All the vulnerabilites related to elecom - wrc-f300nf
var-202102-0486
Vulnerability from variot
Cross-site scripting vulnerability in ELECOM WRC-300FEBK-A allows remote authenticated attackers to inject arbitrary script via unspecified vectors. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-A is a wireless access device.
ELECOM WRC-300FEBK-A has a cross-site scripting vulnerability. Attackers can use the vulnerability to inject malicious scripts or HTML code. A remote attacker could exploit this vulnerability to inject malicious script into a Web page which would be executed in a victim's Web browser within the security context of the hosting Web site, once the page is viewed. An attacker could use this vulnerability to steal the victim's cookie-based authentication credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0486", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wrc-300febk-a", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20645" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:wrc-300febk-a_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:wrc-300febk-a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20645" } ] }, "cve": "CVE-2021-20645", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CNVD-2021-14147", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.3, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20645", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14147", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2402", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20645" }, { "db": "CNNVD", "id": "CNNVD-202101-2402" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site scripting vulnerability in ELECOM WRC-300FEBK-A allows remote authenticated attackers to inject arbitrary script via unspecified vectors. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-A is a wireless access device. \n\r\n\r\nELECOM WRC-300FEBK-A has a cross-site scripting vulnerability. Attackers can use the vulnerability to inject malicious scripts or HTML code. A remote attacker could exploit this vulnerability to inject malicious script into a Web page which would be executed in a victim\u0027s Web browser within the security context of the hosting Web site, once the page is viewed. An attacker could use this vulnerability to steal the victim\u0027s cookie-based authentication credentials", "sources": [ { "db": "NVD", "id": "CVE-2021-20645" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "VULMON", "id": "CVE-2021-20645" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20645", "trust": 3.1 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14147", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2402", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-20645", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "VULMON", "id": "CVE-2021-20645" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20645" }, { "db": "CNNVD", "id": "CNNVD-202101-2402" } ] }, "id": "VAR-202102-0486", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" } ] }, "last_update_date": "2023-12-18T12:16:29.564000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM WRC-300FEBK-A cross-site scripting vulnerability (CNVD-2021-14147)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250596" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.8 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-352", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20645" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20645" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195679" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "VULMON", "id": "CVE-2021-20645" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20645" }, { "db": "CNNVD", "id": "CNNVD-202101-2402" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14147" }, { "db": "VULMON", "id": "CVE-2021-20645" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20645" }, { "db": "CNNVD", "id": "CNNVD-202101-2402" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14147" }, { "date": "2021-02-12T00:00:00", "db": "VULMON", "id": "CVE-2021-20645" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.137000", "db": "NVD", "id": "CVE-2021-20645" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2402" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14147" }, { "date": "2021-02-15T00:00:00", "db": "VULMON", "id": "CVE-2021-20645" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-15T01:37:56.010000", "db": "NVD", "id": "CVE-2021-20645" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2402" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2402" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2402" } ], "trust": 0.6 } }
var-202102-0489
Vulnerability from variot
ELECOM WRC-300FEBK-S allows an attacker with administrator rights to execute arbitrary OS commands via unspecified vectors. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-S is a wireless access device.
ELECOM WRC-300FEBK-S has an arbitrary command execution vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0489", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wrc-300febk-s", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-s", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20648" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:wrc-300febk-s_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:wrc-300febk-s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20648" } ] }, "cve": "CVE-2021-20648", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "id": "CNVD-2021-14145", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20648", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14145", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202101-2396", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20648" }, { "db": "CNNVD", "id": "CNNVD-202101-2396" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ELECOM WRC-300FEBK-S allows an attacker with administrator rights to execute arbitrary OS commands via unspecified vectors. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-S is a wireless access device. \n\r\n\r\nELECOM WRC-300FEBK-S has an arbitrary command execution vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2021-20648" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "VULMON", "id": "CVE-2021-20648" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20648", "trust": 3.1 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14145", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2396", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-20648", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "VULMON", "id": "CVE-2021-20648" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20648" }, { "db": "CNNVD", "id": "CNNVD-202101-2396" } ] }, "id": "VAR-202102-0489", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" } ] }, "last_update_date": "2023-12-18T12:16:29.599000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM WRC-300FEBK-S arbitrary command execution vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250601" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-352", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20648" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20648" }, { "trust": 0.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195666" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "VULMON", "id": "CVE-2021-20648" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20648" }, { "db": "CNNVD", "id": "CNNVD-202101-2396" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14145" }, { "db": "VULMON", "id": "CVE-2021-20648" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20648" }, { "db": "CNNVD", "id": "CNNVD-202101-2396" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14145" }, { "date": "2021-02-12T00:00:00", "db": "VULMON", "id": "CVE-2021-20648" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.327000", "db": "NVD", "id": "CVE-2021-20648" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2396" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14145" }, { "date": "2021-02-15T00:00:00", "db": "VULMON", "id": "CVE-2021-20648" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-15T01:29:13.357000", "db": "NVD", "id": "CVE-2021-20648" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2396" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2396" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2396" } ], "trust": 0.6 } }
var-202102-0490
Vulnerability from variot
ELECOM WRC-300FEBK-S contains an improper certificate validation vulnerability. Via a man-in-the-middle attack, an attacker may alter the communication response. As a result, an arbitrary OS command may be executed on the affected device. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. ELECOM WRC-300FEBK-S is a network camera suitable for home from Elecom of Japan. Attackers can use this vulnerability to change the communication response and execute arbitrary commands on the product
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0490", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wrc-300febk-s", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-s", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20649" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:wrc-300febk-s_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:wrc-300febk-s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20649" } ] }, "cve": "CVE-2021-20649", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 4.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2021-14142", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.2, "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20649", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14142", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2390", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20649" }, { "db": "CNNVD", "id": "CNNVD-202101-2390" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ELECOM WRC-300FEBK-S contains an improper certificate validation vulnerability. Via a man-in-the-middle attack, an attacker may alter the communication response. As a result, an arbitrary OS command may be executed on the affected device. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. ELECOM WRC-300FEBK-S is a network camera suitable for home from Elecom of Japan. Attackers can use this vulnerability to change the communication response and execute arbitrary commands on the product", "sources": [ { "db": "NVD", "id": "CVE-2021-20649" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "VULMON", "id": "CVE-2021-20649" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20649", "trust": 3.1 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14142", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2390", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-20649", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "VULMON", "id": "CVE-2021-20649" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20649" }, { "db": "CNNVD", "id": "CNNVD-202101-2390" } ] }, "id": "VAR-202102-0490", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" } ] }, "last_update_date": "2023-12-18T12:16:29.627000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM WRC-300FEBK-S certificate verification error vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250616" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-295", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-352", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20649" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20649" }, { "trust": 0.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195680" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "VULMON", "id": "CVE-2021-20649" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20649" }, { "db": "CNNVD", "id": "CNNVD-202101-2390" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14142" }, { "db": "VULMON", "id": "CVE-2021-20649" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20649" }, { "db": "CNNVD", "id": "CNNVD-202101-2390" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14142" }, { "date": "2021-02-12T00:00:00", "db": "VULMON", "id": "CVE-2021-20649" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.387000", "db": "NVD", "id": "CVE-2021-20649" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2390" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14142" }, { "date": "2021-02-15T00:00:00", "db": "VULMON", "id": "CVE-2021-20649" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-15T01:26:09.573000", "db": "NVD", "id": "CVE-2021-20649" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2390" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2390" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "trust management problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2390" } ], "trust": 0.6 } }
var-202102-0484
Vulnerability from variot
Improper access control vulnerability in ELECOM LD-PS/U1 allows remote attackers to change the administrative password of the affected device by processing a specially crafted request. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM LD-PS/U1 is a USB print server.
ELECOM LD-PS/U1 has an access control error vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0484", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ld-ps\\/u1", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "ld-ps/u1", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20643" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:ld-ps\\/u1_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:ld-ps\\/u1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20643" } ] }, "cve": "CVE-2021-20643", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-14143", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20643", "trust": 1.0, "value": "HIGH" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14143", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2407", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20643" }, { "db": "CNNVD", "id": "CNNVD-202101-2407" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Improper access control vulnerability in ELECOM LD-PS/U1 allows remote attackers to change the administrative password of the affected device by processing a specially crafted request. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM LD-PS/U1 is a USB print server. \n\r\n\r\nELECOM LD-PS/U1 has an access control error vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2021-20643" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14143" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "JVN", "id": "JVN47580234", "trust": 3.0 }, { "db": "NVD", "id": "CVE-2021-20643", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14143", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2407", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20643" }, { "db": "CNNVD", "id": "CNNVD-202101-2407" } ] }, "id": "VAR-202102-0484", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" } ] }, "last_update_date": "2023-12-18T12:16:29.429000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM LD-PS/U1 access control error vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250611" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-Other", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-352", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20643" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 1.6, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20643" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14143" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20643" }, { "db": "CNNVD", "id": "CNNVD-202101-2407" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14143" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20643" }, { "db": "CNNVD", "id": "CNNVD-202101-2407" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14143" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:14.997000", "db": "NVD", "id": "CVE-2021-20643" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2407" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14143" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-20643" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2407" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2407" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2407" } ], "trust": 0.6 } }
var-202102-0488
Vulnerability from variot
Cross-site request forgery (CSRF) vulnerability in ELECOM WRC-300FEBK-S allows remote attackers to hijack the authentication of administrators and execute an arbitrary request via unspecified vector. As a result, the device settings may be altered and/or telnet daemon may be started. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-S is a wireless access device
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0488", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wrc-300febk-s", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-s", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20647" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:wrc-300febk-s_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:wrc-300febk-s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20647" } ] }, "cve": "CVE-2021-20647", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CNVD-2021-14144", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20647", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14144", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2395", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20647" }, { "db": "CNNVD", "id": "CNNVD-202101-2395" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site request forgery (CSRF) vulnerability in ELECOM WRC-300FEBK-S allows remote attackers to hijack the authentication of administrators and execute an arbitrary request via unspecified vector. As a result, the device settings may be altered and/or telnet daemon may be started. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-S is a wireless access device", "sources": [ { "db": "NVD", "id": "CVE-2021-20647" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14144" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20647", "trust": 3.0 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14144", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2395", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20647" }, { "db": "CNNVD", "id": "CNNVD-202101-2395" } ] }, "id": "VAR-202102-0488", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" } ] }, "last_update_date": "2023-12-18T12:16:29.538000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM WRC-300FEBK-S cross-site request forgery vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250606" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.8 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20647" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20647" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14144" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20647" }, { "db": "CNNVD", "id": "CNNVD-202101-2395" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14144" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20647" }, { "db": "CNNVD", "id": "CNNVD-202101-2395" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14144" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.263000", "db": "NVD", "id": "CVE-2021-20647" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2395" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14144" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-15T01:32:12.643000", "db": "NVD", "id": "CVE-2021-20647" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2395" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2395" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2395" } ], "trust": 0.6 } }
var-202102-0485
Vulnerability from variot
ELECOM WRC-1467GHBK-A allows arbitrary scripts to be executed on the user's web browser by displaying a specially crafted SSID on the web setup page. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-1467GHBK-A is a wireless access device.
ELECOM WRC-1467GHBK-A has a cross-site scripting vulnerability. Attackers can use the vulnerability to inject malicious scripts or HTML code
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0485", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-1467ghbk-a", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20644" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:wrc-1467ghbk-a_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:wrc-1467ghbk-a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20644" } ] }, "cve": "CVE-2021-20644", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CNVD-2021-14146", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20644", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14146", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2404", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20644" }, { "db": "CNNVD", "id": "CNNVD-202101-2404" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ELECOM WRC-1467GHBK-A allows arbitrary scripts to be executed on the user\u0027s web browser by displaying a specially crafted SSID on the web setup page. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-1467GHBK-A is a wireless access device. \n\r\n\r\nELECOM WRC-1467GHBK-A has a cross-site scripting vulnerability. Attackers can use the vulnerability to inject malicious scripts or HTML code", "sources": [ { "db": "NVD", "id": "CVE-2021-20644" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "VULMON", "id": "CVE-2021-20644" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20644", "trust": 3.1 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14146", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2404", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-20644", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "VULMON", "id": "CVE-2021-20644" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20644" }, { "db": "CNNVD", "id": "CNNVD-202101-2404" } ] }, "id": "VAR-202102-0485", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" } ] }, "last_update_date": "2023-12-18T12:16:29.402000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM WRC-1467GHBK-A cross-site scripting vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250586" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-74", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-352", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20644" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20644" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/195675" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "VULMON", "id": "CVE-2021-20644" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20644" }, { "db": "CNNVD", "id": "CNNVD-202101-2404" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14146" }, { "db": "VULMON", "id": "CVE-2021-20644" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20644" }, { "db": "CNNVD", "id": "CNNVD-202101-2404" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14146" }, { "date": "2021-02-12T00:00:00", "db": "VULMON", "id": "CVE-2021-20644" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.060000", "db": "NVD", "id": "CVE-2021-20644" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2404" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14146" }, { "date": "2021-02-18T00:00:00", "db": "VULMON", "id": "CVE-2021-20644" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-18T20:33:26.253000", "db": "NVD", "id": "CVE-2021-20644" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2404" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2404" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2404" } ], "trust": 0.6 } }
var-201505-0274
Vulnerability from variot
The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023. WSR-300HP provided by BUFFALO INC. contains an arbitrary code execution vulnerability. WSR-300HP provided by BUFFALO INC. is a wireless LAN router. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. Authentication is not required to exploit this vulnerability.The specific flaw exists within the miniigd SOAP service. The issue lies in the handling of the NewInternalClient requests due to a failure to sanitize user data before executing a system call. An attacker could leverage this vulnerability to execute code with root privileges. Failed exploit attempts will result in a denial-of-service condition. Realtek SDK is a set of SDK development kit developed by Realtek
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201505-0274", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "dir-619l", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "1.00" }, { "model": "dir-605l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "1.13" }, { "model": "dir-619l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "2.03" }, { "model": "dir-605l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "2.04" }, { "model": "dir-600l", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "2.00" }, { "model": "dir-600l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "2.05" }, { "model": "dir-605l", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "2.00" }, { "model": "dir-605l", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "1.00" }, { "model": "dir-600l", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "1.00" }, { "model": "dir-600l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "1.15" }, { "model": "dir-619l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "1.15" }, { "model": "dir-809", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "1.02" }, { "model": "sdk", "scope": "eq", "trust": 1.0, "vendor": "realtek", "version": null }, { "model": "dir-905l", "scope": "lte", "trust": 1.0, "vendor": "dlink", "version": "1.02" }, { "model": "dir-619l", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "2.00" }, { "model": "dir-809", "scope": "gte", "trust": 1.0, "vendor": "dlink", "version": "1.00" }, { "model": "wsr-300hp", "scope": "lte", "trust": 0.8, "vendor": "buffalo", "version": "firmware 2.30" }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "dir-600l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "a1 ( firmware 1.15 )" }, { "model": "dir-600l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "b1 ( firmware 2.056b06 )" }, { "model": "dir-600l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "1.15" }, { "model": "dir-600l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "2.056b06" }, { "model": "dir-605l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "a1 ( firmware 1.14b06 )" }, { "model": "dir-605l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "bx ( firmware 2.07b02 )" }, { "model": "dir-605l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "c1 ( firmware 3.03b07 )" }, { "model": "dir-605l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "1.14b06" }, { "model": "dir-605l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "2.07b02" }, { "model": "dir-605l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "3.03b07" }, { "model": "dir-619l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "a1 ( firmware 1.15 )" }, { "model": "dir-619l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "b1 ( firmware 2.07b02 )" }, { "model": "dir-619l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "1.15" }, { "model": "dir-619l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "2.07b02" }, { "model": "dir-809", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "a1 ( firmware 1.04b02 )" }, { "model": "dir-809", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "a2 ( firmware 1.04b02 )" }, { "model": "dir-809", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "1.04b02" }, { "model": "dir-900l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "a1 ( firmware 1.14b02 )" }, { "model": "dir-900l", "scope": "lte", "trust": 0.8, "vendor": "d link", "version": "1.14b02" }, { "model": "sdk", "scope": null, "trust": 0.8, "vendor": "realtek semiconductor corp", "version": null }, { "model": "rtl81xx sdk", "scope": null, "trust": 0.7, "vendor": "realtek", "version": null }, { "model": "dir-600l", "scope": "eq", "trust": 0.6, "vendor": "d link", "version": "1.15" }, { "model": "dir-600l", "scope": "eq", "trust": 0.6, "vendor": "d link", "version": "2.05" }, { "model": "dir-905l", "scope": "eq", "trust": 0.6, "vendor": "d link", "version": "1.02" }, { "model": "dir-605l", "scope": "eq", "trust": 0.6, "vendor": "d link", "version": "1.13" }, { "model": "dir-605l", "scope": "eq", "trust": 0.6, "vendor": "d link", "version": "2.04" } ], "sources": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "CNNVD", "id": "CNNVD-201504-581" }, { "db": "NVD", "id": "CVE-2014-8361" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:dlink:dir-905l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.02", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:dlink:dir-905l:a1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:dlink:dir-605l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.13", "versionStartIncluding": "1.00", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:dlink:dir-605l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.04", "versionStartIncluding": "2.00", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:dlink:dir-605l:a1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:dlink:dir-605l:b1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:dlink:dir-600l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.15", "versionStartIncluding": "1.00", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:dlink:dir-600l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.05", "versionStartIncluding": "2.00", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:dlink:dir-600l:a1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:dlink:dir-600l:b1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:realtek:realtek_sdk:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:dlink:dir-619l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.15", "versionStartIncluding": "1.00", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:dlink:dir-619l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.03", "versionStartIncluding": "2.00", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:dlink:dir-619l:a1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:dlink:dir-619l:b1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.02", "versionStartIncluding": "1.00", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:dlink:dir-809:a1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:dlink:dir-809:a2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2014-8361" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Ricky \"HeadlessZeke\" Lawshae", "sources": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "BID", "id": "74330" }, { "db": "CNNVD", "id": "CNNVD-201504-581" } ], "trust": 1.6 }, "cve": "CVE-2014-8361", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2014-8361", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 1.6, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2017-000194", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-76306", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2017-000194", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2014-8361", "trust": 1.8, "value": "HIGH" }, { "author": "IPA", "id": "JVNDB-2017-000194", "trust": 0.8, "value": "High" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2014-8361", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201504-581", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-76306", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2014-8361", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "VULHUB", "id": "VHN-76306" }, { "db": "VULMON", "id": "CVE-2014-8361" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "CNNVD", "id": "CNNVD-201504-581" }, { "db": "NVD", "id": "CVE-2014-8361" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023. WSR-300HP provided by BUFFALO INC. contains an arbitrary code execution vulnerability. WSR-300HP provided by BUFFALO INC. is a wireless LAN router. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. Authentication is not required to exploit this vulnerability.The specific flaw exists within the miniigd SOAP service. The issue lies in the handling of the NewInternalClient requests due to a failure to sanitize user data before executing a system call. An attacker could leverage this vulnerability to execute code with root privileges. Failed exploit attempts will result in a denial-of-service condition. Realtek SDK is a set of SDK development kit developed by Realtek", "sources": [ { "db": "NVD", "id": "CVE-2014-8361" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "BID", "id": "74330" }, { "db": "VULHUB", "id": "VHN-76306" }, { "db": "VULMON", "id": "CVE-2014-8361" } ], "trust": 4.14 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-76306", "trust": 0.1, "type": "unknown" }, { "reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=37169", "trust": 0.1, "type": "exploit" } ], "sources": [ { "db": "VULHUB", "id": "VHN-76306" }, { "db": "VULMON", "id": "CVE-2014-8361" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2014-8361", "trust": 5.2 }, { "db": "ZDI", "id": "ZDI-15-155", "trust": 3.6 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.6 }, { "db": "BID", "id": "74330", "trust": 2.1 }, { "db": "DLINK", "id": "SAP10055", "trust": 2.1 }, { "db": "JVN", "id": "JVN67456944", "trust": 1.8 }, { "db": "EXPLOIT-DB", "id": "37169", "trust": 1.8 }, { "db": "PACKETSTORM", "id": "132090", "trust": 1.8 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "JVN", "id": "JVN74871939", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-000194", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2014-008039", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-2435", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-201504-581", "trust": 0.7 }, { "db": "JVNDB", "id": "JVNDB-2021-000028", "trust": 0.6 }, { "db": "SEEBUG", "id": "SSVID-97587", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-76306", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2014-8361", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "VULHUB", "id": "VHN-76306" }, { "db": "VULMON", "id": "CVE-2014-8361" }, { "db": "BID", "id": "74330" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "CNNVD", "id": "CNNVD-201504-581" }, { "db": "NVD", "id": "CVE-2014-8361" } ] }, "id": "VAR-201505-0274", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-76306" } ], "trust": 0.759098647142857 }, "last_update_date": "2024-04-18T13:16:59.233000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "BUFFALO INC. website", "trust": 0.8, "url": "http://buffalo.jp/support_s/s20170804_2.html" }, { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "RTL81xx", "trust": 0.8, "url": "http://www.realtek.com/search/default.aspx?keyword=rtl81" }, { "title": "SAP10055", "trust": 0.8, "url": "http://securityadvisories.dlink.com/security/publication.aspx?name=sap10055" }, { "title": "This vulnerability is being disclosed publicly without a patch in accordance with the ZDI vulnerability disclosure policy on lack of vendor response.Vendor Contact Timeline:08/13/2014 - ZDI wrote to vendor requesting contact and PGP09/04/2014 - ZDI wrote to vendor requesting contact and PGP09/29/2014 - ZDI wrote to vendor requesting contact and PGP10/22/2014 - ZDI wrote to vendor requesting contact and PGP, indicated \"final\" email attempt and informed of intent to 0-day04/24/2015 - Public release of advisory-- Mitigation:Given the stated purpose of Realtek SDK, and the nature of the vulnerability, the only salient mitigation strategy is to restrict interaction with the service to trusted machines. Only the clients and servers that have a legitimate procedural relationship with products using Realtek SDK service should be permitted to communicate with it. This could be accomplished in a number of ways, most notably with firewall rules/whitelisting. These features are available in the native Windows Firewall, as described in and numerous other Microsoft Knowledge Base articles.", "trust": 0.7, "url": "http://technet.microsoft.com/en-us/library/cc725770%28ws.10%29.aspx" }, { "title": "Realtek SDK miniigd SOAP Fixes for service remote code execution vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=96763" }, { "title": "", "trust": 0.1, "url": "https://github.com/xuguowong/mirai-mal " }, { "title": "api.greynoise.io", "trust": 0.1, "url": "https://github.com/greynoise-intelligence/api.greynoise.io " }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/keksec-simps-botnet-gaming-ddos/166306/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/gafgyt-botnet-ddos-mirai/165424/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/valve-source-engine-fortnite-servers-crippled-by-gafgyt-variant/149719/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/new-mirai-samples-grow-the-number-of-processors-targets/143566/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/huawei-router-default-credential/140234/" }, { "title": "BleepingComputer", "trust": 0.1, "url": "https://www.bleepingcomputer.com/news/security/router-crapfest-malware-author-builds-18-000-strong-botnet-in-a-day/" }, { "title": "Securelist", "trust": 0.1, "url": "https://securelist.com/threat-landscape-for-industrial-automation-systems-in-h2-2017/85053/" }, { "title": "BleepingComputer", "trust": 0.1, "url": "https://www.bleepingcomputer.com/news/security/new-jenx-iot-ddos-botnet-offered-part-of-gaming-server-rental-scheme/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/jenx-botnet-has-grand-theft-auto-hook/129759/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/satori-author-linked-to-new-mirai-variant-masuta/129640/" }, { "title": "BleepingComputer", "trust": 0.1, "url": "https://www.bleepingcomputer.com/news/security/satori-botnet-is-now-attacking-ethereum-mining-rigs/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/code-used-in-zero-day-huawei-router-attack-made-public/129260/" }, { "title": "BleepingComputer", "trust": 0.1, "url": "https://www.bleepingcomputer.com/news/security/amateur-hacker-behind-satori-botnet/" }, { "title": "Threatpost", "trust": 0.1, "url": "https://threatpost.com/unpatched-router-vulnerability-could-lead-to-code-execution/112524/" } ], "sources": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "VULMON", "id": "CVE-2014-8361" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "CNNVD", "id": "CNNVD-201504-581" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 }, { "problemtype": "CWE-94", "trust": 0.8 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-352", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-76306" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "NVD", "id": "CVE-2014-8361" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.9, "url": "http://www.zerodayinitiative.com/advisories/zdi-15-155/" }, { "trust": 2.4, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 2.1, "url": "http://securityadvisories.dlink.com/security/publication.aspx?name=sap10055" }, { "trust": 1.9, "url": "https://www.exploit-db.com/exploits/37169/" }, { "trust": 1.8, "url": "http://www.securityfocus.com/bid/74330" }, { "trust": 1.8, "url": "http://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 1.8, "url": "http://jvn.jp/en/jp/jvn67456944/index.html" }, { "trust": 1.8, "url": "http://packetstormsecurity.com/files/132090/realtek-sdk-miniigd-upnp-soap-command-execution.html" }, { "trust": 1.1, "url": "https://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/" }, { "trust": 1.1, "url": "https://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=sap10055" }, { "trust": 0.8, "url": "http://jvn.jp/en/jp/jvn74871939/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8361" }, { "trust": 0.7, "url": "http://technet.microsoft.com/en-us/library/cc725770%28ws.10%29.aspx" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000028.html" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.3, "url": "http://www.realtek.com.tw/contact/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/20.html" }, { "trust": 0.1, "url": "http://tools.cisco.com/security/center/viewalert.x?alertid=41532" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://threatpost.com/keksec-simps-botnet-gaming-ddos/166306/" } ], "sources": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "VULHUB", "id": "VHN-76306" }, { "db": "VULMON", "id": "CVE-2014-8361" }, { "db": "BID", "id": "74330" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "CNNVD", "id": "CNNVD-201504-581" }, { "db": "NVD", "id": "CVE-2014-8361" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-15-155" }, { "db": "VULHUB", "id": "VHN-76306" }, { "db": "VULMON", "id": "CVE-2014-8361" }, { "db": "BID", "id": "74330" }, { "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "db": "CNNVD", "id": "CNNVD-201504-581" }, { "db": "NVD", "id": "CVE-2014-8361" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-04-24T00:00:00", "db": "ZDI", "id": "ZDI-15-155" }, { "date": "2015-05-01T00:00:00", "db": "VULHUB", "id": "VHN-76306" }, { "date": "2015-05-01T00:00:00", "db": "VULMON", "id": "CVE-2014-8361" }, { "date": "2015-04-24T00:00:00", "db": "BID", "id": "74330" }, { "date": "2017-08-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2015-05-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "date": "2015-04-29T00:00:00", "db": "CNNVD", "id": "CNNVD-201504-581" }, { "date": "2015-05-01T15:59:01.287000", "db": "NVD", "id": "CVE-2014-8361" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-04-24T00:00:00", "db": "ZDI", "id": "ZDI-15-155" }, { "date": "2019-08-14T00:00:00", "db": "VULHUB", "id": "VHN-76306" }, { "date": "2023-09-05T00:00:00", "db": "VULMON", "id": "CVE-2014-8361" }, { "date": "2015-05-07T18:22:00", "db": "BID", "id": "74330" }, { "date": "2017-08-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-000194" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2015-05-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-008039" }, { "date": "2021-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201504-581" }, { "date": "2023-09-05T22:15:07.477000", "db": "NVD", "id": "CVE-2014-8361" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201504-581" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "WSR-300HP vulnerable to arbitrary code execution", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-000194" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "input validation error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201504-581" } ], "trust": 0.6 } }
var-202102-0491
Vulnerability from variot
Cross-site request forgery (CSRF) vulnerability in ELECOM NCC-EWF100RMWH2 allows remote attackers to hijack the authentication of administrators and execute an arbitrary request via unspecified vector. As a result, the device settings may be altered and/or telnet daemon may be started. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM NCC-EWF100RMWH2 is a wireless access device. Attackers can construct malicious URIs to induce requests and use this vulnerability to perform malicious operations in the context of the target user
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0491", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "ncc-ewf100rmwh2", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20650" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:ncc-ewf100rmwh2_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:ncc-ewf100rmwh2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20650" } ] }, "cve": "CVE-2021-20650", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CNVD-2021-14149", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20650", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14149", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2389", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20650" }, { "db": "CNNVD", "id": "CNNVD-202101-2389" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site request forgery (CSRF) vulnerability in ELECOM NCC-EWF100RMWH2 allows remote attackers to hijack the authentication of administrators and execute an arbitrary request via unspecified vector. As a result, the device settings may be altered and/or telnet daemon may be started. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM NCC-EWF100RMWH2 is a wireless access device. Attackers can construct malicious URIs to induce requests and use this vulnerability to perform malicious operations in the context of the target user", "sources": [ { "db": "NVD", "id": "CVE-2021-20650" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14149" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20650", "trust": 3.0 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14149", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2389", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20650" }, { "db": "CNNVD", "id": "CNNVD-202101-2389" } ] }, "id": "VAR-202102-0491", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" } ] }, "last_update_date": "2023-12-18T12:16:29.655000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM NCC-EWF100RMWH2 cross-site request forgery vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250591" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.8 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20650" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20650" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20650" }, { "db": "CNNVD", "id": "CNNVD-202101-2389" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20650" }, { "db": "CNNVD", "id": "CNNVD-202101-2389" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14149" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.450000", "db": "NVD", "id": "CVE-2021-20650" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2389" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14149" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-18T18:37:52.897000", "db": "NVD", "id": "CVE-2021-20650" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2389" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2389" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ELECOM NCC-EWF100RMWH2 cross-site request forgery vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-14149" }, { "db": "CNNVD", "id": "CNNVD-202101-2389" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2389" } ], "trust": 0.6 } }
var-202102-0487
Vulnerability from variot
Cross-site request forgery (CSRF) vulnerability in ELECOM WRC-300FEBK-A allows remote attackers to hijack the authentication of administrators and execute an arbitrary request via unspecified vector. As a result, the device settings may be altered and/or telnet daemon may be started. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. ・ Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 ・ Retractable cross-site scripting (CWE-79) - CVE-2021-20645 ・ Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 ・ UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 ・ Crafted SSID Is displayed on the management screen, and any script is executed on the user's web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 ・ Any third party who can access the product OS Command is executed - CVE-2021-20648 ・ Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 ・ With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-A is a wireless access device. Attackers can use the vulnerability to perform malicious operations in the context of the target user by constructing malicious URIs to induce requests
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0487", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wrc-300febk-a", "scope": "eq", "trust": 1.0, "vendor": "elecom", "version": null }, { "model": "ld-ps/u1", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20643)" }, { "model": "ncc-ewf100rmwh2", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20650)" }, { "model": "wrc-1467ghbk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20644)" }, { "model": "wrc-300febk", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20645, cve-2021-20646)" }, { "model": "wrc-300febk-s", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2021-20647, cve-2021-20648, cve-2021-20649, cve-2014-8361)" }, { "model": "wrc-f300nf", "scope": "eq", "trust": 0.8, "vendor": "elecom", "version": "(cve-2014-8361)" }, { "model": "wrc-300febk-a", "scope": null, "trust": 0.6, "vendor": "elecom", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20646" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:elecom:wrc-300febk-a_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:elecom:wrc-300febk-a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20646" } ] }, "cve": "CVE-2021-20646", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 2.6, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "IPA", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-14148", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.2, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.3, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2021-000008", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 4.8, "value": "Medium" }, { "author": "NVD", "id": "CVE-2021-20646", "trust": 1.0, "value": "MEDIUM" }, { "author": "IPA", "id": "JVNDB-2021-000008", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-14148", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2399", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20646" }, { "db": "CNNVD", "id": "CNNVD-202101-2399" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site request forgery (CSRF) vulnerability in ELECOM WRC-300FEBK-A allows remote attackers to hijack the authentication of administrators and execute an arbitrary request via unspecified vector. As a result, the device settings may be altered and/or telnet daemon may be started. The following multiple vulnerabilities exist in multiple products provided by ELECOM CORPORATION. \u30fb Inadequate access restrictions (CWE-284) - CVE-2021-20643 -Script injection on the management screen (CWE-74) - CVE-2021-20644 \u30fb Retractable cross-site scripting (CWE-79) - CVE-2021-20645 \u30fb Cross-site request forgery (CWE-352) - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb OS Command injection (CWE-78) - CVE-2021-20648 -Insufficient verification of server certificate (CWE-295) - CVE-2021-20649 \u30fb UPnP Via OS Command injection (CWE-78) - CVE-2014-8361 CVE-2021-20643 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Institute of Information Security Yuasa Laboratory Nagakawa ( Ishibashi ) Australia Mr CVE-2021-20644 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Sato Rei Mr CVE-2021-20645, CVE-2021-20646 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Mitsui Bussan Secure Direction Co., Ltd. Tetsuyuki Ogawa Mr CVE-2021-20647, CVE-2021-20648, CVE-2021-20649 These vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr CVE-2021-20650 This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Hiroshi Watanabe Mr CVE-2014-8361 The following person indicates that the product is vulnerable to IPA Report to JPCERT/CC Coordinated with the developer. Reporter : Cyber Defense Institute, Inc. Satoru Nagaoka Mr., National Institute of Information and Communications Technology Makita Daisuke Mr., National Institute of Information and Communications Technology Woods Yoshiki MrThe expected impact depends on each vulnerability, but it may be affected as follows. -The management password of the product is changed by processing the request crafted by a remote third party. - CVE-2021-20643 \u30fb Crafted SSID Is displayed on the management screen, and any script is executed on the user\u0027s web browser. - CVE-2021-20644 -Any script is executed on the web browser of the user who is logged in to the product. - CVE-2021-20645 -When a user logged in to the management screen of the product accesses a specially crafted page, an arbitrary request is executed, and as a result, the settings of the product are changed unintentionally. telnet Daemon is started - CVE-2021-20646, CVE-2021-20647, CVE-2021-20650 \u30fb Any third party who can access the product OS Command is executed - CVE-2021-20648 \u30fb Man-in-the-middle attack (man-in-the-middle attack) The communication response has been tampered with, resulting in arbitrary in the product. OS Command is executed - CVE-2021-20649 \u30fb With the product UPnP Is valid, any by a third party who has access to the product OS Command is executed - CVE-2014-8361. ELECOM WRC-300FEBK-A is a wireless access device. Attackers can use the vulnerability to perform malicious operations in the context of the target user by constructing malicious URIs to induce requests", "sources": [ { "db": "NVD", "id": "CVE-2021-20646" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "CNVD", "id": "CNVD-2021-14148" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20646", "trust": 3.0 }, { "db": "JVN", "id": "JVN47580234", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2021-000008", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2021-14148", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2399", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20646" }, { "db": "CNNVD", "id": "CNNVD-202101-2399" } ] }, "id": "VAR-202102-0487", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" } ], "trust": 1.299523826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "IoT" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" } ] }, "last_update_date": "2023-12-18T12:16:29.454000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "\u7121\u7ddaLAN\u30eb\u30fc\u30bf\u30fc\u306a\u3069\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u88fd\u54c1\u306e\u4e00\u90e8\u306b\u304a\u3051\u308b\u8106\u5f31\u6027\u306b\u95a2\u3057\u3066", "trust": 0.8, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "title": "Patch for ELECOM WRC-300FEBK-A cross-site request forgery vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/250581" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.8 }, { "problemtype": "CWE-78", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 }, { "problemtype": "CWE-79", "trust": 0.8 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20646" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://www.elecom.co.jp/news/security/20210126-01/" }, { "trust": 1.6, "url": "https://jvn.jp/en/jp/jvn47580234/index.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20649" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20650" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20643" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8361" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20644" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20645" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20646" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20647" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2021-20648" }, { "trust": 0.8, "url": "https://jvn.jp/jp/jvn47580234/index.html" }, { "trust": 0.6, "url": "https://jvndb.jvn.jp/en/contents/2021/jvndb-2021-000008.html" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20646" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-14148" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20646" }, { "db": "CNNVD", "id": "CNNVD-202101-2399" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-14148" }, { "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "db": "NVD", "id": "CVE-2021-20646" }, { "db": "CNNVD", "id": "CNNVD-202101-2399" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14148" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-12T07:15:15.200000", "db": "NVD", "id": "CVE-2021-20646" }, { "date": "2021-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2399" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-14148" }, { "date": "2021-01-26T03:12:23", "db": "JVNDB", "id": "JVNDB-2021-000008" }, { "date": "2021-02-15T01:36:18.557000", "db": "NVD", "id": "CVE-2021-20646" }, { "date": "2021-02-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2399" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2399" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple vulnerabilities in multiple ELECOM products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-000008" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2399" } ], "trust": 0.6 } }
cve-2023-43757
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:52:10.967Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.elecom.co.jp/news/security/20231114-01/" }, { "tags": [ "x_transferred" ], "url": "https://www.elecom.co.jp/news/security/20230810-01/" }, { "tags": [ "x_transferred" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU94119876/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WRC-2533GHBK2-T", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-2533GHBK-I", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1750GHBK2-I", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1750GHBK-E", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1750GHBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1167GHBK2", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1167GHBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-F1167ACF", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-733GHBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-733GHBK-I", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-733GHBK-C", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-300GHBK2-I", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-300GHBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-733FEBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-300FEBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-F300NF", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300WH-H", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300BK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300WH", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300RD", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300SV", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300BK-S", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300WH-S", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300BK2-S", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-300WH2-S", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-H300BK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-H300WH", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-150BK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRH-150WH", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "LAN-W300N/RS", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "LAN-W301NR", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "LAN-W300N/P", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "LAN-WH300N/DGP", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "LAN-WH300NDGPE", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Inadequate encryption strength vulnerability in multiple routers provided by ELECOM CO.,LTD. and LOGITEC CORPORATION allows a network-adjacent unauthenticated attacker to guess the encryption key used for wireless LAN communication and intercept the communication. As for the affected products/versions, see the information provided by the vendor under [References] section." } ], "problemTypes": [ { "descriptions": [ { "description": "Inadequate Encryption Strength", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-16T06:42:13.507Z", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "url": "https://www.elecom.co.jp/news/security/20231114-01/" }, { "url": "https://www.elecom.co.jp/news/security/20230810-01/" }, { "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "url": "https://jvn.jp/en/vu/JVNVU94119876/" } ] } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2023-43757", "datePublished": "2023-11-16T06:21:13.445Z", "dateReserved": "2023-10-31T07:10:40.728Z", "dateUpdated": "2024-08-02T19:52:10.967Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20739
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.elecom.co.jp/news/security/20210706-01/ | x_refsource_MISC | |
https://jvn.jp/en/vu/JVNVU94260088/index.html | x_refsource_MISC |
Vendor | Product | Version | |
---|---|---|---|
▼ | ELECOM CO.,LTD. | WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S, and WRH-300WH-S |
Version: all versions |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:53:21.835Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU94260088/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S, and WRH-300WH-S", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S, and WRH-300WH-S all versions allows an unauthenticated network-adjacent attacker to execute an arbitrary OS command via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "OS Command Injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-07T07:05:26", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/en/vu/JVNVU94260088/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2021-20739", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S, and WRH-300WH-S", "version": { "version_data": [ { "version_value": "all versions" } ] } } ] }, "vendor_name": "ELECOM CO.,LTD." } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S, and WRH-300WH-S all versions allows an unauthenticated network-adjacent attacker to execute an arbitrary OS command via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.elecom.co.jp/news/security/20210706-01/", "refsource": "MISC", "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "name": "https://jvn.jp/en/vu/JVNVU94260088/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/vu/JVNVU94260088/index.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2021-20739", "datePublished": "2021-07-07T07:05:26", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:53:21.835Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jvn.jp/en/vu/JVNVU94260088/index.html | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.elecom.co.jp/news/security/20210706-01/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/en/vu/JVNVU94260088/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.elecom.co.jp/news/security/20210706-01/ | Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
elecom | wrc-300febk_firmware | * | |
elecom | wrc-300febk | - | |
elecom | wrc-f300nf_firmware | * | |
elecom | wrc-f300nf | - | |
elecom | wrc-733febk_firmware | * | |
elecom | wrc-733febk | - | |
elecom | wrh-300rd_firmware | * | |
elecom | wrh-300rd | - | |
elecom | wrh-300bk_firmware | * | |
elecom | wrh-300bk | - | |
elecom | wrh-300sv_firmware | * | |
elecom | wrh-300sv | - | |
elecom | wrh-300wh_firmware | * | |
elecom | wrh-300wh | - | |
elecom | wrh-h300wh_firmware | * | |
elecom | wrh-h300wh | - | |
elecom | wrh-h300bk_firmware | * | |
elecom | wrh-h300bk | - | |
elecom | wrh-300bk-s_firmware | * | |
elecom | wrh-300bk-s | - | |
elecom | wrh-300wh-s_firmware | * | |
elecom | wrh-300wh-s | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-300febk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "634C6410-3AC8-4770-8D3F-AF12B39BCEB4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-300febk:-:*:*:*:*:*:*:*", "matchCriteriaId": "8AD07548-B957-4275-BE59-F40940E078A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-f300nf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BE6FA33-6CC9-4AFC-B6EC-8BEE7BE7BAE7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-f300nf:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF251645-9505-49CC-BA4D-1CA454D639D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-733febk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCFD89BC-4736-4BEA-A1E5-42305D9E1B88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-733febk:-:*:*:*:*:*:*:*", "matchCriteriaId": "2152FA45-F61F-4347-B9B3-992C994D1B64", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300rd_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1AA5CB5-25F3-4995-9254-8E0214B2DD4A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300rd:-:*:*:*:*:*:*:*", "matchCriteriaId": "5398598E-4579-44DF-95FB-EBB2871A248E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300bk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C184A52-C8E1-4604-9204-575282410CA1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300bk:-:*:*:*:*:*:*:*", "matchCriteriaId": "89ED96E9-D73D-42E7-A86F-7A73E00D2B86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300sv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6E69313-490A-4263-B01E-81E31C9AC805", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300sv:-:*:*:*:*:*:*:*", "matchCriteriaId": "6D4159F7-1DF3-4827-9784-E338CC3E7D93", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300wh_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7288F3AF-F903-4AD5-8680-EFCD23ACC333", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300wh:-:*:*:*:*:*:*:*", "matchCriteriaId": "E458D9A1-C2AF-4A8F-AC52-8A9D25C303ED", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-h300wh_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1D857DD7-F3D3-4874-A9C5-3F8161381C1E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-h300wh:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8C25CFC-393E-4487-965F-8F922723346F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-h300bk_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1941F445-18F2-42E7-BF96-26B82FDC05BA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-h300bk:-:*:*:*:*:*:*:*", "matchCriteriaId": "99341BF6-FD30-421A-9E9C-32C99B6F75AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300bk-s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C727AFD4-B712-4E7F-9AF6-7F5FC5CBC255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300bk-s:-:*:*:*:*:*:*:*", "matchCriteriaId": "85EB981B-03EA-49B3-99EA-A8389F795C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300wh-s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A866C31-CA0D-4A25-B19B-70F2F8A7A91E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300wh-s:-:*:*:*:*:*:*:*", "matchCriteriaId": "887859FA-3FA7-40E4-BE7B-977C66CF4E37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S, and WRH-300WH-S all versions allows an unauthenticated network-adjacent attacker to execute an arbitrary OS command via unspecified vectors." }, { "lang": "es", "value": "WRC-300FEBK, WRC-F300NF, WRC-733FEBK, WRH-300RD, WRH-300BK, WRH-300SV, WRH-300WH, WRH-H300WH, WRH-H300BK, WRH-300BK-S y WRH-300WH-S, todas las versiones, permiten a un atacante no autenticado adyacente a la red ejecutar un comando arbitrario del sistema operativo por medio de vectores no especificados" } ], "id": "CVE-2021-20739", "lastModified": "2024-11-21T05:47:06.530", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-07T08:15:07.813", "references": [ { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU94260088/index.html" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU94260088/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" } ], "sourceIdentifier": "vultures@jpcert.or.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jvn.jp/en/vu/JVNVU94119876/ | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.elecom.co.jp/news/security/20210706-01/ | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.elecom.co.jp/news/security/20230810-01/ | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.elecom.co.jp/news/security/20231114-01/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/en/vu/JVNVU94119876/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.elecom.co.jp/news/security/20210706-01/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.elecom.co.jp/news/security/20230810-01/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.elecom.co.jp/news/security/20231114-01/ | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
elecom | wrc-2533ghbk2-t_firmware | - | |
elecom | wrc-2533ghbk2-t | - | |
elecom | wrc-2533ghbk-i_firmware | - | |
elecom | wrc-2533ghbk-i | - | |
elecom | wrc-1750ghbk2-i_firmware | - | |
elecom | wrc-1750ghbk2-i | - | |
elecom | wrc-1750ghbk-e_firmware | - | |
elecom | wrc-1750ghbk-e | - | |
elecom | wrc-1750ghbk_firmware | - | |
elecom | wrc-1750ghbk | - | |
elecom | wrc-1167ghbk2_firmware | - | |
elecom | wrc-1167ghbk2 | - | |
elecom | wrc-1167ghbk_firmware | - | |
elecom | wrc-1167ghbk | - | |
elecom | wrc-f1167acf_firmware | - | |
elecom | wrc-f1167acf | - | |
elecom | wrc-733ghbk_firmware | - | |
elecom | wrc-733ghbk | - | |
elecom | wrc-733ghbk-i_firmware | - | |
elecom | wrc-733ghbk-i | - | |
elecom | wrc-733ghbk-c_firmware | - | |
elecom | wrc-733ghbk-c | - | |
elecom | wrc-300ghbk2-i_firmware | - | |
elecom | wrc-300ghbk2-i | - | |
elecom | wrc-300ghbk_firmware | - | |
elecom | wrc-300ghbk | - | |
elecom | wrc-733febk_firmware | - | |
elecom | wrc-733febk | - | |
elecom | wrc-300febk_firmware | - | |
elecom | wrc-300febk | - | |
elecom | wrc-f300nf_firmware | - | |
elecom | wrc-f300nf | - | |
elecom | wrh-300wh-h_firmware | - | |
elecom | wrh-300wh-h | - | |
elecom | wrh-300bk_firmware | - | |
elecom | wrh-300bk | - | |
elecom | wrh-300wh_firmware | - | |
elecom | wrh-300wh | - | |
elecom | wrh-300rd_firmware | - | |
elecom | wrh-300rd | - | |
elecom | wrh-300sv_firmware | - | |
elecom | wrh-300sv | - | |
elecom | wrh-300bk-s_firmware | - | |
elecom | wrh-300bk-s | - | |
elecom | wrh-300wh-s_firmware | - | |
elecom | wrh-300wh-s | - | |
elecom | wrh-300bk2-s_firmware | - | |
elecom | wrh-300bk2-s | - | |
elecom | wrh-300wh2-s_firmware | - | |
elecom | wrh-300wh2-s | - | |
elecom | wrh-h300bk_firmware | - | |
elecom | wrh-h300bk | - | |
elecom | wrh-h300wh_firmware | - | |
elecom | wrh-h300wh | - | |
elecom | wrh-150bk_firmware | - | |
elecom | wrh-150bk | - | |
elecom | wrh-150wh_firmware | - | |
elecom | wrh-150wh | - | |
elecom | lan-w300n\/rs_firmware | - | |
elecom | lan-w300n\/rs | - | |
elecom | lan-w301nr_firmware | - | |
elecom | lan-w301nr | - | |
elecom | lan-w300n\/p_firmware | - | |
elecom | lan-w300n\/p | - | |
elecom | lan-wh300n\/dgp_firmware | - | |
elecom | lan-wh300n\/dgp | - | |
elecom | lan-wh300ndgpe_firmware | - | |
elecom | lan-wh300ndgpe | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-2533ghbk2-t_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "416614AE-FE5E-4807-8AB0-618F46E48C4F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-2533ghbk2-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "991548FF-6EAD-422F-B2CF-316E96FB7F6F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-2533ghbk-i_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "65FF48A0-3059-4969-9C7D-D12B1E164DE6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-2533ghbk-i:-:*:*:*:*:*:*:*", "matchCriteriaId": "DDD11C2A-1EC2-420D-B2AE-FEB67E9866FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-1750ghbk2-i_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "68DEE867-A37C-4199-BE44-222706725533", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-1750ghbk2-i:-:*:*:*:*:*:*:*", "matchCriteriaId": "E1EAF366-E7EB-4864-BB1C-16D828141CFD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-1750ghbk-e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7AE44EDE-A5BD-486D-9225-A44BAAB39132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-1750ghbk-e:-:*:*:*:*:*:*:*", "matchCriteriaId": "DDB8292C-ABDA-4F61-8EF1-D498AE3BF66C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-1750ghbk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D6E65402-982D-4E0D-A257-806118DBE50A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-1750ghbk:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D1F1675-60C1-4150-8306-1592F88D3DAC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-1167ghbk2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D00FC11-2C8D-4B88-BB15-157F9C7DBA88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-1167ghbk2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7DF1D75E-EF09-4BF7-AC5C-F6CDC5B6ED8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-1167ghbk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2F2F7444-D3CE-4C5B-B021-4EA615442478", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-1167ghbk:-:*:*:*:*:*:*:*", "matchCriteriaId": "A69B25FE-0AF4-49CC-9F10-8F98AFF7CCBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-f1167acf_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "60F558FC-55E4-4DF5-B01D-319A03CE0814", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-f1167acf:-:*:*:*:*:*:*:*", "matchCriteriaId": "C244EA13-D45C-4968-A330-3AD80F588537", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-733ghbk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE82FE52-F2A1-4B9D-B618-7B8D82C497A4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-733ghbk:-:*:*:*:*:*:*:*", "matchCriteriaId": "ED2A27DD-B40D-4415-8CCE-063427864910", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-733ghbk-i_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E9761CF-F0A3-4ACF-B7C0-8BF6EB5F8408", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-733ghbk-i:-:*:*:*:*:*:*:*", "matchCriteriaId": "1900274E-7B26-4183-8912-70BCCC306FF8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-733ghbk-c_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB404C76-CCEB-4242-B602-8A4F93C9F3FA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-733ghbk-c:-:*:*:*:*:*:*:*", "matchCriteriaId": "0ED75E24-5232-4CD1-A8D5-96ECCC3C1D17", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-300ghbk2-i_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "06A5AC4E-6AC5-4CF7-ADAC-4DD51ABF1F4D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-300ghbk2-i:-:*:*:*:*:*:*:*", "matchCriteriaId": "8A85134B-286A-472B-B0D2-C4FE7F5B7FC8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-300ghbk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "17D60C3E-D822-4A09-B9EA-8FBA94DEEC0B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-300ghbk:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD708BA-8E44-45C9-90A9-2CDA33CFA291", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-733febk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FE17625-486F-40E4-9067-07139B69281D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-733febk:-:*:*:*:*:*:*:*", "matchCriteriaId": "2152FA45-F61F-4347-B9B3-992C994D1B64", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-300febk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBA18046-201B-4009-BE58-B2457DCF206A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-300febk:-:*:*:*:*:*:*:*", "matchCriteriaId": "8AD07548-B957-4275-BE59-F40940E078A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrc-f300nf_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6278262-98AD-4D51-B368-C8B7C47F4510", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrc-f300nf:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF251645-9505-49CC-BA4D-1CA454D639D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300wh-h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C616FACD-FD5F-4CE3-A196-3447A0D8B5D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300wh-h:-:*:*:*:*:*:*:*", "matchCriteriaId": "079F2DC5-840A-4201-B46C-F9339968D256", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300bk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FF22457-912C-4818-B31E-DCBDF60E6A19", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300bk:-:*:*:*:*:*:*:*", "matchCriteriaId": "89ED96E9-D73D-42E7-A86F-7A73E00D2B86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300wh_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D59399A-BE39-4E30-BF0F-8EBADD179279", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300wh:-:*:*:*:*:*:*:*", "matchCriteriaId": "E458D9A1-C2AF-4A8F-AC52-8A9D25C303ED", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300rd_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "58DFD59C-AAF4-4B14-A6D5-4CC8D436FDC2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300rd:-:*:*:*:*:*:*:*", "matchCriteriaId": "5398598E-4579-44DF-95FB-EBB2871A248E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300sv_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1E84D55-C80A-4813-AA15-2E67E1B849C3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300sv:-:*:*:*:*:*:*:*", "matchCriteriaId": "6D4159F7-1DF3-4827-9784-E338CC3E7D93", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300bk-s_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "221C60DE-F1B0-4284-87DB-EE22B137B16E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300bk-s:-:*:*:*:*:*:*:*", "matchCriteriaId": "85EB981B-03EA-49B3-99EA-A8389F795C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300wh-s_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "814F1554-9070-4439-BDD0-379596B6710C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300wh-s:-:*:*:*:*:*:*:*", "matchCriteriaId": "887859FA-3FA7-40E4-BE7B-977C66CF4E37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300bk2-s_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C8ABEA4-95AB-4B17-BA47-8FC17B62CB6E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300bk2-s:-:*:*:*:*:*:*:*", "matchCriteriaId": "476D444E-3A59-4A46-975C-C33AC3F1BB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-300wh2-s_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E429963F-D7D0-46A0-BD2D-98BD6A9F5348", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-300wh2-s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C383661F-19E5-4976-BAC2-1077B67D12A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-h300bk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "641FC18A-D8A1-49BB-99D3-C4649B420686", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-h300bk:-:*:*:*:*:*:*:*", "matchCriteriaId": "99341BF6-FD30-421A-9E9C-32C99B6F75AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-h300wh_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F58AC396-DE39-4BD2-9E0E-46950312ABD0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-h300wh:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8C25CFC-393E-4487-965F-8F922723346F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-150bk_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B42DDDAA-92A9-4D41-9369-A163D6045B15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-150bk:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D11F66F-CEEA-42AB-B1E1-B569FB08B0F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:wrh-150wh_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "378E5102-178F-4C8D-8C0B-CCCF9769A381", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:wrh-150wh:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E8082CE-18E8-438F-B953-D5EF1A27FE0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:lan-w300n\\/rs_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8AAF4C0E-F270-4062-925E-38C65F7280A4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:lan-w300n\\/rs:-:*:*:*:*:*:*:*", "matchCriteriaId": "0032270C-53E3-4A46-95A8-FDE5DEFDC75C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:lan-w301nr_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE6896F9-6B59-4420-AB70-21B8B84C3B38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:lan-w301nr:-:*:*:*:*:*:*:*", "matchCriteriaId": "1A667CE5-0926-4986-B9F6-0F2C23F70FEF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:lan-w300n\\/p_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0376434A-D083-4F7C-9BB1-A9F58F86D3A3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:lan-w300n\\/p:-:*:*:*:*:*:*:*", "matchCriteriaId": "BAD881BC-A228-4402-8A09-5E862B448A62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:lan-wh300n\\/dgp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F5C8E61-367D-40AE-B37D-F1CED982DAD2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:lan-wh300n\\/dgp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B27DECBE-877C-4888-A4B0-C0A65A590640", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:elecom:lan-wh300ndgpe_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0870306-5179-4477-8C88-EDFC507ED3D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:elecom:lan-wh300ndgpe:-:*:*:*:*:*:*:*", "matchCriteriaId": "72FE6693-2075-4A08-9ACC-4564A36A16BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Inadequate encryption strength vulnerability in multiple routers provided by ELECOM CO.,LTD. and LOGITEC CORPORATION allows a network-adjacent unauthenticated attacker to guess the encryption key used for wireless LAN communication and intercept the communication. As for the affected products/versions, see the information provided by the vendor under [References] section." }, { "lang": "es", "value": "Vulnerabilidad de fuerza de cifrado inadecuada en m\u00faltiples routers proporcionados por ELECOM CO.,LTD. y LOGITEC CORPORATION permite que un atacante no autenticado adyacente a la red adivine la clave de cifrado utilizada para la comunicaci\u00f3n LAN inal\u00e1mbrica e intercepte la comunicaci\u00f3n. En cuanto a los productos/versiones afectados, consulte la informaci\u00f3n proporcionada por el proveedor en la secci\u00f3n [Referencias]." } ], "id": "CVE-2023-43757", "lastModified": "2024-11-21T08:24:43.627", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-16T07:15:08.600", "references": [ { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU94119876/" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://www.elecom.co.jp/news/security/20230810-01/" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://www.elecom.co.jp/news/security/20231114-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU94119876/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.elecom.co.jp/news/security/20210706-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.elecom.co.jp/news/security/20230810-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.elecom.co.jp/news/security/20231114-01/" } ], "sourceIdentifier": "vultures@jpcert.or.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-326" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }