CWE-345
DiscouragedInsufficient Verification of Data Authenticity
Abstraction: Class · Status: Draft
The product does not sufficiently verify the origin or authenticity of data, in a way that causes it to accept invalid data.
942 vulnerabilities reference this CWE, most recent first.
CVE-2023-32329 (GCVE-0-2023-32329)
Vulnerability from cvelistv5 – Published: 2024-02-03 01:00 – Updated: 2025-11-03 21:48- CWE-345 - Insufficient Verification of Data Authenticity
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7106586 | vendor-advisory |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entry |
| http://seclists.org/fulldisclosure/2024/Nov/0 |
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Security Verify Access Appliance |
Affected:
10.0.0.0 , ≤ 10.0.6.1
(semver)
|
|
| IBM | Security Verify Access Docker |
Affected:
10.0.0.0 , ≤ 10.0.6.1
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:48:30.079Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ibm.com/support/pages/node/7106586"
},
{
"tags": [
"vdb-entry",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/254972"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Nov/0"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32329",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T14:12:29.249196Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T14:12:47.242Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Security Verify Access Appliance",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "10.0.6.1",
"status": "affected",
"version": "10.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Security Verify Access Docker",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "10.0.6.1",
"status": "affected",
"version": "10.0.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Security Access Manager Container (IBM Security Verify Access Appliance 10.0.0.0 through 10.0.6.1 and IBM Security Verify Access Docker 10.0.0.0 through 10.0.6.1) could allow a user to download files from an incorrect repository due to improper file validation. IBM X-Force ID: 254972."
}
],
"value": "IBM Security Access Manager Container (IBM Security Verify Access Appliance 10.0.0.0 through 10.0.6.1 and IBM Security Verify Access Docker 10.0.0.0 through 10.0.6.1) could allow a user to download files from an incorrect repository due to improper file validation. IBM X-Force ID: 254972."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-03T01:00:15.237Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ibm.com/support/pages/node/7106586"
},
{
"tags": [
"vdb-entry"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/254972"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Security Access Manager Container improper file validation",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2023-32329",
"datePublished": "2024-02-03T01:00:15.237Z",
"dateReserved": "2023-05-08T18:32:34.087Z",
"dateUpdated": "2025-11-03T21:48:30.079Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-30562 (GCVE-0-2023-30562)
Vulnerability from cvelistv5 – Published: 2023-07-13 19:03 – Updated: 2024-10-22 16:07- CWE-345 - Insufficient Verification of Data Authenticity
| Vendor | Product | Version | |
|---|---|---|---|
| Becton Dickinson & Co | BD Alarisâ„¢ Guardrailsâ„¢ Editor |
Affected:
0 , ≤ 12.1.2
(custom)
Affected: 0 , ≤ 12.3 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:28:51.621Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-alaris-system-with-guardrails-suite-mx"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-30562",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-22T15:49:05.412286Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-22T16:07:32.582Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BD Alaris\u00e2\u201e\u00a2 Guardrails\u00e2\u201e\u00a2 Editor",
"vendor": "Becton Dickinson \u0026 Co",
"versions": [
{
"lessThanOrEqual": "12.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "12.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-07-13T15:33:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs. \n\n\n\n"
}
],
"value": "A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs. \n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-17",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-17 Using Malicious Files"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "For the BD Alaris\u00e2\u201e\u00a2 Infusion System 12.1.3 (GRE 12.1.2) and earlier versions"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "For the BD Alaris\u00e2\u201e\u00a2 Infusion System version 12.3 (GRE 12.1.3)"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-26T16:45:05.543Z",
"orgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18",
"shortName": "BD"
},
"references": [
{
"url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-alaris-system-with-guardrails-suite-mx"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Lack of Dataset Integrity Checking ",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18",
"assignerShortName": "BD",
"cveId": "CVE-2023-30562",
"datePublished": "2023-07-13T19:03:32.964Z",
"dateReserved": "2023-04-12T16:30:07.537Z",
"dateUpdated": "2024-10-22T16:07:32.582Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-30559 (GCVE-0-2023-30559)
Vulnerability from cvelistv5 – Published: 2023-07-13 17:50 – Updated: 2024-08-02 14:28| Vendor | Product | Version | |
|---|---|---|---|
| Becton Dickinson & Co | BD Alaris™ Point-of-Care Unit (PCU) Model 8015 |
Affected:
0 , ≤ 12.1.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:28:51.809Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-alaris-system-with-guardrails-suite-mx"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BD Alaris\u2122 Point-of-Care Unit (PCU) Model 8015",
"vendor": "Becton Dickinson \u0026 Co ",
"versions": [
{
"lessThanOrEqual": "12.1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-07-13T14:59:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The firmware update package for the wireless card is not properly signed and can be modified."
}
],
"value": "The firmware update package for the wireless card is not properly signed and can be modified."
}
],
"impacts": [
{
"capecId": "CAPEC-638",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-638 Altered Component Firmware"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-08T21:52:28.547Z",
"orgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18",
"shortName": "BD"
},
"references": [
{
"url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-alaris-system-with-guardrails-suite-mx"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Wireless Card Firmware Improperly Signed",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18",
"assignerShortName": "BD",
"cveId": "CVE-2023-30559",
"datePublished": "2023-07-13T17:50:13.176Z",
"dateReserved": "2023-04-12T16:30:07.536Z",
"dateUpdated": "2024-08-02T14:28:51.809Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27982 (GCVE-0-2023-27982)
Vulnerability from cvelistv5 – Published: 2023-03-21 00:00 – Updated: 2025-02-05 20:05- CWE-345 - Insufficient Verification of Data Authenticity
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | IGSS Data Server(IGSSdataServer.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
|
| Schneider Electric | IGSS Dashboard (DashBoard.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
|
| Schneider Electric | Custom Reports (RMS16.dll) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:23:30.893Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-27982",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:51:49.336611Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:05:29.007Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IGSS Data Server(IGSSdataServer.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "IGSS Dashboard (DashBoard.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "Custom Reports (RMS16.dll)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-21T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-27982",
"datePublished": "2023-03-21T00:00:00.000Z",
"dateReserved": "2023-03-09T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:05:29.007Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27979 (GCVE-0-2023-27979)
Vulnerability from cvelistv5 – Published: 2023-03-21 00:00 – Updated: 2025-02-05 20:05- CWE-345 - Insufficient Verification of Data Authenticity
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | IGSS Data Server(IGSSdataServer.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
|
| Schneider Electric | IGSS Dashboard (DashBoard.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
|
| Schneider Electric | Custom Reports (RMS16.dll) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:23:30.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-27979",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:54:48.377987Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:05:51.982Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IGSS Data Server(IGSSdataServer.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "IGSS Dashboard (DashBoard.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "Custom Reports (RMS16.dll)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-21T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-27979",
"datePublished": "2023-03-21T00:00:00.000Z",
"dateReserved": "2023-03-09T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:05:51.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27977 (GCVE-0-2023-27977)
Vulnerability from cvelistv5 – Published: 2023-03-21 00:00 – Updated: 2025-02-05 20:06- CWE-345 - Insufficient Verification of Data Authenticity
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | IGSS Data Server(IGSSdataServer.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
|
| Schneider Electric | IGSS Dashboard (DashBoard.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
|
| Schneider Electric | Custom Reports (RMS16.dll) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:23:30.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-27977",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:54:51.275436Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:06.896Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IGSS Data Server(IGSSdataServer.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "IGSS Dashboard (DashBoard.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "Custom Reports (RMS16.dll)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-21T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-27977",
"datePublished": "2023-03-21T00:00:00.000Z",
"dateReserved": "2023-03-09T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:06.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27360 (GCVE-0-2023-27360)
Vulnerability from cvelistv5 – Published: 2024-05-03 01:56 – Updated: 2024-08-02 12:09- CWE-345 - Insufficient Verification of Data Authenticity
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| https://kb.netgear.com/000065559/Security-Advisor… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| NETGEAR | RAX30 |
Affected:
1.0.6.74_1
|
|
| netgear | rax30_firmware |
Affected:
0 , < 1.0.10.94
(custom)
cpe:2.3:o:netgear:rax30_firmware:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:netgear:rax30_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rax30_firmware",
"vendor": "netgear",
"versions": [
{
"lessThan": "1.0.10.94",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-27360",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T19:07:41.378327Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T19:07:46.711Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:09:43.274Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-496",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-496/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://kb.netgear.com/000065559/Security-Advisory-for-Multiple-Vulnerabilities-on-the-RAX30-PSV-2022-0352"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RAX30",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "1.0.6.74_1"
}
]
}
],
"dateAssigned": "2023-02-28T18:05:54.092Z",
"datePublic": "2023-05-01T21:29:47.637Z",
"descriptions": [
{
"lang": "en",
"value": "NETGEAR RAX30 lighttpd Misconfiguration Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR RAX30. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the lighttpd HTTP server. The issue results from allowing execution of files from untrusted sources. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-19398."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T01:56:12.177Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-496",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-496/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://kb.netgear.com/000065559/Security-Advisory-for-Multiple-Vulnerabilities-on-the-RAX30-PSV-2022-0352"
}
],
"source": {
"lang": "en",
"value": "Rocco Calvi and Steven Seeley of Incite Team"
},
"title": "NETGEAR RAX30 lighttpd Misconfiguration Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-27360",
"datePublished": "2024-05-03T01:56:12.177Z",
"dateReserved": "2023-02-28T17:58:45.483Z",
"dateUpdated": "2024-08-02T12:09:43.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-26481 (GCVE-0-2023-26481)
Vulnerability from cvelistv5 – Published: 2023-03-04 00:30 – Updated: 2025-02-25 15:01- CWE-345 - Insufficient Verification of Data Authenticity
| URL | Tags |
|---|---|
| https://github.com/goauthentik/authentik/security… | x_refsource_CONFIRM |
| https://goauthentik.io/docs/releases/2023.2#fixed… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| goauthentik | authentik |
Affected:
< 2023.2.3
Affected: < 2023.1.3 Affected: < 2022.12.2 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:53:53.981Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://github.com/goauthentik/authentik/security/advisories/GHSA-3xf5-pqvf-rqq3",
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/goauthentik/authentik/security/advisories/GHSA-3xf5-pqvf-rqq3"
},
{
"name": "https://goauthentik.io/docs/releases/2023.2#fixed-in-202323",
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://goauthentik.io/docs/releases/2023.2#fixed-in-202323"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-26481",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-25T14:29:59.847692Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-25T15:01:34.943Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "authentik",
"vendor": "goauthentik",
"versions": [
{
"status": "affected",
"version": "\u003c 2023.2.3"
},
{
"status": "affected",
"version": "\u003c 2023.1.3"
},
{
"status": "affected",
"version": "\u003c 2022.12.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "authentik is an open-source Identity Provider. Due to an insufficient access check, a recovery flow link that is created by an admin (or sent via email by an admin) can be used to set the password for any arbitrary user. This attack is only possible if a recovery flow exists, which has both an Identification and an Email stage bound to it. If the flow has policies on the identification stage to skip it when the flow is restored (by checking `request.context[\u0027is_restored\u0027]`), the flow is not affected by this. With this flow in place, an administrator must create a recovery Link or send a recovery URL to the attacker, who can, due to the improper validation of the token create, set the password for any account. Regardless, for custom recovery flows it is recommended to add a policy that checks if the flow is restored, and skips the identification stage. This issue has been fixed in versions 2023.2.3, 2023.1.3 and 2022.12.2.\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-04T00:30:16.509Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/goauthentik/authentik/security/advisories/GHSA-3xf5-pqvf-rqq3",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/goauthentik/authentik/security/advisories/GHSA-3xf5-pqvf-rqq3"
},
{
"name": "https://goauthentik.io/docs/releases/2023.2#fixed-in-202323",
"tags": [
"x_refsource_MISC"
],
"url": "https://goauthentik.io/docs/releases/2023.2#fixed-in-202323"
}
],
"source": {
"advisory": "GHSA-3xf5-pqvf-rqq3",
"discovery": "UNKNOWN"
},
"title": "Insufficient user check in FlowTokens by Email stage"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2023-26481",
"datePublished": "2023-03-04T00:30:16.509Z",
"dateReserved": "2023-02-23T23:22:58.574Z",
"dateUpdated": "2025-02-25T15:01:34.943Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-26467 (GCVE-0-2023-26467)
Vulnerability from cvelistv5 – Published: 2023-04-10 00:00 – Updated: 2025-02-07 20:12- CWE-345 - Insufficient Verification of Data Authenticity
| Vendor | Product | Version | |
|---|---|---|---|
| Pegasystems | RPA: Synchronization Engine |
Affected:
3.1.1 , < unspecified
(custom)
Affected: unspecified , < 3.1.28 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:53:53.593Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.pega.com/support-doc/pega-security-advisory-b23-robotics-and-workforce-intelligence-local-privilege"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-26467",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T20:12:47.348361Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T20:12:55.654Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RPA: Synchronization Engine",
"vendor": "Pegasystems",
"versions": [
{
"lessThan": "unspecified",
"status": "affected",
"version": "3.1.1",
"versionType": "custom"
},
{
"lessThan": "3.1.28",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Skyler Knecht and William Martin from the Adversarial Security Practice at Navy Federal Credit Union"
}
],
"descriptions": [
{
"lang": "en",
"value": "A man in the middle can redirect traffic to a malicious server in a compromised configuration."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-10T00:00:00.000Z",
"orgId": "c91e5604-2bd1-401f-a0ec-b25342b57ef9",
"shortName": "Pega"
},
"references": [
{
"url": "https://support.pega.com/support-doc/pega-security-advisory-b23-robotics-and-workforce-intelligence-local-privilege"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c91e5604-2bd1-401f-a0ec-b25342b57ef9",
"assignerShortName": "Pega",
"cveId": "CVE-2023-26467",
"datePublished": "2023-04-10T00:00:00.000Z",
"dateReserved": "2023-02-23T00:00:00.000Z",
"dateUpdated": "2025-02-07T20:12:55.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25178 (GCVE-0-2023-25178)
Vulnerability from cvelistv5 – Published: 2023-07-13 10:59 – Updated: 2025-03-05 18:50- CWE-345 - Insufficient Verification of Data Authenticity
| URL | Tags |
|---|---|
| https://process.honeywell.com |
| Vendor | Product | Version | |
|---|---|---|---|
| Honeywell | C300 |
Affected:
501.1 , ≤ 501.6HF8
(semver)
Affected: 510.1 , ≤ 510.2HF12 (semver) Affected: 511.1 , ≤ 511.5TCU3 (semver) Affected: 520.1 , ≤ 520.1TCU4 (semver) Affected: 520.2 , ≤ 520.2TCU2 (semver) |
|
| Honeywell | C300 |
Affected:
510.1 , ≤ 511.5TCU3
(semver)
Affected: 520.1 , ≤ 520.1TCU4 (semver) Affected: 520.2 , ≤ 520.2TCU2 (semver) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:18:35.746Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://process.honeywell.com"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25178",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-05T18:39:56.713815Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-05T18:50:28.752Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "C300",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "501.6HF8",
"status": "affected",
"version": "501.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "510.2HF12",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5TCU3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.2TCU2",
"status": "affected",
"version": "520.2",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion LX",
"Experion PlantCruise"
],
"product": "C300",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "511.5TCU3",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.2TCU2",
"status": "affected",
"version": "520.2",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Controller may be loaded with malicious firmware which could enable remote code execution.\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSee Honeywell Security Notification for recommendations on upgrading and versioning. \u003c/span\u003e\n\n"
}
],
"value": "Controller may be loaded with malicious firmware which could enable remote code execution.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning. \n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-638",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-638 Altered Component Firmware"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-22T16:03:44.238Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Controller design flaw - unsigned firmware",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-25178",
"datePublished": "2023-07-13T10:59:16.333Z",
"dateReserved": "2023-02-28T23:51:16.663Z",
"dateUpdated": "2025-03-05T18:50:28.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
CAPEC-111: JSON Hijacking (aka JavaScript Hijacking)
An attacker targets a system that uses JavaScript Object Notation (JSON) as a transport mechanism between the client and the server (common in Web 2.0 systems using AJAX) to steal possibly confidential information transmitted from the server back to the client inside the JSON object by taking advantage of the loophole in the browser's Same Origin Policy that does not prohibit JavaScript from one website to be included and executed in the context of another website.
CAPEC-141: Cache Poisoning
An attacker exploits the functionality of cache technologies to cause specific data to be cached that aids the attackers' objectives. This describes any attack whereby an attacker places incorrect or harmful material in cache. The targeted cache can be an application's cache (e.g. a web browser cache) or a public cache (e.g. a DNS or ARP cache). Until the cache is refreshed, most applications or clients will treat the corrupted cache value as valid. This can lead to a wide range of exploits including redirecting web browsers towards sites that install malware and repeatedly incorrect calculations based on the incorrect value.
CAPEC-142: DNS Cache Poisoning
A domain name server translates a domain name (such as www.example.com) into an IP address that Internet hosts use to contact Internet resources. An adversary modifies a public DNS cache to cause certain names to resolve to incorrect addresses that the adversary specifies. The result is that client applications that rely upon the targeted cache for domain name resolution will be directed not to the actual address of the specified domain name but to some other address. Adversaries can use this to herd clients to sites that install malware on the victim's computer or to masquerade as part of a Pharming attack.
CAPEC-148: Content Spoofing
An adversary modifies content to make it contain something other than what the original content producer intended while keeping the apparent source of the content unchanged. The term content spoofing is most often used to describe modification of web pages hosted by a target to display the adversary's content instead of the owner's content. However, any content can be spoofed, including the content of email messages, file transfers, or the content of other network communication protocols. Content can be modified at the source (e.g. modifying the source file for a web page) or in transit (e.g. intercepting and modifying a message between the sender and recipient). Usually, the adversary will attempt to hide the fact that the content has been modified, but in some cases, such as with web site defacement, this is not necessary. Content Spoofing can lead to malware exposure, financial fraud (if the content governs financial transactions), privacy violations, and other unwanted outcomes.
CAPEC-218: Spoofing of UDDI/ebXML Messages
An attacker spoofs a UDDI, ebXML, or similar message in order to impersonate a service provider in an e-business transaction. UDDI, ebXML, and similar standards are used to identify businesses in e-business transactions. Among other things, they identify a particular participant, WSDL information for SOAP transactions, and supported communication protocols, including security protocols. By spoofing one of these messages an attacker could impersonate a legitimate business in a transaction or could manipulate the protocols used between a client and business. This could result in disclosure of sensitive information, loss of message integrity, or even financial fraud.
CAPEC-384: Application API Message Manipulation via Man-in-the-Middle
An attacker manipulates either egress or ingress data from a client within an application framework in order to change the content of messages. Performing this attack can allow the attacker to gain unauthorized privileges within the application, or conduct attacks such as phishing, deceptive strategies to spread malware, or traditional web-application attacks. The techniques require use of specialized software that allow the attacker to perform adversary-in-the-middle (CAPEC-94) communications between the web browser and the remote system. Despite the use of AiTH software, the attack is actually directed at the server, as the client is one node in a series of content brokers that pass information along to the application framework. Additionally, it is not true "Adversary-in-the-Middle" attack at the network layer, but an application-layer attack the root cause of which is the master applications trust in the integrity of code supplied by the client.
CAPEC-385: Transaction or Event Tampering via Application API Manipulation
An attacker hosts or joins an event or transaction within an application framework in order to change the content of messages or items that are being exchanged. Performing this attack allows the attacker to manipulate content in such a way as to produce messages or content that look authentic but may contain deceptive links, substitute one item or another, spoof an existing item and conduct a false exchange, or otherwise change the amounts or identity of what is being exchanged. The techniques require use of specialized software that allow the attacker to man-in-the-middle communications between the web browser and the remote system in order to change the content of various application elements. Often, items exchanged in game can be monetized via sales for coin, virtual dollars, etc. The purpose of the attack is for the attack to scam the victim by trapping the data packets involved the exchange and altering the integrity of the transfer process.
CAPEC-386: Application API Navigation Remapping
An attacker manipulates either egress or ingress data from a client within an application framework in order to change the destination and/or content of links/buttons displayed to a user within API messages. Performing this attack allows the attacker to manipulate content in such a way as to produce messages or content that looks authentic but contains links/buttons that point to an attacker controlled destination. Some applications make navigation remapping more difficult to detect because the actual HREF values of images, profile elements, and links/buttons are masked. One example would be to place an image in a user's photo gallery that when clicked upon redirected the user to an off-site location. Also, traditional web vulnerabilities (such as CSRF) can be constructed with remapped buttons or links. In some cases navigation remapping can be used for Phishing attacks or even means to artificially boost the page view, user site reputation, or click-fraud.
CAPEC-387: Navigation Remapping To Propagate Malicious Content
An adversary manipulates either egress or ingress data from a client within an application framework in order to change the content of messages and thereby circumvent the expected application logic.
CAPEC-388: Application API Button Hijacking
An attacker manipulates either egress or ingress data from a client within an application framework in order to change the destination and/or content of buttons displayed to a user within API messages. Performing this attack allows the attacker to manipulate content in such a way as to produce messages or content that looks authentic but contains buttons that point to an attacker controlled destination.
CAPEC-665: Exploitation of Thunderbolt Protection Flaws
An adversary leverages a firmware weakness within the Thunderbolt protocol, on a computing device to manipulate Thunderbolt controller firmware in order to exploit vulnerabilities in the implementation of authorization and verification schemes within Thunderbolt protection mechanisms. Upon gaining physical access to a target device, the adversary conducts high-level firmware manipulation of the victim Thunderbolt controller SPI (Serial Peripheral Interface) flash, through the use of a SPI Programing device and an external Thunderbolt device, typically as the target device is booting up. If successful, this allows the adversary to modify memory, subvert authentication mechanisms, spoof identities and content, and extract data and memory from the target device. Currently 7 major vulnerabilities exist within Thunderbolt protocol with 9 attack vectors as noted in the Execution Flow.
CAPEC-701: Browser in the Middle (BiTM)
An adversary exploits the inherent functionalities of a web browser, in order to establish an unnoticed remote desktop connection in the victim's browser to the adversary's system. The adversary must deploy a web client with a remote desktop session that the victim can access.