EBE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E41AF1C1-1F19-4115-AFCD-532FBEA8E3EC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C5C9E5B5-8E65-4593-9F95-92D5C177489D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jndr3000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8B781F1-A82B-4D4B-AEF6-BDBEEE6D6DFF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jndr3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DEEEEE5-0798-450E-BF9D-B17A15235C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lg2200d_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D4C2805-BDCA-4ECA-9E4F-B802AECC3E88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lg2200d:-:*:*:*:*:*:*:*", "matchCriteriaId": "410EAA8C-48DF-4B61-875A-8F51048E19B4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r4500_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C461751-BF10-4441-9A2F-10AF054072FB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r4500:-:*:*:*:*:*:*:*", "matchCriteriaId": "7FCCD5B9-03F9-42CF-B7A5-27A7239FEDB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6200_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "58FBF5B0-466A-4D88-941C-F0DDFC87F4BE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8A466B29-3ADA-46D9-824C-8DF9160B7DD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6200v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7D512D3-2F48-442A-97F8-DA43A22DD010", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6200v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "B5694D19-2577-41B3-87B8-2B50868EA946", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1ED72E5B-9DCF-4A20-8BF1-810BCD9383E5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E9E9091-E6F8-4BE5-8B31-6682B2C2CE95", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "9597966A-B13C-4098-838B-EC9AA8DE443D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2EC1E8B7-43FB-46B3-9329-70F2E31292D1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "08F1474F-34C8-4A04-ABB6-ED3D57A67566", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "766E6051-787B-414E-BF8B-9663686203AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC4BCACA-BA08-4595-B829-C3D68EC0F353", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8041FCF6-A8DB-494E-8542-80FC3BAB22FC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "18FFC1CE-3238-4E4E-9283-D95C142EEC7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "EDCA79CB-4006-4F08-83DC-3B72A02E2511", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "79B9CF4B-F6F0-4BCF-BC30-09A4D0C3E8A6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A483635-B300-4D6A-9E1A-CD776A55D48F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "29B13F94-F151-4F00-95C3-D9FB22B3CC2B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7359F6C9-A987-4E51-89C1-81A100CEA4D8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4DE7D9C1-33AA-489D-8A66-E6C456D38929", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "951636C7-B531-4395-A89A-DEAA6AE2093F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF07E3BB-5FDE-4C79-A893-E6111AED30A5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wgr614v10_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "27BF75F1-13E5-497C-A606-805585BA2CAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wgr614v10:-:*:*:*:*:*:*:*", "matchCriteriaId": "6069BE1B-C458-4E51-B704-071BB932F290", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rpv2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "110E1E63-3225-4692-98C4-34FF145548D8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "65FACC9E-3E0E-4416-9280-706F4FCE436A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CFD82DF-14C0-4D93-A871-C2E71203D1A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "B3DB8021-1BC8-4520-A790-C5A3A3ABDA6E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700v3_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "42FE5EE4-15C3-492C-A006-7BED45C28BC4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "603836E6-E7FF-43C7-A410-8BD9D0950F7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E706326B-FCB4-4F23-9323-B5E92505ECB1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4000:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C34EC74-D6F1-46F1-B47E-E62793171427", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "48524781-AD79-4EBE-8DA3-48A64A09257D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E9F459C-B628-402A-AF4A-72E08FE41837", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "47F2C4B9-4B82-49B8-ABBC-C6937281EFB9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFB2BF35-952C-4E34-AE59-6D73041EB278", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2CDF6210-D67B-4434-A619-EC3876D4E745", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6E9507F-EE84-4C27-BF38-CEFAB453339F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000v3_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "51C2FC1C-6D85-49C5-AC9F-E0114A3A0999", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "252E5C7B-EF02-4374-A43E-02FAA9E697D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "9BF3B420-3843-4A62-BC48-50F6A4898D2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:-:*:*:*:*:*:*:*", "matchCriteriaId": "30A92EDA-46B6-4C2E-AC05-A192FFA90B85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices allow remote attackers to disable all authentication requirements by visiting genieDisableLanChanged.cgi. The attacker can then, for example, visit MNU_accessPassword_recovered.html to obtain a valid new admin password. This affects AC1450, D8500, DC112A, JNDR3000, LG2200D, R4500, R6200, R6200V2, R6250, R6300, R6300v2, R6400, R6700, R6900P, R6900, R7000P, R7000, R7100LG, R7300, R7900, R8000, R8300, R8500, WGR614v10, WN2500RPv2, WNDR3400v2, WNDR3700v3, WNDR4000, WNDR4500, WNDR4500v2, WNR1000, WNR1000v3, WNR3500L, and WNR3500L." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR permiten a atacantes remotos deshabilitar todos los requisitos de autenticaci\u00f3n visitando el archivo genieDisableLanChanged.cgi. El atacante puede, por ejemplo, visitar MNU_accessPassword_recovered.html para obtener una nueva contrase\u00f1a de administrador v\u00e1lida. Esto afecta a AC1450, D8500, DC112A, JNDR3000, LG2200D, R4500, R6200, R6200V2, R6250, R6300, R6300v2, R6400, R6700, R6900P, R6900, R7000P, R7000, R7100LG, R7300, R7900, R8000, R8300, R8500, WGR614v10, WN2500RPv2, WNDR3400v2, WNDR3700v3, WNDR4000, WNDR4500, WNDR4500v2, WNR1000, WNR1000v3, WNR3500L y WNR3500L." } ], "id": "CVE-2019-17372", "lastModified": "2024-11-21T04:32:12.360", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-10-09T13:15:16.863", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/netgear_cgi_unauthorized_access_vulnerability.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 20:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21177", "lastModified": "2024-11-21T04:03:05.923", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T20:15:11.947", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055181/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2622" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055181/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2622" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 22:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21165", "lastModified": "2024-11-21T04:03:03.733", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T22:15:12.443", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055194/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3170" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 17:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d3600_firmware | * | |
netgear | d3600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21222", "lastModified": "2024-11-21T04:03:12.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T17:15:12.930", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055115/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2458" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 13:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D8426F7-28E5-4903-8936-B6F8D5733142", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08D74CD0-EEE6-4A1D-809C-C0ED7E69489E", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E460D519-DDF3-4E59-9E41-050DC3723FD7", "versionEndExcluding": "1.0.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FAAE779-B8EA-42A3-BF22-FF17D779300E", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B562B414-1A33-4E81-83FF-D8750D977DDC", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.28, EX2700 versiones anteriores a 1.0.1.32, EX6200v2 versiones anteriores a 1.0.1.56, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.3.6, WN2000RPTv3 versiones anteriores a 1.0.1. 20, WN3000RPv3 versiones anteriores a 1.0.2.52, WN3100RPv2 versiones anteriores a 1.0.0.42, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21181", "lastModified": "2024-11-21T04:03:06.550", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T13:15:12.480", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-01-17 09:59
Modified
2024-11-21 03:27
Severity ?
Summary
An issue was discovered on NETGEAR R8500, R8300, R7000, R6400, R7300, R7100LG, R6300v2, WNDR3400v3, WNR3500Lv2, R6250, R6700, R6900, and R8000 devices. They are prone to password disclosure via simple crafted requests to the web management server. The bug is exploitable remotely if the remote management option is set, and can also be exploited given access to the router over LAN or WLAN. When trying to access the web panel, a user is asked to authenticate; if the authentication is canceled and password recovery is not enabled, the user is redirected to a page that exposes a password recovery token. If a user supplies the correct token to the page /passwordrecovered.cgi?id=TOKEN (and password recovery is not enabled), they will receive the admin password for the router. If password recovery is set the exploit will fail, as it will ask the user for the recovery questions that were previously set when enabling that feature. This is persistent (even after disabling the recovery option, the exploit will fail) because the router will ask for the security questions.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability | Vendor Advisory | |
cve@mitre.org | http://www.securityfocus.com/bid/95457 | Broken Link, Third Party Advisory, VDB Entry | |
cve@mitre.org | https://www.exploit-db.com/exploits/41205/ | Exploit, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/95457 | Broken Link, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.exploit-db.com/exploits/41205/ | Exploit, Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6200_firmware | 1.0.1.56_1.0.43 | |
netgear | r6200 | - | |
netgear | r6300_firmware | 1.0.2.78_1.0.58 | |
netgear | r6300 | - | |
netgear | vegn2610_firmware | 1.0.0.36 | |
netgear | vegn2610 | - | |
netgear | ac1450_firmware | 1.0.0.34_10.0.16 | |
netgear | ac1450 | - | |
netgear | wnr1000v3_firmware | 1.0.2.68_60.0.93 | |
netgear | wnr1000v3 | - | |
netgear | wndr3700v3_firmware | 1.0.0.40_1.0.32 | |
netgear | wndr3700v3 | - | |
netgear | wndr4000_firmware | 1.0.2.4_9.1.86 | |
netgear | wndr4000 | - | |
netgear | wndr4500_firmware | 1.0.1.44_1.0.73 | |
netgear | wndr4500 | - | |
netgear | d6400_firmware | 1.0.0.44 | |
netgear | d6400 | - | |
netgear | d6220_firmware | 1.0.0.12 | |
netgear | d6220 | - | |
netgear | d6300_firmware | 1.0.0.96 | |
netgear | d6300 | - | |
netgear | d6300b_firmware | 1.0.0.40 | |
netgear | d6300b | - | |
netgear | dgn2200bv4_firmware | 1.0.0.68 | |
netgear | dgn2200bv4 | - |
{ "cisaActionDue": "2022-09-29", "cisaExploitAdd": "2022-09-08", "cisaRequiredAction": "Apply updates per vendor instructions. If the affected device has since entered end-of-life, it should be disconnected if still in use.", "cisaVulnerabilityName": "NETGEAR Multiple Devices Exposure of Sensitive Information Vulnerability", "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6200_firmware:1.0.1.56_1.0.43:*:*:*:*:*:*:*", "matchCriteriaId": "1C1769F8-B2CB-465B-85B8-9D7AC25C63CB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8A466B29-3ADA-46D9-824C-8DF9160B7DD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:1.0.2.78_1.0.58:*:*:*:*:*:*:*", "matchCriteriaId": "89A99D1C-CABE-4526-B3B7-3708C0E18AC4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "9597966A-B13C-4098-838B-EC9AA8DE443D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:vegn2610_firmware:1.0.0.36:*:*:*:*:*:*:*", "matchCriteriaId": "6D329D85-C180-426E-B430-9FEDE5C77F25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:vegn2610:-:*:*:*:*:*:*:*", "matchCriteriaId": "0967FC76-F977-4D18-B570-9444459A19FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac1450_firmware:1.0.0.34_10.0.16:*:*:*:*:*:*:*", "matchCriteriaId": "91292776-92F7-4089-86FC-7569C8F940DE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac1450:-:*:*:*:*:*:*:*", "matchCriteriaId": "E4BA18B2-8234-4C26-B865-741D467C5EBE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000v3_firmware:1.0.2.68_60.0.93:*:*:*:*:*:*:*", "matchCriteriaId": "4E35A89F-44C7-496C-B61B-652989EDE438", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "252E5C7B-EF02-4374-A43E-02FAA9E697D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700v3_firmware:1.0.0.40_1.0.32:*:*:*:*:*:*:*", "matchCriteriaId": "1D59A6F9-0359-4AB4-AD0F-1D6044D59409", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "603836E6-E7FF-43C7-A410-8BD9D0950F7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4000_firmware:1.0.2.4_9.1.86:*:*:*:*:*:*:*", "matchCriteriaId": "91561A20-30F5-4163-9178-5FC32897F827", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4000:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C34EC74-D6F1-46F1-B47E-E62793171427", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:1.0.1.44_1.0.73:*:*:*:*:*:*:*", "matchCriteriaId": "B9874914-4D90-493F-BD2B-40FFF1737F58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E9F459C-B628-402A-AF4A-72E08FE41837", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:1.0.0.44:*:*:*:*:*:*:*", "matchCriteriaId": "D3EB5F49-3628-4418-AF36-AF8FD6F5BA25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:1.0.0.12:*:*:*:*:*:*:*", "matchCriteriaId": "ECD46588-5866-4159-85E1-58B0D1F98406", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6300_firmware:1.0.0.96:*:*:*:*:*:*:*", "matchCriteriaId": "7B15B85C-F099-4584-9F59-1CFC3275D625", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "78542C95-85CC-43E5-9F0E-B12DDD5B79C4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6300b_firmware:1.0.0.40:*:*:*:*:*:*:*", "matchCriteriaId": "D0CE8A8F-7894-4140-8E4B-84153C5A6B13", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6300b:-:*:*:*:*:*:*:*", "matchCriteriaId": "37B89703-CAFB-43F6-8880-90349F8ED856", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200bv4_firmware:1.0.0.68:*:*:*:*:*:*:*", "matchCriteriaId": "E1CDFE4F-6C5C-4B10-926E-92C7759D60EF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200bv4:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C78A475-9DDF-432B-A94A-01EFAC7DC70D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on NETGEAR R8500, R8300, R7000, R6400, R7300, R7100LG, R6300v2, WNDR3400v3, WNR3500Lv2, R6250, R6700, R6900, and R8000 devices. They are prone to password disclosure via simple crafted requests to the web management server. The bug is exploitable remotely if the remote management option is set, and can also be exploited given access to the router over LAN or WLAN. When trying to access the web panel, a user is asked to authenticate; if the authentication is canceled and password recovery is not enabled, the user is redirected to a page that exposes a password recovery token. If a user supplies the correct token to the page /passwordrecovered.cgi?id=TOKEN (and password recovery is not enabled), they will receive the admin password for the router. If password recovery is set the exploit will fail, as it will ask the user for the recovery questions that were previously set when enabling that feature. This is persistent (even after disabling the recovery option, the exploit will fail) because the router will ask for the security questions." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos NETGEAR R8500, R8300, R7000, R6400, R7300, R7100LG, R6300v2, WNDR3400v3, WNR3500Lv2, R6250, R6700, R6900 y R8000. Son propensos a revelar la contrase\u00f1a a trav\u00e9s de peticiones simples manipuladas al servidor de gesti\u00f3n de la web. El error es explotable remotamente si la opci\u00f3n de gesti\u00f3n remota est\u00e1 activada, y tambi\u00e9n puede ser explotado dado el acceso al router a trav\u00e9s de LAN o WLAN. Cuando se trata de acceder al panel web, se pide al usuario que se autentique; si la autenticaci\u00f3n se cancela y la recuperaci\u00f3n de contrase\u00f1a no est\u00e1 habilitada, el usuario es redirigido a una p\u00e1gina que revela un token de recuperaci\u00f3n de contrase\u00f1a. Si un usuario proporciona el token correcto a la p\u00e1gina /passwordrecovered.cgi?id=TOKEN (y la recuperaci\u00f3n de contrase\u00f1a no est\u00e1 habilitada), recibir\u00e1n la contrase\u00f1a de administrador para el router. Si la recuperaci\u00f3n de contrase\u00f1a est\u00e1 habilitada, la explotaci\u00f3n fallar\u00e1, ya que pedir\u00e1 al usuario preguntas para la recuperaci\u00f3n que fueron previamente establecidas cuando se habilit\u00f3 esa caracter\u00edstica. Esto es persistente (incluso tras la inhabilitaci\u00f3n de la opci\u00f3n de recuperaci\u00f3n, la explotaci\u00f3n fallar\u00e1) porque el router preguntar\u00e1 por las preguntas de seguridad." } ], "id": "CVE-2017-5521", "lastModified": "2024-11-21T03:27:48.497", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-01-17T09:59:00.333", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability" }, { "source": "cve@mitre.org", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/95457" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "https://www.exploit-db.com/exploits/41205/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://kb.netgear.com/30632/Web-GUI-Password-Recovery-and-Exposure-Security-Vulnerability" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/95457" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "https://www.exploit-db.com/exploits/41205/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 20:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50 y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21176", "lastModified": "2024-11-21T04:03:05.770", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T20:15:11.897", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055182/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2623" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055182/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2623" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r7500_firmware | * | |
netgear | r7500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1. 0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21197", "lastModified": "2024-11-21T04:03:09.080", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.043", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055152/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2596" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055152/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2596" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 16:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.61, D6000 before 1.0.0.61, D6100 before 1.0.0.55, D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r6100_firmware | * | |
netgear | r6100 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63465654-D9ED-454C-9A42-0E648952B3B1", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1E5FEB3-943A-44F7-9803-3B6DBDC1253E", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7", "versionEndExcluding": "1.0.0.55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1664969-D326-4EC5-BF0D-E43820CCB378", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:*:*:*:*:*:*:*:*", "matchCriteriaId": "95E0A938-7669-4B25-97B8-5E3290333DBD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.61, D6000 before 1.0.0.61, D6100 before 1.0.0.55, D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D3600 versiones anteriores a 1.0.0.61, D6000 versiones anteriores a 1.0.0.61, D6100 versiones anteriores a 1.0.0.55, D7800 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.16, R7500 versiones anteriores a 1.0.0.112, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.36, R9000 versiones anteriores a 1.0.2.40, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.58." } ], "id": "CVE-2017-18740", "lastModified": "2024-11-21T03:20:48.380", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T16:15:12.400", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051515/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0615" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051515/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0615" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E460D519-DDF3-4E59-9E41-050DC3723FD7", "versionEndExcluding": "1.0.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, D7800 versiones anteriores a 1.0.1.34, R6100 versiones anteriores a 1.0.1.20, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1. 0.3.6, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21195", "lastModified": "2024-11-21T04:03:08.770", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:12.873", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055162/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2600" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055162/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2600" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-05-05 14:15
Modified
2024-11-21 03:21
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6100 before 1.0.0.55, D7800 before V1.0.1.24, R7100LG before V1.0.0.32, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7100lg_firmware | * | |
netgear | r7100lg | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7", "versionEndExcluding": "1.0.0.55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3197737-90A5-411B-8F3D-902D7FD3CEB6", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "833A98AF-A4B0-4C68-AACD-6B3F58E64060", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6100 before 1.0.0.55, D7800 before V1.0.1.24, R7100LG before V1.0.0.32, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D6100 versiones anteriores a 1.0.0.55, D7800 versiones anteriores a V1.0.1.24, R7100LG versiones anteriores a V1.0.0.32, WNDR4300v1 versiones anteriores a 1.0.2.90, y WNDR4500v3 versiones anteriores a 1.0.0.48." } ], "id": "CVE-2017-18867", "lastModified": "2024-11-21T03:21:08.000", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-05-05T14:15:12.390", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049554/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2198" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049554/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2198" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7000 before 2018-03-01, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 2018-03-01, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "080C16FD-7821-487B-AAE9-F365D731550A", "versionEndExcluding": "2018-03-01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D555F0B-AABE-4AB7-884B-BBB8E807ECC9", "versionEndExcluding": "1.0.1.31", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C88AE720-9506-446F-A0AD-0B5ADFF1BB21", "versionEndExcluding": "1.0.3.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E90EB0CF-D659-435C-8BDD-379286F0351A", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E61E9642-91C9-4CA8-BB93-0DE1FEFF48BC", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8EEBDA31-7845-4598-8E40-63CEF5037E84", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB7C8C95-6E03-4785-AC18-BFAECFF399E6", "versionEndExcluding": "2018-03-01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9886E8AE-A8D3-46E3-95E6-6EEAA2B6B581", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14253C3A-712C-4A7E-83C4-88A6BBEF0AB2", "versionEndExcluding": "1.1.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE68337A-BA04-424A-8DFC-EEE06400D60F", "versionEndExcluding": "1.1.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DBDE97EB-05FE-475E-8A4E-13C97E91548A", "versionEndExcluding": "1.0.2.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D20223D6-9BC2-40CA-9783-2DE0F5F12F64", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E4EF1D0-C132-443E-B7FB-BE050F825D5B", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1088BCE7-C53C-424F-8041-6404D42922F4", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F7508FAE-C117-4E21-8D3D-0016E25363DB", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F889C021-1D38-4A7B-94B4-78FE47699827", "versionEndExcluding": "1.1.4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93CD0427-0CE9-4F1C-933D-0FE6B5626FAC", "versionEndExcluding": "1.1.4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAAB159C-27F2-4645-9FE4-4DBB4465DE3A", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A79D8A77-4555-4B2A-8F19-F69AD4A17D2E", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "026C640E-7594-4B5A-BDF9-FAB1CD135A47", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "055A63BF-1787-4B72-8416-B6F77025F738", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5025770E-D9D0-4FB6-BE29-1F48EDC31AF1", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26E7527-682C-4145-8AE3-F44661285514", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29839E12-4949-49EA-B396-968BB832AE8D", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "51F31B60-7B0F-41AC-9FEF-FAAD54269194", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57B186F2-4D0D-44BD-9F5F-DC1D9FD12C5A", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55A6E04A-1630-4C5F-8173-B6B725A59D46", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7000 before 2018-03-01, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 2018-03-01, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por la configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D7000 antes del 01-03-2018, D7800 versiones anteriores a 1.0.1.31, D8500 versiones anteriores a 1.0.3.36, JNR1010v2 versiones anteriores a 1.1.0.46, JR6150 versiones anteriores a 1.0.1.14, JWNR2010v5 versiones anteriores a 1.1.0.46, PR2000 antes del 01-03-2018, R6050 versiones anteriores a 1.0.1.14, R6220 versiones anteriores a 1.1.0.60, R6400 versiones anteriores a 1.1.0.26, R6400v2 versiones anteriores a 1.0.2.46, R6700v2 versiones anteriores a 1.2.0.2, R6800 versiones anteriores a 1.2.0.2, R6900v2 versiones anteriores a 1.2.0.2, R7300DST versiones anteriores a 1.0.0.56, R7500 versiones anteriores a 1.0. 0.112, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.36, R7900P versiones anteriores a 1.1.4.6, R8000P versiones anteriores a 1.1.4.6, R8300 versiones anteriores a 1.0.2.104, R8500 versiones anteriores a 1.0.2.104, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.94, WNDR3700v5 versiones anteriores a 1.1.0.50, WNDR4300 versiones anteriores a 1.0.2.96, WNDR4300v2 versiones anteriores a 1.0.0.52, WNDR4500v3 versiones anteriores a 1.0.0.52, WNR1000v4 versiones anteriores a 1.1.0.46, WNR2020 versiones anteriores a 1.1.0.46 y WNR2050 versiones anteriores a 1.1.0.46." } ], "id": "CVE-2018-21169", "lastModified": "2024-11-21T04:03:04.397", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.793", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055189/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2913" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055189/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2913" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r900_firmware | * | |
netgear | r900 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3ABBD2E7-85AA-4EDA-908C-410D44DD74DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r900:-:*:*:*:*:*:*:*", "matchCriteriaId": "F75EB581-AACC-401D-ACA7-0BCA73D12621", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, EX2700 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1. 0.2.52, WN2000RPTv3 versiones anteriores a 1.0.1.20, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21207", "lastModified": "2024-11-21T04:03:10.640", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.700", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055142/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2566" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D7800 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2017-18705", "lastModified": "2024-11-21T03:20:42.657", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:12.677", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053197/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0526" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053197/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-0526" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 21:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a R7800 versiones anteriores a la versi\u00f3n 1.0.2.40, R9000 versiones anteriores a la versi\u00f3n 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50 y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21178", "lastModified": "2024-11-21T04:03:06.087", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T21:15:13.093", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055180/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2621" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055180/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2621" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 04:02
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "600F0894-2001-4681-8B7C-AE24B3C81EA4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCEAE442-EE2A-4F16-90FD-13369A0C972C", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DEB74216-7276-474B-8339-1A42D4CD17E7", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "029862D3-6AA0-42E9-955A-2505715BE466", "versionEndExcluding": "1.0.0.130", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9295BC98-9E8D-4812-B2CE-69D848E589DE", "versionEndExcluding": "1.0.3.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.58, D7800 versiones anteriores a 1.0.1.42, R6100 versiones anteriores a 1.0.1.28, R7500 versiones anteriores a 1.0.0.130, R7500v2 versiones anteriores a 1.0.3.36, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56 y WNDR4500v3 versiones anteriores a 1.0.0.56." } ], "id": "CVE-2018-21113", "lastModified": "2024-11-21T04:02:55.967", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:13.473", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.63, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1.0.2. 102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20727", "lastModified": "2024-11-21T04:39:11.923", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.587", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061201/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2018-0139" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061201/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2018-0139" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 20:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.34, JNR1010v2 before 1.1.0.50, JWNR2010v5 before 1.1.0.50, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, R6020 before 1.0.0.30, R6080 before 1.0.0.30, R6100 before 1.0.1.16, R6120 before 1.0.0.40, R6700v2 before 1.2.0.14, R6800 before 1.2.0.14, R6900v2 before 1.2.0.14, R7500v2 before 1.0.3.26, R7800 before 1.0.2.46, R9000 before 1.0.4.2, WN3000RPv2 before 1.0.0.52, WN3000RPv3 before 1.0.2.78, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.50, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.50, and WNR2050 before 1.1.0.50. NOTE: this may be a result of an incomplete fix for CVE-2017-18866.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "600F0894-2001-4681-8B7C-AE24B3C81EA4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "37091E40-F36D-4111-B276-8A047415DEE7", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5B3009A-32AC-4FB2-8E55-5648CD4649E5", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7ED1541-DE7D-4A4C-B8D1-CB42E52E3DBE", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "094B04D5-9063-4D7A-B367-E1F2688B3667", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C489444C-6C19-4A52-AF66-A1D48ADC4F26", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D6473B1-757C-4B6E-82D3-D1D13731F074", "versionEndExcluding": "1.0.0.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23D08587-3258-4B55-AA21-AB7E6D9A8421", "versionEndExcluding": "1.0.0.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA46A42B-6439-4DFC-BA9E-CDC3438AAF77", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "021EFB0E-8498-4400-8044-B778232577E6", "versionEndExcluding": "1.2.0.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC4D8ECD-014E-46DD-9CC3-FB0BDD652E17", "versionEndExcluding": "1.2.0.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F92BB0A-7BFE-46FB-A850-9D82635AA8EB", "versionEndExcluding": "1.2.0.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "238A0EC8-F5E6-4AB6-A132-0763B6F687EC", "versionEndExcluding": "1.0.2.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "655A51AC-713E-4D9F-AF50-107EA0DFBC37", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "250E8C27-ED0F-46FC-B630-52E9BF2CA812", "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "832B6460-9984-4441-8E06-F784052FC8CC", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8E5BDCB-5273-434C-A8F5-7F8184FD2457", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7928C6DB-B9E2-41EB-AE71-C5DD19EEEEBA", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D38DF1BB-32A1-4051-882D-7D9E56A757F1", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.34, JNR1010v2 before 1.1.0.50, JWNR2010v5 before 1.1.0.50, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, R6020 before 1.0.0.30, R6080 before 1.0.0.30, R6100 before 1.0.1.16, R6120 before 1.0.0.40, R6700v2 before 1.2.0.14, R6800 before 1.2.0.14, R6900v2 before 1.2.0.14, R7500v2 before 1.0.3.26, R7800 before 1.0.2.46, R9000 before 1.0.4.2, WN3000RPv2 before 1.0.0.52, WN3000RPv3 before 1.0.2.78, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.50, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.50, and WNR2050 before 1.1.0.50. NOTE: this may be a result of an incomplete fix for CVE-2017-18866." }, { "lang": "es", "value": "Ciertos dispositivos NETGEAR se ven afectados por XSS almacenado. Esto afecta a D6100 antes de 1.0.0.58, D7800 antes de 1.0.1.34, JNR1010v2 antes de 1.1.0.50, JWNR2010v5 antes de 1.1.0.50, RBK50 antes de 2.3.5.30, RBR50 antes de 2.3.5.30, RBS50 antes de 2.3.5.30, R6020 antes de 1.0.0.30, R6080 antes de 1.0.0.30, R6100 antes de 1.0.1.16, R6120 antes de 1.0.0.40, R6700v2 antes de 1.2.0.14, R6800 antes de 1.2.0.14, R6900v2 antes de 1.2.0.14, R7500v2 antes de 1.0.3.26, R7800 antes de 1.0.2.46, R9000 antes 1.0.4.2, WN3000RPv2 antes de 1.0.0.52, WN3000RPv3 antes de 1.0.2.78, WNDR3700v4 antes de 1.0.2.102, WNDR3700v5 antes de 1.1.0.54, WNDR4300v1 antes de 1.0.2.104, WNDR4300v2 antes de 1.0.0.48, WNDR4500v3 antes de 1.0.0.48, WNDR4500v3 antes de 1.0.0.48 0.50, WNR2000v5 antes de 1.0.0.64, WNR2020 antes de 1.1.0.50 y WNR2050 antes de 1.1.0.50. NOTA: esto puede ser el resultado de una soluci\u00f3n incompleta para CVE-2017-18866." } ], "id": "CVE-2019-20738", "lastModified": "2024-11-21T04:39:13.863", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.1, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T20:15:13.820", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061187/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2016-0100" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061187/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2016-0100" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 20:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a la versi\u00f3n 1.0.0.57, R6100 versiones anteriores a la versi\u00f3n 1.0.1.20, R7800 versiones anteriores a la versi\u00f3n 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21175", "lastModified": "2024-11-21T04:03:05.620", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T20:15:11.837", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055183/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2624" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055183/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2624" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.57, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.78, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | ex8000_firmware | * | |
netgear | ex8000 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D8426F7-28E5-4903-8936-B6F8D5733142", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C5401F4-5D39-4A08-BB79-DD6CB2D4C94A", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CC8DA05-7E8B-4759-9FA8-69626A90662E", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79641CA1-DCB5-4793-A710-CBEC23809C7F", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66120328-5681-46E5-86A5-CAC62B9243B9", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "974F3120-1A73-4301-A720-E31C9C27B41C", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C1D8706-BB8E-4EBC-B76C-533062BF86EE", "versionEndExcluding": "1.0.0.114", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058BC554-8E48-460E-A305-B5CDA8249B28", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAFDAF9A-711E-497F-8632-0345B635A7C9", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B562B414-1A33-4E81-83FF-D8750D977DDC", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.57, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.78, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, DM200 versiones anteriores a 1.0.0.50, EX2700 versiones anteriores a 1.0.1.32, EX6100v2 versiones anteriores a 1.0.1.70, EX6150v2 versiones anteriores a 1.0.1.70, EX6200v2 versiones anteriores a 1.0.1.62, EX6400 versiones anteriores a 1.0.1.78, EX7300 versiones anteriores a 1.0.1.78, EX8000 versiones anteriores a 1.0.0.114, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WN2000RPTv3 versiones anteriores a 1.0.1.26, WN3000RPv3 versiones anteriores a 1.0.2.66, WN3100RPv2 versiones anteriores a 1.0.0.42, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21167", "lastModified": "2024-11-21T04:03:04.040", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.670", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055191/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Routers-Gateways-Extenders-and-DSL-Modems-PSV-2017-3093" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055191/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Routers-Gateways-Extenders-and-DSL-Modems-PSV-2017-3093" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r900_firmware | * | |
netgear | r900 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3ABBD2E7-85AA-4EDA-908C-410D44DD74DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r900:-:*:*:*:*:*:*:*", "matchCriteriaId": "F75EB581-AACC-401D-ACA7-0BCA73D12621", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, EX2700 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1. 0.2.52, WN2000RPTv3 versiones anteriores a 1.0.1.20, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21210", "lastModified": "2024-11-21T04:03:11.097", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.887", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055139/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2492" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055139/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2492" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 14:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6150v2 before 1.0.1.54, EX6100v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.18, R6900P before 1.3.0.8, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R8000 before 1.0.4.4_1.1.42, R7900P before 1.1.5.14, R8000P before 1.1.5.14, R8300 before 1.0.2.110, R8500 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.14, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA902AA9-525D-46BD-B586-1A0DC40EE391", "versionEndExcluding": "1.1.00.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1FD6552E-5BF6-4E57-90A7-39C4543B469C", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE087F75-4C99-425C-A9B7-B261E5545297", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "327F762B-1F65-4DE0-B05C-1AAC64974A14", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34A8EAED-389E-4B14-949E-ED87A09F4D91", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9398174B-A4A6-449A-AB91-A93D3D9398DD", "versionEndExcluding": "1.0.3.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0ABDCFC2-E9EC-40F4-862F-B86FDD0A6AC7", "versionEndExcluding": "1.0.0.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D989DB4-5276-4BCF-A15E-BC207E03B2C7", "versionEndExcluding": "1.0.0.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F476F7D7-EAE2-4A09-8C4B-A53F885A1337", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EFE54D2-78A3-4461-BA5E-6807911C5684", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BCBD76F6-4E46-42E1-A6B6-373F2F7DB4AF", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "85392ECB-985F-43B2-89BE-755E433FC14B", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0D1F6E4-A21F-4B86-B903-C26BB062D0DD", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BBA04A7E-6029-498B-970E-0317BE0CF0F2", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC9E7939-E195-44AB-8880-D0BCF26BF2E0", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34429B2B-D8CB-4BEC-B5FA-5C7F8AC9A1FE", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDFB6345-0D0D-4586-9899-2438AADDCD3F", "versionEndExcluding": "1.0.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5E7A8CA-134F-49B4-95D6-79A88CD6BB80", "versionEndExcluding": "1.0.4.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55058831-92FF-4A87-8340-E25AC0DDF89E", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "97DE1C91-59A0-4902-B5C7-0CFD2631CAEE", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DBDE97EB-05FE-475E-8A4E-13C97E91548A", "versionEndExcluding": "1.0.2.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "442F153C-737B-44D4-9A6D-EB6F6C47B986", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F70E0C-3674-4981-B815-0721F6C6E588", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03DC2062-58D1-40D6-8536-A13C87F2CF11", "versionEndExcluding": "1.0.9.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "326BBECA-9A76-4A3E-90F7-023797D5D186", "versionEndExcluding": "1.3.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09963BE1-D57D-491A-9BD8-A1A46ED993E0", "versionEndExcluding": "1.3.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2FB08FA1-A476-4E05-9904-9BE30C9E77B7", "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B75230D7-5B50-47C2-B5C5-C60C6974C305", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BCE1150D-8464-4421-94BD-EE81977BAC34", "versionEndExcluding": "1.0.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "532B87A3-CE33-4F0F-A0A7-C7D7D568C593", "versionEndExcluding": "1.0.4.4_1.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "606460FB-B46F-4490-96FC-B226F3A2C55D", "versionEndExcluding": "1.1.5.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B508ABA6-F17C-43D4-88D8-56ECD0057C65", "versionEndExcluding": "1.1.5.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DDFEFE-402D-4AA8-A2C9-2217A5643DC1", "versionEndExcluding": "1.0.2.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7A3E675-BB4F-4E8B-A041-C208F85B5C0E", "versionEndExcluding": "1.0.2.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "785692C5-AA6D-43E9-B9E8-160352AC816D", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AB52FC6-BC09-41ED-BB91-63A4E795E0F8", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72DCD4C0-A757-4F98-97BD-FB1FEBF3235C", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "026C640E-7594-4B5A-BDF9-FAB1CD135A47", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5025770E-D9D0-4FB6-BE29-1F48EDC31AF1", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5684DEA-5F12-4E72-B8D1-C5F3E1D22726", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36CCD48D-4474-4363-8DE6-846714B99D3D", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436026D2-0B8E-4BA5-AD34-9EB285EDA78A", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB542F95-5AE2-47E4-BD7B-34134B26AA4F", "versionEndExcluding": "1.2.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6150v2 before 1.0.1.54, EX6100v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.18, R6900P before 1.3.0.8, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R8000 before 1.0.4.4_1.1.42, R7900P before 1.1.5.14, R8000P before 1.1.5.14, R8300 before 1.0.2.110, R8500 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.14, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D6200 versiones anteriores a 1.1.00.24, D6220 versiones anteriores a 1.0.0.32, D6400 versiones anteriores a 1.0.0.66, D7000 versiones anteriores a 1.0.1.52, D7000v2 versiones anteriores a 1.0.0.44, D7800 versiones anteriores a 1.0.1.30, D8500 versiones anteriores a 1.0.3.35, DGN2200v4 versiones anteriores a 1.0.0.96, DGN2200Bv4 versiones anteriores a 1.0.0.96, EX2700 versiones anteriores a 1.0.1.28, EX6150v2 versiones anteriores a 1.0.1.54, EX6100v2 versiones anteriores a 1.0.1.54, EX6200v2 versiones anteriores a 1.0.1.52, EX6400 versiones anteriores a 1.0.1.72, EX7300 versiones anteriores a 1.0.1.72, EX8000 versiones anteriores a 1.0.0.102, JNR1010v2 versiones anteriores a 1.1.0.44, JWNR2010v5 versiones anteriores a 1.1.0.44, PR2000 versiones anteriores a 1.0.0.20, R6100 versiones anteriores a 1.0.1.20, R6250 versiones anteriores a 1.0.4.16, R6300v2 versiones anteriores a 1.0. 4.18, R6400 versiones anteriores a 1.0.1.32, R6400v2 versiones anteriores a 1.0.2.46, R6700 versiones anteriores a 1.0.1.36, R6900 versiones anteriores a 1.0.1.34, R7000 versiones anteriores a 1.0.9.18, R6900P versiones anteriores a 1.3.0.8, R7000P versiones anteriores a 1.3.0.8, R7100LG versiones anteriores a 1.0.0.34, R7300DST versiones anteriores a 1.0.0.58, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R7900 versiones anteriores a 1.0.2.4, R8000 versiones anteriores a 1.0.4.4_1.1.42, R7900P versiones anteriores a 1.1.5.14, R8000P versiones anteriores a 1.1.5.14, R8300 versiones anteriores a 1.0.2.110, R8500 versiones anteriores a 1.0.2.110, R9000 versiones anteriores a 1.0.2.52, WN2000RPTv3 versiones anteriores a 1.0.1.14, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.40, WNDR3400v3 versiones anteriores a 1.0.1.16, WNDR3700v4 versiones anteriores a 1.0. 2.94, WNDR4300 versiones anteriores a 1.0.2.96, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, WNR1000v4 versiones anteriores a 1.1.0.44, WNR2000v5 versiones anteriores a 1.0.0.62, WNR2020 versiones anteriores a 1.1.0.44, WNR2050 versiones anteriores a 1.1.0.44 y WNR3500Lv2 versiones anteriores a 1.2.04 ." } ], "id": "CVE-2017-18788", "lastModified": "2024-11-21T03:20:55.460", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T14:15:11.817", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049527/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2947" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049527/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2947" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r900_firmware | * | |
netgear | r900 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3ABBD2E7-85AA-4EDA-908C-410D44DD74DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r900:-:*:*:*:*:*:*:*", "matchCriteriaId": "F75EB581-AACC-401D-ACA7-0BCA73D12621", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, EX2700 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WN2000RPTv3 versiones anteriores a 1. 0.1.20, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21206", "lastModified": "2024-11-21T04:03:10.490", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.543", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055143/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2567" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055143/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2567" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2. 52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21187", "lastModified": "2024-11-21T04:03:07.490", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.427", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055170/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2608" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055170/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2608" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 22:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects DGN2200 before 1.0.0.58, DGN2200B before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.80, D6220 before 1.0.0.44, EX7000 before 1.0.0.66, EX6200 before 1.0.3.88, EX6150 before 1.0.0.42, EX7500 before 1.0.0.46, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900P before 1.4.0.10, R8000P before 1.4.0.10, R7900 before 1.0.2.16, R7000P before 1.3.1.44, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.1.44, R7000 before 1.0.9.32, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.54.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "99288EE6-3A88-4134-992D-148868117AFC", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:-:*:*:*:*:*:*:*", "matchCriteriaId": "37C89394-ED7D-4C5F-9573-47A0378E22C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "082AB982-1EF7-417D-88CD-21F3860AF8C4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:-:*:*:*:*:*:*:*", "matchCriteriaId": "C85C6885-636D-4583-AEEF-FC23D93CCC35", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "629E89E8-F329-4D11-9652-540752084DD3", "versionEndExcluding": "1.0.3.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52FB0300-0FC9-4797-BACB-84D7D932A386", "versionEndExcluding": "1.0.0.51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76FA59AE-35D5-443C-8C05-3989DD59B32F", "versionEndExcluding": "1.0.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "114EDC62-9DAE-45D9-8A90-A533BBBF50EB", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F1E93FB-4926-4AF5-BA5F-A4DE4314B45F", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A81A7574-A2C7-4216-98C6-6790FA705013", "versionEndExcluding": "1.0.3.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D74896A7-7EF2-41C9-8A29-59B2EA5ABA5C", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "46452E97-9347-4788-9570-1EECECC7255E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71D30090-F8C2-47F0-991C-FEDD3D9C3864", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jndr3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07C1E707-AB63-4812-9BBC-7267AD17BFF9", "versionEndExcluding": "1.0.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jndr3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DEEEEE5-0798-450E-BF9D-B17A15235C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C5FC237-F74C-4771-B5D3-36CF245C0396", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4CA2B4B5-ED8D-476F-9F6E-630B43A38E27", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB84CB9C-DA5C-4D18-9A54-375DD091D932", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E0102F4-A45E-4715-8D3F-4DC96EC5865C", "versionEndExcluding": "1.4.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D59690E-4182-40B0-872C-8392352C0B00", "versionEndExcluding": "1.4.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "471E4F42-7114-4A7F-832D-2E9222BD25B4", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90805FFE-E59D-43D2-BF1E-D55458CF05BF", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94B3A9D8-A276-41B2-B7BF-7DA58B879A9B", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E59E66D2-7E73-45C8-8D3E-FE589CDBECA4", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52A6DEB2-3A33-4184-866D-9C8D9DD991C6", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1C19D9-9195-4C24-B346-10AAC4106B89", "versionEndExcluding": "1.0.9.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08FF0010-66E3-485C-A22B-39E57E738550", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E821B01-31C8-4766-BAAF-D814336617B9", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "203541F7-8AC5-436A-808E-935B03B00E8D", "versionEndExcluding": "1.0.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "741413AB-9519-4BBE-BEDB-DFA2077BAF79", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "502055F1-F919-4C91-A3D0-B144027BC690", "versionEndExcluding": "1.0.4.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D1A9B6F-89B2-4785-A0E2-3FD322D6A28F", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EEBD4A-4734-4F43-B7D4-39D81C83A873", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E338A30-C349-41B4-B971-E6D6B0E9AFE4", "versionEndExcluding": "1.2.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects DGN2200 before 1.0.0.58, DGN2200B before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.80, D6220 before 1.0.0.44, EX7000 before 1.0.0.66, EX6200 before 1.0.3.88, EX6150 before 1.0.0.42, EX7500 before 1.0.0.46, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900P before 1.4.0.10, R8000P before 1.4.0.10, R7900 before 1.0.2.16, R7000P before 1.3.1.44, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.1.44, R7000 before 1.0.9.32, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta a DGN2200 versiones anteriores a 1.0.0.58, DGN2200B versiones anteriores a 1.0.0.58, D8500 versiones anteriores a 1.0.3.42, D7000v2 versiones anteriores a 1.0.0.51, D6400 versiones anteriores a 1.0.0.80, D6220 versiones anteriores a 1.0.0.44, EX7000 versiones anteriores a 1.0.0. 66, EX6200 versiones anteriores a 1.0.3.88, EX6150 versiones anteriores a 1.0.0.42, EX7500 versiones anteriores a 1.0.0.46, JNDR3000 versiones anteriores a 1.0.0.24, R8000 versiones anteriores a 1.0.4.18, R8500 versiones anteriores a 1.0.2.122, R8300 versiones anteriores a 1.0.2.122, R7900P versiones anteriores a 1.4.0. 10, R8000P versiones anteriores a 1.4.0.10, R7900 versiones anteriores a 1.0.2.16, R7000P versiones anteriores a 1.3.1.44, R7300DST versiones anteriores a 1.0.0.68, R7100LG versiones anteriores a 1.0.0.46, R6900P versiones anteriores a 1.3.1.44, R7000 versiones anteriores a 1.0.9.32, R6900 versiones anteriores a 1. 0.1.46, R6700 versiones anteriores a 1.0.1.46, R6400v2 versiones anteriores a 1.0.2.56, R6400 versiones anteriores a 1.0.1.42, R6300v2 versiones anteriores a 1.0.4.28, R6250 versiones anteriores a 1.0.4.26, WNDR4500v2 versiones anteriores a 1.0.0.72, y WNR3500Lv2 versiones anteriores a 1.2.0.54." } ], "id": "CVE-2019-20754", "lastModified": "2024-11-21T04:39:16.570", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T22:15:12.853", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060628/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Modem-Routers-and-Extenders-PSV-2018-0054" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060628/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Modem-Routers-and-Extenders-PSV-2018-0054" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E460D519-DDF3-4E59-9E41-050DC3723FD7", "versionEndExcluding": "1.0.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.3.6, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21192", "lastModified": "2024-11-21T04:03:08.287", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.723", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055165/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2603" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055165/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2603" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d3600_firmware | * | |
netgear | d3600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por el desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21213", "lastModified": "2024-11-21T04:03:11.563", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:14.060", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055124/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2489" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 22:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a R6100 versiones anteriores a la versi\u00f3n 1.0.1.22, R7500 versiones anteriores a la versi\u00f3n 1.0.0.122, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21166", "lastModified": "2024-11-21T04:03:03.883", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T22:15:12.507", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055193/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3167" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21220", "lastModified": "2024-11-21T04:03:12.643", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:14.403", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055117/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2481" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.30, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21188", "lastModified": "2024-11-21T04:03:07.670", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.487", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055169/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2607" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055169/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2607" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 19:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21174", "lastModified": "2024-11-21T04:03:05.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T19:15:12.527", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055184/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2625" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055184/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2625" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 22:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk20_firmware | * | |
netgear | rbk20 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk40_firmware | * | |
netgear | rbk40 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03798255-94BA-427C-8B2D-0861CD5FF730", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9D54BE2-47EB-48F1-A6D0-FB0A2F5094C4", "versionEndExcluding": "1.0.2.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D7800 versiones anteriores a 1.0.1.44, DM200 versiones anteriores a 1.0.0.58, R7800 versiones anteriores a 1.0.2. 58, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK40 versiones anteriores a 2.3.0. 28, RBS40 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1. 0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68." } ], "id": "CVE-2019-20752", "lastModified": "2024-11-21T04:39:16.207", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T22:15:12.727", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060967/Security-Advisory-for-Site-Stored-Cross-Scripting-on-Some-Gateways-Routers-and-WiFi-Systems-PSV-2018-0250" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060967/Security-Advisory-for-Site-Stored-Cross-Scripting-on-Some-Gateways-Routers-and-WiFi-Systems-PSV-2018-0250" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by CSRF. This affects D1500 before 1.0.0.25, D500 before 1.0.0.25, D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, EX6100v2 before 1.0.1.60, EX6150v2 before 1.0.1.60, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.16, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.18, R6020 before 1.0.0.26, R6050 before 1.0.1.16, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6220 before 1.1.0.60, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3700v5 before 1.1.0.48, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.46, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "638CC87A-8459-4878-9985-80B8CF8A1B8D", "versionEndExcluding": "1.0.0.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "78DC8809-C26D-48D8-9E12-228C3669B824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "086445B7-C353-4EE7-8799-3CDC2C3A0E64", "versionEndExcluding": "1.0.0.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d500:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CE070E3-C0B1-455F-83A9-5C60C489816F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7", "versionEndExcluding": "1.0.0.55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A94DD9D-0F07-4FD7-B1B0-1DD1E319B092", "versionEndExcluding": "1.0.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E957C14F-0073-48A9-A78B-A3A36C48F6C2", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E8B1526-CE4F-4ACC-B668-36AA69EA0A34", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E90EB0CF-D659-435C-8BDD-379286F0351A", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A7E7F98-C500-48A9-A1F2-86C3AF7130D6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8EEBDA31-7845-4598-8E40-63CEF5037E84", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6754FA98-E862-4C0B-9146-E858B15B0AE6", "versionEndExcluding": "1.0.0.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF013048-DE20-49A5-9091-DD0DEA830D33", "versionEndExcluding": "1.0.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "10757AA0-970A-4C71-9085-D797A9906861", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D70F5F17-5134-47AB-B182-321B1B0CD72B", "versionEndExcluding": "1.0.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14253C3A-712C-4A7E-83C4-88A6BBEF0AB2", "versionEndExcluding": "1.1.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AB52FC6-BC09-41ED-BB91-63A4E795E0F8", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD1F416B-C938-4AE3-B93E-03087575FF40", "versionEndExcluding": "1.1.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "978E12D1-8C55-4BF2-8213-DE9C23B23EFC", "versionEndExcluding": "1.1.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "51F31B60-7B0F-41AC-9FEF-FAAD54269194", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57B186F2-4D0D-44BD-9F5F-DC1D9FD12C5A", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55A6E04A-1630-4C5F-8173-B6B725A59D46", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects D1500 before 1.0.0.25, D500 before 1.0.0.25, D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, EX6100v2 before 1.0.1.60, EX6150v2 before 1.0.1.60, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.16, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.18, R6020 before 1.0.0.26, R6050 before 1.0.1.16, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6220 before 1.1.0.60, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.40, WNDR3700v5 before 1.1.0.48, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.46, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo CSRF. Esto afecta a D1500 versiones anteriores a 1.0.0.25, D500 versiones anteriores a 1.0.0.25, D6100 versiones anteriores a 1.0.0.55, D7000 versiones anteriores a 1.0.1.50, D7800 versiones anteriores a 1.0.1.28, EX6100v2 versiones anteriores a 1.0.1.60, EX6150v2 versiones anteriores a 1.0.1.60, JNR1010v2 versiones anteriores a 1.1.0.46, JR6150 versiones anteriores a 1.0.1.16, JWNR2010v5 versiones anteriores a 1.1.0.46, PR2000 versiones anteriores a 1.0.0.18, R6020 versiones anteriores a 1.0.0.26, R6050 versiones anteriores a 1.0.1.16, R6080 versiones anteriores a 1.0.0.26, R6100 versiones anteriores a 1.0.1.20, R6220 versiones anteriores a 1.1.0.60, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.40, WNDR3700v5 versiones anteriores a 1.1.0.48, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0. 0.48, WNR1000v4 versiones anteriores a 1.1.0.46, WNR2000v5 versiones anteriores a 1.0.0.62, WNR2020 versiones anteriores a 1.1.0.46 y WNR2050 versiones anteriores a 1.1.0.46." } ], "id": "CVE-2017-18703", "lastModified": "2024-11-21T03:20:42.307", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:12.537", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053199/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0736" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053199/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0736" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 21:15
Modified
2024-11-21 04:02
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6700 before 1.0.1.48, R7500 before 1.0.0.124, R7800 before 1.0.2.58, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5-R2000 before 1.0.0.68.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "732F20CF-135F-4CBF-988F-215B534994B1", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6EA8492-4A15-420E-B616-F93CC36EF255", "versionEndExcluding": "1.0.0.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9D54BE2-47EB-48F1-A6D0-FB0A2F5094C4", "versionEndExcluding": "1.0.2.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6700 before 1.0.1.48, R7500 before 1.0.0.124, R7800 before 1.0.2.58, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5-R2000 before 1.0.0.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a R6700 versiones anteriores a 1.0.1.48, R7500 versiones anteriores a 1.0.0.124, R7800 versiones anteriores a 1.0.2.58, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56, WNDR4500v3 versiones anteriores a 1.0.0.56 y WNR2000v5-R2000 versiones anteriores a 1.0.0.68." } ], "id": "CVE-2018-21135", "lastModified": "2024-11-21T04:02:59.120", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T21:15:11.453", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060225/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3165" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060225/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3165" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | ex8000_firmware | * | |
netgear | ex8000 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048", "versionEndExcluding": "1.0.1.180", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6000 before 1.0.0.75, D6100 before 1.0.0.63, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3100RPv2 before 1.0.0.60, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1. 76, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7300 versiones anteriores a 1.0.2.136, EX8000 versiones anteriores a 1.0.1.180, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0. 4.2, R9000 versiones anteriores a 1.0.4.2, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR3700v4 versiones anteriores a 1.0.2. 102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20689", "lastModified": "2024-11-21T04:39:05.370", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:23.307", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0132" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061450/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0132" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects R6100 before 1.0.1.20, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects R6100 before 1.0.1.20, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a R6100 versiones anteriores a 1.0.1.20, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21203", "lastModified": "2024-11-21T04:03:10.033", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.387", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055146/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2589" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055146/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2589" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 20:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by SQL injection. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6200 before 1.1.00.28, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DC112A before 1.0.0.40, EX8000 before 1.0.0.118, JR6150 before 1.0.1.18, R6050 before 1.0.1.18, R6220 before 1.1.0.66, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900v2 before 1.2.0.16, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500 before 1.0.0.118, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.6, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D55132B3-B7CF-4BB9-B28B-406136D0C97B", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5E3F3F-237F-4ADD-8853-CEBE78AAAC36", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B305E585-0F19-41E0-A6D1-01BBB1AA6DA1", "versionEndExcluding": "1.1.00.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8AA0851-BFD5-45F6-9673-CA4B83D8B844", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD763D04-70A0-4A50-8866-330B82703680", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82EB2B81-08D9-4C81-B6DE-8D1FCAEC485A", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "061389AF-C8DA-48DF-8D7E-014A9B8D5D09", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5E70AF3-FFD8-4ACD-9F4C-DB03BFB1125A", "versionEndExcluding": "1.0.3.39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7587473-93CA-4998-9D73-0E936E425F23", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E176AD5-23F8-4AF8-9BF4-44E065954A57", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC9C60BB-2E7F-4D35-9348-8D8AEFAAD75F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDB0CD0A-A68D-4EF5-A938-6A15604C9107", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "426CB7BF-AE12-4C39-A9F3-86B91383779B", "versionEndExcluding": "1.1.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D1A9B6F-89B2-4785-A0E2-3FD322D6A28F", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "110B10A0-1969-4FDE-9289-6EAB81D1657B", "versionEndExcluding": "1.0.4.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "9597966A-B13C-4098-838B-EC9AA8DE443D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB86B739-440E-4269-92EC-F7F3058E4406", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E4EAD37-164F-4631-8DED-AB9BD41D2429", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCDB34-EC1F-43A1-AA7D-BF4CA1F4C168", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1E1F23B-5E81-4BBE-B161-EE9EA4783979", "versionEndExcluding": "1.2.0.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36871A5D-AC19-43AC-96AD-20F8FB5E2D47", "versionEndExcluding": "1.2.0.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC9FF3EB-EEBA-45C5-B6D6-98D9F0B5ECA2", "versionEndExcluding": "1.2.0.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71BAC6A-F08E-4015-9A54-3CF5FDF85950", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5352DD0A-3388-423C-B6E3-38FFF8B4700F", "versionEndExcluding": "1.0.9.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CB1E644-FB4B-443B-B9D7-349F0024FB74", "versionEndExcluding": "1.3.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EFFC911D-B2A3-47D7-940A-76978458CEA5", "versionEndExcluding": "1.3.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "999A4F9A-D803-47D0-94F5-4626669D8DE0", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0C9AB4A-497B-4D5C-93E3-430C3361E24F", "versionEndExcluding": "1.0.2.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72C46066-B210-44BB-9219-14B2E8CCEF8E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B19B770D-4660-4B12-8B5C-B689DA8CCB64", "versionEndExcluding": "1.3.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2DDFF20-B761-4E45-9F16-CE15C82AAB5C", "versionEndExcluding": "1.3.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E4D2E75-1ADA-4ECE-B1B5-12E28913063E", "versionEndExcluding": "1.0.2.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16C3369B-3E65-4CB7-BFF0-5052DBB16C45", "versionEndExcluding": "1.0.2.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3139F80C-6E20-471E-B1AE-66022D411460", "versionEndExcluding": "1.0.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "832B6460-9984-4441-8E06-F784052FC8CC", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by SQL injection. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6200 before 1.1.00.28, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DC112A before 1.0.0.40, EX8000 before 1.0.0.118, JR6150 before 1.0.1.18, R6050 before 1.0.1.18, R6220 before 1.1.0.66, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900v2 before 1.2.0.16, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500 before 1.0.0.118, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.6, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n SQL. Esto afecta a D3600 versiones anteriores a 1.0.0.68, D6000 versiones anteriores a 1.0.0.68, D6200 versiones anteriores a 1.1.00.28, D6220 versiones anteriores a 1.0.0.40, D6400 versiones anteriores a 1.0.0. 74, D7000 versiones anteriores a 1.0.1.60, D7000v2 versiones anteriores a 1.0.0.74, D7800 versiones anteriores a 1.0.1.34, D8500 versiones anteriores a 1.0.3.39, DC112A versiones anteriores a 1.0.0.40, EX8000 versiones anteriores a 1.0.0. 118, JR6150 versiones anteriores a 1.0.1.18, R6050 versiones anteriores a 1.0.1.18, R6220 versiones anteriores a 1.1.0.66, R6250 versiones anteriores a 1.0.4.26, R6300v2 versiones anteriores a 1.0.4.24, R6400 versiones anteriores a 1.0. 1.36, R6400v2 versiones anteriores a 1.0.2.52, R6700 versiones anteriores a 1.0.1.44, R6700v2 versiones anteriores a 1.2.0.16, R6800 versiones anteriores a 1.2.0.16, R6900v2 versiones anteriores a 1.2.0.16, R6900 versiones anteriores a 1. 0.1.44, R7000 versiones anteriores a 1.0.9.26, R6900P versiones anteriores a 1.3.0.20, R7000P versiones anteriores a 1.3.0.20, R7100LG versiones anteriores a 1.0.0.40, R7300DST versiones anteriores a 1.0.0. 62, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.40, R7900 versiones anteriores a 1.0.2.10, R8000 versiones anteriores a 1.0.4.12, R7900P versiones anteriores a 1.3. 0.10, R8000P versiones anteriores a 1.3.0.10, R8300 versiones anteriores a 1.0.2.116, R8500 versiones anteriores a 1.0.2.116, R8900 versiones anteriores a 1.0.3.6, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1. 0.2.102, WNDR3700v5 versiones anteriores a 1.1.0.54, WNDR4300v1 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.56, y WNDR4500v3 versiones anteriores a 1.0.0.56." } ], "id": "CVE-2019-20730", "lastModified": "2024-11-21T04:39:12.447", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 4.2, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T20:15:13.337", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061197/Security-Advisory-for-SQL-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3056" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061197/Security-Advisory-for-SQL-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3056" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1.78, JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47DB7AAC-5EE3-4912-A44F-C9D5BF42B01C", "versionEndExcluding": "1.0.0.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "78DC8809-C26D-48D8-9E12-228C3669B824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B5A5FCA-6198-4DF7-B395-F266C2B6270C", "versionEndExcluding": "1.0.0.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d500:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CE070E3-C0B1-455F-83A9-5C60C489816F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8AA0851-BFD5-45F6-9673-CA4B83D8B844", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD763D04-70A0-4A50-8866-330B82703680", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82EB2B81-08D9-4C81-B6DE-8D1FCAEC485A", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5E70AF3-FFD8-4ACD-9F4C-DB03BFB1125A", "versionEndExcluding": "1.0.3.39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA60A85-77FF-41BF-89FA-7EB3ACFECDB8", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5C27C8A-1B80-47CD-B015-14588F4F8732", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C309FEFF-5FB1-41BB-B9C5-97CFAC29892C", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B79CB764-3B62-4C39-9B68-A7C949EA91BE", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72C578B9-6D52-492F-854F-067EB36F84B1", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "520E4E2B-FF48-4B11-8A41-975B1A5E9FA2", "versionEndExcluding": "1.0.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "02E7CA7E-E6CA-4BAB-8F40-4731EA523D91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4707A6F6-9586-47FF-8E1A-55D950D8CE19", "versionEndExcluding": "1.0.2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB84CD03-765C-4D4F-A176-364F8E72A4E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AC81E61-E8CD-4929-A1E2-C1B620BCC3E7", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09C02A78-A382-43A0-A20F-D6521F6DD57F", "versionEndExcluding": "1.0.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5E1BEB0-8AA0-423B-A0A2-966341402819", "versionEndExcluding": "1.0.0.34_1.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "46452E97-9347-4788-9570-1EECECC7255E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1C96EDAD-1985-4AB7-9FF1-C67A5D274C99", "versionEndExcluding": "1.0.3.82_1.1.117", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66120328-5681-46E5-86A5-CAC62B9243B9", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "274A58AC-3E28-411B-8495-2ADD184CFAE6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "974F3120-1A73-4301-A720-E31C9C27B41C", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0005DB1D-49BA-4099-89DC-5B4C9AA8BF6F", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B5D8AD4-6C67-4DC7-99DF-B29DBA4BC376", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D0FEB73-5572-48DE-86BE-055364878989", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E111C4B-C1D5-403A-A35F-D538E16D0E23", "versionEndExcluding": "1.0.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB4D669D-D6C4-403E-896D-55EE4EEB7C27", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2DD089FE-0DBF-4C3B-AA02-3A0A27CF9D76", "versionEndExcluding": "1.0.4.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E43DA92A-E429-459F-8B34-DDED55F5590B", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9A5FD9A-5AE9-46A2-A1E6-C7BF84EFAD22", "versionEndExcluding": "1.0.2.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC332E60-A7DB-41C5-B1ED-FE3EDF83F8BC", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D21ACC48-8B3D-4A0B-BA04-C9709835A66A", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "819CC65F-F5DA-4620-BC68-CAAA2B73195D", "versionEndExcluding": "1.0.9.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0EE8EBA-C4CD-4CA1-A684-54338B1254A9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE1B60E4-C8FA-4094-9F05-1746A01557D9", "versionEndExcluding": "1.0.2.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B72579C-51F1-4F16-8FDE-544229C25B07", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7393D4D7-F607-423E-917E-FE520D7A3A73", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAAB159C-27F2-4645-9FE4-4DBB4465DE3A", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A79D8A77-4555-4B2A-8F19-F69AD4A17D2E", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058BC554-8E48-460E-A305-B5CDA8249B28", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07CEF0FF-41A1-485B-8CDA-DB7AE8ECDB69", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "1C4C1B98-9551-4862-AEAC-3D5C313BD275", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAFDAF9A-711E-497F-8632-0345B635A7C9", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF8551B9-72D9-46B8-9F66-EE7841E29A26", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "832B6460-9984-4441-8E06-F784052FC8CC", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6880E178-51E5-47DD-8DE6-59EFDAE4FA0C", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4130E37C-5B30-46E5-90B0-A7D5E163DF02", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C4DA2EE-628D-4F25-9B7E-0F77762139B0", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1.78, JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D1500 versiones anteriores a 1.0.0.27, D500 versiones anteriores a 1.0.0.27, D6100 versiones anteriores a 1.0.0.57, D6220 versiones anteriores a 1.0.0.40, D6400 versiones anteriores a 1.0.0.74, D7000 versiones anteriores a 1.0.1.60, D7800 versiones anteriores a 1.0.1.34, D8500 versiones anteriores a 1.0.3.39, DGN2200v4 versiones anteriores a 1.0.0.94, DGN2200Bv4 versiones anteriores a 1.0.0.94, EX2700 versiones anteriores a 1.0.1.42, EX3700 versiones anteriores a 1.0.0.64, EX3800 versiones anteriores a 1.0.0.64, EX6000 versiones anteriores a 1.0.0.24, EX6100 versiones anteriores a 1.0.2.18, EX6120 versiones anteriores a 1.0.0.32, EX6130 versiones anteriores a 1.0.0.22, EX6150 versiones anteriores a 1.0.0.34_1.0.70, EX6200 versiones anteriores a 1.0.3.82_1.1.117, EX6400 versiones anteriores a 1.0.1.78, EX7000 versiones anteriores a 1.0.0.56, EX7300 versiones anteriores a 1.0.1.78, JNR1010v2 versiones anteriores a 1.1.0.42, JR6150 versiones anteriores a 1.0. 1.10, JWNR2010v5 versiones anteriores a 1.1.0.42, PR2000 versiones anteriores a 1.0.0.22, R6050 versiones anteriores a 1.0.1.10, R6100 versiones anteriores a 1.0.1.16, R6220 versiones anteriores a 1.1.0.50, R6250 versiones anteriores a 1.0.4.14, R6300v2 versiones anteriores a 1.0.4.12, R6400v2 versiones anteriores a 1.0.2.34, R6700 versiones anteriores a 1.0.1.26, R6900 versiones anteriores a 1.0.1.26, R6900P versiones anteriores a 1.2.0.22, R7000 versiones anteriores a 1.0.9.6, R7000P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.40, R7300DST versiones anteriores a 1.0.0.54, R7500 versiones anteriores a 1.0.0.110, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.44, R7900 versiones anteriores a 1.0.1.26, R8000 versiones anteriores a 1.0.3.48, R8300 versiones anteriores a 1.0.2.104, R8500 versiones anteriores a 1.0.2.104, R9000 versiones anteriores a 1.0.3.10, WN2000RPTv3 versiones anteriores a 1.0.1.26, WN2500RPv2 versiones anteriores a 1.0 .1.46, WN3000RPv3 versiones anteriores a 1.0.2.66, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3400v3 versiones anteriores a 1.0.1.14, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR3700v5 versiones anteriores a 1.1.0.54, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48, WNR1000v4 versiones anteriores a 1.1.0.42, WNR2000v5 versiones anteriores a 1.0.0.64, WNR2020 versiones anteriores a 1.1.0.42 y WNR2050 versiones anteriores a 1.1.0.42." } ], "id": "CVE-2018-21231", "lastModified": "2024-11-21T04:03:14.407", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.1, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:13.003", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055103/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0102" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055103/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0102" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 17:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21223", "lastModified": "2024-11-21T04:03:13.120", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T17:15:12.993", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055114/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2457" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 21:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21142", "lastModified": "2024-11-21T04:03:00.197", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T21:15:11.750", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059491/Security-Advisory-for-Denial-of-Service-on-Some-Routers-PSV-2017-3169" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 21:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.40, R7500v2 before 1.0.3.34, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.3.16, RAX120 before 1.0.0.74, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBK40 before 2.3.0.22, RBS40 before 2.3.0.22, SRK60 before 2.2.0.64, SRR60 before 2.2.0.64, SRS60 before 2.2.0.64, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5 before 1.0.0.66.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "600F0894-2001-4681-8B7C-AE24B3C81EA4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B722D956-799F-4A5D-9C4B-5EE2349DB17E", "versionEndExcluding": "1.0.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DF79787-9BE5-4B8F-A243-FE638936D377", "versionEndExcluding": "1.0.3.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93C7D5A8-3B1D-4DCD-ACB6-8629CE598C25", "versionEndExcluding": "1.0.3.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79E7E940-B043-40A7-9347-331DF006656E", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "712E83F9-2AC9-45B1-B0D6-E780CB8D9365", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850B682D-1D78-489A-8988-5D588EB975AC", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B0AB512-7926-4D78-87A2-FFBD56F7D2CA", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F58362EC-24C5-4EC3-9475-328469DABFD2", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B49E5051-D9AF-4852-8BDF-6F9C61CB5519", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F1FE395-0B10-4AA8-A178-D87E93CFA5D5", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BF2AEEF3-EB66-48D5-A39D-675D7093F5A2", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8517632E-5C50-4A30-A9EE-7205A014619F", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9523D09C-0039-4449-8741-0EF066547B0E", "versionEndExcluding": "2.2.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCC347EB-699E-4626-A944-2D378101DDCF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C60C13B-937F-4278-A7D8-465B2E59664D", "versionEndExcluding": "2.2.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "55E6F589-04DA-431C-9E03-BA2A59BB0E4A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9204657B-18EE-4E6F-A7B5-3A1F65E20352", "versionEndExcluding": "2.2.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFB01247-A20F-41CA-8718-E8E60E7F14B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F3D02E3-8FA1-4129-A4B2-25235AF0E49C", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.40, R7500v2 before 1.0.3.34, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.3.16, RAX120 before 1.0.0.74, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBK40 before 2.3.0.22, RBS40 before 2.3.0.22, SRK60 before 2.2.0.64, SRR60 before 2.2.0.64, SRS60 before 2.2.0.64, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, and WNR2000v5 before 1.0.0.66." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.58, D7800 versiones anteriores a 1.0.1.40, R7500v2 versiones anteriores a 1.0.3.34, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1. 0.3.16, RAX120 versiones anteriores a 1.0.0.74, RBK20 versiones anteriores a 2.3.0.22, RBR20 versiones anteriores a 2.3.0.22, RBS20 versiones anteriores a 2.3.0.22, RBK50 versiones anteriores a 2.3.0.22, RBR50 versiones anteriores a 2.3. 0,22, RBS50 versiones anteriores a 2.3.0.22, RBK40 versiones anteriores a 2.3.0.22, RBS40 versiones anteriores a 2.3.0.22, SRK60 versiones anteriores a 2.2.0.64, SRR60 versiones anteriores a 2.2.0.64, SRS60 versiones anteriores a 2.2.0. 64, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56, WNDR4500v3 versiones anteriores a 1.0.0.56, y WNR2000v5 versiones anteriores a 1.0.0.66." } ], "id": "CVE-2019-20747", "lastModified": "2024-11-21T04:39:15.360", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T21:15:12.817", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060962/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0032" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060962/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0032" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 14:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "442F153C-737B-44D4-9A6D-EB6F6C47B986", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F70E0C-3674-4981-B815-0721F6C6E588", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una capacidad del atacante para leer archivos arbitrarios. Esto afecta a D7800 versiones anteriores a la versi\u00f3n 1.0.1.28, R6700 versiones anteriores a la versi\u00f3n 1.0.1.36, R6900 versiones anteriores a la versi\u00f3n 1.0.1.34, R7500v2 versiones anteriores a la versi\u00f3n 1.0.3.20, R7800 versiones anteriores a la versi\u00f3n 1.0.2.40, R9000 versiones anteriores a la versi\u00f3n 1.0.2.52, WNDR4300v2 versiones anteriores a la versi\u00f3n 1.0.0.48, y WNDR4500v3 versiones anteriores a la versi\u00f3n 1.0.0.48." } ], "id": "CVE-2017-18713", "lastModified": "2024-11-21T03:20:43.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T14:15:12.937", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053135/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0114" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053135/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0114" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1., JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47DB7AAC-5EE3-4912-A44F-C9D5BF42B01C", "versionEndExcluding": "1.0.0.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "78DC8809-C26D-48D8-9E12-228C3669B824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B5A5FCA-6198-4DF7-B395-F266C2B6270C", "versionEndExcluding": "1.0.0.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d500:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CE070E3-C0B1-455F-83A9-5C60C489816F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8AA0851-BFD5-45F6-9673-CA4B83D8B844", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD763D04-70A0-4A50-8866-330B82703680", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82EB2B81-08D9-4C81-B6DE-8D1FCAEC485A", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5E70AF3-FFD8-4ACD-9F4C-DB03BFB1125A", "versionEndExcluding": "1.0.3.39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA60A85-77FF-41BF-89FA-7EB3ACFECDB8", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5C27C8A-1B80-47CD-B015-14588F4F8732", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C309FEFF-5FB1-41BB-B9C5-97CFAC29892C", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B79CB764-3B62-4C39-9B68-A7C949EA91BE", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72C578B9-6D52-492F-854F-067EB36F84B1", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "520E4E2B-FF48-4B11-8A41-975B1A5E9FA2", "versionEndExcluding": "1.0.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "02E7CA7E-E6CA-4BAB-8F40-4731EA523D91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4707A6F6-9586-47FF-8E1A-55D950D8CE19", "versionEndExcluding": "1.0.2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB84CD03-765C-4D4F-A176-364F8E72A4E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AC81E61-E8CD-4929-A1E2-C1B620BCC3E7", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09C02A78-A382-43A0-A20F-D6521F6DD57F", "versionEndExcluding": "1.0.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5E1BEB0-8AA0-423B-A0A2-966341402819", "versionEndExcluding": "1.0.0.34_1.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "46452E97-9347-4788-9570-1EECECC7255E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1C96EDAD-1985-4AB7-9FF1-C67A5D274C99", "versionEndExcluding": "1.0.3.82_1.1.117", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66120328-5681-46E5-86A5-CAC62B9243B9", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "274A58AC-3E28-411B-8495-2ADD184CFAE6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07099566-F207-43C4-BCB0-09468E249888", "versionEndExcluding": "1.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0005DB1D-49BA-4099-89DC-5B4C9AA8BF6F", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B5D8AD4-6C67-4DC7-99DF-B29DBA4BC376", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D0FEB73-5572-48DE-86BE-055364878989", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E111C4B-C1D5-403A-A35F-D538E16D0E23", "versionEndExcluding": "1.0.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB4D669D-D6C4-403E-896D-55EE4EEB7C27", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2DD089FE-0DBF-4C3B-AA02-3A0A27CF9D76", "versionEndExcluding": "1.0.4.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E43DA92A-E429-459F-8B34-DDED55F5590B", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9A5FD9A-5AE9-46A2-A1E6-C7BF84EFAD22", "versionEndExcluding": "1.0.2.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC332E60-A7DB-41C5-B1ED-FE3EDF83F8BC", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D21ACC48-8B3D-4A0B-BA04-C9709835A66A", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "819CC65F-F5DA-4620-BC68-CAAA2B73195D", "versionEndExcluding": "1.0.9.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0EE8EBA-C4CD-4CA1-A684-54338B1254A9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE1B60E4-C8FA-4094-9F05-1746A01557D9", "versionEndExcluding": "1.0.2.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B72579C-51F1-4F16-8FDE-544229C25B07", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7393D4D7-F607-423E-917E-FE520D7A3A73", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAAB159C-27F2-4645-9FE4-4DBB4465DE3A", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A79D8A77-4555-4B2A-8F19-F69AD4A17D2E", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058BC554-8E48-460E-A305-B5CDA8249B28", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07CEF0FF-41A1-485B-8CDA-DB7AE8ECDB69", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "1C4C1B98-9551-4862-AEAC-3D5C313BD275", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAFDAF9A-711E-497F-8632-0345B635A7C9", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF8551B9-72D9-46B8-9F66-EE7841E29A26", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "832B6460-9984-4441-8E06-F784052FC8CC", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6880E178-51E5-47DD-8DE6-59EFDAE4FA0C", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4130E37C-5B30-46E5-90B0-A7D5E163DF02", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C4DA2EE-628D-4F25-9B7E-0F77762139B0", "versionEndExcluding": "1.1.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.57, D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX2700 before 1.0.1.42, EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6100 before 1.0.2.18, EX6120 before 1.0.0.32, EX6130 before 1.0.0.22, EX6150 before 1.0.0.34_1.0.70, EX6200 before 1.0.3.82_1.1.117, EX6400 before 1.0.1.78, EX7000 before 1.0.0.56, EX7300 before 1.0.1., JNR1010v2 before 1.1.0.42, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.42, PR2000 before 1.0.0.22, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R6250 before 1.0.4.14, R6300v2 before 1.0.4.12, R6400v2 before 1.0.2.34, R6700 before 1.0.1.26, R6900 before 1.0.1.26, R6900P before 1.2.0.22, R7000 before 1.0.9.6, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, R7300DST before 1.0.0.54, R7500 before 1.0.0.110, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.1.26, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN2500RPv2 before 1.0.1.46, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR3700v5 before 1.1.0.54, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.42, WNR2000v5 before 1.0.0.64, WNR2020 before 1.1.0.42, and WNR2050 before 1.1.0.42." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D1500 versiones anteriores a 1.0.0.27, D500 versiones anteriores a 1.0.0.27, D6100 versiones anteriores a 1.0.0.57, D6220 versiones anteriores a 1.0.0.40, D6400 versiones anteriores a 1.0.0.74, D7000 versiones anteriores a 1.0.1.60, D7800 versiones anteriores a 1.0.1.34, D8500 versiones anteriores a 1.0.3.39, DGN2200v4 versiones anteriores a 1.0.0.94, DGN2200Bv4 versiones anteriores a 1.0.0.94, EX2700 versiones anteriores a 1.0.1.42, EX3700 versiones anteriores a 1.0.0.64, EX3800 versiones anteriores a 1.0.0.64, EX6000 versiones anteriores a 1.0.0.24, EX6100 versiones anteriores a 1.0.2.18, EX6120 versiones anteriores a 1.0.0.32, EX6130 versiones anteriores a 1.0.0.22, EX6150 versiones anteriores a 1.0.0.34_1.0.70, EX6200 versiones anteriores a 1.0.3.82_1.1.117, EX6400 versiones anteriores a 1.0.1.78, EX7000 versiones anteriores a 1.0.0.56, EX7300 versiones anteriores a 1.0.1., JNR1010v2 versiones anteriores a 1.1.0.42, JR6150 versiones anteriores a 1.0 .1.10, JWNR2010v5 versiones anteriores a 1.1.0.42, PR2000 versiones anteriores a 1.0.0.22, R6050 versiones anteriores a 1.0.1.10, R6100 versiones anteriores a 1.0.1.16, R6220 versiones anteriores a 1.1.0.50, R6250 versiones anteriores a 1.0.4.14, R6300v2 versiones anteriores a 1.0.4.12, R6400v2 versiones anteriores a 1.0.2.34 , R6700 versiones anteriores a 1.0.1.26, R6900 versiones anteriores a 1.0.1.26, R6900P versiones anteriores a 1.2.0.22, R7000 versiones anteriores a 1.0.9.6, R7000P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.40, R7300DST versiones anteriores a 1.0.0.54, R7500 versiones anteriores a 1.0.0.110, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.44, R7900 versiones anteriores a 1.0.1.26, R8000 versiones anteriores a 1.0.3.48, R8300 versiones anteriores a 1.0.2.104, R8500 versiones anteriores a 1.0.2.104, R9000 versiones anteriores a 1.0.3.10, WN2000RPTv3 versiones anteriores a 1.0.1.26, WN2500RPv2 versiones anteriores a 1.0 .1.46, WN3000RPv3 versiones anteriores a 1.0.2.66, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3400v3 versiones anteriores a 1.0.1.14, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR3700v5 versiones anteriores a 1.1.0.54, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48, WNR1000v4 versiones anteriores a 1.1.0.42, WNR2000v5 versiones anteriores a 1.0.0.64, WNR2020 versiones anteriores a 1.1.0.42 y WNR2050 versiones anteriores a 1.1.0.42." } ], "id": "CVE-2018-21230", "lastModified": "2024-11-21T04:03:14.210", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.1, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:12.957", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055104/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0117" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055104/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0117" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1. 0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21211", "lastModified": "2024-11-21T04:03:11.257", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.950", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055138/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2491" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055138/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2491" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 22:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects DGN2200v1 before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.78, D6220 before 1.0.0.44, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900 before 1.0.2.16, R7000P before 1.3.2.34, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.2.34, R7000 before 1.0.9.28, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.50.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "99288EE6-3A88-4134-992D-148868117AFC", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v1:*:*:*:*:*:*:*", "matchCriteriaId": "F50D834B-D7B3-43D6-8072-8992FBC8C97B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "629E89E8-F329-4D11-9652-540752084DD3", "versionEndExcluding": "1.0.3.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52FB0300-0FC9-4797-BACB-84D7D932A386", "versionEndExcluding": "1.0.0.51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7AD596B6-3D11-456F-8BD0-2E7153BA5F53", "versionEndExcluding": "1.0.0.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "114EDC62-9DAE-45D9-8A90-A533BBBF50EB", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jndr3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07C1E707-AB63-4812-9BBC-7267AD17BFF9", "versionEndExcluding": "1.0.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jndr3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DEEEEE5-0798-450E-BF9D-B17A15235C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C5FC237-F74C-4771-B5D3-36CF245C0396", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4CA2B4B5-ED8D-476F-9F6E-630B43A38E27", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB84CB9C-DA5C-4D18-9A54-375DD091D932", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "471E4F42-7114-4A7F-832D-2E9222BD25B4", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6CA65438-6431-4169-8CB3-3F19996C4F74", "versionEndExcluding": "1.3.2.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94B3A9D8-A276-41B2-B7BF-7DA58B879A9B", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E59E66D2-7E73-45C8-8D3E-FE589CDBECA4", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A107B2DF-069F-4B11-8272-DB1630A3E985", "versionEndExcluding": "1.3.2.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577AD463-2E99-4D07-BF12-1D40AC88B3FC", "versionEndExcluding": "1.0.9.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08FF0010-66E3-485C-A22B-39E57E738550", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E821B01-31C8-4766-BAAF-D814336617B9", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "203541F7-8AC5-436A-808E-935B03B00E8D", "versionEndExcluding": "1.0.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "741413AB-9519-4BBE-BEDB-DFA2077BAF79", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "502055F1-F919-4C91-A3D0-B144027BC690", "versionEndExcluding": "1.0.4.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D1A9B6F-89B2-4785-A0E2-3FD322D6A28F", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "46D1F73B-1AE0-40AE-BED7-CAE3C7EFEE3B", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EEBD4A-4734-4F43-B7D4-39D81C83A873", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "182CD45B-F4DB-43E4-9E4C-AADAFD2ECAD8", "versionEndExcluding": "1.2.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects DGN2200v1 before 1.0.0.58, D8500 before 1.0.3.42, D7000v2 before 1.0.0.51, D6400 before 1.0.0.78, D6220 before 1.0.0.44, JNDR3000 before 1.0.0.24, R8000 before 1.0.4.18, R8500 before 1.0.2.122, R8300 before 1.0.2.122, R7900 before 1.0.2.16, R7000P before 1.3.2.34, R7300DST before 1.0.0.68, R7100LG before 1.0.0.46, R6900P before 1.3.2.34, R7000 before 1.0.9.28, R6900 before 1.0.1.46, R6700 before 1.0.1.46, R6400v2 before 1.0.2.56, R6400 before 1.0.1.42, R6300v2 before 1.0.4.28, R6250 before 1.0.4.26, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, and WNR3500Lv2 before 1.2.0.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a DGN2200v1 versiones anteriores a 1.0.0.58, D8500 versiones anteriores a 1.0.3.42, D7000v2 versiones anteriores a 1.0.0.51, D6400 versiones anteriores a 1.0.0.78, D6220 versiones anteriores a 1.0.0.44, JNDR3000 versiones anteriores a 1. 0.0.24, R8000 versiones anteriores a 1.0.4.18, R8500 versiones anteriores a 1.0.2.122, R8300 versiones anteriores a 1.0.2.122, R7900 versiones anteriores a 1.0.2.16, R7000P versiones anteriores a 1.3.2.34, R7300DST versiones anteriores a 1.0.0. 68, R7100LG versiones anteriores a 1.0.0.46, R6900P versiones anteriores a 1.3.2.34, R7000 versiones anteriores a 1.0.9.28, R6900 versiones anteriores a 1.0.1.46, R6700 versiones anteriores a 1.0.1.46, R6400v2 versiones anteriores a 1.0.2. 56, R6400 versiones anteriores a 1.0.1.42, R6300v2 versiones anteriores a 1.0.4.28, R6250 versiones anteriores a 1.0.4.26, WNDR3400v3 versiones anteriores a 1.0.1.22, WNDR4500v2 versiones anteriores a 1.0.0.72, y WNR3500Lv2 versiones anteriores a 1.2.0.50." } ], "id": "CVE-2019-20753", "lastModified": "2024-11-21T04:39:16.390", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T22:15:12.790", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060629/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0085" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060629/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0085" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "25525299-DB5C-4A90-B2AA-725ADE58D63C", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7800 versiones anteriores a 1.0.2.40, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21191", "lastModified": "2024-11-21T04:03:08.137", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.660", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055166/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2604" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055166/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2604" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, EX6100v2 before 1.0.1.50, EX6150v2 before 1.0.1.50, EX6200v2 before 1.0.1.44, EX6400 before 1.0.1.60, EX7300 before 1.0.1.60, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.2.30, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6F7E8DD-97B2-4B74-8DBA-FF8F64FAA904", "versionEndExcluding": "1.0.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C053D02-7636-4C2E-A6C0-69C50CBD2EB0", "versionEndExcluding": "1.0.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F842864-3FAC-4F97-BC55-7B5AA73437D6", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4684219C-634D-4147-B1E9-CB736FF41A36", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4EB53B93-A502-4C92-830A-B0C968070AC7", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "228D2C78-E876-4E4C-A5E2-FB215B0917E2", "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD73BEE6-58BC-4FC9-98B9-43E1E32EE366", "versionEndExcluding": "1.0.2.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, EX6100v2 before 1.0.1.50, EX6150v2 before 1.0.1.50, EX6200v2 before 1.0.1.44, EX6400 before 1.0.1.60, EX7300 before 1.0.1.60, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.2.30, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, EX6100v2 versiones anteriores a 1.0.1.50, EX6150v2 versiones anteriores a 1.0.1.50, EX6200v2 versiones anteriores a 1.0.1.44, EX6400 versiones anteriores a 1.0.1.60, EX7300 versiones anteriores a 1.0.1.60, R6100 versiones anteriores a 1.0.1.16, R7500 versiones anteriores a 1.0.0.110, R7800 versiones anteriores a 1.0.2.32, R9000 versiones anteriores a 1.0.2.30, WN3000RPv3 versiones anteriores a 1.0.2.50, WNDR4300v2 versiones anteriores a 1.0.0.50 y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21228", "lastModified": "2024-11-21T04:03:13.907", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:12.817", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0607" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-0607" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D7000 before 1.0.1.52, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "327F762B-1F65-4DE0-B05C-1AAC64974A14", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D555F0B-AABE-4AB7-884B-BBB8E807ECC9", "versionEndExcluding": "1.0.1.31", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C88AE720-9506-446F-A0AD-0B5ADFF1BB21", "versionEndExcluding": "1.0.3.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E90EB0CF-D659-435C-8BDD-379286F0351A", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E61E9642-91C9-4CA8-BB93-0DE1FEFF48BC", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8EEBDA31-7845-4598-8E40-63CEF5037E84", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDFB6345-0D0D-4586-9899-2438AADDCD3F", "versionEndExcluding": "1.0.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9886E8AE-A8D3-46E3-95E6-6EEAA2B6B581", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14253C3A-712C-4A7E-83C4-88A6BBEF0AB2", "versionEndExcluding": "1.1.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE68337A-BA04-424A-8DFC-EEE06400D60F", "versionEndExcluding": "1.1.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DBDE97EB-05FE-475E-8A4E-13C97E91548A", "versionEndExcluding": "1.0.2.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D20223D6-9BC2-40CA-9783-2DE0F5F12F64", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E4EF1D0-C132-443E-B7FB-BE050F825D5B", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1088BCE7-C53C-424F-8041-6404D42922F4", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F7508FAE-C117-4E21-8D3D-0016E25363DB", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F889C021-1D38-4A7B-94B4-78FE47699827", "versionEndExcluding": "1.1.4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93CD0427-0CE9-4F1C-933D-0FE6B5626FAC", "versionEndExcluding": "1.1.4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAAB159C-27F2-4645-9FE4-4DBB4465DE3A", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A79D8A77-4555-4B2A-8F19-F69AD4A17D2E", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "026C640E-7594-4B5A-BDF9-FAB1CD135A47", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "055A63BF-1787-4B72-8416-B6F77025F738", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5025770E-D9D0-4FB6-BE29-1F48EDC31AF1", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26E7527-682C-4145-8AE3-F44661285514", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29839E12-4949-49EA-B396-968BB832AE8D", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "51F31B60-7B0F-41AC-9FEF-FAAD54269194", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57B186F2-4D0D-44BD-9F5F-DC1D9FD12C5A", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55A6E04A-1630-4C5F-8173-B6B725A59D46", "versionEndExcluding": "1.1.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D7000 before 1.0.1.52, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial. Esto afecta a D7000 versiones anteriores a 1.0.1.52, D7800 versiones anteriores a 1.0.1.31, D8500 versiones anteriores a 1.0.3.36, JNR1010v2 versiones anteriores a 1.1.0.46, JR6150 versiones anteriores a 1.0.1.14, JWNR2010v5 versiones anteriores a 1.1.0.46, PR2000 versiones anteriores a 1.0.0.20, R6050 versiones anteriores a 1.0.1.14, R6220 versiones anteriores a 1.1.0.60, R6400 versiones anteriores a 1.1.0.26, R6400v2 versiones anteriores a 1.0.2.46, R6700v2 versiones anteriores a 1.2.0.2, R6800 versiones anteriores a 1.2.0.2, R6900v2 versiones anteriores a 1.2.0.2, R7300DST versiones anteriores a 1.0.0.56, R7500 versiones anteriores a 1.0.0.112, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.36, R7900P versiones anteriores a 1.1.4.6, R8000P versiones anteriores a 1.1.4.6, R8300 versiones anteriores a 1.0.2.104, R8500 versiones anteriores a 1.0.2.104, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.94, WNDR3700v5 versiones anteriores a 1.1. 0.50, WNDR4300 versiones anteriores a 1.0.2.96, WNDR4300v2 versiones anteriores a 1.0.0.52, WNDR4500v3 versiones anteriores a 1.0.0.52, WNR1000v4 versiones anteriores a 1.1.0.46, WNR2020 versiones anteriores a 1.1.0.46 y WNR2050 versiones anteriores a 1.1.0.46." } ], "id": "CVE-2018-21168", "lastModified": "2024-11-21T04:03:04.213", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.730", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055190/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3059" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055190/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-Gateways-and-Extenders-PSV-2017-3059" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 21:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by reflected XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.8, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk20_firmware | * | |
netgear | rbk20 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk40_firmware | * | |
netgear | rbk40 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03798255-94BA-427C-8B2D-0861CD5FF730", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9D54BE2-47EB-48F1-A6D0-FB0A2F5094C4", "versionEndExcluding": "1.0.2.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "00486628-82C7-40F7-B649-1682BBEA484A", "versionEndExcluding": "1.0.4.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by reflected XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7800 before 1.0.2.58, R8900 before 1.0.4.12, R9000 before 1.0.4.8, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBS40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS reflejado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D7800 versiones anteriores a 1.0.1.44, DM200 versiones anteriores a 1.0.0.58, R7800 versiones anteriores a 1.0.2. 58, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.8, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK40 versiones anteriores a 2.3.0. 28, RBS40 versiones anteriores a 2.3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1. 0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68." } ], "id": "CVE-2019-20746", "lastModified": "2024-11-21T04:39:15.160", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.2, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T21:15:12.767", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060973/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0252" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060973/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0252" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 16:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by CSRF. This affects JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | jnr1010_firmware | * | |
netgear | jnr1010 | v2 | |
netgear | jr6150_firmware | * | |
netgear | jr6150 | - | |
netgear | jwnr2010_firmware | * | |
netgear | jwnr2010 | v5 | |
netgear | r6050_firmware | * | |
netgear | r6050 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r6220_firmware | * | |
netgear | r6220 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v5 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr1000_firmware | * | |
netgear | wnr1000 | v4 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | wnr2020_firmware | * | |
netgear | wnr2020 | - | |
netgear | wnr2050_firmware | * | |
netgear | wnr2050 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC9E7939-E195-44AB-8880-D0BCF26BF2E0", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B5D8AD4-6C67-4DC7-99DF-B29DBA4BC376", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34429B2B-D8CB-4BEC-B5FA-5C7F8AC9A1FE", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB4D669D-D6C4-403E-896D-55EE4EEB7C27", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1664969-D326-4EC5-BF0D-E43820CCB378", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD1F416B-C938-4AE3-B93E-03087575FF40", "versionEndExcluding": "1.1.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5684DEA-5F12-4E72-B8D1-C5F3E1D22726", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36CCD48D-4474-4363-8DE6-846714B99D3D", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436026D2-0B8E-4BA5-AD34-9EB285EDA78A", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, R6050 before 1.0.1.10, R6100 before 1.0.1.16, R6220 before 1.1.0.50, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo CSRF. Esto afecta a JNR1010v2 versiones anteriores a 1.1.0.44, JR6150 versiones anteriores a 1.0.1.10, JWNR2010v5 versiones anteriores a 1.1.0.44, R6050 versiones anteriores a 1.0.1.10, R6100 versiones anteriores a 1.0.1.16, R6220 versiones anteriores a 1.1.0.50, R7500 versiones anteriores a 1.0.0.112, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.36, R9000 versiones anteriores a 1.0.2.40, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR3700v5 versiones anteriores a 1.1.0.48, WNDR4300 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48, WNR1000v4 versiones anteriores a 1.1.0.44, WNR2 1.0.0.58, WNR2020 versiones anteriores a 1.1.0.44 y WNR2050 versiones anteriores a 1.1.0.44." } ], "id": "CVE-2017-18749", "lastModified": "2024-11-21T03:20:49.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T16:15:12.993", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051505/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-PSV-2016-0101" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 16:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.16, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.16, R7500 versiones anteriores a 1.0.0.112, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.36, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48 y WNDR4500v3 versiones anteriores a 1.0.0.48." } ], "id": "CVE-2017-18751", "lastModified": "2024-11-21T03:20:50.027", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T16:15:13.103", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051503/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2517" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051503/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2517" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21219", "lastModified": "2024-11-21T04:03:12.487", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:14.373", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055118/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2482" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 17:15
Modified
2024-11-21 02:45
Severity ?
Summary
Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac1450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32794415-73D5-4C63-BCAB-FA324BBCE850", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac1450:-:*:*:*:*:*:*:*", "matchCriteriaId": "E4BA18B2-8234-4C26-B865-741D467C5EBE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:c6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DC0FCBB-5F1B-417C-8E4B-FBD403CF2E38", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:c6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7185DE0B-B15C-417D-9AF5-FBF15F9C2241", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56141687-D086-4EEE-9F8A-C238CC26854E", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "78DC8809-C26D-48D8-9E12-228C3669B824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B175146A-AA48-4A89-9712-E87BBB0B389F", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD7FA616-CD66-488A-92ED-3F28954F9E45", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d500:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CE070E3-C0B1-455F-83A9-5C60C489816F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D53F8CC0-F707-4F98-85CE-9A816BE39809", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D349BA3-DF82-4DD5-BDA6-6AB5F3B70BD3", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F22E4FA5-DB96-4946-86B1-0D18A3BEBB2A", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DFEBB6A6-EABA-4A04-8B49-3C9F64D7C5C6", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200b:-:*:*:*:*:*:*:*", "matchCriteriaId": "60FAC76D-96D6-41FB-8EE8-C25F3CBB3307", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2EC71979-23F7-4623-BE4A-82713E95DACD", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "78542C95-85CC-43E5-9F0E-B12DDD5B79C4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6300b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "357F14D2-06B8-4BA5-9D7E-B334F59C7250", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6300b:-:*:*:*:*:*:*:*", "matchCriteriaId": "37B89703-CAFB-43F6-8880-90349F8ED856", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEFBB234-2155-45F8-933D-93E89EC1F54F", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn1000:v3:*:*:*:*:*:*:*", "matchCriteriaId": "430497AE-7C43-400E-9C70-001B2DA23B67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "769065AA-BC73-4674-87B0-3D514FEFDBEF", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v1:*:*:*:*:*:*:*", "matchCriteriaId": "F50D834B-D7B3-43D6-8072-8992FBC8C97B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "769065AA-BC73-4674-87B0-3D514FEFDBEF", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v3:*:*:*:*:*:*:*", "matchCriteriaId": "509F9F22-24E7-45E9-AB96-17F8B50813F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "769065AA-BC73-4674-87B0-3D514FEFDBEF", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5158CF4D-80FC-44FD-B9DA-442FA3A1A913", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v3:*:*:*:*:*:*:*", "matchCriteriaId": "8A4EE9AB-F3DE-4EA8-8344-7F62288EC921", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5158CF4D-80FC-44FD-B9DA-442FA3A1A913", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgnd3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696689E8-E4C4-4A92-9D00-4C6B8CA80448", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgnd3700:v1:*:*:*:*:*:*:*", "matchCriteriaId": "8A5971C6-2F27-4715-BC9E-378B647611D8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgnd3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "696689E8-E4C4-4A92-9D00-4C6B8CA80448", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgnd3700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "7A8F0B8E-D3F2-43C9-8B12-43DE4226E826", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgnd3700b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E607B102-4151-4829-B5D5-779D096D620F", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgnd3700b:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C6F2634F-EA5A-48CE-91BA-964C0B40AF8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F19C07A-65D3-4FFF-9D11-58C2B4D7A531", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v1:*:*:*:*:*:*:*", "matchCriteriaId": "B4196FE8-4491-442C-96A0-23495165D3B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F19C07A-65D3-4FFF-9D11-58C2B4D7A531", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr3300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5738544-7D8A-45AD-99F3-6F92C6886ACD", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr3300:-:*:*:*:*:*:*:*", "matchCriteriaId": "64CA12CC-48D8-4510-983C-8350A87CD5D2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30751D8C-301D-4C9F-8512-E887512CE388", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "2C1C81B4-033E-4F44-9D17-27B04FCF8EF4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AF8ACF6-2BDF-49C2-B92F-2207D83664BF", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86B79A3A-8A63-4BD5-9016-8C98AEF737A8", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "3D78543E-37A7-4829-9165-D0CF52DD4867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D0BCC15-918E-4A31-A943-C5B72CB117E9", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B1D13C3-5663-447F-9FD9-71EBEC471DAF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "675EBB75-3DB8-45D7-9512-5D297C680750", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "067085C6-EA5C-430B-B81E-A5809BD047B0", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ECBBDBEC-C896-4130-933B-150DB17662A3", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8A466B29-3ADA-46D9-824C-8DF9160B7DD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ECBBDBEC-C896-4130-933B-150DB17662A3", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "719248B0-BE22-4836-A23E-FE9F7590FB0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "717CDDCB-3DEB-4949-AAC8-D939D01A0858", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "760BD171-837C-4D36-A4AF-551E926B53C0", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC7F9A44-CC92-4E00-A274-ADA08469F33F", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:-:*:*:*:*:*:*:*", "matchCriteriaId": "9597966A-B13C-4098-838B-EC9AA8DE443D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC7F9A44-CC92-4E00-A274-ADA08469F33F", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66DBD436-0DA8-4917-99EB-6A5D0C3D42D1", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D2356B7-389D-4612-8DBE-00C6AC35BD3D", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9866D7B9-622A-4B25-8CFA-D31AB4406A4F", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BC36898-99C5-4755-9C42-687EAC07013B", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1BBF5B80-58EB-467E-8E07-6CB6C2E88BBC", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wgr614_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A746A6A7-AFD5-41DC-B805-C1526CFD2E95", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wgr614:v10:*:*:*:*:*:*:*", "matchCriteriaId": "B47B0897-A9B9-4568-84DD-C3CE0118B439", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2BF93E7-2E14-48C7-BD1A-9C5FC3451334", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "25187765-6842-4F6A-BF5E-B2E634A958A0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2BF93E7-2E14-48C7-BD1A-9C5FC3451334", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v3:*:*:*:*:*:*:*", "matchCriteriaId": "A239B4C0-0CD9-4632-A1E3-68B8E39692B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17D010FA-275D-4D34-8DB8-49BEA70AF6DA", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58CC514B-1570-4116-9E1F-289BD9DD5935", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58CC514B-1570-4116-9E1F-289BD9DD5935", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3BC4526-3FCE-42D3-B34A-C32060B78AF7", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v1:*:*:*:*:*:*:*", "matchCriteriaId": "829C71CF-A1E7-456E-8230-8929BD7E867C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3BC4526-3FCE-42D3-B34A-C32060B78AF7", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3BC4526-3FCE-42D3-B34A-C32060B78AF7", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "938F4D22-AEFC-4141-BC1C-101F835D4E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v3:*:*:*:*:*:*:*", "matchCriteriaId": "91D091D4-04EA-4564-A2CC-88E217A9FC08", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17B45AE0-0FBF-478B-966F-B2B28C971C3C", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCA254A9-B22D-44C5-9261-19AFBD2B2EE4", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C547734B-BF1A-4CD9-8FD8-9ECB3D15B0BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCA254A9-B22D-44C5-9261-19AFBD2B2EE4", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "D2913468-C442-48A3-8AD9-A2F3CCDD7952", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCA254A9-B22D-44C5-9261-19AFBD2B2EE4", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BFCD5179-4D17-4187-BFFD-7FF080804D95", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2200:-:*:*:*:*:*:*:*", "matchCriteriaId": "94B74E4A-3E2F-4CB1-B33D-8618ED1C7E9F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF1CD0F5-D109-460F-9417-1907A6368A8B", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA9EF618-6194-4127-BD60-FB0E645C8993", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDBCEE9B-9189-42DA-86D1-3FF6E4168127", "versionEndExcluding": "2017-01-06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password exposure. This affects AC1450 before 2017-01-06, C6300 before 2017-01-06, D500 before 2017-01-06, D1500 before 2017-01-06, D3600 before 2017-01-06, D6000 before 2017-01-06, D6100 before 2017-01-06, D6200 before 2017-01-06, D6200B before 2017-01-06, D6300B before 2017-01-06, D6300 before 2017-01-06, DGN1000v3 before 2017-01-06, DGN2200v1 before 2017-01-06, DGN2200v3 before 2017-01-06, DGN2200V4 before 2017-01-06, DGN2200Bv3 before 2017-01-06, DGN2200Bv4 before 2017-01-06, DGND3700v1 before 2017-01-06, DGND3700v2 before 2017-01-06, DGND3700Bv2 before 2017-01-06, JNR1010v1 before 2017-01-06, JNR1010v2 before 2017-01-06, JNR3300 before 2017-01-06, JR6100 before 2017-01-06, JR6150 before 2017-01-06, JWNR2000v5 before 2017-01-06, R2000 before 2017-01-06, R6050 before 2017-01-06, R6100 before 2017-01-06, R6200 before 2017-01-06, R6200v2 before 2017-01-06, R6220 before 2017-01-06, R6250 before 2017-01-06, R6300 before 2017-01-06, R6300v2 before 2017-01-06, R6700 before 2017-01-06, R7000 before 2017-01-06, R7900 before 2017-01-06, R7500 before 2017-01-06, R8000 before 2017-01-06, WGR614v10 before 2017-01-06, WNR1000v2 before 2017-01-06, WNR1000v3 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2000v3 before 2017-01-06, WNR2000v4 before 2017-01-06, WNR2000v5 before 2017-01-06, WNR2200 before 2017-01-06, WNR2500 before 2017-01-06, WNR3500Lv2 before 2017-01-06, WNDR3400v2 before 2017-01-06, WNDR3400v3 before 2017-01-06, WNDR3700v3 before 2017-01-06, WNDR3700v4 before 2017-01-06, WNDR3700v5 before 2017-01-06, WNDR4300 before 2017-01-06, WNDR4300v2 before 2017-01-06, WNDR4500v1 before 2017-01-06, WNDR4500v2 before 2017-01-06, and WNDR4500v3 before 2017-01-06." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por una exposici\u00f3n de contrase\u00f1as. Esto afecta a AC1450 hasta el 06-01-2017, C6300 hasta el 06-01-2017, D500 hasta el 06-01-2017, D1500 hasta el 06-01-2017, D3600 hasta el 06-01-2017, D6000 hasta el 06-01-2017, D6100 hasta el 06-01-2017, D6200 hasta el 06-01-2017, D6200B hasta el 06-01-2017, D6300B hasta el 06-01-2017, D6300 hasta el 06-01-2017, DGN1000v3 hasta el 06-01-2017, DGN2200v1 hasta el 06-01-2017, DGN2200v3 hasta el 06-01-2017, DGN2200V4 hasta el 06-01-2017, DGN2200Bv3 hasta el 06-01-2017, DGN2200Bv4 hasta el 06-01-2017, DGND3700v1 hasta el 06-01-2017, DGND3700v2 hasta el 06-01-2017, DGND3700Bv2 hasta el 06-01-2017, JNR1010v1 hasta el 06-01-2017, JNR1010v2 hasta el 06-01-2017, JNR3300 hasta el 06-01-2017, JR6100 hasta el 06-01-2017, JR6150 hasta el 06-01-2017, JWNR2000v5 hasta el 06-01-2017, R2000 hasta el 06-01-2017, R6050 hasta el 06-01-2017, R6100 hasta el 06-01-2017, R6200 hasta el 06-01-2017, R6200v2 hasta el 06-01-2017, R6220 hasta el 06-01-2017, R6250 hasta el 06-01-2017, R6300 hasta el 06-01-2017, R6300v2 hasta el 06-01-2017, R6700 hasta el 06-01-2017, R7000 hasta el 06-01-2017, R7900 hasta el 06-01-2017, R7500 hasta el 06-01-2017, R8000 hasta el 06-01-2017, WGR614v10 hasta el 06-01-2017, WNR1000v2 hasta el 06-01-2017, WNR1000v3 hasta el 06-01-2017, WNR1000v4 hasta el 06-01-2017, WNR2000v3 hasta el 06-01-2017, WNR2000v4 hasta el 06-01-2017, WNR2000v5 hasta el 06-01-2017, WNR2200 hasta el 06-01-2017, WNR2500 hasta el 06-01-2017, WNR3500Lv2 hasta el 06-01-2017, WNDR3400v2 hasta el 06-01-2017, WNDR3400v3 hasta el 06-01-2017, WNDR3700v3 hasta el 06-01-2017, WNDR3700v4 hasta el 06-01-2017, WNDR3700v5 hasta el 06-01-2017, WNDR4300 hasta el 06-01-2017, WNDR4300v2 hasta el 06-01-2017, WNDR4500v1 hasta el 06-01-2017, WNDR4500v2 hasta el 06-01-2017, and WNDR4500v3 hasta el 06-01-2017." } ], "id": "CVE-2016-11059", "lastModified": "2024-11-21T02:45:24.220", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T17:15:12.460", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/27253/NETGEAR-Product-Vulnerability-Advisory-Authentication-Bypass-and-Information-Disclosure-on-Home-Routers" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.0.54, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | - | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E9F459C-B628-402A-AF4A-72E08FE41837", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.0.54, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, DM200 versiones anteriores a 1.0.0.50, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.0.54, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21149", "lastModified": "2024-11-21T04:03:01.247", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.107", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059484/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3156" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059484/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3156" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R7500v2 before 1.0.3.20, R7800 before 1.0.2.38, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D2BC6CC-CEB1-4580-8555-82F6A4CDFA14", "versionEndExcluding": "1.0.2.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R7500v2 before 1.0.3.20, R7800 before 1.0.2.38, WN3000RPv3 before 1.0.2.50, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.38, WN3000RPv3 versiones anteriores a 1.0.2.50, WNDR4300v2 versiones anteriores a 1.0.0.50 y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21229", "lastModified": "2024-11-21T04:03:14.067", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 1.6, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:12.880", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055105/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0124" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055105/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0124" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D6100 before V1.0.0.55, D7000 before V1.0.1.50, D7800 before V1.0.1.24, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, R6100 before 1.0.1.12, R6220 before 1.1.0.50, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.40, WNR2000v5 before 1.0.0.42, WNR2020 before 1.1.0.40, and WNR2050 before 1.1.0.40.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7000_firmware | * | |
netgear | d7000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | jnr1010_firmware | * | |
netgear | jnr1010 | v2 | |
netgear | jwnr2010_firmware | * | |
netgear | jwnr2010 | v5 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r6220_firmware | * | |
netgear | r6220 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr1000_firmware | * | |
netgear | wnr1000 | v4 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | wnr2020_firmware | * | |
netgear | wnr2020 | - | |
netgear | wnr2050_firmware | * | |
netgear | wnr2050 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7", "versionEndExcluding": "1.0.0.55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A94DD9D-0F07-4FD7-B1B0-1DD1E319B092", "versionEndExcluding": "1.0.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3197737-90A5-411B-8F3D-902D7FD3CEB6", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B13F80BA-F4DF-4728-8591-CDEEE82BDF9E", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52C2DA42-3B95-43B4-AB3B-103607B44C33", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D3B299C-B097-4287-B250-DA6488970976", "versionEndExcluding": "1.0.1.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F05A673D-1AA7-4DDA-A00C-EBC353777417", "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B635B7C8-01C3-4C4F-B0FD-1B826801214B", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E6E8DBB-487E-45DE-990D-AF193F05BA97", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18CB70FD-790E-4342-962A-2C9D8991B3C1", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3B5B30F-0159-48B6-BC8D-BF8F2EE519D6", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "764C3E34-DDED-4530-A314-0D99226B9E1C", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "013EA9F3-64C4-4F06-989D-D00D86CF555F", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects D6100 before V1.0.0.55, D7000 before V1.0.1.50, D7800 before V1.0.1.24, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, R6100 before 1.0.1.12, R6220 before 1.1.0.50, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.40, WNR2000v5 before 1.0.0.42, WNR2020 before 1.1.0.40, and WNR2050 before 1.1.0.40." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a D6100 versiones anteriores a V1.0.0.55, D7000 versiones anteriores a V1.0.1.50, D7800 versiones anteriores a V1.0.1.24, JNR1010v2 versiones anteriores a 1.1.0.40, JWNR2010v5 versiones anteriores a 1.1.0.40, R6100 versiones anteriores a 1.0.1.12, R6220 versiones anteriores a 1.1.0.50, R7500 versiones anteriores a 1.0.0.108, R7500v2 versiones anteriores a 1.0.3.10, WNDR4300v1 versiones anteriores a 1.0.2.88, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48, WNR1000v4 versiones anteriores a 1.1.0.40, WNR2000v5 versiones anteriores a 1.0.0.42, WNR2020 versiones anteriores a 1.1.0.50 y WNR2020 versiones anteriores a 1.1.0.50, y WNR2050 versiones anteriores a 1.1.0.40." } ], "id": "CVE-2017-18776", "lastModified": "2024-11-21T03:20:53.340", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.5, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.5, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:12.050", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049552/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-Gateways-PSV-2017-0387" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049552/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-Gateways-PSV-2017-0387" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 14:15
Modified
2024-11-21 03:20
Severity ?
Summary
NETGEAR WNDR4500v3 devices before 1.0.0.48 are affected by denial of service.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "NETGEAR WNDR4500v3 devices before 1.0.0.48 are affected by denial of service." }, { "lang": "es", "value": "Los dispositivos NETGEAR WNDR4500v3 versiones anteriores a la versi\u00f3n 1.0.0.48, est\u00e1n afectados por una denegaci\u00f3n de servicio." } ], "id": "CVE-2017-18714", "lastModified": "2024-11-21T03:20:44.100", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T14:15:12.997", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053134/Security-Advisory-for-Denial-of-Service-on-WNDR4500v3-PSV-2016-0077" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 16:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX6200v2 before 1.0.1.44, R6100 before 1.0.1.12, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, R7800 before 1.0.2.28, R9000 before 1.0.2.30, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F842864-3FAC-4F97-BC55-7B5AA73437D6", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D3B299C-B097-4287-B250-DA6488970976", "versionEndExcluding": "1.0.1.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F05A673D-1AA7-4DDA-A00C-EBC353777417", "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B635B7C8-01C3-4C4F-B0FD-1B826801214B", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1815E034-5CA2-4511-A4BD-9E124AD17F9E", "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD73BEE6-58BC-4FC9-98B9-43E1E32EE366", "versionEndExcluding": "1.0.2.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX6200v2 before 1.0.1.44, R6100 before 1.0.1.12, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, R7800 before 1.0.2.28, R9000 before 1.0.2.30, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a EX6200v2 versiones anteriores a 1.0.1.44, R6100 versiones anteriores a 1.0.1.12, R7500 versiones anteriores a 1.0.0.108, R7500v2 versiones anteriores a 1.0.3.10, R7800 versiones anteriores a 1.0.2.28, R9000 versiones anteriores a 1.0.2.30, WNDR4300v2 versiones anteriores a 1.0.0.48 y WNDR4500v3 versiones anteriores a 1.0.0.48 ." } ], "id": "CVE-2017-18748", "lastModified": "2024-11-21T03:20:49.587", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T16:15:12.930", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051506/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0104" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051506/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Extenders-PSV-2016-0104" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 17:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.16, R7500 before 1.0.0.116, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR4300v2 before 1.0.0.48, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65C14251-4C0A-4C72-803D-25BCAC83159C", "versionEndExcluding": "1.0.0.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1664969-D326-4EC5-BF0D-E43820CCB378", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.16, R7500 before 1.0.0.116, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.40, WNDR4300v2 before 1.0.0.48, WNDR4300v1 before 1.0.2.90, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.16, R7500 versiones anteriores a 1.0.0.116, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.36, R9000 versiones anteriores a 1.0.2.40, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4300v1 versiones anteriores a 1.0.2.90, y WNDR4500v3 versiones anteriores a 1.0.0.48." } ], "id": "CVE-2017-18757", "lastModified": "2024-11-21T03:20:50.843", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.6, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T17:15:11.963", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2016-0120" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 20:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JNDR3000 before 1.0.0.22, R6250 before 1.0.4.26, R6300v2 before 1.0.4.22, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R6900P before 1.3.1.26, R7000P before 1.3.1.26, R7300DST before 1.0.0.62, R7900 before 1.0.2.16, R8000 before 1.0.4.18, R7900P before 1.4.1.42, R8000P before 1.4.1.42, R8300 before 1.0.2.116, R8500 before 1.0.2.116, WNDR3400v3 before 1.0.1.18, WNDR4500v2 before 1.0.0.68, and WNR3500Lv2 before 1.2.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | jndr3000_firmware | * | |
netgear | jndr3000 | - | |
netgear | r6250_firmware | * | |
netgear | r6250 | - | |
netgear | r6300_firmware | * | |
netgear | r6300 | v2 | |
netgear | r6400_firmware | * | |
netgear | r6400 | - | |
netgear | r6400_firmware | * | |
netgear | r6400 | v2 | |
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r7300dst_firmware | * | |
netgear | r7300dst | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | r8300_firmware | * | |
netgear | r8300 | - | |
netgear | r8500_firmware | * | |
netgear | r8500 | - | |
netgear | wndr3400_firmware | * | |
netgear | wndr3400 | v3 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v2 | |
netgear | wnr3500l_firmware | * | |
netgear | wnr3500l | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jndr3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACE7B01B-A02D-4B45-B61C-D61D8CFD52C1", "versionEndExcluding": "1.0.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jndr3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DEEEEE5-0798-450E-BF9D-B17A15235C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D1A9B6F-89B2-4785-A0E2-3FD322D6A28F", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF768B9B-5C16-494F-95E7-F938798A4C5E", "versionEndExcluding": "1.0.4.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB86B739-440E-4269-92EC-F7F3058E4406", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E4EAD37-164F-4631-8DED-AB9BD41D2429", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCDB34-EC1F-43A1-AA7D-BF4CA1F4C168", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71BAC6A-F08E-4015-9A54-3CF5FDF85950", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577AD463-2E99-4D07-BF12-1D40AC88B3FC", "versionEndExcluding": "1.0.9.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03D83FC0-511A-4DEC-9188-962F70495FFF", "versionEndExcluding": "1.3.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6912DF29-6041-4450-8ED8-4AB74EBDB0D7", "versionEndExcluding": "1.3.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "999A4F9A-D803-47D0-94F5-4626669D8DE0", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "471E4F42-7114-4A7F-832D-2E9222BD25B4", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C5FC237-F74C-4771-B5D3-36CF245C0396", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "337E0627-1D8C-4AC8-BF42-7B095FF22B4F", "versionEndExcluding": "1.4.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E1086EA-9B13-4F1D-B483-6AACC9E5E724", "versionEndExcluding": "1.4.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E4D2E75-1ADA-4ECE-B1B5-12E28913063E", "versionEndExcluding": "1.0.2.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16C3369B-3E65-4CB7-BFF0-5052DBB16C45", "versionEndExcluding": "1.0.2.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "38BC0F78-4571-45E6-9023-CD1AEA7DF8EF", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "19595646-15D5-4558-99C9-B562EBC8E71A", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "263DFC40-2EED-49F3-AAA5-0F5D7EAC2DF3", "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JNDR3000 before 1.0.0.22, R6250 before 1.0.4.26, R6300v2 before 1.0.4.22, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R6900P before 1.3.1.26, R7000P before 1.3.1.26, R7300DST before 1.0.0.62, R7900 before 1.0.2.16, R8000 before 1.0.4.18, R7900P before 1.4.1.42, R8000P before 1.4.1.42, R8300 before 1.0.2.116, R8500 before 1.0.2.116, WNDR3400v3 before 1.0.1.18, WNDR4500v2 before 1.0.0.68, and WNR3500Lv2 before 1.2.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a JNDR3000 versiones anteriores a 1.0.0.22, R6250 versiones anteriores a 1.0.4.26, R6300v2 versiones anteriores a 1.0.4.22, R6400 versiones anteriores a 1.0.1.36, R6400v2 versiones anteriores a 1.0.2.52, R6700 versiones anteriores a 1.0.1.44, R6900 versiones anteriores a 1.0.1.44, R7000 versiones anteriores a 1.0.9.28, R6900P versiones anteriores a 1.3.1.26, R7000P versiones anteriores a 1.3.1. 26, R7300DST versiones anteriores a 1.0.0.62, R7900 versiones anteriores a 1.0.2.16, R8000 versiones anteriores a 1.0.4.18, R7900P versiones anteriores a 1.4.1.42, R8000P versiones anteriores a 1.4.1. 42, R8300 versiones anteriores a 1.0.2.116, R8500 versiones anteriores a 1.0.2.116, WNDR3400v3 versiones anteriores a 1.0.1.18, WNDR4500v2 versiones anteriores a 1.0.0.68, y WNR3500Lv2 versiones anteriores a 1.2.0.48." } ], "id": "CVE-2019-20729", "lastModified": "2024-11-21T04:39:12.277", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T20:15:13.273", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061198/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-3120" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-11 00:15
Modified
2024-11-21 06:17
Severity ?
2.4 (Low) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C8A5E09-861A-4C5F-8C0A-96803782E9EF", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33C16A69-C930-4DA3-8750-EB50F2827731", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FCEBCD7-1D0D-47F6-BC72-A53BFBF3662D", "versionEndExcluding": "1.1.00.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F36AC74-11DB-4805-9B73-302F86A8C240", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58E68C65-9685-40E8-8D51-6C922232168B", "versionEndExcluding": "1.0.0.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD73CBDF-0B17-4B1A-8A06-9F3926D1D113", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A0D49BA-4843-4F7E-984A-FF7BDF292F56", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C35893A-C6C2-45C7-B3AF-BCFA62381BE5", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C329B7CB-1281-480D-BDDB-E222044D715E", "versionEndExcluding": "1.0.3.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF9C0E1-7128-4052-B05E-3DD3394208A0", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "373DD028-D307-4B4A-9C35-DDC9366F481F", "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgnd2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "411A0637-1498-4376-B10D-004D096EC4F6", "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgnd2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "D6EBFFCE-0D9E-4383-8CD6-3DC4D2412446", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0864CF6F-C025-44FE-B00F-83E14ACE1F8F", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B760484C-0D85-49BF-AA5D-2DB0A3A5D7E6", "versionEndExcluding": "1.0.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E8357471-53D2-4FCF-85CD-7D4297960841", "versionEndExcluding": "1.0.0.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "02E7CA7E-E6CA-4BAB-8F40-4731EA523D91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "094113E0-3656-4E2A-B9EF-D397296BD07C", "versionEndExcluding": "1.0.2.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB84CD03-765C-4D4F-A176-364F8E72A4E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23EA7CC1-B1E8-431F-B4AF-8393B85F26E3", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18C88DDC-92C2-400E-8269-88A0EA65A98A", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D74896A7-7EF2-41C9-8A29-59B2EA5ABA5C", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v1:*:*:*:*:*:*:*", "matchCriteriaId": "2CB9BD19-E748-41B9-8873-316FEB83F13D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A81A7574-A2C7-4216-98C6-6790FA705013", "versionEndExcluding": "1.0.3.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F1E93FB-4926-4AF5-BA5F-A4DE4314B45F", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048", "versionEndExcluding": "1.0.1.180", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EFF5F80A-5196-4585-9993-6D985561B75E", "versionEndExcluding": "2.1.4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A59BA256-2D2F-4930-9033-D312BA01D1FB", "versionEndExcluding": "2.1.4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD22FA4E-1D05-4A83-9610-731957A96A96", "versionEndExcluding": "2.1.4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14BE7862-3CBB-472E-9339-1435999C57F9", "versionEndExcluding": "2.1.4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2FCEC68E-0BD3-47E6-AD24-EE9076654B86", "versionEndExcluding": "2.1.4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "00C4765D-D903-4967-91D2-11F59458EBCD", "versionEndExcluding": "2.1.4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE0E9E59-4F1F-490B-BCE8-B3690593353B", "versionEndExcluding": "2.2.1.204", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50E2E26A-200E-4D00-9657-034EACE3944F", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27FC1738-5A2C-4D4B-944C-1EB1A8D2476E", "versionEndExcluding": "1.0.0.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "442B71BC-D2D4-4F0F-8962-B50D5E8D2833", "versionEndExcluding": "1.0.0.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDB0CD0A-A68D-4EF5-A938-6A15604C9107", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC9C60BB-2E7F-4D35-9348-8D8AEFAAD75F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "92F53D21-C688-4477-815D-EFFF08F7D085", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "51FC4898-BF35-443A-A003-40351B20ADEC", "versionEndExcluding": "1.1.0.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1DD1F7D-7556-4B95-A33F-E389948D20AA", "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E997B769-B2F7-4BB5-A834-96A68EF842BA", "versionEndExcluding": "1.0.4.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF638167-B018-4140-B115-C65F387EFD77", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91532716-831D-401C-8707-86785F0A4E16", "versionEndExcluding": "1.0.2.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "732F20CF-135F-4CBF-988F-215B534994B1", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A4FB8A1-D380-4234-88EB-91BFF6D215C7", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C39CE79-6433-47E2-A439-9AB1DFBD843C", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6992BA-B0F5-4E00-84F4-0B0336910AFA", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7BAAD2F7-BF0A-412B-BC2E-A69DC9BCB52E", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E453D3AE-A218-4791-BB19-79C2CF6EC6F8", "versionEndExcluding": "1.0.9.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "103B19E9-C72D-43C2-8369-1C425E9B9AC7", "versionEndExcluding": "1.3.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E23D8A41-75D8-4067-A961-3B81276527A8", "versionEndExcluding": "1.3.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B484FA9-17B9-4829-9152-83691EE6A9BB", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F168C3F8-F77C-4918-A752-9A04CED2349E", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845CF217-8361-4D5B-811D-B9CEB68880CB", "versionEndExcluding": "1.0.3.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "98FAEBDA-5FBA-402D-9BA1-25E5DF4EF55F", "versionEndExcluding": "1.0.4.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8BBB7E16-D31C-49EA-9D82-D3BACED95441", "versionEndExcluding": "1.4.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6791754E-E5F9-42EA-AFDA-F93E8227A7C8", "versionEndExcluding": "1.4.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD0AB065-3152-492B-A66D-2BCCA1E3B1DA", "versionEndExcluding": "1.0.2.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28EC6190-68BC-4D9A-9973-01935EB3472F", "versionEndExcluding": "1.0.2.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6160F657-601E-4BDD-949A-D1411F08A8F9", "versionEndExcluding": "2.2.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF38D418-BF9B-4C69-8D05-6D216B487182", "versionEndExcluding": "2.2.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50v:-:*:*:*:*:*:*:*", "matchCriteriaId": "54453B5D-4E51-4DAB-8670-5A99C0D4CE3E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0675F6C4-EB61-4DA3-8473-448E93D5E0A5", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "1C4C1B98-9551-4862-AEAC-3D5C313BD275", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "250E8C27-ED0F-46FC-B630-52E9BF2CA812", "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A480981E-57ED-47E3-B9AB-190E4783DC04", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "46D1F73B-1AE0-40AE-BED7-CAE3C7EFEE3B", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F3D02E3-8FA1-4129-A4B2-25235AF0E49C", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0141851-BE96-4F6A-883F-3B20AE6945C1", "versionEndExcluding": "1.1.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "727F8FD9-692C-4752-9B1E-D6281919061C", "versionEndExcluding": "1.1.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1748207-4BAA-4CC2-AD44-19D895B1C08B", "versionEndExcluding": "1.2.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C031037-5177-4871-9C61-15BC580CC41D", "versionEndExcluding": "2.3.2.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6100 before 1.0.0.63, D6200 before 1.1.00.34, D6220 before 1.0.0.48, D6400 before 1.0.0.86, D7000 before 1.0.1.70, D7000v2 before 1.0.0.52, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.108, DGND2200Bv4 before 1.0.0.108, EX2700 before 1.0.1.48, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6000 before 1.0.0.38, EX6100 before 1.0.2.24, EX6100v2 before 1.0.1.76, EX6120 before 1.0.0.42, EX6130 before 1.0.0.28, EX6150v1 before 1.0.0.42, EX6150v2 before 1.0.1.76, EX6200 before 1.0.3.88, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7000 before 1.0.0.66, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, RBK50 before 2.1.4.10, RBR50 before 2.1.4.10, RBS50 before 2.1.4.10, RBK40 before 2.1.4.10, RBR40 before 2.1.4.10, RBS40 before 2.1.4.10, RBW30 before 2.2.1.204, PR2000 before 1.0.0.28, R6020 before 1.0.0.38, R6080 before 1.0.0.38, R6050 before 1.0.1.18, JR6150 before 1.0.1.18, R6120 before 1.0.0.46, R6220 before 1.1.0.86, R6250 before 1.0.4.34, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.62, R6700 before 1.0.1.48, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R6900 before 1.0.1.48, R7000 before 1.0.9.34, R6900P before 1.3.1.64, R7000P before 1.3.1.64, R7100LG before 1.0.0.48, R7300DST before 1.0.0.70, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R7900 before 1.0.3.8, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R9000 before 1.0.3.10, RBS40V before 2.2.0.58, RBK50V before 2.2.0.58, WN2000RPTv3 before 1.0.1.32, WN2500RPv2 before 1.0.1.54, WN3000RPv3 before 1.0.2.78, WN3100RPv2 before 1.0.0.66, WNDR3400v3 before 1.0.1.22, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR2000v5 (R2000) before 1.0.0.66, WNR2020 before 1.1.0.62, WNR2050 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, and XR500 before 2.3.2.22." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de la autenticaci\u00f3n. Esto afecta a D3600 versiones anteriores a 1.0.0.72, D6000 versiones anteriores a 1.0.0.72, D6100 versiones anteriores a 1.0.0.63, D6200 versiones anteriores a 1.1.00.34, D6220 versiones anteriores a 1.0.0.48, D6400 versiones anteriores a 1.0.0.86, D7000 versiones anteriores a 1.0.1.70, D7000v2 versiones anteriores a 1.0.0.52, D7800 versiones anteriores a 1.0.1.56, D8500 versiones anteriores a 1.0.3.44, DC112A versiones anteriores a 1.0.0.42, DGN8000 versiones anteriores a 1.0.4.98. 0.0.42, DGN2200v4 versiones anteriores a 1.0.0.108, DGND2200Bv4 versiones anteriores a 1.0.0.108, EX2700 versiones anteriores a 1.0.1.48, EX3700 versiones anteriores a 1.0.0.76, EX3800 versiones anteriores a 1.0.0.76, EX6000 versiones anteriores a 1.0.0.38, EX6100 versiones anteriores a 1.0.2.24, EX6100v2 versiones anteriores a 1.0.1.76, EX6120 versiones anteriores a 1.0.0.42, EX6130 versiones anteriores a 1. 0.0.28, EX6150v1 versiones anteriores a 1.0.0.42, EX6150v2 versiones anteriores a 1.0.1.76, EX6200 versiones anteriores a 1.0.3.88, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7000 versiones anteriores a 1.0.0.66, EX7300 versiones anteriores a 1.0.2.136, EX8000 versiones anteriores a 1.0.1.180, RBK50 versiones anteriores a 2.1.4.10, RBR50 versiones anteriores a 2.1.4. 10, RBS50 versiones anteriores a 2.1.4.10, RBK40 versiones anteriores a 2.1.4.10, RBR40 versiones anteriores a 2.1.4.10, RBS40 versiones anteriores a 2.1.4.10, RBW30 versiones anteriores a 2.2.1.204, PR2000 versiones anteriores a 1.0.0.28, R6020 versiones anteriores a 1.0.0.38, R6080 versiones anteriores a 1.0.0.38, R6050 versiones anteriores a 1.0.1.18, JR6150 versiones anteriores a 1.0.1.18, R6120 versiones anteriores a 1.0. 0.46, R6220 versiones anteriores a 1.1.0.86, R6250 versiones anteriores a 1.0.4.34, R6300v2 versiones anteriores a 1.0.4.32, R6400 versiones anteriores a 1.0.1.44, R6400v2 versiones anteriores a 1.0.2. 62, R6700 versiones anteriores a 1.0.1.48, R6700v2 versiones anteriores a 1.2.0.36, R6800 versiones anteriores a 1.2.0.36, R6900v2 versiones anteriores a 1.2.0.36, R6900 versiones anteriores a 1.0.1.48, R7000 versiones anteriores a 1. 0.9.34, R6900P versiones anteriores a 1.3.1.64, R7000P versiones anteriores a 1.3.1.64, R7100LG versiones anteriores a 1.0.0.48, R7300DST versiones anteriores a 1.0.0.70, R7500v2 versiones anteriores a 1. 0.3.38, R7800 versiones anteriores a 1.0.2.52, R7900 versiones anteriores a 1.0.3.8, R8000 versiones anteriores a 1.0.4.28, R7900P versiones anteriores a 1.4.1.30, R8000P versiones anteriores a 1.4.1. 30, R8300 versiones anteriores a 1.0.2.128, R8500 versiones anteriores a 1.0.2.128, R9000 versiones anteriores a 1.0.3.10, RBS40V versiones anteriores a 2.2.0.58, RBK50V versiones anteriores a 2.2.0. 58, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN2500RPv2 versiones anteriores a 1.0.1.54, WN3000RPv3 versiones anteriores a 1.0.2.78, WN3100RPv2 versiones anteriores a 1.0.0.66, WNDR3400v3 versiones anteriores a 1.0. 1.22, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56, WNDR4500v3 versiones anteriores a 1.0.0. 56, WNR2000v5 (R2000) versiones anteriores a 1.0.0.66, WNR2020 versiones anteriores a 1.1.0.62, WNR2050 versiones anteriores a 1.1.0.62, WNR3500Lv2 versiones anteriores a 1.2.0.62 y XR500 versiones anteriores a 2.3.2.22" } ], "id": "CVE-2021-38514", "lastModified": "2024-11-21T06:17:17.693", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 2.4, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 1.4, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-11T00:15:15.663", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063757/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2017-2449" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 14:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una capacidad del atacante para leer archivos arbitrarios. Esto afecta a D7800 versiones anteriores a la versi\u00f3n 1.0.1.28, R6100 versiones anteriores a la versi\u00f3n 1.0.1.20, R7500 versiones anteriores a la versi\u00f3n 1.0.0.118, R7500v2 versiones anteriores a la versi\u00f3n 1.0.3.20, R7800 versiones anteriores a la versi\u00f3n 1.0.2.40, R9000 versiones anteriores a la versi\u00f3n 1.0.2.52, WNDR4300v2 versiones anteriores a la versi\u00f3n 1.0.0.48, y WNDR4500v3 versiones anteriores a la versi\u00f3n 1.0.0.48." } ], "id": "CVE-2017-18712", "lastModified": "2024-11-21T03:20:43.790", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T14:15:12.857", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053136/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0127" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053136/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-and-Gateways-PSV-2016-0127" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-21 22:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, DM200 versiones anteriores a 1.0.0.50, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21145", "lastModified": "2024-11-21T04:03:00.650", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-21T22:15:14.197", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059488/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3160" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059488/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3160" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 20:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6400 before 1.0.0.74, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.102, DGND2200Bv4 before 1.0.0.102, DM200 before 1.0.0.52, JNDR3000 before 1.0.0.22, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, RBW30 before 2.1.2.6, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, WNR2000v5 before 1.0.0.64, and WNR3500Lv2 before 1.2.0.48.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD763D04-70A0-4A50-8866-330B82703680", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "061389AF-C8DA-48DF-8D7E-014A9B8D5D09", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5E70AF3-FFD8-4ACD-9F4C-DB03BFB1125A", "versionEndExcluding": "1.0.3.39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72004304-314A-4BE6-A33E-7F4CDF01FCEF", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgnd2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE696277-6FBD-4345-B372-FA375B0F763B", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgnd2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "D6EBFFCE-0D9E-4383-8CD6-3DC4D2412446", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7DEE689F-923A-414C-B048-E4716DA2B783", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jndr3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACE7B01B-A02D-4B45-B61C-D61D8CFD52C1", "versionEndExcluding": "1.0.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jndr3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DEEEEE5-0798-450E-BF9D-B17A15235C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7ED1541-DE7D-4A4C-B8D1-CB42E52E3DBE", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "094B04D5-9063-4D7A-B367-E1F2688B3667", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C489444C-6C19-4A52-AF66-A1D48ADC4F26", "versionEndExcluding": "2.3.5.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E993AF26-3505-4FD8-8842-F5E613CDDC2E", "versionEndExcluding": "2.1.2.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D1A9B6F-89B2-4785-A0E2-3FD322D6A28F", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "110B10A0-1969-4FDE-9289-6EAB81D1657B", "versionEndExcluding": "1.0.4.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB86B739-440E-4269-92EC-F7F3058E4406", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E4EAD37-164F-4631-8DED-AB9BD41D2429", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCDB34-EC1F-43A1-AA7D-BF4CA1F4C168", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71BAC6A-F08E-4015-9A54-3CF5FDF85950", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5352DD0A-3388-423C-B6E3-38FFF8B4700F", "versionEndExcluding": "1.0.9.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CB1E644-FB4B-443B-B9D7-349F0024FB74", "versionEndExcluding": "1.3.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EFFC911D-B2A3-47D7-940A-76978458CEA5", "versionEndExcluding": "1.3.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "999A4F9A-D803-47D0-94F5-4626669D8DE0", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE1B60E4-C8FA-4094-9F05-1746A01557D9", "versionEndExcluding": "1.0.2.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0C9AB4A-497B-4D5C-93E3-430C3361E24F", "versionEndExcluding": "1.0.2.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72C46066-B210-44BB-9219-14B2E8CCEF8E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B19B770D-4660-4B12-8B5C-B689DA8CCB64", "versionEndExcluding": "1.3.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2DDFF20-B761-4E45-9F16-CE15C82AAB5C", "versionEndExcluding": "1.3.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E4D2E75-1ADA-4ECE-B1B5-12E28913063E", "versionEndExcluding": "1.0.2.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16C3369B-3E65-4CB7-BFF0-5052DBB16C45", "versionEndExcluding": "1.0.2.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "38BC0F78-4571-45E6-9023-CD1AEA7DF8EF", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "263DFC40-2EED-49F3-AAA5-0F5D7EAC2DF3", "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6400 before 1.0.0.74, D7000v2 before 1.0.0.74, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.102, DGND2200Bv4 before 1.0.0.102, DM200 before 1.0.0.52, JNDR3000 before 1.0.0.22, RBK50 before 2.3.5.30, RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, RBW30 before 2.1.2.6, R6250 before 1.0.4.26, R6300v2 before 1.0.4.24, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.26, R6900P before 1.3.0.20, R7000P before 1.3.0.20, R7100LG before 1.0.0.40, R7300DST before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.44, R7900 before 1.0.2.10, R8000 before 1.0.4.12, R7900P before 1.3.0.10, R8000P before 1.3.0.10, R8300 before 1.0.2.116, R8500 before 1.0.2.116, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, WNR2000v5 before 1.0.0.64, and WNR3500Lv2 before 1.2.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta a D6400 versiones anteriores a 1.0.0.74, D7000v2 versiones anteriores a 1.0.0.74, D7800 versiones anteriores a 1.0.1.34, D8500 versiones anteriores a 1.0.3.39, DGN2200v4 versiones anteriores a 1.0.0.102, DGND2200Bv4 versiones anteriores a 1.0.0.102, DM200 versiones anteriores a 1.0.0.52, JNDR3000 versiones anteriores a 1.0.0.22, RBK50 versiones anteriores a 2.3.5.30, RBR50 versiones anteriores a 2.3. 5.30, RBS50 versiones anteriores a 2.3.5.30, RBW30 versiones anteriores a 2.1.2.6, R6250 versiones anteriores a 1.0.4.26, R6300v2 versiones anteriores a 1.0.4.24, R6400 versiones anteriores a 1.0.1. 36, R6400v2 versiones anteriores a 1.0.2.52, R6700 versiones anteriores a 1.0.1.44, R6900 versiones anteriores a 1.0.1.44, R7000 versiones anteriores a 1.0.9.26, R6900P versiones anteriores a 1.3.0.20, R7000P versiones anteriores a 1. 3.0.20, R7100LG versiones anteriores a 1.0.0.40, R7300DST versiones anteriores a 1.0.0.62, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.44, R7900 versiones anteriores a 1.0.2.10, R8000 versiones anteriores a 1.0.4.12, R7900P versiones anteriores a 1.3.0.10, R8000P versiones anteriores a 1.3.0.10, R8300 versiones anteriores a 1.0.2.116, R8500 versiones anteriores a 1.0.2. 116, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3400v3 versiones anteriores a 1.0.1.18, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300v1 versiones anteriores a 1. 0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54, WNR2000v5 versiones anteriores a 1.0.0.64, y WNR3500Lv2 versiones anteriores a 1.2.0.48." } ], "id": "CVE-2019-20728", "lastModified": "2024-11-21T04:39:12.090", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 0.8, "impactScore": 5.5, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T20:15:13.210", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061199/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2017-315" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061199/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2017-315" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 04:02
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.60, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.66.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA3E7329-F839-4DD3-921F-B9E8DEDC8F12", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F3D02E3-8FA1-4129-A4B2-25235AF0E49C", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.60, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.66." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.60, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58 y WNR2000v5 versiones anteriores a 1.0.0.66." } ], "id": "CVE-2018-21111", "lastModified": "2024-11-21T04:02:55.650", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:13.190", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060440/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0115" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060440/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Modem-Routers-PSV-2018-0115" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, D7800 before 1.0.1.44, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk20_firmware | * | |
netgear | rbk20 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, D7800 before 1.0.1.44, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, D7800 versiones anteriores a 1.0.1.44, R7500v2 versiones anteriores a 1.0.3. 38, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0. 28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, RBS40 versiones anteriores a 2.3.0.28, WNDR3700v4 versiones anteriores a 1.0.2. 102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20724", "lastModified": "2024-11-21T04:39:11.433", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.400", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061204/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0144" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061204/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0144" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 20:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a la versi\u00f3n 1.0.1.34, R7500v2 versiones anteriores a la versi\u00f3n 1.0.3.26, R7800 versiones anteriores a la versi\u00f3n 1.0.2.42, R8900 versiones anteriores a la versi\u00f3n 1.0.3.10, R9000 versiones anteriores a la versi\u00f3n 1.0.3.10, WNDR4300v2 versiones anteriores a la versi\u00f3n 1.0.0.54 y WNDR4500v3 versiones anteriores a la versi\u00f3n 1.0.0.54." } ], "id": "CVE-2018-21151", "lastModified": "2024-11-21T04:03:01.560", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T20:15:11.167", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059482/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3154" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059482/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3154" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk20_firmware | * | |
netgear | rbk20 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03798255-94BA-427C-8B2D-0861CD5FF730", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBS40 before 2.3.0.28, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.44, DM200 versiones anteriores a 1.0.0.58, R7500v2 versiones anteriores a 1.0.3.38, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2. 3.0.28, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, RBS40 versiones anteriores a 2.3.0.28, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20722", "lastModified": "2024-11-21T04:39:11.107", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061206/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0148" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061206/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0148" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E460D519-DDF3-4E59-9E41-050DC3723FD7", "versionEndExcluding": "1.0.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, D7800 versiones anteriores a 1.0.1.34, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2. 40, R9000 versiones anteriores a 1.0.3.6, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21194", "lastModified": "2024-11-21T04:03:08.613", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.830", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055163/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2601" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055163/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2601" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R7500v2 before 1.0.3.24, R7800 before 1.0.2.38, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0BCDB34-EC1F-43A1-AA7D-BF4CA1F4C168", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71BAC6A-F08E-4015-9A54-3CF5FDF85950", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "577AD463-2E99-4D07-BF12-1D40AC88B3FC", "versionEndExcluding": "1.0.9.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D2BC6CC-CEB1-4580-8555-82F6A4CDFA14", "versionEndExcluding": "1.0.2.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.28, R6700 before 1.0.1.44, R6900 before 1.0.1.44, R7000 before 1.0.9.28, R7500v2 before 1.0.3.24, R7800 before 1.0.2.38, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.28, R6700 versiones anteriores a 1.0.1.44, R6900 versiones anteriores a 1.0.1.44, R7000 versiones anteriores a 1.0.9.28, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.38, R9000 versiones anteriores a 1.0.2.52, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21157", "lastModified": "2024-11-21T04:03:02.517", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.480", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059473/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-2248" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059473/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-2248" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 16:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r7100lg_firmware | * | |
netgear | r7100lg | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D55132B3-B7CF-4BB9-B28B-406136D0C97B", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5E3F3F-237F-4ADD-8853-CEBE78AAAC36", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD7D570E-C5EF-4D3E-BCCF-926DBDB12016", "versionEndExcluding": "1.0.9.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.68, D6000 versiones anteriores a 1.0.0.68, D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.16, R6900P versiones anteriores a 1.2.0.22, R7000 versiones anteriores a 1.0.9.10, R7000P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.40, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.58." } ], "id": "CVE-2017-18762", "lastModified": "2024-11-21T03:20:51.437", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T16:15:11.373", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21218", "lastModified": "2024-11-21T04:03:12.327", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:14.310", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055119/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2483" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R6400v2 before 1.0.2.34, R6700 before 1.0.1.30, R6900 before 1.0.1.30, R6900P before 1.0.0.62, R7000 before 1.0.9.12, R7000P before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6400_firmware | * | |
netgear | r6400 | v2 | |
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9A5FD9A-5AE9-46A2-A1E6-C7BF84EFAD22", "versionEndExcluding": "1.0.2.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7379D9B1-39FF-4B31-B443-3E15E1E7B122", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F4E70DE3-B7E2-4F51-84E7-045BBCCFAD68", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8704A948-EDD7-4BDE-8B2F-4D6C3C7268B0", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6918A436-BC48-40A0-869F-9F3CFAB2C6E7", "versionEndExcluding": "1.0.9.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68108824-9BA7-4442-B329-72769BD4EA2D", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R6400v2 before 1.0.2.34, R6700 before 1.0.1.30, R6900 before 1.0.1.30, R6900P before 1.0.0.62, R7000 before 1.0.9.12, R7000P before 1.0.0.62, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, R6400v2 versiones anteriores a 1.0.2.34, R6700 versiones anteriores a 1.0.1.30, R6900 versiones anteriores a 1.0.1.30, R6900P versiones anteriores a 1.0.0.62, R7000 versiones anteriores a 1.0.9.12, R7000P versiones anteriores a 1.0.0.62, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.42, R9000 versiones anteriores a 1.0.3.10, WNDR4300v2 versiones anteriores a 1.0.0.50 y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21227", "lastModified": "2024-11-21T04:03:13.760", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T15:15:12.753", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-0737" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-0737" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos de un atacante no autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7500v2 versiones anteriores a 1.0.3.24, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21208", "lastModified": "2024-11-21T04:03:10.797", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.763", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2516" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2516" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1. 0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20726", "lastModified": "2024-11-21T04:39:11.753", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.527", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 16:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.18, R6050 before 1.0.1.10, R6100 before 1.0.1.14, R6120 before 1.0.0.30, R6220 before 1.1.0.50, R6700v2 before 1.2.0.4, R6800 before 1.2.0.4, R6900v2 before 1.2.0.4, R7500 before 1.0.0.110, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7", "versionEndExcluding": "1.0.0.55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A94DD9D-0F07-4FD7-B1B0-1DD1E319B092", "versionEndExcluding": "1.0.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC9E7939-E195-44AB-8880-D0BCF26BF2E0", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B5D8AD4-6C67-4DC7-99DF-B29DBA4BC376", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34429B2B-D8CB-4BEC-B5FA-5C7F8AC9A1FE", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6754FA98-E862-4C0B-9146-E858B15B0AE6", "versionEndExcluding": "1.0.0.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB4D669D-D6C4-403E-896D-55EE4EEB7C27", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E8197CA-84A2-4714-8EBB-04BA4B66ED29", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E91C5BC-8FAB-4D9F-BADB-D6286D531C75", "versionEndExcluding": "1.0.0.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EA5FF68-8609-4692-8DBF-A12606882BE5", "versionEndExcluding": "1.2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A272C3DA-043A-4621-9F16-70F9501FEE46", "versionEndExcluding": "1.2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B89AB47-7117-4FA7-B8F1-36D0C281C403", "versionEndExcluding": "1.2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD1F416B-C938-4AE3-B93E-03087575FF40", "versionEndExcluding": "1.1.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5684DEA-5F12-4E72-B8D1-C5F3E1D22726", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36CCD48D-4474-4363-8DE6-846714B99D3D", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436026D2-0B8E-4BA5-AD34-9EB285EDA78A", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.55, D7000 before 1.0.1.50, D7800 before 1.0.1.28, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.10, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.18, R6050 before 1.0.1.10, R6100 before 1.0.1.14, R6120 before 1.0.0.30, R6220 before 1.1.0.50, R6700v2 before 1.2.0.4, R6800 before 1.2.0.4, R6900v2 before 1.2.0.4, R7500 before 1.0.0.110, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R9000 before 1.0.2.52, WN3000RPv3 before 1.0.2.50, WNDR3700v4 before 1.0.2.88, WNDR3700v5 before 1.1.0.48, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.58, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.55, D7000 versiones anteriores a 1.0.1.50, D7800 versiones anteriores a 1.0.1.28, JNR1010v2 versiones anteriores a 1.1.0.44, JR6150 versiones anteriores a 1.0.1.10, JWNR2010v5 versiones anteriores a 1.1.0.44, PR2000 versiones anteriores a 1.0.0.18, R6050 versiones anteriores a 1.0.1.10, R6100 versiones anteriores a 1.0.1.14, R6120 versiones anteriores a 1.0.0.30, R6220 versiones anteriores a 1.1.0.50, R6700v2 versiones anteriores a 1.2.0.4, R6800 versiones anteriores a 1.2.0.4, R6900v2 versiones anteriores a 1.2.0.4, R7500 versiones anteriores a 1.0.0.110, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.36, R9000 versiones anteriores a 1.0.2.52, WN3000RPv3 versiones anteriores a 1.0.2.50, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR3700v5 versiones anteriores a 1.1.0.48, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48, WNR1000v4 versiones anteriores a 1.1.0.44, WNR2000v5 versiones anteriores a 1.0.0.58, WNR2020 versiones anteriores a 1.1.0.44 y WNR2050 versiones anteriores a 1.1.0.44." } ], "id": "CVE-2017-18764", "lastModified": "2024-11-21T03:20:51.747", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T16:15:11.497", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051481/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2210" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051481/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2210" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 21:15
Modified
2024-11-21 04:02
Severity ?
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.58, D6200 before 1.1.00.30, D6220 before 1.0.0.46, D6400 before 1.0.0.82, D7000 before 1.0.1.68, D7000v2 before 1.0.0.51, D7800 before 1.0.1.42, D8500 before 1.0.3.42, DC112A before 1.0.0.40, DGN2200Bv4 before 1.0.0.102, DGN2200v4 before 1.0.0.102, JNR1010v2 before 1.1.0.54, JR6150 before 1.0.1.18, JWNR2010v5 before 1.1.0.54, PR2000 before 1.0.0.24, R6020 before 1.0.0.34, R6050 before 1.0.1.18, R6080 before 1.0.0.34, R6100 before 1.0.1.22, R6120 before 1.0.0.42, R6220 before 1.1.0.68, R6250 before 1.0.4.30, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.60, R6700 before 1.0.1.48, R6700v2 before 1.2.0.24, R6800 before 1.2.0.24, R6900 before 1.0.1.48, R6900P before 1.3.1.44, R6900v2 before 1.2.0.24, R7000 before 1.0.9.34, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7300 before 1.0.0.68, R7500 before 1.0.0.124, R7500v2 before 1.0.3.38, R7900 before 1.0.2.16, R7900P before 1.4.1.24, R8000 before 1.0.4.18, R8000P before 1.4.1.24, R8300 before 1.0.2.122, R8500 before 1.0.2.122, WN3000RP before 1.0.0.68, WN3000RPv2 before 1.0.0.68, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR1000v4 before 1.1.0.54, WNR2020 before 1.1.0.54, WNR2050 before 1.1.0.54, and WNR3500Lv2 before 1.2.0.54.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47DB7AAC-5EE3-4912-A44F-C9D5BF42B01C", "versionEndExcluding": "1.0.0.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "78DC8809-C26D-48D8-9E12-228C3669B824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B5A5FCA-6198-4DF7-B395-F266C2B6270C", "versionEndExcluding": "1.0.0.27", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d500:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CE070E3-C0B1-455F-83A9-5C60C489816F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "600F0894-2001-4681-8B7C-AE24B3C81EA4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4A922C9-1C6D-4694-AB9F-EDD285FEAA7C", "versionEndExcluding": "1.1.00.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6ABD67D-F08A-4879-A497-EA3DF0A87D4B", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E84B61C3-54CA-4127-AE6B-E63AB51E0C85", "versionEndExcluding": "1.0.0.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D127F467-E2D0-462C-B9E1-458CFFFAC062", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52FB0300-0FC9-4797-BACB-84D7D932A386", "versionEndExcluding": "1.0.0.51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCEAE442-EE2A-4F16-90FD-13369A0C972C", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "629E89E8-F329-4D11-9652-540752084DD3", "versionEndExcluding": "1.0.3.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7587473-93CA-4998-9D73-0E936E425F23", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15616D3A-6741-42CE-926D-171CB231C88D", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72004304-314A-4BE6-A33E-7F4CDF01FCEF", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D6B82D8-DDCE-445C-A0FA-558701021A23", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC9C60BB-2E7F-4D35-9348-8D8AEFAAD75F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9B596F0-BC6F-42CA-A3AD-7E2DD1AD423D", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B03B4F14-ADF8-4316-BEB8-6092A5B94F5D", "versionEndExcluding": "1.0.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "973CBC26-395C-407F-937B-4E9D2DBE282C", "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDB0CD0A-A68D-4EF5-A938-6A15604C9107", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "38FE855A-C695-4D0B-98C8-1D09265F0092", "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C30A626-B5E2-48B1-A659-89E6EB167A8F", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36187C87-B384-4042-8098-39738DB30A6F", "versionEndExcluding": "1.1.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5DE93565-D893-4AB3-83A9-BCEFAF6547E0", "versionEndExcluding": "1.0.4.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E997B769-B2F7-4BB5-A834-96A68EF842BA", "versionEndExcluding": "1.0.4.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF638167-B018-4140-B115-C65F387EFD77", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "903EC8C1-0504-45B8-846C-8E1855A250E3", "versionEndExcluding": "1.0.2.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "732F20CF-135F-4CBF-988F-215B534994B1", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86F0E9CD-7AE4-4D58-828D-E958AC02B2A0", "versionEndExcluding": "1.2.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E30B4AA4-393B-4A84-AB64-3E087D473849", "versionEndExcluding": "1.2.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7BAAD2F7-BF0A-412B-BC2E-A69DC9BCB52E", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52A6DEB2-3A33-4184-866D-9C8D9DD991C6", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E20F6EF-0585-4432-8DCC-29C3B01616CE", "versionEndExcluding": "1.2.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E453D3AE-A218-4791-BB19-79C2CF6EC6F8", "versionEndExcluding": "1.0.9.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90805FFE-E59D-43D2-BF1E-D55458CF05BF", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B484FA9-17B9-4829-9152-83691EE6A9BB", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "586740D8-2423-404C-B5E2-23B273945CCD", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "29B13F94-F151-4F00-95C3-D9FB22B3CC2B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6EA8492-4A15-420E-B616-F93CC36EF255", "versionEndExcluding": "1.0.0.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "471E4F42-7114-4A7F-832D-2E9222BD25B4", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FED192A-8427-4293-850F-42519DBE7521", "versionEndExcluding": "1.4.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C5FC237-F74C-4771-B5D3-36CF245C0396", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1DEFB47-32C4-4AF6-87AF-0C09E8D5CD81", "versionEndExcluding": "1.4.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB84CB9C-DA5C-4D18-9A54-375DD091D932", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4CA2B4B5-ED8D-476F-9F6E-630B43A38E27", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E449BEE1-DFE7-413C-B15E-4E6EE6FB84CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "38BC0F78-4571-45E6-9023-CD1AEA7DF8EF", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "832B6460-9984-4441-8E06-F784052FC8CC", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "35548CE8-3F3B-456D-9E95-A8A2C2E2B247", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "37E56123-6404-4DC8-B2C5-CE89532EFB20", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA48EB08-ABBC-4F42-8877-FF40E475E3A7", "versionEndExcluding": "1.1.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E338A30-C349-41B4-B971-E6D6B0E9AFE4", "versionEndExcluding": "1.2.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects D1500 before 1.0.0.27, D500 before 1.0.0.27, D6100 before 1.0.0.58, D6200 before 1.1.00.30, D6220 before 1.0.0.46, D6400 before 1.0.0.82, D7000 before 1.0.1.68, D7000v2 before 1.0.0.51, D7800 before 1.0.1.42, D8500 before 1.0.3.42, DC112A before 1.0.0.40, DGN2200Bv4 before 1.0.0.102, DGN2200v4 before 1.0.0.102, JNR1010v2 before 1.1.0.54, JR6150 before 1.0.1.18, JWNR2010v5 before 1.1.0.54, PR2000 before 1.0.0.24, R6020 before 1.0.0.34, R6050 before 1.0.1.18, R6080 before 1.0.0.34, R6100 before 1.0.1.22, R6120 before 1.0.0.42, R6220 before 1.1.0.68, R6250 before 1.0.4.30, R6300v2 before 1.0.4.32, R6400 before 1.0.1.44, R6400v2 before 1.0.2.60, R6700 before 1.0.1.48, R6700v2 before 1.2.0.24, R6800 before 1.2.0.24, R6900 before 1.0.1.48, R6900P before 1.3.1.44, R6900v2 before 1.2.0.24, R7000 before 1.0.9.34, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7300 before 1.0.0.68, R7500 before 1.0.0.124, R7500v2 before 1.0.3.38, R7900 before 1.0.2.16, R7900P before 1.4.1.24, R8000 before 1.0.4.18, R8000P before 1.4.1.24, R8300 before 1.0.2.122, R8500 before 1.0.2.122, WN3000RP before 1.0.0.68, WN3000RPv2 before 1.0.0.68, WNDR3400v3 before 1.0.1.18, WNDR3700v4 before 1.0.2.102, WNDR3700v5 before 1.1.0.54, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, WNDR4500v3 before 1.0.0.56, WNR1000v4 before 1.1.0.54, WNR2020 before 1.1.0.54, WNR2050 before 1.1.0.54, and WNR3500Lv2 before 1.2.0.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial. Esto afecta a D1500 versiones anteriores a 1.0.0.27, D500 versiones anteriores a 1.0.0.27, D6100 versiones anteriores a 1.0.0.58, D6200 versiones anteriores a 1.1.00.30, D6220 versiones anteriores a 1.0.0.46, D6400 versiones anteriores a 1.0.0.82, D7000 versiones anteriores a 1.0.1.68, D7000v2 versiones anteriores a 1.0.0.51, D7800 versiones anteriores a 1.0.1.42, D8500 versiones anteriores a 1.0.3.42, DC112A versiones anteriores a 1.0.0.40, DGN2200Bv4 versiones anteriores a 1.0.0.102, DGN2200v4 versiones anteriores a 1.0.0.102, JNR1010v2 versiones anteriores a 1.1.0.54, JR6150 versiones anteriores a 1.0.1.18, JWNR2010v5 versiones anteriores a 1.1.0.54, PR2000 versiones anteriores a 1.0.0.24, R6020 versiones anteriores a 1.0.0.34, R6050 versiones anteriores a 1.0.1.18, R6080 versiones anteriores a 1.0.0.34, R6100 versiones anteriores a 1.0.1.22, R6120 versiones anteriores a 1.0.0.42, R6220 versiones anteriores a 1.1.0.68, R6250 versiones anteriores a 1.0.4.30, R6300v2 versiones anteriores a 1.0. 4.32, R6400 versiones anteriores a 1.0.1.44, R6400v2 versiones anteriores a 1.0.2.60, R6700 versiones anteriores a 1.0.1.48, R6700v2 versiones anteriores a 1.2.0.24, R6800 versiones anteriores a 1.2.0.24, R6900 versiones anteriores a 1.0.1.48, R6900P versiones anteriores a 1.3.1.44, R6900v2 versiones anteriores a 1.2.0.24, R7000 versiones anteriores a 1.0.9.34, R7000P versiones anteriores a 1.3.1.44, R7100LG versiones anteriores a 1.0.0.48, R7300 versiones anteriores a 1.0.0.68, R7500 versiones anteriores a 1.0.0.124, R7500v2 versiones anteriores a 1.0.3.38, R7900 versiones anteriores a 1.0.2.16, R7900P versiones anteriores a 1.4.1.24, R80 00 versiones anteriores a 1.0.4.18, R8000P versiones anteriores a 1.4.1.24, R8300 versiones anteriores a 1.0.2.122, R8500 versiones anteriores a 1.0.2.122, WN3000RP versiones anteriores a 1.0.0.68, WN3000RPv2 versiones anteriores a 1.0.0.68, WNDR3400v3 versiones anteriores a 1.0.1.18, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR3700v5 1.1.0.54, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56, WNDR4500v3 versiones anteriores a 1.0.0.56, WNR1000v4 versiones anteriores a 1.1.0.54, WNR2020 versiones anteriores a 1.1.0.54, WNR2050 versiones anteriores a 1.1.0.54 y WNR3500Lv2 versiones anteriores a 1.2.0.54." } ], "id": "CVE-2018-21139", "lastModified": "2024-11-21T04:02:59.713", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 4.2, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T21:15:11.690", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060220/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-Smart-Cradles-PSV-2017-2198" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060220/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-Smart-Cradles-PSV-2017-2198" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21201", "lastModified": "2024-11-21T04:03:09.720", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.263", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055148/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2591" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055148/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2591" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2. 40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21204", "lastModified": "2024-11-21T04:03:10.180", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.450", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055145/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2569" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055145/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2569" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 04:02
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CC8DA05-7E8B-4759-9FA8-69626A90662E", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C5401F4-5D39-4A08-BB79-DD6CB2D4C94A", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9960B0A-DB8C-4F8E-8C36-99B64F3A7F71", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "228D2C78-E876-4E4C-A5E2-FB215B0917E2", "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DB980-BC4C-4686-B3EB-A8D9FFC720F1", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FAAE779-B8EA-42A3-BF22-FF17D779300E", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.44, EX6150v2 before 1.0.1.70, EX6100v2 before 1.0.1.70, EX6200v2 before 1.0.1.64, EX7300 before 1.0.2.136, EX6400 before 1.0.2.136, R6100 before 1.0.1.16, R7500 before 1.0.0.110, R7800 before 1.0.2.32, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.52, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.44, EX6150v2 versiones anteriores a 1.0.1.70, EX6100v2 versiones anteriores a 1.0.1.70, EX6200v2 versiones anteriores a 1.0.1.64, EX7300 versiones anteriores a 1.0.2.136, EX6400 versiones anteriores a 1.0.2.136, R6100 versiones anteriores a 1.0.1.16, R7500 versiones anteriores a 1.0.0.110, R7800 versiones anteriores a 1.0.2.32, R9000 versiones anteriores a 1.0.4.12, WN3000RPv2 versiones anteriores a 1.0.0.56, WN3000RPv3 versiones anteriores a 1.0.2.52, WNDR4300v2 versiones anteriores a 1.0.0.50 y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21114", "lastModified": "2024-11-21T04:02:56.130", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:13.537", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060437/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Modem-Routers-and-Wireless-Extenders-PSV-2017-0645" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-07-24 15:29
Modified
2024-11-21 02:54
Severity ?
Summary
There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie_ping.htm or genie_ping2.htm or genie_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz & 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text.
References
▼ | URL | Tags | |
---|---|---|---|
cret@cert.org | https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wndr4500_firmware | 1.0.1.40_1.0.6877 | |
netgear | wndr4500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:1.0.1.40_1.0.6877:*:*:*:*:*:*:*", "matchCriteriaId": "D04EECE1-660F-418A-87F5-525FC0165165", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E9F459C-B628-402A-AF4A-72E08FE41837", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie_ping.htm or genie_ping2.htm or genie_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz \u0026 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text." }, { "lang": "es", "value": "Hay unas pocas p\u00e1ginas web asociadas con la aplicaci\u00f3n genie en Netgear WNDR4500 que ejecutan la versi\u00f3n del firmware V1.0.1.40_1.0.6877. La aplicaci\u00f3n genie agrega algunas capacidades en la interfaz gr\u00e1fica de usuario web y se puede acceder a ella incluso aunque no se est\u00e9 en casa. Un atacante remoto puede acceder a las p\u00e1ginas genie_ping.htm, genie_ping2.htm o genie_ping3.htm sin autenticaci\u00f3n. Una vez se accede a ellas, la p\u00e1gina se redirigir\u00e1 a la p\u00e1gina aCongratulations2.htma, que revela cierta informaci\u00f3n sensible como el nombre de red inal\u00e1mbrica 2.4GHz 5GHz (SSID) y la clave de red (contrase\u00f1a) en texto claro." } ], "id": "CVE-2016-5638", "lastModified": "2024-11-21T02:54:44.823", "metrics": { "cvssMetricV2": [ { "acInsufInfo": true, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-07-24T15:29:00.233", "references": [ { "source": "cret@cert.org", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "cret@cert.org", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 14:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R6100 before 1.0.1.20, R7500 before 1.0.0.118, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects R6100 before 1.0.1.20, R7500 before 1.0.0.118, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a R6100 versiones anteriores a la versi\u00f3n 1.0.1.20, R7500 versiones anteriores a la versi\u00f3n 1.0.0.118, WNDR3700v4 versiones anteriores a la versi\u00f3n 1.0.2.88, WNDR4300 versiones anteriores a la versi\u00f3n 1.0.2.90, WNDR4300v2 versiones anteriores a la versi\u00f3n 1.0.0.48, WNDR4500v3 versiones anteriores a la versi\u00f3n 1.0.0.48, y WNR2000v5 versiones anteriores a la versi\u00f3n 1.0.0.62." } ], "id": "CVE-2017-18706", "lastModified": "2024-11-21T03:20:42.817", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T14:15:12.483", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053196/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-PSV-2017-0516" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 20:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 en versiones anteriores a la 1.0.1.34, DM200 en versiones anteriores a la 1.0.0.50, R6100 en versiones anteriores a la 1.0.1.22, R7500 en versiones anteriores a la 1.0.0.122, R7500v2 en versiones anteriores a la 1.0.3.26, R7800 en versiones anteriores a la 1.0.2.42, R8900 en versiones anteriores a la 1. 0.3.10, R9000 en versiones anteriores a la 1.0.3.10, WNDR3700v4 en versiones anteriores a la 1.0.2.96, WNDR4300 en versiones anteriores a la 1.0.2.98, WNDR4300v2 en versiones anteriores a la 1.0.0.54, WNDR4500v3 en versiones anteriores a la 1.0.0.54, y WNR2000v5 en versiones anteriores a la 1.0.0.64." } ], "id": "CVE-2018-21150", "lastModified": "2024-11-21T04:03:01.397", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T20:15:11.107", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 21:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a la versi\u00f3n 1.0.0.57, R7800 versiones anteriores a la versi\u00f3n 1.0.2.40, R9000 versiones anteriores a la versi\u00f3n 1.0.2.52, WNDR3700v4 versiones anteriores a la versi\u00f3n 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50 y WNR2000v5 versiones anteriores a 1.0.0.62 ." } ], "id": "CVE-2018-21180", "lastModified": "2024-11-21T04:03:06.407", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T21:15:13.267", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055178/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2619" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055178/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2619" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-24 14:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6400_firmware | * | |
netgear | r6400 | - | |
netgear | r6400_firmware | * | |
netgear | r6400 | v2 | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - | |
netgear | r6700_firmware | * | |
netgear | r6700 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB2E25FA-14F1-44ED-99D3-B5ED7D898D59", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "97DE1C91-59A0-4902-B5C7-0CFD2631CAEE", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDC0DA75-5EB9-4F53-99A9-798FFBFD0C15", "versionEndExcluding": "1.0.2.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09963BE1-D57D-491A-9BD8-A1A46ED993E0", "versionEndExcluding": "1.3.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDE61DB5-86A6-4810-91CC-18D05DC09507", "versionEndExcluding": "1.0.9.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "326BBECA-9A76-4A3E-90F7-023797D5D186", "versionEndExcluding": "1.3.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F70E0C-3674-4981-B815-0721F6C6E588", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "442F153C-737B-44D4-9A6D-EB6F6C47B986", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR4300v2 before 1.0.0.48, and WNDR4500v3 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D7800 versiones anteriores a la versi\u00f3n 1.0.1.28, R6400 versiones anteriores a 1.01.32, R6400v2 versiones anteriores a 1.0.2.44, R6700 versiones anteriores a 1.0.1.36, R6900 versiones anteriores a 1.0.1.34, R6900P versiones anteriores a 1.3.0.8, R7000 versiones anteriores a 1. 0.9.14, R7000P versiones anteriores a 1.3.0.8, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR4300v2 versiones anteriores a 1.0.0.48, y WNDR4500v3 versiones anteriores a 1.0.0.48." } ], "id": "CVE-2017-18711", "lastModified": "2024-11-21T03:20:43.637", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-24T14:15:12.810", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053137/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2016-0131" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000053137/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2016-0131" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-21 22:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a la versi\u00f3n 1.0.2.42, R8900 versiones anteriores a la versi\u00f3n 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR4300v2 versiones anteriores a 1.0.0.54 y WNDR4500v3 versiones anteriores a 1.0.0.54." } ], "id": "CVE-2018-21147", "lastModified": "2024-11-21T04:03:00.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-21T22:15:14.307", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059486/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3158" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059486/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3158" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-21 22:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.34, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR4300v2 before 1.0.0.54, and WNDR4500v3 before 1.0.0.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR4300v2 versiones anteriores a 1.0.0.54 y WNDR4500v3 versiones anteriores a 1.0.0.54." } ], "id": "CVE-2018-21146", "lastModified": "2024-11-21T04:03:00.803", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-21T22:15:14.260", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059487/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3159" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059487/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Gateways-and-Routers-PSV-2017-3159" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D7000 before 1.0.1.52, D7000v2 before 1.0.0.38, D7800 before 1.0.1.24, D8500 before 1.0.3.29, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7100LG before 1.0.0.32, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300v1 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA24D11F-7DF0-44E7-B122-7C5853043E71", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D1F0B30-4BB4-4573-BE0D-381B31CD2A36", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "327F762B-1F65-4DE0-B05C-1AAC64974A14", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3052AAF-AA27-4277-AA67-B9C47DF34B88", "versionEndExcluding": "1.0.0.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3197737-90A5-411B-8F3D-902D7FD3CEB6", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20564DE0-E58D-4628-ADD6-AC7C90AD85F7", "versionEndExcluding": "1.0.3.29", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC9E7939-E195-44AB-8880-D0BCF26BF2E0", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E61E9642-91C9-4CA8-BB93-0DE1FEFF48BC", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34429B2B-D8CB-4BEC-B5FA-5C7F8AC9A1FE", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDFB6345-0D0D-4586-9899-2438AADDCD3F", "versionEndExcluding": "1.0.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9886E8AE-A8D3-46E3-95E6-6EEAA2B6B581", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14253C3A-712C-4A7E-83C4-88A6BBEF0AB2", "versionEndExcluding": "1.1.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE68337A-BA04-424A-8DFC-EEE06400D60F", "versionEndExcluding": "1.1.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DBDE97EB-05FE-475E-8A4E-13C97E91548A", "versionEndExcluding": "1.0.2.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D20223D6-9BC2-40CA-9783-2DE0F5F12F64", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E4EF1D0-C132-443E-B7FB-BE050F825D5B", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1088BCE7-C53C-424F-8041-6404D42922F4", "versionEndExcluding": "1.2.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "833A98AF-A4B0-4C68-AACD-6B3F58E64060", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F7508FAE-C117-4E21-8D3D-0016E25363DB", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F889C021-1D38-4A7B-94B4-78FE47699827", "versionEndExcluding": "1.1.4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93CD0427-0CE9-4F1C-933D-0FE6B5626FAC", "versionEndExcluding": "1.1.4.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAAB159C-27F2-4645-9FE4-4DBB4465DE3A", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A79D8A77-4555-4B2A-8F19-F69AD4A17D2E", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "026C640E-7594-4B5A-BDF9-FAB1CD135A47", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "055A63BF-1787-4B72-8416-B6F77025F738", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*", "matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5025770E-D9D0-4FB6-BE29-1F48EDC31AF1", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26E7527-682C-4145-8AE3-F44661285514", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29839E12-4949-49EA-B396-968BB832AE8D", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5684DEA-5F12-4E72-B8D1-C5F3E1D22726", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36CCD48D-4474-4363-8DE6-846714B99D3D", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436026D2-0B8E-4BA5-AD34-9EB285EDA78A", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D7000 before 1.0.1.52, D7000v2 before 1.0.0.38, D7800 before 1.0.1.24, D8500 before 1.0.3.29, JNR1010v2 before 1.1.0.44, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7100LG before 1.0.0.32, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300v1 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a D6220 versiones anteriores a 1.0.0.28, D6400 versiones anteriores a 1.0.0.60, D7000 versiones anteriores a 1.0.1.52, D7000v2 versiones anteriores a 1.0.0.38, D7800 versiones anteriores a 1.0.1.24, D8500 versiones anteriores a 1.0.3.29, JNR1010v2 versiones anteriores a 1.1.0.44, JR6150 versiones anteriores a 1.0.1.14, JWNR2010v5 versiones anteriores a 1.1.0.44, PR2000 versiones anteriores a 1.0.0.20, R6050 versiones anteriores a 1.0.1.14, R6220 versiones anteriores a 1.1.0.60, R6400 versiones anteriores a 1.1.0.26, R6400v2 versiones anteriores a 1.0.2.46, R6700v2 versiones anteriores a 1.2.0.2, R6800 versiones anteriores a 1.2.0.2, R6900v2 versiones anteriores a 1.2.0.2, R7100LG versiones anteriores a 1.0.0.32, R7300DST versiones anteriores a 1.0.0.56, R7500 versiones anteriores a 1.0.0.112, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.36, R7900P versiones anteriores a 1.1.4.6, R8000P versiones anteriores a 1.1.4.6, R8300 versiones anteriores a 1.0. 2.104, R8500 versiones anteriores a 1.0.2.104, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.94, WNDR3700v5 versiones anteriores a 1.1.0.50, WNDR4300v1 versiones anteriores a 1.0.2.96, WNDR4300v2 versiones anteriores a 1.0.0.52, WNDR4500v3 versiones anteriores a 1.0.0.52, WNR1000v4 versiones anteriores a 1.1.0.42 WNR2020 versiones anteriores a 1.1.0.44 y WNR2050 versiones anteriores a 1.1.0.44." } ], "id": "CVE-2017-18778", "lastModified": "2024-11-21T03:20:53.747", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.5, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:12.253", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049543/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2957" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049543/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-and-Gateways-PSV-2017-2957" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | ex8000_firmware | * | |
netgear | ex8000 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03798255-94BA-427C-8B2D-0861CD5FF730", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048", "versionEndExcluding": "1.0.1.180", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, DM200 before 1.0.0.58, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, DM200 versiones anteriores a 1.0.0.58, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1. 0,1,76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7300 versiones anteriores a 1.0.2.136, EX8000 versiones anteriores a 1.0.1. 180, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1. 0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20723", "lastModified": "2024-11-21T04:39:11.273", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.337", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061205/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0146" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r900_firmware | * | |
netgear | r900 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3ABBD2E7-85AA-4EDA-908C-410D44DD74DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r900:-:*:*:*:*:*:*:*", "matchCriteriaId": "F75EB581-AACC-401D-ACA7-0BCA73D12621", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC14D1E5-1302-4E4E-9119-E64342B0AE21", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D7800 versiones anteriores a 1.0.1.30, EX2700 versiones anteriores a 1.0.1.28, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2. 40, R9000 versiones anteriores a 1.0.2.52, WN2000RPTv3 versiones anteriores a 1.0.1.20, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, y WNDR4500v3 versiones anteriores a 1.0.0.50." } ], "id": "CVE-2018-21212", "lastModified": "2024-11-21T04:03:11.420", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.997", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055137/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2490" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055137/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2490" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.52, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.4.2, R9000 before 1.0.3.16, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7DEE689F-923A-414C-B048-E4716DA2B783", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93C7D5A8-3B1D-4DCD-ACB6-8629CE598C25", "versionEndExcluding": "1.0.3.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.52, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.4.2, R9000 before 1.0.3.16, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, DM200 versiones anteriores a 1.0.0.52, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.3.16, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21155", "lastModified": "2024-11-21T04:03:02.177", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 2.1, "impactScore": 3.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.357", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Gateways-and-Routers-PSV-2017-3101" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Gateways-and-Routers-PSV-2017-3101" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-23 17:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects EX6150v2 before 1.0.1.54, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.22, R6900 before 1.0.1.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R6900P before 1.2.0.22, R7100LG before 1.0.0.32, R7300DST before 1.0.0.54, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.106, R8500 before 1.0.2.106, R6100 before 1.0.1.16, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | r6400_firmware | * | |
netgear | r6400 | - | |
netgear | r6400_firmware | * | |
netgear | r6400 | v2 | |
netgear | r6700_firmware | * | |
netgear | r6700 | - | |
netgear | r6900_firmware | * | |
netgear | r6900 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7100lg_firmware | * | |
netgear | r7100lg | - | |
netgear | r7300dst_firmware | * | |
netgear | r7300dst | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8300_firmware | * | |
netgear | r8300 | - | |
netgear | r8500_firmware | * | |
netgear | r8500 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F476F7D7-EAE2-4A09-8C4B-A53F885A1337", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29EA60BF-FBA6-4305-8173-07130A527410", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB7B08B9-07D2-4404-846A-D1CA02C16557", "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C3255EE-BBE5-4EBE-92CC-D0C6E6D8563F", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "24E4CE14-4FC5-4F73-BFC8-F0B0D924F788", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD7D570E-C5EF-4D3E-BCCF-926DBDB12016", "versionEndExcluding": "1.0.9.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133", "versionEndExcluding": "1.2.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "833A98AF-A4B0-4C68-AACD-6B3F58E64060", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0EE8EBA-C4CD-4CA1-A684-54338B1254A9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98DFA81-D1BA-41AE-A6A3-1EBBFC452D0F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7393D4D7-F607-423E-917E-FE520D7A3A73", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BCE9CF95-192E-4D43-9DAD-2C8D9AF045E9", "versionEndExcluding": "1.0.2.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DFD7557-D13D-40EB-94AD-AF092CDE587A", "versionEndExcluding": "1.0.2.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects EX6150v2 before 1.0.1.54, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.22, R6900 before 1.0.1.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R6900P before 1.2.0.22, R7100LG before 1.0.0.32, R7300DST before 1.0.0.54, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.106, R8500 before 1.0.2.106, R6100 before 1.0.1.16, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a EX6150v2 versiones anteriores a 1.0.1.54, R6400 versiones anteriores a 1.0.1.24, R6400v2 versiones anteriores a 1.0.2.32, R6700 versiones anteriores a 1.0.1.22, R6900 versiones anteriores a 1.0.1.22, R7000 versiones anteriores a 1.0.9.10, R7000P versiones anteriores a 1.2.0.22, R6900P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.32, R7300DST versiones anteriores a 1.0.0.54, R7900 versiones anteriores a 1.0.1.18, R8000 versiones anteriores a 1.0.3.48, R8300 versiones anteriores a 1.0.2.106, R8500 versiones anteriores a 1.0.2.106, R6100 versiones anteriores a 1.0.1.16, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.58." } ], "id": "CVE-2017-18738", "lastModified": "2024-11-21T03:20:48.017", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-23T17:15:12.550", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051517/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Extenders-PSV-2017-0706" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051517/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-and-Extenders-PSV-2017-0706" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by CSRF. This affects R6100 before 1.0.1.12, R7500 before 1.0.0.108, WNDR3700v4 before 1.0.2.86, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.42.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D3B299C-B097-4287-B250-DA6488970976", "versionEndExcluding": "1.0.1.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F05A673D-1AA7-4DDA-A00C-EBC353777417", "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "469F00DE-BE32-4417-AE64-1C6340138928", "versionEndExcluding": "1.0.2.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E6E8DBB-487E-45DE-990D-AF193F05BA97", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3B5B30F-0159-48B6-BC8D-BF8F2EE519D6", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects R6100 before 1.0.1.12, R7500 before 1.0.0.108, WNDR3700v4 before 1.0.2.86, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.42." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo CSRF. Esto afecta a R6100 versiones anteriores a 1.0.1.12, R7500 versiones anteriores a 1.0.0.108, WNDR3700v4 versiones anteriores a 1.0.2.86, WNDR4300v1 versiones anteriores a 1.0.2.88, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.42." } ], "id": "CVE-2017-18775", "lastModified": "2024-11-21T03:20:53.187", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:12.003", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049553/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-and-Gateways-PSV-2017-0388" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049553/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-Routers-and-Gateways-PSV-2017-0388" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by XSS. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6100v2 before 1.0.1.54, EX6150v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6020 before 1.0.0.26, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6800 before 1.2.0.12, R6900v2 before 1.2.0.12, R6700v2 before 1.2.0.12, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.18, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R7900P before 1.1.5.14, R8000 before 1.0.4.4, R8000P before 1.1.5.14, R8500 before 1.0.2.110, R8300 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.8, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.42, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B5A756C-6CA4-46EF-80B8-9051FB607B43", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA902AA9-525D-46BD-B586-1A0DC40EE391", "versionEndExcluding": "1.1.00.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "00E6A1B7-4732-4259-9B71-10FF0B56A16B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1FD6552E-5BF6-4E57-90A7-39C4543B469C", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE087F75-4C99-425C-A9B7-B261E5545297", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "327F762B-1F65-4DE0-B05C-1AAC64974A14", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34A8EAED-389E-4B14-949E-ED87A09F4D91", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9398174B-A4A6-449A-AB91-A93D3D9398DD", "versionEndExcluding": "1.0.3.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0ABDCFC2-E9EC-40F4-862F-B86FDD0A6AC7", "versionEndExcluding": "1.0.0.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D989DB4-5276-4BCF-A15E-BC207E03B2C7", "versionEndExcluding": "1.0.0.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A7D6C145-E2CD-4030-8AA8-C4071C0E242B", "versionEndExcluding": "1.0.1.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EFE54D2-78A3-4461-BA5E-6807911C5684", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F476F7D7-EAE2-4A09-8C4B-A53F885A1337", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BCBD76F6-4E46-42E1-A6B6-373F2F7DB4AF", "versionEndExcluding": "1.0.1.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "85392ECB-985F-43B2-89BE-755E433FC14B", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0D1F6E4-A21F-4B86-B903-C26BB062D0DD", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BBA04A7E-6029-498B-970E-0317BE0CF0F2", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC9E7939-E195-44AB-8880-D0BCF26BF2E0", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34429B2B-D8CB-4BEC-B5FA-5C7F8AC9A1FE", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*", "matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDFB6345-0D0D-4586-9899-2438AADDCD3F", "versionEndExcluding": "1.0.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF013048-DE20-49A5-9091-DD0DEA830D33", "versionEndExcluding": "1.0.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D70F5F17-5134-47AB-B182-321B1B0CD72B", "versionEndExcluding": "1.0.0.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5E7A8CA-134F-49B4-95D6-79A88CD6BB80", "versionEndExcluding": "1.0.4.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55058831-92FF-4A87-8340-E25AC0DDF89E", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "97DE1C91-59A0-4902-B5C7-0CFD2631CAEE", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DBDE97EB-05FE-475E-8A4E-13C97E91548A", "versionEndExcluding": "1.0.2.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "442F153C-737B-44D4-9A6D-EB6F6C47B986", "versionEndExcluding": "1.0.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36949C1B-4E77-447C-A206-B4E8385FA6C5", "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B7CDA8C-3ED3-46B2-AC4F-330251B7F454", "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4096E4AD-F3DA-4D1D-BD48-E39235669A68", "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F70E0C-3674-4981-B815-0721F6C6E588", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "326BBECA-9A76-4A3E-90F7-023797D5D186", "versionEndExcluding": "1.3.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03DC2062-58D1-40D6-8536-A13C87F2CF11", "versionEndExcluding": "1.0.9.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09963BE1-D57D-491A-9BD8-A1A46ED993E0", "versionEndExcluding": "1.3.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2FB08FA1-A476-4E05-9904-9BE30C9E77B7", "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B75230D7-5B50-47C2-B5C5-C60C6974C305", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BCE1150D-8464-4421-94BD-EE81977BAC34", "versionEndExcluding": "1.0.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "606460FB-B46F-4490-96FC-B226F3A2C55D", "versionEndExcluding": "1.1.5.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "78819A69-AF43-4741-AE4D-5FEC4280F25F", "versionEndExcluding": "1.0.4.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B508ABA6-F17C-43D4-88D8-56ECD0057C65", "versionEndExcluding": "1.1.5.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7A3E675-BB4F-4E8B-A041-C208F85B5C0E", "versionEndExcluding": "1.0.2.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DDFEFE-402D-4AA8-A2C9-2217A5643DC1", "versionEndExcluding": "1.0.2.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B569EC22-7AB5-4136-B83E-BC466A6562B2", "versionEndExcluding": "1.0.1.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "030AAA8B-65D9-42E4-ACF6-F2DB13D4AA30", "versionEndExcluding": "1.0.2.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B562B414-1A33-4E81-83FF-D8750D977DDC", "versionEndExcluding": "1.0.0.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72DCD4C0-A757-4F98-97BD-FB1FEBF3235C", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "026C640E-7594-4B5A-BDF9-FAB1CD135A47", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5025770E-D9D0-4FB6-BE29-1F48EDC31AF1", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5684DEA-5F12-4E72-B8D1-C5F3E1D22726", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*", "matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36CCD48D-4474-4363-8DE6-846714B99D3D", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436026D2-0B8E-4BA5-AD34-9EB285EDA78A", "versionEndExcluding": "1.1.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*", "matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB542F95-5AE2-47E4-BD7B-34134B26AA4F", "versionEndExcluding": "1.2.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by XSS. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D6200 before 1.1.00.24, D6220 before 1.0.0.32, D6400 before 1.0.0.66, D7000 before 1.0.1.52, D7000v2 before 1.0.0.44, D7800 before 1.0.1.30, D8500 before 1.0.3.35, DGN2200v4 before 1.0.0.96, DGN2200Bv4 before 1.0.0.96, EX2700 before 1.0.1.28, EX6100v2 before 1.0.1.54, EX6150v2 before 1.0.1.54, EX6200v2 before 1.0.1.52, EX6400 before 1.0.1.72, EX7300 before 1.0.1.72, EX8000 before 1.0.0.102, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6020 before 1.0.0.26, R6080 before 1.0.0.26, R6100 before 1.0.1.20, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.0.1.32, R6400v2 before 1.0.2.46, R6700 before 1.0.1.36, R6800 before 1.2.0.12, R6900v2 before 1.2.0.12, R6700v2 before 1.2.0.12, R6900 before 1.0.1.34, R6900P before 1.3.0.8, R7000 before 1.0.9.18, R7000P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.58, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R7900 before 1.0.2.4, R7900P before 1.1.5.14, R8000 before 1.0.4.4, R8000P before 1.1.5.14, R8500 before 1.0.2.110, R8300 before 1.0.2.110, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.8, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.42, WNDR3400v3 before 1.0.1.16, WNDR3700v4 before 1.0.2.94, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, WNR1000v4 before 1.1.0.44, WNR2000v5 before 1.0.0.62, WNR2020 before 1.1.0.44, WNR2050 before 1.1.0.44, and WNR3500Lv2 before 1.2.0.46." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D6100 versiones anteriores a 1.0.0.56, D6200 versiones anteriores a 1.1.00.24, D6220 versiones anteriores a 1.0.0.32, D6400 versiones anteriores a 1.0.0.66, D7000 versiones anteriores a 1.0.1.52, D7000v2 versiones anteriores a 1.0.0.44, D7800 versiones anteriores a 1.0.1.30, D8500 versiones anteriores a 1.0.3.35, DGN2200v4 versiones anteriores a 1.0.0.96, DGN2200Bv4 versiones anteriores a 1.0.0.96, EX2700 versiones anteriores a 1.0.1.28, EX6100v2 versiones anteriores a 1.0.1.54, EX6150v2 versiones anteriores a 1.0.1.54, EX6200v2 versiones anteriores a 1.0.1.52, EX6400 versiones anteriores a 1.0.1.72, EX7300 versiones anteriores a 1.0.1.72, EX8000 versiones anteriores a 1.0.0.102, JNR1010v2 versiones anteriores a 1.1.0.44, JWNR2010v5 versiones anteriores a 1.1.0.44, PR2000 versiones anteriores a 1.0.0.20, R6020 versiones anteriores a 1.0.0.26, R6080 versiones anteriores a 1.0.0.26, R6100 versiones anteriores a 1.0. 1.20, R6250 versiones anteriores a 1.0.4.16, R6300v2 versiones anteriores a 1.0.4.18, R6400 versiones anteriores a 1.0.1.32, R6400v2 versiones anteriores a 1.0.2.46, R6700 versiones anteriores a 1.0.1.36, R6800 versiones anteriores a 1.2.0.12, R6900v2 versiones anteriores a 1.2.0.12, R6700v2 versiones anteriores a 1.2.0.12, R6900 versiones anteriores a 1.0.1.34, R6900P versiones anteriores a 1.3.0.8, R7000 versiones anteriores a 1.0.9.18, R7000P versiones anteriores a 1.3.0.8, R7100LG versiones anteriores a 1.0.0.34, R7300DST versiones anteriores a 1.0.0.58, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1. 0.3.24, R7800 versiones anteriores a 1.0.2.40, R7900 versiones anteriores a 1.0.2.4, R7900P versiones anteriores a 1.1.5.14, R8000 versiones anteriores a 1.0.4.4, R8000P versiones anteriores a 1.1.5.14, R8500 versiones anteriores a 1.0.2.110, R8300 versiones anteriores a 1.0.2.110, R9000 versiones anteriores a 1.0. 2.52, WN2000RPTv3 versiones anteriores a 1.0.1.8, WN3000RPv3 versiones anteriores a 1.0.2.50, WN3100RPv2 versiones anteriores a 1.0.0.42, WNDR3400v3 versiones anteriores a 1.0.1.16, WNDR3700v4 versiones anteriores a 1.0.2.94, WNDR4300 versiones anteriores a 1.0.2.96, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versi\u00f3n anteriores a 1.0.0.50, WNR1000v4 versiones anteriores a 1.1.0.44, WNR2000v5 versiones anteriores a 1.0.0.62, WNR2020 versiones anteriores a 1.1.0.44, WNR2050 versiones anteriores a 1.1.0.44 y WNR3500Lv2 versiones anteriores a 1.2.0.46." } ], "id": "CVE-2017-18785", "lastModified": "2024-11-21T03:20:54.943", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.1, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:12.957", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049534/Security-Advisory-for-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2950" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049534/Security-Advisory-for-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2950" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 20:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6000 before 1.0.0.72, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33C16A69-C930-4DA3-8750-EB50F2827731", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6000 before 1.0.0.72, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6000 versiones anteriores a 1.0.0.72, D6100 versiones anteriores a 1.0.0.63, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1. 0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20736", "lastModified": "2024-11-21T04:39:13.527", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T20:15:13.680", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061190/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0133" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061190/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0133" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 21:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex8000_firmware | * | |
netgear | ex8000 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA3E7329-F839-4DD3-921F-B9E8DEDC8F12", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349", "versionEndExcluding": "1.0.0.61", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F6F80A7-3B51-46FD-854E-D848F7906048", "versionEndExcluding": "1.0.1.180", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEF7967B-5FA3-4D43-BEC5-2644FBB1D168", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D34DD834-FE59-4F04-9448-FDC385CF70F6", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A480981E-57ED-47E3-B9AB-190E4783DC04", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.60, DM200 versiones anteriores a 1.0.0.61, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX8000 versiones anteriores a 1.0.1.180, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0. 4.26, R9000 versiones anteriores a 1.0.4.26, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.66, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68." } ], "id": "CVE-2019-20751", "lastModified": "2024-11-21T04:39:16.010", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T21:15:13.067", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R6100 before 1.0.1.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.20, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21189", "lastModified": "2024-11-21T04:03:07.827", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.550", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055168/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2606" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055168/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2606" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-21 22:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, DM200 versiones anteriores a 1.0.0.50, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.42, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21148", "lastModified": "2024-11-21T04:03:01.090", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-21T22:15:14.367", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059485/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3157" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059485/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3157" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50 y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21172", "lastModified": "2024-11-21T04:03:04.907", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.967", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055186/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2631" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055186/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2631" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 17:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47FB5F9D-2B33-44AD-BD57-164DF945ADA7", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2089DF5E-598C-4CC2-B910-05C8D209A1BB", "versionEndExcluding": "1.0.0.67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7494430D-BA3F-4EDB-9FB8-7586D4457B9D", "versionEndExcluding": "1.0.0.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.67, D6000 versiones anteriores a 1.0.0.67, D7800 versiones anteriores a 1.0.1.30, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.118, R7500v2 versiones anteriores a 1.0.3. 24, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21224", "lastModified": "2024-11-21T04:03:13.280", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T17:15:13.103", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055113/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2456" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.62, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D8426F7-28E5-4903-8936-B6F8D5733142", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C5401F4-5D39-4A08-BB79-DD6CB2D4C94A", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CC8DA05-7E8B-4759-9FA8-69626A90662E", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79641CA1-DCB5-4793-A710-CBEC23809C7F", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66120328-5681-46E5-86A5-CAC62B9243B9", "versionEndExcluding": "1.0.1.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E04A47C-ACFE-4B89-A256-3CA699A1B4A5", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C1D8706-BB8E-4EBC-B76C-533062BF86EE", "versionEndExcluding": "1.0.0.114", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B", "versionEndExcluding": "1.0.3.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058BC554-8E48-460E-A305-B5CDA8249B28", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DB980-BC4C-4686-B3EB-A8D9FFC720F1", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAFDAF9A-711E-497F-8632-0345B635A7C9", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E449BEE1-DFE7-413C-B15E-4E6EE6FB84CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DB649EB-E2F9-4E11-B68A-50B0096AF9B6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.62, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.34, DM200 versiones anteriores a 1.0.0.50, EX2700 versiones anteriores a 1.0.1.32, EX6100v2 versiones anteriores a 1.0.1.70, EX6150v2 versiones anteriores a 1.0.1.70, EX6200v2 versiones anteriores a 1.0.1.62, EX6400 versiones anteriores a 1.0.1.78, EX7300 versiones anteriores a 1.0.1.62, EX8000 versiones anteriores a 1.0.0.114, R6100 versiones anteriores a 1.0.1.22, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.26, R7800 versiones anteriores a 1.0.2.40, R8900 versiones anteriores a 1.0.3.10, R9000 versiones anteriores a 1.0.3.10, WN2000RPTv3 versiones anteriores a 1.0.1.26, WN3000RPv2 versiones anteriores a 1.0.0.56, WN3000RPv3 versiones anteriores a 1.0.2.66, WN3100RPv2 versiones anteriores a 1.0.0.56, WNDR4300 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54 y WNR2000v5 versiones anteriores a 1.0.0.64." } ], "id": "CVE-2018-21153", "lastModified": "2024-11-21T04:03:01.853", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:12.230", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059480/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Gateways-Routers-and-Extenders-PSV-2017-3136" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059480/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Gateways-Routers-and-Extenders-PSV-2017-3136" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1. 0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20725", "lastModified": "2024-11-21T04:39:11.597", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.463", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061203/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0143" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061203/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2018-0143" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 22:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6220 before 1.0.0.46, D6400 before 1.0.0.80, D7000v2 before 1.0.0.51, D8500 before 1.0.3.42, DGN2200v1 before 1.0.0.58, DGN2200B before 1.0.0.58, JNDR3000 before 1.0.0.24, RBW30 before 2.1.4.16, R6250 before 1.0.4.26, R6300v2 before 1.0.4.28, R6400 before 1.0.1.42, R6400v2 before 1.0.2.56, R6700 before 1.0.1.46, R6900 before 1.0.1.46, R7000 before 1.0.9.32, R6900P before 1.3.1.44, R7100LG before 1.0.0.46, R7300DST before 1.0.0.68, R7000P before 1.3.1.44, R7900 before 1.0.2.16, R8000P before 1.4.0.10, R7900P before 1.4.0.10, R8300 before 1.0.2.122, R8500 before 1.0.2.122, R8000 before 1.0.4.18, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, WNR3500Lv2 before 1.2.0.54, WN3100RP before 1.0.0.20, and WN2500RPv2 before 1.0.1.54.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6ABD67D-F08A-4879-A497-EA3DF0A87D4B", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76FA59AE-35D5-443C-8C05-3989DD59B32F", "versionEndExcluding": "1.0.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52FB0300-0FC9-4797-BACB-84D7D932A386", "versionEndExcluding": "1.0.0.51", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "629E89E8-F329-4D11-9652-540752084DD3", "versionEndExcluding": "1.0.3.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "99288EE6-3A88-4134-992D-148868117AFC", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v1:*:*:*:*:*:*:*", "matchCriteriaId": "F50D834B-D7B3-43D6-8072-8992FBC8C97B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "082AB982-1EF7-417D-88CD-21F3860AF8C4", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:-:*:*:*:*:*:*:*", "matchCriteriaId": "C85C6885-636D-4583-AEEF-FC23D93CCC35", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jndr3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07C1E707-AB63-4812-9BBC-7267AD17BFF9", "versionEndExcluding": "1.0.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jndr3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DEEEEE5-0798-450E-BF9D-B17A15235C80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "583C272B-68C0-4727-884F-BF7759D829DB", "versionEndExcluding": "2.1.4.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D1A9B6F-89B2-4785-A0E2-3FD322D6A28F", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "502055F1-F919-4C91-A3D0-B144027BC690", "versionEndExcluding": "1.0.4.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "741413AB-9519-4BBE-BEDB-DFA2077BAF79", "versionEndExcluding": "1.0.1.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "203541F7-8AC5-436A-808E-935B03B00E8D", "versionEndExcluding": "1.0.2.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E821B01-31C8-4766-BAAF-D814336617B9", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08FF0010-66E3-485C-A22B-39E57E738550", "versionEndExcluding": "1.0.1.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B1C19D9-9195-4C24-B346-10AAC4106B89", "versionEndExcluding": "1.0.9.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52A6DEB2-3A33-4184-866D-9C8D9DD991C6", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E59E66D2-7E73-45C8-8D3E-FE589CDBECA4", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94B3A9D8-A276-41B2-B7BF-7DA58B879A9B", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*", "matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90805FFE-E59D-43D2-BF1E-D55458CF05BF", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "471E4F42-7114-4A7F-832D-2E9222BD25B4", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D59690E-4182-40B0-872C-8392352C0B00", "versionEndExcluding": "1.4.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E0102F4-A45E-4715-8D3F-4DC96EC5865C", "versionEndExcluding": "1.4.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB84CB9C-DA5C-4D18-9A54-375DD091D932", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4CA2B4B5-ED8D-476F-9F6E-630B43A38E27", "versionEndExcluding": "1.0.2.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C5FC237-F74C-4771-B5D3-36CF245C0396", "versionEndExcluding": "1.0.4.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "46D1F73B-1AE0-40AE-BED7-CAE3C7EFEE3B", "versionEndExcluding": "1.0.1.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EEBD4A-4734-4F43-B7D4-39D81C83A873", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "AB00ECAD-7474-4D85-8248-D014E5808814", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E338A30-C349-41B4-B971-E6D6B0E9AFE4", "versionEndExcluding": "1.2.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7BD4DF32-99E8-4958-A220-B2578E3FA2D0", "versionEndExcluding": "1.0.0.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA8678D2-8FFA-4C5C-B97D-19AE3456F7BC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0675F6C4-EB61-4DA3-8473-448E93D5E0A5", "versionEndExcluding": "1.0.1.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "1C4C1B98-9551-4862-AEAC-3D5C313BD275", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6220 before 1.0.0.46, D6400 before 1.0.0.80, D7000v2 before 1.0.0.51, D8500 before 1.0.3.42, DGN2200v1 before 1.0.0.58, DGN2200B before 1.0.0.58, JNDR3000 before 1.0.0.24, RBW30 before 2.1.4.16, R6250 before 1.0.4.26, R6300v2 before 1.0.4.28, R6400 before 1.0.1.42, R6400v2 before 1.0.2.56, R6700 before 1.0.1.46, R6900 before 1.0.1.46, R7000 before 1.0.9.32, R6900P before 1.3.1.44, R7100LG before 1.0.0.46, R7300DST before 1.0.0.68, R7000P before 1.3.1.44, R7900 before 1.0.2.16, R8000P before 1.4.0.10, R7900P before 1.4.0.10, R8300 before 1.0.2.122, R8500 before 1.0.2.122, R8000 before 1.0.4.18, WNDR3400v3 before 1.0.1.22, WNDR4500v2 before 1.0.0.72, WNR3500Lv2 before 1.2.0.54, WN3100RP before 1.0.0.20, and WN2500RPv2 before 1.0.1.54." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6220 versiones anteriores a 1.0.0.46, D6400 versiones anteriores a 1.0.0.80, D7000v2 versiones anteriores a 1.0.0.51, D8500 versiones anteriores a 1.0.3.42, DGN2200v1 versiones anteriores a 1.0.0.58, DGN2200B versiones anteriores a 1.0.0.58, JNDR3000 versiones anteriores a 1.0.0. 24, RBW30 versiones anteriores a 2.1.4.16, R6250 versiones anteriores a 1.0.4.26, R6300v2 versiones anteriores a 1.0.4.28, R6400 versiones anteriores a 1.0.1.42, R6400v2 versiones anteriores a 1.0.2.56, R6700 versiones anteriores a 1.0.1.46, R6900 versiones anteriores a 1.0.1.46, R7000 versiones anteriores a 1.0.9. 32, R6900P versiones anteriores a 1.3.1.44, R7100LG versiones anteriores a 1.0.0.46, R7300DST versiones anteriores a 1.0.0.68, R7000P versiones anteriores a 1.3.1.44, R7900 versiones anteriores a 1.0.2.16, R8000P versiones anteriores a 1.4.0.10, R7900P versiones anteriores a 1.4.0.10, R8300 versiones anteriores a 1.0.2. 122, R8500 versiones anteriores a 1.0.2.122, R8000 versiones anteriores a 1.0.4.18, WNDR3400v3 versiones anteriores a 1.0.1.22, WNDR4500v2 versiones anteriores a 1.0.0.72, WNR3500Lv2 versiones anteriores a 1.2.0.54, WN3100RP versiones anteriores a 1.0.0.20, y WN2500RPv2 versiones anteriores a 1.0.1.54." } ], "id": "CVE-2019-20755", "lastModified": "2024-11-21T04:39:16.770", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T22:15:12.930", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060627/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Modem-Routers-Extenders-and-Orbi-Satellites-PSV-2018-0053" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000060627/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Modem-Routers-Extenders-and-Orbi-Satellites-PSV-2018-0053" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A37AA7DC-5B2C-4E1B-8556-F1C9F6BBE9D7", "versionEndExcluding": "1.0.0.55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3197737-90A5-411B-8F3D-902D7FD3CEB6", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9984CEE5-F523-4546-AEAD-4361D2BC6D2B", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E8197CA-84A2-4714-8EBB-04BA4B66ED29", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F227D99-88C9-457F-BCA5-665F531E04AB", "versionEndExcluding": "1.0.0.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F587C0F-5A9A-468B-B680-21EB9700DD4B", "versionEndExcluding": "1.0.3.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6", "versionEndExcluding": "1.0.2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C8BF9E6-5EEB-48A3-BF23-30FFB78F339A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6100 before V1.0.0.55, D7800 before V1.0.1.24, EX6150v2 before 1.0.0.48, R6100 before 1.0.1.14, R7500 before 1.0.0.110, R7500v2 before V1.0.3.16, R7800 before V1.0.2.36, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.48." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a V1.0.0.55, D7800 versiones anteriores a V1.0.1.24, EX6150v2 versiones anteriores a 1.0.0.48, R6100 versiones anteriores a 1.0.1.14, R7500 versiones anteriores a 1.0.0.110, R7500v2 versiones anteriores a V1.0.3.16, R7800 versiones anteriores a V1.0.2. 36, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.48." } ], "id": "CVE-2017-18773", "lastModified": "2024-11-21T03:20:53.010", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:11.863", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000049556/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2184" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 21:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7740F3DB-8647-4D9A-BA3D-3944BCF51263", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0173E81F-5BE3-4249-A620-EC36AD109D75", "versionEndExcluding": "1.0.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.30, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a la versi\u00f3n 1.0.0.57, D7800 versiones anteriores a la versi\u00f3n 1.0.1.30, R7500 versiones anteriores a la versi\u00f3n 1.0.0.122, R7500v2 versiones anteriores a la versi\u00f3n 1.0.3.24, R7800 versiones anteriores a la versi\u00f3n 1.0.2.40, R9000 versiones anteriores a la versi\u00f3n 1.0.2.52, WNDR3700v4 versiones anteriores a la versi\u00f3n 1.0.2.92, WNDR4300 versiones anteriores a la versi\u00f3n 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50 y WNR2000v5 versiones anteriores a la versi\u00f3n 1.0.0.62." } ], "id": "CVE-2018-21179", "lastModified": "2024-11-21T04:03:06.250", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T21:15:13.203", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055179/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2620" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055179/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2620" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 20:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before V1.0.0.75, D6100 before V1.0.0.63, R7800 before v1.0.2.52, R8900 before v1.0.4.2, R9000 before v1.0.4.2, RBK50 before v2.3.0.32, RBR50 before v2.3.0.32, RBS50 before v2.3.0.32, WNDR3700v4 before V1.0.2.102, WNDR4300v1 before V1.0.2.104, WNDR4300v2 before v1.0.0.58, WNDR4500v3 before v1.0.0.58, WNR2000v5 before v1.0.0.68, and XR500 before V2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v1 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 | |
netgear | xr500_firmware | * | |
netgear | xr500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A", "versionEndExcluding": "1.0.0.63", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before V1.0.0.75, D6100 before V1.0.0.63, R7800 before v1.0.2.52, R8900 before v1.0.4.2, R9000 before v1.0.4.2, RBK50 before v2.3.0.32, RBR50 before v2.3.0.32, RBS50 before v2.3.0.32, WNDR3700v4 before V1.0.2.102, WNDR4300v1 before V1.0.2.104, WNDR4300v2 before v1.0.0.58, WNDR4500v3 before v1.0.0.58, WNR2000v5 before v1.0.0.68, and XR500 before V2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 antes de V1.0.0.75, D6100 antes de V1.0.0.63, R7800 antes de v1.0.2.52, R8900 antes de v1.0.4.2, R9000 antes de v1.0.4.2, RBK50 antes de v2.3.0.32, RBR50 antes de v2.3.0. 32, RBS50 antes de la v2.3.0.32, WNDR3700v4 versiones anteriores a v1.0.2.102, WNDR4300v1 versiones anteriores a v1.0.2.104, WNDR4300v2 versiones anteriores a v1.0.0.58, WNDR4500v3 versiones anteriores a v1.0.0.58, WNR2000v5 versiones anteriores a v1.0.0.68, y XR500 antes de la v2.3.2.32." } ], "id": "CVE-2019-20735", "lastModified": "2024-11-21T04:39:13.343", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T20:15:13.633", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 13:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, D7800 versiones anteriores a 1.0.1.34, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1. 0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21185", "lastModified": "2024-11-21T04:03:07.177", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T13:15:12.747", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-27 18:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7500 before 1.0.0.122, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a R7500 versiones anteriores a 1.0.0.122, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50 y WNR2000v5 versiones anteriores a 1.0.0.62 ." } ], "id": "CVE-2018-21173", "lastModified": "2024-11-21T04:03:05.063", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-27T18:15:13.027", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055185/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2627" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055185/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2627" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-22 15:15
Modified
2024-11-21 03:20
Severity ?
Summary
Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX6200v2 before 1.0.1.50, EX7000 before 1.0.0.56, JR6150 before 1.0.1.18, R6050 before 1.0.1.10J, R6100 before 1.0.1.16, R6150 before 1.0.1.10, R6220 before 1.1.0.50, R6250 before 1.0.4.12, R6300v2 before 1.0.4.12, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.26, R6700v2 before 1.2.0.4, R6800 before 1.0.1.10, R6900 before 1.0.1.26, R6900P before 1.0.0.58, R6900v2 before 1.2.0.4, R7000 before 1.0.9.6, R7000P before 1.0.0.58, R7100LG before 1.0.0.32, R7300 before 1.0.0.54, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.40, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR3500Lv2 before 1.2.0.44.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8AA0851-BFD5-45F6-9673-CA4B83D8B844", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD763D04-70A0-4A50-8866-330B82703680", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82EB2B81-08D9-4C81-B6DE-8D1FCAEC485A", "versionEndExcluding": "1.0.1.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5E70AF3-FFD8-4ACD-9F4C-DB03BFB1125A", "versionEndExcluding": "1.0.3.39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA60A85-77FF-41BF-89FA-7EB3ACFECDB8", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200b_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5C27C8A-1B80-47CD-B015-14588F4F8732", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200b:v4:*:*:*:*:*:*:*", "matchCriteriaId": "25090794-A90C-40CD-8E95-87EC4E98B928", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "373DAD59-79CC-428D-AD6D-935DFD360D39", "versionEndExcluding": "1.0.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "274A58AC-3E28-411B-8495-2ADD184CFAE6", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC9C60BB-2E7F-4D35-9348-8D8AEFAAD75F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2DECC28-182A-496F-91DA-C2B5DA6F7AF5", "versionEndExcluding": "1.0.1.10j", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*", "matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6", "versionEndExcluding": "1.0.1.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0330A404-6120-4F8E-9600-C2524EA1DEC7", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "05ED104B-38C7-4D9E-9239-B8556787C32B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607", "versionEndExcluding": "1.1.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3464F16-A6EB-47C0-B2B5-54E86743DC70", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E43DA92A-E429-459F-8B34-DDED55F5590B", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29EA60BF-FBA6-4305-8173-07130A527410", "versionEndExcluding": "1.0.1.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB7B08B9-07D2-4404-846A-D1CA02C16557", "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC332E60-A7DB-41C5-B1ED-FE3EDF83F8BC", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EA5FF68-8609-4692-8DBF-A12606882BE5", "versionEndExcluding": "1.2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE2B75FA-179C-41A9-B5A3-26EFF452EA0B", "versionEndExcluding": "1.0.1.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D21ACC48-8B3D-4A0B-BA04-C9709835A66A", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6BA926B-4B26-4478-837A-A3B2DE734392", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B89AB47-7117-4FA7-B8F1-36D0C281C403", "versionEndExcluding": "1.2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "819CC65F-F5DA-4620-BC68-CAAA2B73195D", "versionEndExcluding": "1.0.9.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F0C755C-3012-440E-BE85-D98D41F54ED9", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "833A98AF-A4B0-4C68-AACD-6B3F58E64060", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D264AB39-63DD-4B32-9A91-D86A3700733D", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "29B13F94-F151-4F00-95C3-D9FB22B3CC2B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56014B19-02F8-4942-9889-7F3A4EB8F106", "versionEndExcluding": "1.0.0.112", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98819AD-045F-45AE-9579-258E41882CD9", "versionEndExcluding": "1.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3255D316-04E5-4056-BFFF-38B042167A74", "versionEndExcluding": "1.0.2.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A98DFA81-D1BA-41AE-A6A3-1EBBFC452D0F", "versionEndExcluding": "1.0.1.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7393D4D7-F607-423E-917E-FE520D7A3A73", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAAB159C-27F2-4645-9FE4-4DBB4465DE3A", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A79D8A77-4555-4B2A-8F19-F69AD4A17D2E", "versionEndExcluding": "1.0.2.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1664969-D326-4EC5-BF0D-E43820CCB378", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF8551B9-72D9-46B8-9F66-EE7841E29A26", "versionEndExcluding": "1.0.1.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*", "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7CE20879-71BC-433E-A8B0-D1004A016B34", "versionEndExcluding": "1.2.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by an attacker\u0027s ability to read arbitrary files. This affects D6220 before 1.0.0.40, D6400 before 1.0.0.74, D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, DGN2200v4 before 1.0.0.94, DGN2200Bv4 before 1.0.0.94, EX6200v2 before 1.0.1.50, EX7000 before 1.0.0.56, JR6150 before 1.0.1.18, R6050 before 1.0.1.10J, R6100 before 1.0.1.16, R6150 before 1.0.1.10, R6220 before 1.1.0.50, R6250 before 1.0.4.12, R6300v2 before 1.0.4.12, R6400 before 1.0.1.24, R6400v2 before 1.0.2.32, R6700 before 1.0.1.26, R6700v2 before 1.2.0.4, R6800 before 1.0.1.10, R6900 before 1.0.1.26, R6900P before 1.0.0.58, R6900v2 before 1.2.0.4, R7000 before 1.0.9.6, R7000P before 1.0.0.58, R7100LG before 1.0.0.32, R7300 before 1.0.0.54, R7500 before 1.0.0.112, R7500v2 before 1.0.3.20, R7800 before 1.0.2.36, R7900 before 1.0.1.18, R8000 before 1.0.3.48, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.40, WNDR3400v3 before 1.0.1.14, WNDR3700v4 before 1.0.2.96, WNDR4300v1 before 1.0.2.98, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR3500Lv2 before 1.2.0.44." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una capacidad del atacante para leer archivos arbitrarios. Esto afecta a D6220 versiones anteriores a 1.0.0.40, D6400 versiones anteriores a 1.0.0.74, D7000 versiones anteriores a 1.0.1.60, D7800 versiones anteriores a 1.0.1.34, D8500 versiones anteriores a 1.0.3.39, DGN2200v4 versiones anteriores a 1.0.0.94, DGN2200Bv4 versiones anteriores a 1.0.0.94, EX6200v2 versiones anteriores a 1.0.1.50, EX7000 versiones anteriores a 1.0.0.56, JR6150 versiones anteriores a 1.0.1.18, R6050 versiones anteriores a 1.0.1.10J, R6100 versiones anteriores a 1.0.1.16, R6150 versiones anteriores a 1.0.1.10, R6220 versiones anteriores a 1.1.0.50, R6250 versiones anteriores a 1.0.4.12, R6300v2 versiones anteriores a 1.0.4.12, R6400 versiones anteriores a 1.0.1.24, R6400v2 versiones anteriores a 1.0.2.32, R6700 versiones anteriores a 1.0.1.26, R6700v2 versiones anteriores a 1.2.0.4, R6800 versiones anteriores a 1.0.1.10, R6900 versiones anteriores a 1.0.1.26, R6900P versiones anteriores a 1.0.0.58, R6900v2 versiones anteriores a 1.2.0.4, R7000 versiones anteriores a 1.0 .9.6, R7000P versiones anteriores a 1.0.0.58, R7100LG versiones anteriores a 1.0.0.32, R7300 versiones anteriores a 1.0.0.54, R7500 versiones anteriores a 1.0.0.112, R7500v2 versiones anteriores a 1.0.3.20, R7800 versiones anteriores a 1.0.2.36, R7900 versiones anteriores a 1.0.1.18, R8000 versiones anteriores a 1.0.3.48 , R8300 versiones anteriores a 1.0.2.104, R8500 versiones anteriores a 1.0.2.104, R9000 versiones anteriores a 1.0.2.40, WNDR3400v3 versiones anteriores a 1.0.1.14, WNDR3700v4 versiones anteriores a 1.0.2.96, WNDR4300v1 versiones anteriores a 1.0.2.98, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR3500Lv2 versiones anteriores a 1.2.0.44." } ], "id": "CVE-2017-18769", "lastModified": "2024-11-21T03:20:52.507", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-22T15:15:11.457", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051474/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0122" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000051474/Security-Advisory-for-Arbitrary-File-Read-on-Some-Routers-Gateways-and-Extenders-PSV-2016-0122" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-21 21:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects DM200 before 1.0.0.52, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.16, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7DEE689F-923A-414C-B048-E4716DA2B783", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5", "versionEndExcluding": "1.0.2.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26", "versionEndExcluding": "1.0.3.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93C7D5A8-3B1D-4DCD-ACB6-8629CE598C25", "versionEndExcluding": "1.0.3.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E", "versionEndExcluding": "1.0.2.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F", "versionEndExcluding": "1.0.2.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects DM200 before 1.0.0.52, R7500 before 1.0.0.122, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.16, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a DM200 en versiones anteriores a la 1.0.0.52, R7500 en versiones anteriores a la 1.0.0.122, R7800 en versiones anteriores a la 1.0.2.42, R8900 en versiones anteriores a la 1.0.3.10, R9000 en versiones anteriores a la 1.0.3. 16, WNDR3700v4 en versiones anteriores a la 1.0.2.96, WNDR4300 en versiones anteriores a la 1.0.2.98, WNDR4300v2 en versiones anteriores a la 1.0.0.54, WNDR4500v3 en versiones anteriores a la 1.0.0.54, y WNR2000v5 en versiones anteriores a la 1.0.0.64." } ], "id": "CVE-2018-21144", "lastModified": "2024-11-21T04:03:00.497", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-21T21:15:12.867", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059489/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3166" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000059489/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-3166" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 15:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | r6100_firmware | * | |
netgear | r6100 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76B12C31-83C3-427F-B2CA-D75EA89DCC6F", "versionEndExcluding": "1.0.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF", "versionEndExcluding": "1.0.0.122", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C38F66ED-C53D-40F4-9F1E-96254BCD8A0C", "versionEndExcluding": "1.0.3.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2E62164-2324-4AF2-B300-8005DAD433B6", "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1425F7B0-0990-43F4-9621-8DAE8508FEED", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA", "versionEndExcluding": "1.0.0.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R6100 before 1.0.1.20, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, D7800 versiones anteriores a 1.0.1.34, R6100 versiones anteriores a 1.0.1.20, R7500 versiones anteriores a 1.0.0.122, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1. 0.2.40, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21193", "lastModified": "2024-11-21T04:03:08.457", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T15:15:12.770", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055164/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2602" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055164/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2602" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-28 16:15
Modified
2024-11-21 04:03
Severity ?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.2.0.44, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.62.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d6100_firmware | * | |
netgear | d6100 | - | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wndr3700_firmware | * | |
netgear | wndr3700 | v4 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | - | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583", "versionEndExcluding": "1.0.0.57", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE1B60E4-C8FA-4094-9F05-1746A01557D9", "versionEndExcluding": "1.0.2.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679AAEA7-6415-4BBA-AE95-887C2CA609DC", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A3C8B6-51A9-49BC-8C82-01269519B652", "versionEndExcluding": "1.0.2.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD8DCD-C187-4F15-9828-F302295199BA", "versionEndExcluding": "1.0.2.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27B33A47-E305-43CC-9AC2-C35DE8E51F02", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, R7800 before 1.2.0.44, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.62." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.57, R7800 versiones anteriores a 1.2.0.44, R9000 versiones anteriores a 1.0.2.52, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.54, WNDR4500v3 versiones anteriores a 1.0.0.54, y WNR2000v5 versiones anteriores a 1.0.0.62." } ], "id": "CVE-2018-21198", "lastModified": "2024-11-21T04:03:09.237", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:13.090", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055151/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2594" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000055151/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2594" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d3600_firmware | * | |
netgear | d3600 | - | |
netgear | d6000_firmware | * | |
netgear | d6000 | - | |
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | dm200_firmware | * | |
netgear | dm200 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | rbk20_firmware | * | |
netgear | rbk20 | - | |
netgear | rbr20_firmware | * | |
netgear | rbr20 | - | |
netgear | rbs20_firmware | * | |
netgear | rbs20 | - | |
netgear | rbk50_firmware | * | |
netgear | rbk50 | - | |
netgear | rbr50_firmware | * | |
netgear | rbr50 | - | |
netgear | rbs50_firmware | * | |
netgear | rbs50 | - | |
netgear | rbs40_firmware | * | |
netgear | rbs40 | - | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03798255-94BA-427C-8B2D-0861CD5FF730", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAE7FDE8-A375-4E10-9A57-F93C35FCF694", "versionEndExcluding": "1.0.3.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52E997BC-B5C7-4FBA-9535-6A0BA398F8C3", "versionEndExcluding": "1.0.2.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "712E83F9-2AC9-45B1-B0D6-E780CB8D9365", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850B682D-1D78-489A-8988-5D588EB975AC", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B0AB512-7926-4D78-87A2-FFBD56F7D2CA", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F58362EC-24C5-4EC3-9475-328469DABFD2", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B49E5051-D9AF-4852-8BDF-6F9C61CB5519", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F1FE395-0B10-4AA8-A178-D87E93CFA5D5", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8517632E-5C50-4A30-A9EE-7205A014619F", "versionEndExcluding": "2.3.0.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D7800 versiones anteriores a 1.0.1.44, DM200 versiones anteriores a 1.0.0.58, R7500v2 versiones anteriores a 1.0.3. 40, R7800 versiones anteriores a 1.0.2.60, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, RBK20 versiones anteriores a 2.3.0.22, RBR20 versiones anteriores a 2.3.0.22, RBS20 versiones anteriores a 2.3.0. 22, RBK50 versiones anteriores a 2.3.0.22, RBR50 versiones anteriores a 2.3.0.22, RBS50 versiones anteriores a 2.3.0.22, RBS40 versiones anteriores a 2.3.0.22, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1. 0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68." } ], "id": "CVE-2019-20714", "lastModified": "2024-11-21T04:39:09.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:24.777", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-04-16 19:15
Modified
2024-11-21 04:39
Severity ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
netgear | d7800_firmware | * | |
netgear | d7800 | - | |
netgear | ex2700_firmware | * | |
netgear | ex2700 | - | |
netgear | ex6100_firmware | * | |
netgear | ex6100 | v2 | |
netgear | ex6150_firmware | * | |
netgear | ex6150 | v2 | |
netgear | ex6200_firmware | * | |
netgear | ex6200 | v2 | |
netgear | ex6400_firmware | * | |
netgear | ex6400 | - | |
netgear | ex7300_firmware | * | |
netgear | ex7300 | - | |
netgear | r7500_firmware | * | |
netgear | r7500 | v2 | |
netgear | r7800_firmware | * | |
netgear | r7800 | - | |
netgear | r8900_firmware | * | |
netgear | r8900 | - | |
netgear | r9000_firmware | * | |
netgear | r9000 | - | |
netgear | wn2000rpt_firmware | * | |
netgear | wn2000rpt | v3 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v2 | |
netgear | wn3000rp_firmware | * | |
netgear | wn3000rp | v3 | |
netgear | wn3100rp_firmware | * | |
netgear | wn3100rp | v2 | |
netgear | wndr4300_firmware | * | |
netgear | wndr4300 | v2 | |
netgear | wndr4500_firmware | * | |
netgear | wndr4500 | v3 | |
netgear | xr450_firmware | * | |
netgear | xr450 | - | |
netgear | xr500_firmware | * | |
netgear | xr500 | - | |
netgear | wnr2000_firmware | * | |
netgear | wnr2000 | v5 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEF729AE-1D95-448C-80FA-8FAE723C1EC3", "versionEndExcluding": "1.0.1.47", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "733650A8-D797-43B2-851E-1B364C9E7100", "versionEndExcluding": "1.0.1.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC89483B-6D99-4A1B-A513-B50EA44DA963", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "542F7529-27DB-41F1-A8E4-FA7A596E5DCC", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3223C7E1-06DF-4CAA-89DD-611435165F49", "versionEndExcluding": "1.0.1.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*", "matchCriteriaId": "B4F62287-CB55-4FB1-AA39-62018654BA39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0A1B4BD-9DD6-4999-B0FA-F843713C991F", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2138C164-530B-4F97-8107-035F9D0852B0", "versionEndExcluding": "1.0.2.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "317AE6B1-BA33-49DF-A839-A49C5493996E", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*", "matchCriteriaId": "6FB1BE0D-E3CF-4C16-8C11-706B238E9934", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A480981E-57ED-47E3-B9AB-190E4783DC04", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "804E18F1-4621-4650-9015-49A9137A0C39", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F3D02E3-8FA1-4129-A4B2-25235AF0E49C", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D7800 versiones anteriores a 1.0.1.47, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7300 versiones anteriores a 1.0.2.136, R7500v2 versiones anteriores a 1.0.3.38, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4. 12, R9000 versiones anteriores a 1.0.4.12, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0. 66, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.66, XR450 versiones anteriores a 2.3.2.32, y XR500 versiones anteriores a 2.3.2.32." } ], "id": "CVE-2019-20721", "lastModified": "2024-11-21T04:39:10.943", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-16T19:15:25.227", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }