Search criteria

12 vulnerabilities found for xp_9000_command_view by hp

FKIE_CVE-2018-7091

Vulnerability from fkie_nvd - Published: 2018-08-06 20:29 - Updated: 2024-11-21 04:11
Summary
HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Impacted products
Vendor Product Version
hp xp_9000_command_view *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:*:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "A89FE91C-7141-4279-A8F4-D7BB08E327FD",
              "versionEndExcluding": "8.60-00",
              "versionStartIncluding": "7.0.0-00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
    },
    {
      "lang": "es",
      "value": "HPE XP P9000 Command View Advanced Edition (CVAE) tiene una vulnerabilidad de redirecci\u00f3n abierta de URL, desde la versi\u00f3n 7.0.0-00 hasta antes de la 8.60-00 de DevMgr, TSMgr y RepMgr."
    }
  ],
  "id": "CVE-2018-7091",
  "lastModified": "2024-11-21T04:11:37.753",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-08-06T20:29:02.257",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-601"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2018-7090

Vulnerability from fkie_nvd - Published: 2018-08-06 20:29 - Updated: 2024-11-21 04:11
Summary
HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Impacted products
Vendor Product Version
hp xp_9000_command_view *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:*:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "A89FE91C-7141-4279-A8F4-D7BB08E327FD",
              "versionEndExcluding": "8.60-00",
              "versionStartIncluding": "7.0.0-00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
    },
    {
      "lang": "es",
      "value": "HPE XP P9000 Command View Advanced Edition (CVAE) tiene una vulnerabilidad de Cross-Site Scripting (XSS) remoto y local, desde la versi\u00f3n 7.0.0-00 hasta antes de la 8.60-00 de DevMgr, TSMgr y RepMgr."
    }
  ],
  "id": "CVE-2018-7090",
  "lastModified": "2024-11-21T04:11:37.657",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-08-06T20:29:02.210",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2016-4378

Vulnerability from fkie_nvd - Published: 2016-08-26 19:59 - Updated: 2025-04-12 10:46
Summary
The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors.
Impacted products
Vendor Product Version
hp xp_9000_command_view *
hp xp7_command_view *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:*:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "8D76CD38-8A93-4753-A5D4-292EB9EBAEC1",
              "versionEndIncluding": "8.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp7_command_view:*:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "C1CDF5F5-AF4F-4C5C-B0A1-A57A49700C38",
              "versionEndIncluding": "8.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Los componentes (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor y (5) Hitachi Automation Director (HAD) en HPE XP P9000 Command View Advanced Edition Software en versiones anteriores a 8.4.1-00 y XP7 Command View Advanced Edition Suite en versiones anteriores a 8.4.1-00 permiten a atacantes remotos obtener informaci\u00f3n sensible a trav\u00e9s de vectores no especificados."
    }
  ],
  "id": "CVE-2016-4378",
  "lastModified": "2025-04-12T10:46:40.837",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-08-26T19:59:07.883",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/92649"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securitytracker.com/id/1036686"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/92649"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securitytracker.com/id/1036686"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-4814

Vulnerability from fkie_nvd - Published: 2013-09-23 10:18 - Updated: 2025-04-11 00:51
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.0.0:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "C31DBA09-2BC0-4CB2-970C-76AD833717CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.1.0:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "FF45403C-881F-4715-B449-2B6BE929F623",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.1.1:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "C39FBBF4-901F-4AFF-BC11-53D2B706229E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.2.0:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "EBB42D1A-0324-43B8-8B1A-ED2B3B2E94CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.3.0:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "BF6790E0-BD11-4564-8660-22A0C8F31080",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.3.1:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "49DD3DB9-BF46-4D95-BAC9-49CE4DF57C68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.4.0:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "A3390A42-8DEC-495B-BCB4-79A54BC1B21D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.4.1:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "0F32674B-8095-44C8-946D-585226439F41",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:hp:xp_9000_command_view:7.5.0:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "2AF647F8-40BA-42AE-AC3E-F2E1DF12A2A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad XSS en HP XP P9000 Command View Advanced Edition Suite Software v7.x anterior a v7.5.0-02 permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarias a trav\u00e9s de vectores no \nespecificados."
    }
  ],
  "id": "CVE-2013-4814",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2013-09-23T10:18:58.877",
  "references": [
    {
      "source": "hp-security-alert@hp.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
    }
  ],
  "sourceIdentifier": "hp-security-alert@hp.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2018-7091 (GCVE-0-2018-7091)

Vulnerability from cvelistv5 – Published: 2018-08-06 20:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Severity ?
No CVSS data available.
CWE
  • open redirect
Assigner
hpe
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:17:17.467Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE XP P9000 Command View Advanced Edition Software (CVAE)",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "versions 7.0.0-00 to earlier than 8.60-00"
            }
          ]
        }
      ],
      "datePublic": "2018-08-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "open redirect",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-06T19:57:01",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2018-7091",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE XP P9000 Command View Advanced Edition Software (CVAE)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions 7.0.0-00 to earlier than 8.60-00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "open redirect"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2018-7091",
    "datePublished": "2018-08-06T20:00:00",
    "dateReserved": "2018-02-15T00:00:00",
    "dateUpdated": "2024-08-05T06:17:17.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7090 (GCVE-0-2018-7090)

Vulnerability from cvelistv5 – Published: 2018-08-06 20:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Severity ?
No CVSS data available.
CWE
  • cross site scripting (XSS)
Assigner
hpe
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:17:17.355Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE XP P9000 Command View Advanced Edition Software (CVAE) versions 7.0.0-00 to earlier than 8.60-00",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "versions 7.0.0-00 to earlier than 8.60-00"
            }
          ]
        }
      ],
      "datePublic": "2018-08-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cross site scripting (XSS)",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-06T19:57:01",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2018-7090",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE XP P9000 Command View Advanced Edition Software (CVAE) versions 7.0.0-00 to earlier than 8.60-00",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions 7.0.0-00 to earlier than 8.60-00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cross site scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2018-7090",
    "datePublished": "2018-08-06T20:00:00",
    "dateReserved": "2018-02-15T00:00:00",
    "dateUpdated": "2024-08-05T06:17:17.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-4378 (GCVE-0-2016-4378)

Vulnerability from cvelistv5 – Published: 2016-08-26 19:00 – Updated: 2024-08-06 00:25
VLAI?
Summary
The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:25:14.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
          },
          {
            "name": "1036686",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1036686"
          },
          {
            "name": "92649",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92649"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-08-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-11-25T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
        },
        {
          "name": "1036686",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1036686"
        },
        {
          "name": "92649",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92649"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2016-4378",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355",
              "refsource": "CONFIRM",
              "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
            },
            {
              "name": "1036686",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1036686"
            },
            {
              "name": "92649",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92649"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-4378",
    "datePublished": "2016-08-26T19:00:00",
    "dateReserved": "2016-04-29T00:00:00",
    "dateUpdated": "2024-08-06T00:25:14.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4814 (GCVE-0-2013-4814)

Vulnerability from cvelistv5 – Published: 2013-09-23 10:00 – Updated: 2024-09-16 20:53
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
hp
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.269Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "HPSBST02919",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
          },
          {
            "name": "SSRT101302",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-09-23T10:00:00Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "name": "HPSBST02919",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
        },
        {
          "name": "SSRT101302",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "hp-security-alert@hp.com",
          "ID": "CVE-2013-4814",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "HPSBST02919",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
            },
            {
              "name": "SSRT101302",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2013-4814",
    "datePublished": "2013-09-23T10:00:00Z",
    "dateReserved": "2013-07-12T00:00:00Z",
    "dateUpdated": "2024-09-16T20:53:23.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7091 (GCVE-0-2018-7091)

Vulnerability from nvd – Published: 2018-08-06 20:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Severity ?
No CVSS data available.
CWE
  • open redirect
Assigner
hpe
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:17:17.467Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE XP P9000 Command View Advanced Edition Software (CVAE)",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "versions 7.0.0-00 to earlier than 8.60-00"
            }
          ]
        }
      ],
      "datePublic": "2018-08-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "open redirect",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-06T19:57:01",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2018-7091",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE XP P9000 Command View Advanced Edition Software (CVAE)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions 7.0.0-00 to earlier than 8.60-00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "open redirect"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2018-7091",
    "datePublished": "2018-08-06T20:00:00",
    "dateReserved": "2018-02-15T00:00:00",
    "dateUpdated": "2024-08-05T06:17:17.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7090 (GCVE-0-2018-7090)

Vulnerability from nvd – Published: 2018-08-06 20:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Severity ?
No CVSS data available.
CWE
  • cross site scripting (XSS)
Assigner
hpe
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:17:17.355Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE XP P9000 Command View Advanced Edition Software (CVAE) versions 7.0.0-00 to earlier than 8.60-00",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "versions 7.0.0-00 to earlier than 8.60-00"
            }
          ]
        }
      ],
      "datePublic": "2018-08-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cross site scripting (XSS)",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-06T19:57:01",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2018-7090",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE XP P9000 Command View Advanced Edition Software (CVAE) versions 7.0.0-00 to earlier than 8.60-00",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions 7.0.0-00 to earlier than 8.60-00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "HPE XP P9000 Command View Advanced Edition Software (CVAE) has local and remote cross site scripting vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cross site scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03859en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2018-7090",
    "datePublished": "2018-08-06T20:00:00",
    "dateReserved": "2018-02-15T00:00:00",
    "dateUpdated": "2024-08-05T06:17:17.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-4378 (GCVE-0-2016-4378)

Vulnerability from nvd – Published: 2016-08-26 19:00 – Updated: 2024-08-06 00:25
VLAI?
Summary
The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:25:14.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
          },
          {
            "name": "1036686",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1036686"
          },
          {
            "name": "92649",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92649"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-08-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-11-25T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
        },
        {
          "name": "1036686",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1036686"
        },
        {
          "name": "92649",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92649"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2016-4378",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The (1) Device Manager, (2) Tiered Storage Manager, (3) Replication Manager, (4) Replication Monitor, and (5) Hitachi Automation Director (HAD) components in HPE XP P9000 Command View Advanced Edition Software before 8.4.1-00 and XP7 Command View Advanced Edition Suite before 8.4.1-00 allow remote attackers to obtain sensitive information via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355",
              "refsource": "CONFIRM",
              "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05241355"
            },
            {
              "name": "1036686",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1036686"
            },
            {
              "name": "92649",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92649"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-4378",
    "datePublished": "2016-08-26T19:00:00",
    "dateReserved": "2016-04-29T00:00:00",
    "dateUpdated": "2024-08-06T00:25:14.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4814 (GCVE-0-2013-4814)

Vulnerability from nvd – Published: 2013-09-23 10:00 – Updated: 2024-09-16 20:53
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
hp
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.269Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "HPSBST02919",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
          },
          {
            "name": "SSRT101302",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-09-23T10:00:00Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "name": "HPSBST02919",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
        },
        {
          "name": "SSRT101302",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "hp-security-alert@hp.com",
          "ID": "CVE-2013-4814",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting (XSS) vulnerability in HP XP P9000 Command View Advanced Edition Suite Software 7.x before 7.5.0-02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "HPSBST02919",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
            },
            {
              "name": "SSRT101302",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03898171"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2013-4814",
    "datePublished": "2013-09-23T10:00:00Z",
    "dateReserved": "2013-07-12T00:00:00Z",
    "dateUpdated": "2024-09-16T20:53:23.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}