Search criteria
6 vulnerabilities found for x-320m-i_firmware by controlbyweb
FKIE_CVE-2018-18882
Vulnerability from fkie_nvd - Published: 2019-03-21 16:00 - Updated: 2024-11-21 03:56
Severity ?
Summary
A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://www.securityfocus.com/bid/106655 | Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106655 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| controlbyweb | x-320m-i_firmware | * | |
| controlbyweb | x-320m-i | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:controlbyweb:x-320m-i_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9C00D381-A6A0-4D85-9F7A-DBD7312B3901",
"versionEndIncluding": "1.05",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:controlbyweb:x-320m-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E9321E-54F4-4978-9A72-0108CFC27D7F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de Cross-Site Scripting (XSS) persistente en en el m\u00f3dulo de adquisici\u00f3n de datos ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade 1.05 con la revisi\u00f3n de firmware v1.05. Un usuario autenticado puede inyectar scripts arbitrarios mediante setup.html en la interfaz web."
}
],
"id": "CVE-2018-18882",
"lastModified": "2024-11-21T03:56:49.047",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-03-21T16:00:29.810",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-18881
Vulnerability from fkie_nvd - Published: 2019-03-21 16:00 - Updated: 2024-11-21 03:56
Severity ?
Summary
A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://www.securityfocus.com/bid/106655 | Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106655 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| controlbyweb | x-320m-i_firmware | * | |
| controlbyweb | x-320m-i | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:controlbyweb:x-320m-i_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9C00D381-A6A0-4D85-9F7A-DBD7312B3901",
"versionEndIncluding": "1.05",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:controlbyweb:x-320m-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3E9321E-54F4-4978-9A72-0108CFC27D7F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de denegaci\u00f3n de servicio (DoS) en el m\u00f3dulo de adquisici\u00f3n de datos ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade 1.05 con la revisi\u00f3n de firmware v1.05. Un usuario autenticado puede configurar unas opciones de red inv\u00e1lidas, paralizando las comunicaciones TCP al dispositivo. Se necesita realizar un reinicio f\u00edsico a f\u00e1brica para restaurar el dispositivo a un estado funcional."
}
],
"id": "CVE-2018-18881",
"lastModified": "2024-11-21T03:56:48.890",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-03-21T16:00:29.750",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2018-18882 (GCVE-0-2018-18882)
Vulnerability from cvelistv5 – Published: 2019-03-17 21:10 – Updated: 2024-08-05 11:23
VLAI?
Summary
A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:23:08.527Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-17T21:10:38",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-18882",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106655",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106655"
},
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-18882",
"datePublished": "2019-03-17T21:10:38",
"dateReserved": "2018-10-31T00:00:00",
"dateUpdated": "2024-08-05T11:23:08.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-18881 (GCVE-0-2018-18881)
Vulnerability from cvelistv5 – Published: 2019-03-17 21:09 – Updated: 2024-08-05 11:23
VLAI?
Summary
A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:23:08.477Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-17T21:09:32",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-18881",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106655",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106655"
},
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-18881",
"datePublished": "2019-03-17T21:09:32",
"dateReserved": "2018-10-31T00:00:00",
"dateUpdated": "2024-08-05T11:23:08.477Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-18882 (GCVE-0-2018-18882)
Vulnerability from nvd – Published: 2019-03-17 21:10 – Updated: 2024-08-05 11:23
VLAI?
Summary
A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:23:08.527Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-17T21:10:38",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-18882",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106655",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106655"
},
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-18882",
"datePublished": "2019-03-17T21:10:38",
"dateReserved": "2018-10-31T00:00:00",
"dateUpdated": "2024-08-05T11:23:08.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-18881 (GCVE-0-2018-18881)
Vulnerability from nvd – Published: 2019-03-17 21:09 – Updated: 2024-08-05 11:23
VLAI?
Summary
A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:23:08.477Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-17T21:09:32",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "106655",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106655"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-18881",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106655",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106655"
},
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-18881",
"datePublished": "2019-03-17T21:09:32",
"dateReserved": "2018-10-31T00:00:00",
"dateUpdated": "2024-08-05T11:23:08.477Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}