    CVE-2026-82695 (GCVE-0-2026-82695)

    Vulnerability from nvd – Published: 2026-08-31 12:45 – Updated: 2026-08-31 14:29
    VLAI
    Title
    Tenda AC18 Telnet telnet missing authentication
    Summary
    A security flaw has been discovered in Tenda AC18 15.03.05.19. Impacted is an unknown function of the file /goform/telnet of the component Telnet Handler. The manipulation results in missing authentication. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-31 14:27 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC18 Affected: 15.03.05.19
        cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82695",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-31T14:27:33.061359Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-31T14:29:57.559Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Telnet Handler"
              ],
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ST4R0003 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda AC18 15.03.05.19. Impacted is an unknown function of the file /goform/telnet of the component Telnet Handler. The manipulation results in missing authentication. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-31T12:45:09.596Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397183 | Tenda AC18 Telnet telnet missing authentication",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/397183"
            },
            {
              "name": "VDB-397183 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397183/cti"
            },
            {
              "name": "CVE-2026-82695 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82695"
            },
            {
              "name": "Submit #894242 | Tenda AC18 ac18_kf_V15.03.05.19 Missing Authentication for Critical Function",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/894242"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/TENDA-AC18-TELNET-DEFAULT-UNAUTH-001-vulndb.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-30T19:49:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC18 Telnet telnet missing authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82695",
        "datePublished": "2026-08-31T12:45:09.596Z",
        "dateReserved": "2026-08-30T17:44:12.858Z",
        "dateUpdated": "2026-08-31T14:29:57.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82694 (GCVE-0-2026-82694)

    Vulnerability from nvd – Published: 2026-08-31 12:30 – Updated: 2026-08-31 17:44
    VLAI
    Title
    Tenda AC1206 Web UI ate R7WebsSecurityHandler missing authentication
    Summary
    A vulnerability was identified in Tenda AC1206 15.03.06.23. This issue affects the function R7WebsSecurityHandler of the file /goform/ate of the component Web UI. The manipulation leads to missing authentication. The attack can be initiated remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-31 17:44 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC1206 Affected: 15.03.06.23
        cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82694",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-31T17:44:24.421345Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-31T17:44:30.348Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/894241"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web UI"
              ],
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ST4R0003 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC1206 15.03.06.23. This issue affects the function R7WebsSecurityHandler of the file /goform/ate of the component Web UI. The manipulation leads to missing authentication. The attack can be initiated remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-31T12:30:10.652Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397182 | Tenda AC1206 Web UI ate R7WebsSecurityHandler missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/397182"
            },
            {
              "name": "VDB-397182 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397182/cti"
            },
            {
              "name": "CVE-2026-82694 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82694"
            },
            {
              "name": "Submit #894241 | Tenda AC1206 V1.0 RTL / F1203-class web UI V15.03.06.23 Missing Authentication for Critical Function\u0026Exposed Dangerous M",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/894241"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/TENDA-AC1206-ATE-DEFAULT-UNAUTH-002-vulndb.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-30T19:47:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC1206 Web UI ate R7WebsSecurityHandler missing authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82694",
        "datePublished": "2026-08-31T12:30:10.652Z",
        "dateReserved": "2026-08-30T17:42:07.633Z",
        "dateUpdated": "2026-08-31T17:44:30.348Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82693 (GCVE-0-2026-82693)

    Vulnerability from nvd – Published: 2026-08-31 12:15 – Updated: 2026-08-31 22:03
    VLAI
    Title
    Tenda AC1206 Web UI telnet TendaTelnet missing authentication
    Summary
    A vulnerability was determined in Tenda AC1206 15.03.06.23. This vulnerability affects the function TendaTelnet of the file /goform/telnet of the component Web UI. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-31 21:56 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC1206 Affected: 15.03.06.23
        cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82693",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-31T21:56:58.989833Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-31T22:03:13.167Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web UI"
              ],
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ST4R0003 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC1206 15.03.06.23. This vulnerability affects the function TendaTelnet of the file /goform/telnet of the component Web UI. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-31T12:15:12.193Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397181 | Tenda AC1206 Web UI telnet TendaTelnet missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/397181"
            },
            {
              "name": "VDB-397181 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397181/cti"
            },
            {
              "name": "CVE-2026-82693 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82693"
            },
            {
              "name": "Submit #894235 | Tenda AC1206 V1.0 RTL / F1203-class web UI V15.03.06.23 Missing Authentication for Critical Function\u0026Missing Authorizati",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/894235"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/TENDA-AC1206-TELNET-DEFAULT-UNAUTH-001-vulndb.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-30T19:47:14.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC1206 Web UI telnet TendaTelnet missing authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82693",
        "datePublished": "2026-08-31T12:15:12.193Z",
        "dateReserved": "2026-08-30T17:42:02.868Z",
        "dateUpdated": "2026-08-31T22:03:13.167Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82542 (GCVE-0-2026-82542)

    Vulnerability from nvd – Published: 2026-08-30 12:30 – Updated: 2026-09-01 14:02
    VLAI
    Title
    Tenda HG10 Boa Web Server formIPv6Routing buffer overflow
    Summary
    A weakness has been identified in Tenda HG10 300001138. Affected by this issue is the function formIPv6Routing of the file /boaform/admin/formIPv6Routing of the component Boa Web Server. This manipulation of the argument destNet causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-01 14:01 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82542",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-01T14:01:41.330939Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-01T14:02:01.116Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda HG10 300001138. Affected by this issue is the function formIPv6Routing of the file /boaform/admin/formIPv6Routing of the component Boa Web Server. This manipulation of the argument destNet causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-30T12:30:09.679Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397058 | Tenda HG10 Boa Web Server formIPv6Routing buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/397058"
            },
            {
              "name": "VDB-397058 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397058/cti"
            },
            {
              "name": "CVE-2026-82542 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82542"
            },
            {
              "name": "Submit #888876 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/888876"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formIPv6Route-destNt.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-29T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-29T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-29T19:49:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Web Server formIPv6Routing buffer overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82542",
        "datePublished": "2026-08-30T12:30:09.679Z",
        "dateReserved": "2026-08-29T17:43:55.683Z",
        "dateUpdated": "2026-09-01T14:02:01.116Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-78141 (GCVE-0-2026-78141)

    Vulnerability from nvd – Published: 2026-08-23 21:45 – Updated: 2026-08-27 14:38
    VLAI Shadowserver Previdian
    Title
    Tenda CH22 exeCommand formexeCommand command injection
    Summary
    A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function formexeCommand of the file /goform/exeCommand. The manipulation of the argument cmdinput leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-27 13:28 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda CH22 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-78141",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-27T13:28:03.286475Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-27T14:38:00.837Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CH22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function formexeCommand of the file /goform/exeCommand. The manipulation of the argument cmdinput leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-23T21:45:09.069Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-394524 | Tenda CH22 exeCommand formexeCommand command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/394524"
            },
            {
              "name": "VDB-394524 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/394524/cti"
            },
            {
              "name": "CVE-2026-78141 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-78141"
            },
            {
              "name": "Submit #882284 | Tenda CH22 V1.0.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/882284"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-CH22-formexeCommand-396df0aa11858036b0cdf7a7562d4a67"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-23T08:02:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CH22 exeCommand formexeCommand command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-78141",
        "datePublished": "2026-08-23T21:45:09.069Z",
        "dateReserved": "2026-08-23T05:57:32.107Z",
        "dateUpdated": "2026-08-27T14:38:00.837Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-78063 (GCVE-0-2026-78063)

    Vulnerability from nvd – Published: 2026-08-23 04:30 – Updated: 2026-08-24 15:13
    VLAI
    Title
    Tenda CH22 editFileName formeditFileName command injection
    Summary
    A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formeditFileName of the file /goform/editFileName. The manipulation of the argument editNameMit results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-24 15:13 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda CH22 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-78063",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-24T15:13:41.098101Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-24T15:13:50.632Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CH22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formeditFileName of the file /goform/editFileName. The manipulation of the argument editNameMit results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-23T04:30:10.230Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-394303 | Tenda CH22 editFileName formeditFileName command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/394303"
            },
            {
              "name": "VDB-394303 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/394303/cti"
            },
            {
              "name": "CVE-2026-78063 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-78063"
            },
            {
              "name": "Submit #881838 | Tenda CH22 V1.0.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/881838"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-CH22-formeditFileName-396df0aa1185804c9dcff01778515d32"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-22T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-22T13:08:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CH22 editFileName formeditFileName command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-78063",
        "datePublished": "2026-08-23T04:30:10.230Z",
        "dateReserved": "2026-08-22T11:03:32.176Z",
        "dateUpdated": "2026-08-24T15:13:50.632Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77031 (GCVE-0-2026-77031)

    Vulnerability from nvd – Published: 2026-08-20 17:15 – Updated: 2026-08-20 18:28
    VLAI
    Title
    Tenda CH22 formcreateFileName command injection
    Summary
    A vulnerability has been found in Tenda CH22 1.0.0.1. The affected element is the function formcreateFileName of the file /goform/formcreateFileName. The manipulation of the argument fileNameMit leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-20 18:28 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda CH22 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-77031",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-20T18:28:41.348933Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-20T18:28:50.477Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CH22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn0121 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda CH22 1.0.0.1. The affected element is the function formcreateFileName of the file /goform/formcreateFileName. The manipulation of the argument fileNameMit leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-20T17:15:09.552Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-393642 | Tenda CH22 formcreateFileName command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/393642"
            },
            {
              "name": "VDB-393642 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/393642/cti"
            },
            {
              "name": "CVE-2026-77031 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-77031"
            },
            {
              "name": "Submit #880667 | Tenda CH22 V1.0.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/880667"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-CH22-formcreateFileName-392df0aa118580c38c4ad15fb15cd30d"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-20T10:48:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CH22 formcreateFileName command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-77031",
        "datePublished": "2026-08-20T17:15:09.552Z",
        "dateReserved": "2026-08-20T08:42:56.416Z",
        "dateUpdated": "2026-08-20T18:28:50.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19924 (GCVE-0-2026-19924)

    Vulnerability from nvd – Published: 2026-08-16 01:00 – Updated: 2026-08-19 15:50
    VLAI
    Title
    Tenda AC10 httpd R7WebsSecurityHandler improper authentication
    Summary
    A security vulnerability has been detected in Tenda AC10 16.03.10.09_multi_TDE01. This vulnerability affects the function R7WebsSecurityHandler of the component httpd. The manipulation leads to improper authentication. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-19 15:49 UTC
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Tenda AC10 Affected: 16.03.10.09_multi_TDE01
        cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19924",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-19T15:49:55.747146Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-19T15:50:08.231Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd"
              ],
              "product": "AC10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.09_multi_TDE01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "teiwiet (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC10 16.03.10.09_multi_TDE01. This vulnerability affects the function R7WebsSecurityHandler of the component httpd. The manipulation leads to improper authentication. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-16T01:00:13.158Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-390174 | Tenda AC10 httpd R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/390174"
            },
            {
              "name": "VDB-390174 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/390174/cti"
            },
            {
              "name": "CVE-2026-19924 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19924"
            },
            {
              "name": "Submit #871957 | Tenda AC10 V4.0 V16.03.10.09_multi_TDE01 Improper Authentication",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/871957"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/teiwiet/tenda-ac10-vulnerabilities/blob/main/authen-bypass-tenda-ac10.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-15T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-15T07:30:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC10 httpd R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19924",
        "datePublished": "2026-08-16T01:00:13.158Z",
        "dateReserved": "2026-08-15T05:24:58.354Z",
        "dateUpdated": "2026-08-19T15:50:08.231Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19824 (GCVE-0-2026-19824)

    Vulnerability from nvd – Published: 2026-08-14 12:30 – Updated: 2026-08-14 15:02
    VLAI
    Title
    Tenda W20E addIpMacBind ipMacBindListStore stack-based overflow
    Summary
    A weakness has been identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. The affected element is the function ipMacBindListStore of the file /goform/addIpMacBind. Executing a manipulation of the argument IPMacBindRule can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 15:01 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6(1068_1546_841)_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19824",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T15:01:53.660385Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T15:02:02.160Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/869024"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6(1068_1546_841)_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "paxiot (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. The affected element is the function ipMacBindListStore of the file /goform/addIpMacBind. Executing a manipulation of the argument IPMacBindRule can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T12:30:09.845Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389957 | Tenda W20E addIpMacBind ipMacBindListStore stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389957"
            },
            {
              "name": "VDB-389957 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389957/cti"
            },
            {
              "name": "CVE-2026-19824 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19824"
            },
            {
              "name": "Submit #869024 | Tenda W20E US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/869024"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/paueger/mycve/blob/main/Tenda_W20E/5.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:35:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E addIpMacBind ipMacBindListStore stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19824",
        "datePublished": "2026-08-14T12:30:09.845Z",
        "dateReserved": "2026-08-14T05:30:23.439Z",
        "dateUpdated": "2026-08-14T15:02:02.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19823 (GCVE-0-2026-19823)

    Vulnerability from nvd – Published: 2026-08-14 12:15 – Updated: 2026-08-18 13:39
    VLAI
    Title
    Tenda W20E QoS Rule Deletion delQos formQOSRuleDel stack-based overflow
    Summary
    A security flaw has been discovered in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. Impacted is the function formQOSRuleDel of the file /goform/delQos of the component QoS Rule Deletion. Performing a manipulation of the argument qosIndex results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 13:29 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6(1068_1546_841)_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19823",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T13:29:56.831495Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T13:39:11.186Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "QoS Rule Deletion"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6(1068_1546_841)_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "paxiot (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. Impacted is the function formQOSRuleDel of the file /goform/delQos of the component QoS Rule Deletion. Performing a manipulation of the argument qosIndex results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T12:15:10.480Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389956 | Tenda W20E QoS Rule Deletion delQos formQOSRuleDel stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389956"
            },
            {
              "name": "VDB-389956 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389956/cti"
            },
            {
              "name": "CVE-2026-19823 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19823"
            },
            {
              "name": "Submit #869021 | Tenda W20E US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/869021"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/paueger/mycve/blob/main/Tenda_W20E/4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:35:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E QoS Rule Deletion delQos formQOSRuleDel stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19823",
        "datePublished": "2026-08-14T12:15:10.480Z",
        "dateReserved": "2026-08-14T05:30:19.659Z",
        "dateUpdated": "2026-08-18T13:39:11.186Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19822 (GCVE-0-2026-19822)

    Vulnerability from nvd – Published: 2026-08-14 11:30 – Updated: 2026-08-14 14:53
    VLAI
    Title
    Tenda W20E QoS Edit editQos lstAdd stack-based overflow
    Summary
    A vulnerability was identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. This issue affects the function lstAdd of the file /goform/editQos of the component QoS Edit. Such manipulation of the argument qosListConnecttedNum leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 14:53 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6(1068_1546_841)_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19822",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T14:53:17.764612Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T14:53:31.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "QoS Edit"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6(1068_1546_841)_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "paxiot (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. This issue affects the function lstAdd of the file /goform/editQos of the component QoS Edit. Such manipulation of the argument qosListConnecttedNum leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T11:30:11.772Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389955 | Tenda W20E QoS Edit editQos lstAdd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389955"
            },
            {
              "name": "VDB-389955 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389955/cti"
            },
            {
              "name": "CVE-2026-19822 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19822"
            },
            {
              "name": "Submit #869006 | Tenda W20E US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/869006"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/paueger/mycve/blob/main/Tenda_W20E/3.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:35:30.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E QoS Edit editQos lstAdd stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19822",
        "datePublished": "2026-08-14T11:30:11.772Z",
        "dateReserved": "2026-08-14T05:30:15.673Z",
        "dateUpdated": "2026-08-14T14:53:31.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19821 (GCVE-0-2026-19821)

    Vulnerability from nvd – Published: 2026-08-14 11:00 – Updated: 2026-08-18 01:53
    VLAI
    Title
    Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow
    Summary
    A vulnerability was determined in Tenda AC12 15.03.06.23_multi_TD01. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd web management interface. This manipulation of the argument rebootTime causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 01:52 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC12 Affected: 15.03.06.23_multi_TD01
        cpe:2.3:h:tenda:ac12:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19821",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T01:52:58.029275Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T01:53:10.669Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac12:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "AC12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23_multi_TD01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC12 15.03.06.23_multi_TD01. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd web management interface. This manipulation of the argument rebootTime causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T11:00:10.537Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389954 | Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389954"
            },
            {
              "name": "VDB-389954 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389954/cti"
            },
            {
              "name": "CVE-2026-19821 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19821"
            },
            {
              "name": "Submit #868922 | Tenda AC12 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868922"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/AC12/4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:34:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19821",
        "datePublished": "2026-08-14T11:00:10.537Z",
        "dateReserved": "2026-08-14T05:29:33.667Z",
        "dateUpdated": "2026-08-18T01:53:10.669Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19792 (GCVE-0-2026-19792)

    Vulnerability from nvd – Published: 2026-08-14 04:00 – Updated: 2026-08-14 10:29
    VLAI
    Title
    Tenda G0 httpd web management interface module setPortMapping buffer overflow
    Summary
    A security flaw has been discovered in Tenda G0 up to 20260625. Impacted is the function setPortMapping of the file /goform/module of the component httpd web management interface. Performing a manipulation of the argument portMappingServer/porMappingtInternal/portMappingExternal results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 10:28 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda G0 Affected: 20260625
        cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19792",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T10:28:44.132624Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T10:29:42.339Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "G0",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260625"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda G0 up to 20260625. Impacted is the function setPortMapping of the file /goform/module of the component httpd web management interface. Performing a manipulation of the argument portMappingServer/porMappingtInternal/portMappingExternal results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T04:00:09.814Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389758 | Tenda G0 httpd web management interface module setPortMapping buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389758"
            },
            {
              "name": "VDB-389758 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389758/cti"
            },
            {
              "name": "CVE-2026-19792 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19792"
            },
            {
              "name": "Submit #868929 | Tenda G0 Tenda G0 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868929"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/G0/3.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-13T21:00:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda G0 httpd web management interface module setPortMapping buffer overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19792",
        "datePublished": "2026-08-14T04:00:09.814Z",
        "dateReserved": "2026-08-13T18:55:28.591Z",
        "dateUpdated": "2026-08-14T10:29:42.339Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19791 (GCVE-0-2026-19791)

    Vulnerability from nvd – Published: 2026-08-14 03:45 – Updated: 2026-08-14 15:06
    VLAI
    Title
    Tenda G0 httpd web management interface module addStaticRoute stack-based overflow
    Summary
    A weakness has been identified in Tenda G0 up to 20260625. The affected element is the function addStaticRoute of the file /goform/module of the component httpd web management interface. Executing a manipulation of the argument staticRouteNet can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 15:06 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda G0 Affected: 20260625
        cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19791",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T15:06:14.018291Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T15:06:38.069Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/868927"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "G0",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260625"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda G0 up to 20260625. The affected element is the function addStaticRoute of the file /goform/module of the component httpd web management interface. Executing a manipulation of the argument staticRouteNet can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T03:45:08.358Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389759 | Tenda G0 httpd web management interface module addStaticRoute stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389759"
            },
            {
              "name": "VDB-389759 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389759/cti"
            },
            {
              "name": "CVE-2026-19791 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19791"
            },
            {
              "name": "Submit #868927 | Tenda G0 Tenda G0 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868927"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/G0/2.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-13T21:00:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda G0 httpd web management interface module addStaticRoute stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19791",
        "datePublished": "2026-08-14T03:45:08.358Z",
        "dateReserved": "2026-08-13T18:55:24.764Z",
        "dateUpdated": "2026-08-14T15:06:38.069Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19790 (GCVE-0-2026-19790)

    Vulnerability from nvd – Published: 2026-08-14 03:30 – Updated: 2026-08-18 13:39
    VLAI
    Title
    Tenda G0 httpd Web Management module formSetPortMirror stack-based overflow
    Summary
    A vulnerability was identified in Tenda G0 up to 20260625. This issue affects the function formSetPortMirror of the file /goform/module of the component httpd Web Management Interface. Such manipulation of the argument portMirrorMirroredPorts leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 13:30 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda G0 Affected: 20260625
        cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19790",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T13:30:04.421724Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T13:39:21.905Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Interface"
              ],
              "product": "G0",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260625"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda G0 up to 20260625. This issue affects the function formSetPortMirror of the file /goform/module of the component httpd Web Management Interface. Such manipulation of the argument portMirrorMirroredPorts leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T03:30:10.585Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389757 | Tenda G0 httpd Web Management module formSetPortMirror stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389757"
            },
            {
              "name": "VDB-389757 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389757/cti"
            },
            {
              "name": "CVE-2026-19790 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19790"
            },
            {
              "name": "Submit #868924 | Tenda G0 Tenda G0 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868924"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/G0/1.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-13T21:00:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda G0 httpd Web Management module formSetPortMirror stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19790",
        "datePublished": "2026-08-14T03:30:10.585Z",
        "dateReserved": "2026-08-13T18:55:20.872Z",
        "dateUpdated": "2026-08-18T13:39:21.905Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19789 (GCVE-0-2026-19789)

    Vulnerability from nvd – Published: 2026-08-14 03:15 – Updated: 2026-08-14 14:58
    VLAI
    Title
    Tenda AC1206 httpd web management interface WifiGuestSet set_wl_guest_iplist stack-based overflow
    Summary
    A vulnerability was determined in Tenda AC1206 15.03.06.23_multi_TD01. This vulnerability affects the function set_wl_guest_iplist of the file /goform/WifiGuestSet of the component httpd web management interface. This manipulation of the argument shareSpeed causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 14:58 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC1206 Affected: 15.03.06.23_multi_TD01
        cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19789",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T14:58:06.440073Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T14:58:17.037Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23_multi_TD01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC1206 15.03.06.23_multi_TD01. This vulnerability affects the function set_wl_guest_iplist of the file /goform/WifiGuestSet of the component httpd web management interface. This manipulation of the argument shareSpeed causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T03:15:10.028Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389756 | Tenda AC1206 httpd web management interface WifiGuestSet set_wl_guest_iplist stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389756"
            },
            {
              "name": "VDB-389756 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389756/cti"
            },
            {
              "name": "CVE-2026-19789 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19789"
            },
            {
              "name": "Submit #868921 | Tenda AC12 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868921"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/AC12/2.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-13T20:54:53.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC1206 httpd web management interface WifiGuestSet set_wl_guest_iplist stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19789",
        "datePublished": "2026-08-14T03:15:10.028Z",
        "dateReserved": "2026-08-13T18:47:57.235Z",
        "dateUpdated": "2026-08-14T14:58:17.037Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19788 (GCVE-0-2026-19788)

    Vulnerability from nvd – Published: 2026-08-14 03:00 – Updated: 2026-08-18 01:50
    VLAI
    Title
    Tenda AC1206 httpd web management interface SetOnlineDevName set_device_name stack-based overflow
    Summary
    A vulnerability was found in Tenda AC1206 15.03.06.23_multi_TD01. This affects the function set_device_name of the file /goform/SetOnlineDevName of the component httpd web management interface. The manipulation of the argument devName results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 01:50 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC1206 Affected: 15.03.06.23_multi_TD01
        cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19788",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T01:50:03.776583Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T01:50:13.412Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23_multi_TD01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC1206 15.03.06.23_multi_TD01. This affects the function set_device_name of the file /goform/SetOnlineDevName of the component httpd web management interface. The manipulation of the argument devName results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T03:00:10.875Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389755 | Tenda AC1206 httpd web management interface SetOnlineDevName set_device_name stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389755"
            },
            {
              "name": "VDB-389755 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389755/cti"
            },
            {
              "name": "CVE-2026-19788 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19788"
            },
            {
              "name": "Submit #868913 | Tenda AC12 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868913"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/AC12/1.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-13T20:53:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC1206 httpd web management interface SetOnlineDevName set_device_name stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19788",
        "datePublished": "2026-08-14T03:00:10.875Z",
        "dateReserved": "2026-08-13T18:47:53.219Z",
        "dateUpdated": "2026-08-18T01:50:13.412Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82695 (GCVE-0-2026-82695)

    Vulnerability from cvelistv5 – Published: 2026-08-31 12:45 – Updated: 2026-08-31 14:29
    VLAI
    Title
    Tenda AC18 Telnet telnet missing authentication
    Summary
    A security flaw has been discovered in Tenda AC18 15.03.05.19. Impacted is an unknown function of the file /goform/telnet of the component Telnet Handler. The manipulation results in missing authentication. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-31 14:27 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC18 Affected: 15.03.05.19
        cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82695",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-31T14:27:33.061359Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-31T14:29:57.559Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Telnet Handler"
              ],
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ST4R0003 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda AC18 15.03.05.19. Impacted is an unknown function of the file /goform/telnet of the component Telnet Handler. The manipulation results in missing authentication. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-31T12:45:09.596Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397183 | Tenda AC18 Telnet telnet missing authentication",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/397183"
            },
            {
              "name": "VDB-397183 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397183/cti"
            },
            {
              "name": "CVE-2026-82695 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82695"
            },
            {
              "name": "Submit #894242 | Tenda AC18 ac18_kf_V15.03.05.19 Missing Authentication for Critical Function",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/894242"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/TENDA-AC18-TELNET-DEFAULT-UNAUTH-001-vulndb.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-30T19:49:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC18 Telnet telnet missing authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82695",
        "datePublished": "2026-08-31T12:45:09.596Z",
        "dateReserved": "2026-08-30T17:44:12.858Z",
        "dateUpdated": "2026-08-31T14:29:57.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82694 (GCVE-0-2026-82694)

    Vulnerability from cvelistv5 – Published: 2026-08-31 12:30 – Updated: 2026-08-31 17:44
    VLAI
    Title
    Tenda AC1206 Web UI ate R7WebsSecurityHandler missing authentication
    Summary
    A vulnerability was identified in Tenda AC1206 15.03.06.23. This issue affects the function R7WebsSecurityHandler of the file /goform/ate of the component Web UI. The manipulation leads to missing authentication. The attack can be initiated remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-31 17:44 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC1206 Affected: 15.03.06.23
        cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82694",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-31T17:44:24.421345Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-31T17:44:30.348Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/894241"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web UI"
              ],
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ST4R0003 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC1206 15.03.06.23. This issue affects the function R7WebsSecurityHandler of the file /goform/ate of the component Web UI. The manipulation leads to missing authentication. The attack can be initiated remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-31T12:30:10.652Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397182 | Tenda AC1206 Web UI ate R7WebsSecurityHandler missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/397182"
            },
            {
              "name": "VDB-397182 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397182/cti"
            },
            {
              "name": "CVE-2026-82694 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82694"
            },
            {
              "name": "Submit #894241 | Tenda AC1206 V1.0 RTL / F1203-class web UI V15.03.06.23 Missing Authentication for Critical Function\u0026Exposed Dangerous M",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/894241"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/TENDA-AC1206-ATE-DEFAULT-UNAUTH-002-vulndb.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-30T19:47:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC1206 Web UI ate R7WebsSecurityHandler missing authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82694",
        "datePublished": "2026-08-31T12:30:10.652Z",
        "dateReserved": "2026-08-30T17:42:07.633Z",
        "dateUpdated": "2026-08-31T17:44:30.348Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82693 (GCVE-0-2026-82693)

    Vulnerability from cvelistv5 – Published: 2026-08-31 12:15 – Updated: 2026-08-31 22:03
    VLAI
    Title
    Tenda AC1206 Web UI telnet TendaTelnet missing authentication
    Summary
    A vulnerability was determined in Tenda AC1206 15.03.06.23. This vulnerability affects the function TendaTelnet of the file /goform/telnet of the component Web UI. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-31 21:56 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC1206 Affected: 15.03.06.23
        cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82693",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-31T21:56:58.989833Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-31T22:03:13.167Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac1206_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web UI"
              ],
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ST4R0003 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC1206 15.03.06.23. This vulnerability affects the function TendaTelnet of the file /goform/telnet of the component Web UI. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-31T12:15:12.193Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397181 | Tenda AC1206 Web UI telnet TendaTelnet missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/397181"
            },
            {
              "name": "VDB-397181 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397181/cti"
            },
            {
              "name": "CVE-2026-82693 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82693"
            },
            {
              "name": "Submit #894235 | Tenda AC1206 V1.0 RTL / F1203-class web UI V15.03.06.23 Missing Authentication for Critical Function\u0026Missing Authorizati",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/894235"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/TENDA-AC1206-TELNET-DEFAULT-UNAUTH-001-vulndb.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-30T19:47:14.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC1206 Web UI telnet TendaTelnet missing authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82693",
        "datePublished": "2026-08-31T12:15:12.193Z",
        "dateReserved": "2026-08-30T17:42:02.868Z",
        "dateUpdated": "2026-08-31T22:03:13.167Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82542 (GCVE-0-2026-82542)

    Vulnerability from cvelistv5 – Published: 2026-08-30 12:30 – Updated: 2026-09-01 14:02
    VLAI
    Title
    Tenda HG10 Boa Web Server formIPv6Routing buffer overflow
    Summary
    A weakness has been identified in Tenda HG10 300001138. Affected by this issue is the function formIPv6Routing of the file /boaform/admin/formIPv6Routing of the component Boa Web Server. This manipulation of the argument destNet causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-01 14:01 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82542",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-01T14:01:41.330939Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-01T14:02:01.116Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda HG10 300001138. Affected by this issue is the function formIPv6Routing of the file /boaform/admin/formIPv6Routing of the component Boa Web Server. This manipulation of the argument destNet causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-30T12:30:09.679Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-397058 | Tenda HG10 Boa Web Server formIPv6Routing buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/397058"
            },
            {
              "name": "VDB-397058 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/397058/cti"
            },
            {
              "name": "CVE-2026-82542 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-82542"
            },
            {
              "name": "Submit #888876 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/888876"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formIPv6Route-destNt.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-29T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-29T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-29T19:49:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Web Server formIPv6Routing buffer overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-82542",
        "datePublished": "2026-08-30T12:30:09.679Z",
        "dateReserved": "2026-08-29T17:43:55.683Z",
        "dateUpdated": "2026-09-01T14:02:01.116Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-78141 (GCVE-0-2026-78141)

    Vulnerability from cvelistv5 – Published: 2026-08-23 21:45 – Updated: 2026-08-27 14:38
    VLAI Shadowserver Previdian
    Title
    Tenda CH22 exeCommand formexeCommand command injection
    Summary
    A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function formexeCommand of the file /goform/exeCommand. The manipulation of the argument cmdinput leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-27 13:28 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda CH22 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-78141",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-27T13:28:03.286475Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-27T14:38:00.837Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CH22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function formexeCommand of the file /goform/exeCommand. The manipulation of the argument cmdinput leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-23T21:45:09.069Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-394524 | Tenda CH22 exeCommand formexeCommand command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/394524"
            },
            {
              "name": "VDB-394524 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/394524/cti"
            },
            {
              "name": "CVE-2026-78141 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-78141"
            },
            {
              "name": "Submit #882284 | Tenda CH22 V1.0.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/882284"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-CH22-formexeCommand-396df0aa11858036b0cdf7a7562d4a67"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-23T08:02:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CH22 exeCommand formexeCommand command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-78141",
        "datePublished": "2026-08-23T21:45:09.069Z",
        "dateReserved": "2026-08-23T05:57:32.107Z",
        "dateUpdated": "2026-08-27T14:38:00.837Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-78063 (GCVE-0-2026-78063)

    Vulnerability from cvelistv5 – Published: 2026-08-23 04:30 – Updated: 2026-08-24 15:13
    VLAI
    Title
    Tenda CH22 editFileName formeditFileName command injection
    Summary
    A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formeditFileName of the file /goform/editFileName. The manipulation of the argument editNameMit results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-24 15:13 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda CH22 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-78063",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-24T15:13:41.098101Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-24T15:13:50.632Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CH22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formeditFileName of the file /goform/editFileName. The manipulation of the argument editNameMit results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-23T04:30:10.230Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-394303 | Tenda CH22 editFileName formeditFileName command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/394303"
            },
            {
              "name": "VDB-394303 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/394303/cti"
            },
            {
              "name": "CVE-2026-78063 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-78063"
            },
            {
              "name": "Submit #881838 | Tenda CH22 V1.0.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/881838"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-CH22-formeditFileName-396df0aa1185804c9dcff01778515d32"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-22T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-22T13:08:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CH22 editFileName formeditFileName command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-78063",
        "datePublished": "2026-08-23T04:30:10.230Z",
        "dateReserved": "2026-08-22T11:03:32.176Z",
        "dateUpdated": "2026-08-24T15:13:50.632Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77031 (GCVE-0-2026-77031)

    Vulnerability from cvelistv5 – Published: 2026-08-20 17:15 – Updated: 2026-08-20 18:28
    VLAI
    Title
    Tenda CH22 formcreateFileName command injection
    Summary
    A vulnerability has been found in Tenda CH22 1.0.0.1. The affected element is the function formcreateFileName of the file /goform/formcreateFileName. The manipulation of the argument fileNameMit leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-20 18:28 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda CH22 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-77031",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-20T18:28:41.348933Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-20T18:28:50.477Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CH22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn0121 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda CH22 1.0.0.1. The affected element is the function formcreateFileName of the file /goform/formcreateFileName. The manipulation of the argument fileNameMit leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-20T17:15:09.552Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-393642 | Tenda CH22 formcreateFileName command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/393642"
            },
            {
              "name": "VDB-393642 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/393642/cti"
            },
            {
              "name": "CVE-2026-77031 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-77031"
            },
            {
              "name": "Submit #880667 | Tenda CH22 V1.0.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/880667"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-CH22-formcreateFileName-392df0aa118580c38c4ad15fb15cd30d"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-20T10:48:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CH22 formcreateFileName command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-77031",
        "datePublished": "2026-08-20T17:15:09.552Z",
        "dateReserved": "2026-08-20T08:42:56.416Z",
        "dateUpdated": "2026-08-20T18:28:50.477Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19924 (GCVE-0-2026-19924)

    Vulnerability from cvelistv5 – Published: 2026-08-16 01:00 – Updated: 2026-08-19 15:50
    VLAI
    Title
    Tenda AC10 httpd R7WebsSecurityHandler improper authentication
    Summary
    A security vulnerability has been detected in Tenda AC10 16.03.10.09_multi_TDE01. This vulnerability affects the function R7WebsSecurityHandler of the component httpd. The manipulation leads to improper authentication. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-19 15:49 UTC
    CWE
    • CWE-287 - Improper Authentication
    References
    Impacted products
    Vendor Product Version
    Tenda AC10 Affected: 16.03.10.09_multi_TDE01
        cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19924",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-19T15:49:55.747146Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-19T15:50:08.231Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd"
              ],
              "product": "AC10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.09_multi_TDE01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "teiwiet (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC10 16.03.10.09_multi_TDE01. This vulnerability affects the function R7WebsSecurityHandler of the component httpd. The manipulation leads to improper authentication. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-16T01:00:13.158Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-390174 | Tenda AC10 httpd R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/390174"
            },
            {
              "name": "VDB-390174 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/390174/cti"
            },
            {
              "name": "CVE-2026-19924 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19924"
            },
            {
              "name": "Submit #871957 | Tenda AC10 V4.0 V16.03.10.09_multi_TDE01 Improper Authentication",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/871957"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/teiwiet/tenda-ac10-vulnerabilities/blob/main/authen-bypass-tenda-ac10.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-15T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-15T07:30:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC10 httpd R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19924",
        "datePublished": "2026-08-16T01:00:13.158Z",
        "dateReserved": "2026-08-15T05:24:58.354Z",
        "dateUpdated": "2026-08-19T15:50:08.231Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19824 (GCVE-0-2026-19824)

    Vulnerability from cvelistv5 – Published: 2026-08-14 12:30 – Updated: 2026-08-14 15:02
    VLAI
    Title
    Tenda W20E addIpMacBind ipMacBindListStore stack-based overflow
    Summary
    A weakness has been identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. The affected element is the function ipMacBindListStore of the file /goform/addIpMacBind. Executing a manipulation of the argument IPMacBindRule can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 15:01 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6(1068_1546_841)_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19824",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T15:01:53.660385Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T15:02:02.160Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://vuldb.com/submit/869024"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6(1068_1546_841)_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "paxiot (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. The affected element is the function ipMacBindListStore of the file /goform/addIpMacBind. Executing a manipulation of the argument IPMacBindRule can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T12:30:09.845Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389957 | Tenda W20E addIpMacBind ipMacBindListStore stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389957"
            },
            {
              "name": "VDB-389957 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389957/cti"
            },
            {
              "name": "CVE-2026-19824 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19824"
            },
            {
              "name": "Submit #869024 | Tenda W20E US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/869024"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/paueger/mycve/blob/main/Tenda_W20E/5.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:35:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E addIpMacBind ipMacBindListStore stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19824",
        "datePublished": "2026-08-14T12:30:09.845Z",
        "dateReserved": "2026-08-14T05:30:23.439Z",
        "dateUpdated": "2026-08-14T15:02:02.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19823 (GCVE-0-2026-19823)

    Vulnerability from cvelistv5 – Published: 2026-08-14 12:15 – Updated: 2026-08-18 13:39
    VLAI
    Title
    Tenda W20E QoS Rule Deletion delQos formQOSRuleDel stack-based overflow
    Summary
    A security flaw has been discovered in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. Impacted is the function formQOSRuleDel of the file /goform/delQos of the component QoS Rule Deletion. Performing a manipulation of the argument qosIndex results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 13:29 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6(1068_1546_841)_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19823",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T13:29:56.831495Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T13:39:11.186Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "QoS Rule Deletion"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6(1068_1546_841)_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "paxiot (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. Impacted is the function formQOSRuleDel of the file /goform/delQos of the component QoS Rule Deletion. Performing a manipulation of the argument qosIndex results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T12:15:10.480Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389956 | Tenda W20E QoS Rule Deletion delQos formQOSRuleDel stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389956"
            },
            {
              "name": "VDB-389956 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389956/cti"
            },
            {
              "name": "CVE-2026-19823 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19823"
            },
            {
              "name": "Submit #869021 | Tenda W20E US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/869021"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/paueger/mycve/blob/main/Tenda_W20E/4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:35:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E QoS Rule Deletion delQos formQOSRuleDel stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19823",
        "datePublished": "2026-08-14T12:15:10.480Z",
        "dateReserved": "2026-08-14T05:30:19.659Z",
        "dateUpdated": "2026-08-18T13:39:11.186Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19822 (GCVE-0-2026-19822)

    Vulnerability from cvelistv5 – Published: 2026-08-14 11:30 – Updated: 2026-08-14 14:53
    VLAI
    Title
    Tenda W20E QoS Edit editQos lstAdd stack-based overflow
    Summary
    A vulnerability was identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. This issue affects the function lstAdd of the file /goform/editQos of the component QoS Edit. Such manipulation of the argument qosListConnecttedNum leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 14:53 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.6(1068_1546_841)_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19822",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T14:53:17.764612Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T14:53:31.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "QoS Edit"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.6(1068_1546_841)_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "paxiot (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda W20E 15.11.0.6(1068_1546_841)_CN_TDC. This issue affects the function lstAdd of the file /goform/editQos of the component QoS Edit. Such manipulation of the argument qosListConnecttedNum leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T11:30:11.772Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389955 | Tenda W20E QoS Edit editQos lstAdd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389955"
            },
            {
              "name": "VDB-389955 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389955/cti"
            },
            {
              "name": "CVE-2026-19822 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19822"
            },
            {
              "name": "Submit #869006 | Tenda W20E US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/869006"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/paueger/mycve/blob/main/Tenda_W20E/3.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:35:30.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E QoS Edit editQos lstAdd stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19822",
        "datePublished": "2026-08-14T11:30:11.772Z",
        "dateReserved": "2026-08-14T05:30:15.673Z",
        "dateUpdated": "2026-08-14T14:53:31.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19821 (GCVE-0-2026-19821)

    Vulnerability from cvelistv5 – Published: 2026-08-14 11:00 – Updated: 2026-08-18 01:53
    VLAI
    Title
    Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow
    Summary
    A vulnerability was determined in Tenda AC12 15.03.06.23_multi_TD01. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd web management interface. This manipulation of the argument rebootTime causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 01:52 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda AC12 Affected: 15.03.06.23_multi_TD01
        cpe:2.3:h:tenda:ac12:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19821",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T01:52:58.029275Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T01:53:10.669Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac12:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "AC12",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.23_multi_TD01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC12 15.03.06.23_multi_TD01. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd web management interface. This manipulation of the argument rebootTime causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T11:00:10.537Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389954 | Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389954"
            },
            {
              "name": "VDB-389954 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389954/cti"
            },
            {
              "name": "CVE-2026-19821 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19821"
            },
            {
              "name": "Submit #868922 | Tenda AC12 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01.bin Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868922"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/AC12/4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-14T07:34:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19821",
        "datePublished": "2026-08-14T11:00:10.537Z",
        "dateReserved": "2026-08-14T05:29:33.667Z",
        "dateUpdated": "2026-08-18T01:53:10.669Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19792 (GCVE-0-2026-19792)

    Vulnerability from cvelistv5 – Published: 2026-08-14 04:00 – Updated: 2026-08-14 10:29
    VLAI
    Title
    Tenda G0 httpd web management interface module setPortMapping buffer overflow
    Summary
    A security flaw has been discovered in Tenda G0 up to 20260625. Impacted is the function setPortMapping of the file /goform/module of the component httpd web management interface. Performing a manipulation of the argument portMappingServer/porMappingtInternal/portMappingExternal results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-14 10:28 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda G0 Affected: 20260625
        cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19792",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-14T10:28:44.132624Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-14T10:29:42.339Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:g0:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd web management interface"
              ],
              "product": "G0",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260625"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "stksgg (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda G0 up to 20260625. Impacted is the function setPortMapping of the file /goform/module of the component httpd web management interface. Performing a manipulation of the argument portMappingServer/porMappingtInternal/portMappingExternal results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-14T04:00:09.814Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-389758 | Tenda G0 httpd web management interface module setPortMapping buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/389758"
            },
            {
              "name": "VDB-389758 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/389758/cti"
            },
            {
              "name": "CVE-2026-19792 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19792"
            },
            {
              "name": "Submit #868929 | Tenda G0 Tenda G0 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/868929"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lipenghai/iot_bug/blob/main/Tenda/G0/3.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-13T21:00:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda G0 httpd web management interface module setPortMapping buffer overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19792",
        "datePublished": "2026-08-14T04:00:09.814Z",
        "dateReserved": "2026-08-13T18:55:28.591Z",
        "dateUpdated": "2026-08-14T10:29:42.339Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }