    2 vulnerabilities found for zoom_latitude_programming_system_model_3120_firmware by bostonscientific

    CVE-2021-38398 (GCVE-0-2021-38398)

    Vulnerability from cvelistv5 – Published: 2021-10-04 17:35 – Updated: 2024-09-16 17:58
    VLAI
    Title
    Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude
    Summary
    The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities.
    CWE
    Assigner
    References
    Impacted products
    Date Public
    2021-09-30 00:00
    Credits
    Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH Münster University of Applied Sciences, Christian Dresen - FH Münster University of Applied Sciences, and Markus Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices and reported them to Boston Scientific.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:37:16.493Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ZOOM LATITUDE",
              "vendor": "Boston Scientific",
              "versions": [
                {
                  "status": "affected",
                  "version": "Model 3120"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster  University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus  Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices  and reported them to Boston Scientific."
            }
          ],
          "datePublic": "2021-09-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1329",
                  "description": "CWE-1329",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-04T17:35:06.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"
            }
          ],
          "source": {
            "advisory": "ICSMA-21-273-01",
            "defect": [
              "CWE-1329"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude",
          "workarounds": [
            {
              "lang": "en",
              "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security,  the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-09-30T21:02:00.000Z",
              "ID": "CVE-2021-38398",
              "STATE": "PUBLIC",
              "TITLE": "Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ZOOM LATITUDE",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Model 3120"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Boston Scientific"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster  University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus  Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices  and reported them to Boston Scientific."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-1329"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"
                }
              ]
            },
            "source": {
              "advisory": "ICSMA-21-273-01",
              "defect": [
                "CWE-1329"
              ],
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security,  the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-38398",
        "datePublished": "2021-10-04T17:35:06.578Z",
        "dateReserved": "2021-08-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:58:22.688Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-38398 (GCVE-0-2021-38398)

    Vulnerability from nvd – Published: 2021-10-04 17:35 – Updated: 2024-09-16 17:58
    VLAI
    Title
    Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude
    Summary
    The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities.
    CWE
    Assigner
    References
    Impacted products
    Date Public
    2021-09-30 00:00
    Credits
    Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH Münster University of Applied Sciences, Christian Dresen - FH Münster University of Applied Sciences, and Markus Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices and reported them to Boston Scientific.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:37:16.493Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ZOOM LATITUDE",
              "vendor": "Boston Scientific",
              "versions": [
                {
                  "status": "affected",
                  "version": "Model 3120"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster  University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus  Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices  and reported them to Boston Scientific."
            }
          ],
          "datePublic": "2021-09-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1329",
                  "description": "CWE-1329",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-04T17:35:06.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"
            }
          ],
          "source": {
            "advisory": "ICSMA-21-273-01",
            "defect": [
              "CWE-1329"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude",
          "workarounds": [
            {
              "lang": "en",
              "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security,  the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-09-30T21:02:00.000Z",
              "ID": "CVE-2021-38398",
              "STATE": "PUBLIC",
              "TITLE": "Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ZOOM LATITUDE",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Model 3120"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Boston Scientific"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster  University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus  Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices  and reported them to Boston Scientific."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-1329"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"
                }
              ]
            },
            "source": {
              "advisory": "ICSMA-21-273-01",
              "defect": [
                "CWE-1329"
              ],
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security,  the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-38398",
        "datePublished": "2021-10-04T17:35:06.578Z",
        "dateReserved": "2021-08-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:58:22.688Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }