Common Weakness Enumeration
CWE-121
AllowedStack-based Buffer Overflow
Abstraction: Variant · Status: Draft
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
5667 vulnerabilities reference this CWE, most recent first.
CVE-2024-2558 (GCVE-0-2024-2558)
Vulnerability from cvelistv5 – Published: 2024-03-17 09:00 – Updated: 2024-08-02 17:32
VLAI
EPSS
VEX
Title
Tenda AC18 execCommand formexeCommand stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-03-18 15:37 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257057 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257057 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:47.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257057 | Tenda AC18 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257057"
},
{
"name": "VDB-257057 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257057"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formexeCommand.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2558",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-18T15:37:52.626613Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-02T17:32:11.576Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formexeCommand der Datei /goform/execCommand. Durch das Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-17T09:00:07.516Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257057 | Tenda AC18 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257057"
},
{
"name": "VDB-257057 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257057"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-16T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-16T07:59:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2558",
"datePublished": "2024-03-17T09:00:07.516Z",
"dateReserved": "2024-03-16T06:54:24.270Z",
"dateUpdated": "2024-08-02T17:32:11.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2547 (GCVE-0-2024-2547)
Vulnerability from cvelistv5 – Published: 2024-03-17 03:31 – Updated: 2024-08-21 15:16
VLAI
EPSS
VEX
Title
Tenda AC18 R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-21 15:14 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257000 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257000 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.212Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257000 | Tenda AC18 R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257000"
},
{
"name": "VDB-257000 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257000"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/R7WebsSecurityHandler.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2547",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T15:14:45.903222Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T15:16:52.674Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 gefunden. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion R7WebsSecurityHandler. Durch das Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-17T03:31:03.829Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257000 | Tenda AC18 R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257000"
},
{
"name": "VDB-257000 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257000"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/R7WebsSecurityHandler.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T21:09:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 R7WebsSecurityHandler stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2547",
"datePublished": "2024-03-17T03:31:03.829Z",
"dateReserved": "2024-03-15T20:04:28.272Z",
"dateUpdated": "2024-08-21T15:16:52.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2546 (GCVE-0-2024-2546)
Vulnerability from cvelistv5 – Published: 2024-03-17 01:31 – Updated: 2024-08-01 19:18
VLAI
EPSS
VEX
Title
Tenda AC18 fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-16 21:06 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256999 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256999 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.13.07.09
|
|
| tenda | ac18_firmware |
Affected:
15.13.07.09
cpe:2.3:o:tenda:ac18_firmware:15.13.07.09:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.13.07.09:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2546",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T21:06:00.663025Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T21:06:58.371Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:47.953Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256999 | Tenda AC18 fromSetWirelessRepeat stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256999"
},
{
"name": "VDB-256999 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256999"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/A18/fromSetWirelessRepeat_a.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC18 15.13.07.09 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromSetWirelessRepeat. Mittels Manipulieren des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-17T01:31:04.350Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256999 | Tenda AC18 fromSetWirelessRepeat stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256999"
},
{
"name": "VDB-256999 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256999"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/A18/fromSetWirelessRepeat_a.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-16T08:00:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 fromSetWirelessRepeat stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2546",
"datePublished": "2024-03-17T01:31:04.350Z",
"dateReserved": "2024-03-15T20:04:21.580Z",
"dateUpdated": "2024-08-01T19:18:47.953Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2490 (GCVE-0-2024-2490)
Vulnerability from cvelistv5 – Published: 2024-03-15 09:31 – Updated: 2024-08-01 19:18
VLAI
EPSS
VEX
Title
Tenda AC18 openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-16 21:05 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256897 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256897 | signaturepermissions-required |
| https://github.com/Emilytutu/IoT-vulnerable/blob/… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2490",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T21:05:16.681190Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T21:05:39.904Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:46.467Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256897 | Tenda AC18 openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256897"
},
{
"name": "VDB-256897 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256897"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/Emilytutu/IoT-vulnerable/blob/main/Tenda/AC18/setSchedWifi_end.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC18 15.03.05.05 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion setSchedWifi der Datei /goform/openSchedWifi. Durch die Manipulation des Arguments schedStartTime/schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-15T09:31:04.121Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256897 | Tenda AC18 openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256897"
},
{
"name": "VDB-256897 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256897"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Emilytutu/IoT-vulnerable/blob/main/Tenda/AC18/setSchedWifi_end.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T01:48:09.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 openSchedWifi setSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2490",
"datePublished": "2024-03-15T09:31:04.121Z",
"dateReserved": "2024-03-15T00:43:05.939Z",
"dateUpdated": "2024-08-01T19:18:46.467Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2489 (GCVE-0-2024-2489)
Vulnerability from cvelistv5 – Published: 2024-03-15 09:00 – Updated: 2025-04-10 20:28
VLAI
EPSS
VEX
Title
Tenda AC18 SetNetControlList formSetQosBand stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-03-18 13:50 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256896 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256896 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2489",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-18T13:50:37.546517Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-10T20:28:47.497Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.495Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256896 | Tenda AC18 SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256896"
},
{
"name": "VDB-256896 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256896"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetQosBand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC18 15.03.05.05 entdeckt. Hiervon betroffen ist die Funktion formSetQosBand der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-15T09:00:10.441Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256896 | Tenda AC18 SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256896"
},
{
"name": "VDB-256896 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256896"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetQosBand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T01:48:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 SetNetControlList formSetQosBand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2489",
"datePublished": "2024-03-15T09:00:10.441Z",
"dateReserved": "2024-03-15T00:43:00.217Z",
"dateUpdated": "2025-04-10T20:28:47.497Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2488 (GCVE-0-2024-2488)
Vulnerability from cvelistv5 – Published: 2024-03-15 09:00 – Updated: 2024-08-21 15:21
VLAI
EPSS
VEX
Title
Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-21 15:19 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256895 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256895 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.563Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256895 | Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256895"
},
{
"name": "VDB-256895 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256895"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetPPTPServer.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2488",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T15:19:24.932211Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T15:21:16.841Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Dank Manipulation des Arguments startIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-15T09:00:08.823Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256895 | Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256895"
},
{
"name": "VDB-256895 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256895"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetPPTPServer.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T01:47:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2488",
"datePublished": "2024-03-15T09:00:08.823Z",
"dateReserved": "2024-03-15T00:42:54.142Z",
"dateUpdated": "2024-08-21T15:21:16.841Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2487 (GCVE-0-2024-2487)
Vulnerability from cvelistv5 – Published: 2024-03-15 08:31 – Updated: 2024-08-08 20:48
VLAI
EPSS
VEX
Title
Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-08 20:48 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256894 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256894 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.605Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256894 | Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256894"
},
{
"name": "VDB-256894 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256894"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetDeviceName_devName.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2487",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-08T20:48:11.123358Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-08T20:48:48.983Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC18 15.03.05.05 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Dank der Manipulation des Arguments devName/mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-15T08:31:04.506Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256894 | Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256894"
},
{
"name": "VDB-256894 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256894"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetDeviceName_devName.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T01:47:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2487",
"datePublished": "2024-03-15T08:31:04.506Z",
"dateReserved": "2024-03-15T00:42:38.900Z",
"dateUpdated": "2024-08-08T20:48:48.983Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2486 (GCVE-0-2024-2486)
Vulnerability from cvelistv5 – Published: 2024-03-15 08:00 – Updated: 2024-08-01 19:11
VLAI
EPSS
VEX
Title
Tenda AC18 QuickIndex formQuickIndex stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-03-15 19:13 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256893 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256893 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2486",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-15T19:13:56.363699Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:22:19.417Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.562Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256893"
},
{
"name": "VDB-256893 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256893"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formQuickIndex der Datei /goform/QuickIndex. Durch Beeinflussen des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-15T08:00:06.524Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256893 | Tenda AC18 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256893"
},
{
"name": "VDB-256893 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256893"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formQuickIndex.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T01:47:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 QuickIndex formQuickIndex stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2486",
"datePublished": "2024-03-15T08:00:06.524Z",
"dateReserved": "2024-03-15T00:42:32.950Z",
"dateUpdated": "2024-08-01T19:11:53.562Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2485 (GCVE-0-2024-2485)
Vulnerability from cvelistv5 – Published: 2024-03-15 07:00 – Updated: 2025-02-13 17:40
VLAI
EPSS
VEX
Title
Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-02 19:22 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256892 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256892 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.709Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256892 | Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256892"
},
{
"name": "VDB-256892 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256892"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2485",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-02T19:22:53.972031Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-02T19:23:30.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 gefunden. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSpeedWan der Datei /goform/SetSpeedWan. Durch das Beeinflussen des Arguments speed_dir mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T19:35:31.590Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256892 | Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256892"
},
{
"name": "VDB-256892 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256892"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md"
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T01:47:29.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2485",
"datePublished": "2024-03-15T07:00:08.196Z",
"dateReserved": "2024-03-15T00:42:22.429Z",
"dateUpdated": "2025-02-13T17:40:31.194Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-1941 (GCVE-0-2024-1941)
Vulnerability from cvelistv5 – Published: 2024-03-01 00:17 – Updated: 2024-08-22 18:09
VLAI
EPSS
VEX
Title
Delta Electronics CNCSoft-B Stack-based Buffer Overflow
Summary
Delta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-03-01 15:39 UTC
CWE
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Delta Electronics | CNCSoft-B |
Affected:
0 , ≤ 1.0.0.4
(custom)
|
|
| delta_electronics | cncsoft-b |
Affected:
0 , ≤ 1.0.0.4
(custom)
cpe:2.3:a:delta_electronics:cncsoft-b:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:56:22.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-060-01"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-b:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-b",
"vendor": "delta_electronics",
"versions": [
{
"lessThanOrEqual": "1.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1941",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-01T15:39:09.478859Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T18:09:58.459Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-B ",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "1.0.0.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Natnael Samson (@NattiSamson) working with Trend Micro Zero Day Initiative reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.\u003c/span\u003e\n\n"
}
],
"value": "\nDelta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-01T00:17:22.486Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-060-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-B V 1.0.0.4\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;with Issue Date 2024-01-23 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nDelta recommends users update to CNCSoft-B V 1.0.0.4 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0with Issue Date 2024-01-23 or later.\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Delta Electronics CNCSoft-B Stack-based Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-1941",
"datePublished": "2024-03-01T00:17:22.486Z",
"dateReserved": "2024-02-27T18:08:58.530Z",
"dateUpdated": "2024-08-22T18:09:58.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-10
Operation
Build and Compilation
Strategy: Environment Hardening
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design
Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Implementation
Implement and perform bounds checking on input.
Mitigation
Implementation
Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation MIT-11
Operation
Build and Compilation
Strategy: Environment Hardening
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.