CWE-284

Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

CVE-2025-26606 (GCVE-0-2025-26606)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:37 – Updated: 2025-02-19 16:43
VLAI
Title
SQL Injection endpoint 'informacao_adicional.php' parameter 'id_descricao' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `informacao_adicional.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.13
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26606",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T16:43:28.088025Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T16:43:38.093Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `informacao_adicional.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:37:53.943Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-rxjr-cw9q-cwwg",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-rxjr-cw9q-cwwg"
        }
      ],
      "source": {
        "advisory": "GHSA-rxjr-cw9q-cwwg",
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection endpoint \u0027informacao_adicional.php\u0027 parameter \u0027id_descricao\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26606",
    "datePublished": "2025-02-18T20:37:53.943Z",
    "dateReserved": "2025-02-12T14:51:02.717Z",
    "dateUpdated": "2025-02-19T16:43:38.093Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26607 (GCVE-0-2025-26607)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:37 – Updated: 2025-02-19 16:45
VLAI
Title
SQL Injection endpoint 'documento_excluir.php' parameter 'id_funcionario' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `documento_excluir.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.13
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26607",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T16:45:15.721668Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T16:45:24.942Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `documento_excluir.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:37:23.064Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-g6wj-3vm2-c59m",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-g6wj-3vm2-c59m"
        }
      ],
      "source": {
        "advisory": "GHSA-g6wj-3vm2-c59m",
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection endpoint \u0027documento_excluir.php\u0027 parameter \u0027id_funcionario\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26607",
    "datePublished": "2025-02-18T20:37:23.064Z",
    "dateReserved": "2025-02-12T14:51:02.717Z",
    "dateUpdated": "2025-02-19T16:45:24.942Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26608 (GCVE-0-2025-26608)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:36 – Updated: 2025-02-18 21:21
VLAI
Title
SQL Injection endpoint 'dependente_docdependente.php' parameter 'id_dependente', 'id_doc' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `dependente_docdependente.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.13
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26608",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T21:21:06.961030Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T21:21:19.349Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `dependente_docdependente.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:36:50.324Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-65h2-7484-2pww",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-65h2-7484-2pww"
        }
      ],
      "source": {
        "advisory": "GHSA-65h2-7484-2pww",
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection endpoint \u0027dependente_docdependente.php\u0027 parameter \u0027id_dependente\u0027, \u0027id_doc\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26608",
    "datePublished": "2025-02-18T20:36:50.324Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-18T21:21:19.349Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26609 (GCVE-0-2025-26609)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:36 – Updated: 2025-02-18 21:22
VLAI
Title
SQL Injection endpoint 'familiar_docfamiliar.php' parameter 'id_dependente', 'id_doc' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `familiar_docfamiliar.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.13
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26609",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T21:22:26.895514Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T21:22:58.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `familiar_docfamiliar.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:36:13.177Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-h7jx-ggv8-v2rh",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-h7jx-ggv8-v2rh"
        }
      ],
      "source": {
        "advisory": "GHSA-h7jx-ggv8-v2rh",
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection endpoint \u0027familiar_docfamiliar.php\u0027 parameter \u0027id_dependente\u0027, \u0027id_doc\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26609",
    "datePublished": "2025-02-18T20:36:13.177Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-18T21:22:58.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26611 (GCVE-0-2025-26611)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:34 – Updated: 2025-02-18 21:31
VLAI
Title
SQL Injection endpoint 'remover_produto.php' parameter 'id_produto' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `remover_produto.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.13
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26611",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T21:31:34.205598Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T21:31:49.532Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `remover_produto.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.13 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:34:58.710Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-q273-4vcj-qqp4",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-q273-4vcj-qqp4"
        }
      ],
      "source": {
        "advisory": "GHSA-q273-4vcj-qqp4",
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection endpoint \u0027remover_produto.php\u0027 parameter \u0027id_produto\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26611",
    "datePublished": "2025-02-18T20:34:58.710Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-18T21:31:49.532Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26613 (GCVE-0-2025-26613)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:33 – Updated: 2025-02-18 21:36
VLAI
Title
OS Command Injection endpoint 'gerenciar_backup.php' parameter 'file' (RCE) in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. An OS Command Injection vulnerability was discovered in the WeGIA application, `gerenciar_backup.php` endpoint. This vulnerability could allow an attacker to execute arbitrary code remotely. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.14
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26613",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T21:36:00.396209Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T21:36:06.208Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. An OS Command Injection vulnerability was discovered in the WeGIA application, `gerenciar_backup.php` endpoint. This vulnerability could allow an attacker to execute arbitrary code remotely. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:33:44.859Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-g3w6-m6w8-p6r2",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-g3w6-m6w8-p6r2"
        }
      ],
      "source": {
        "advisory": "GHSA-g3w6-m6w8-p6r2",
        "discovery": "UNKNOWN"
      },
      "title": "OS Command Injection endpoint \u0027gerenciar_backup.php\u0027 parameter \u0027file\u0027 (RCE) in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26613",
    "datePublished": "2025-02-18T20:33:44.859Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-18T21:36:06.208Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26615 (GCVE-0-2025-26615)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:32 – Updated: 2025-02-19 15:32
VLAI
Title
Path Traversal endpoint 'examples.php' parameter 'src' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A Path Traversal vulnerability was discovered in the WeGIA application, `examples.php` endpoint. This vulnerability could allow an attacker to gain unauthorized access to sensitive information stored in `config.php`. `config.php` contains information that could allow direct access to the database. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.14
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26615",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T15:31:52.622711Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T15:32:04.703Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A Path Traversal vulnerability was discovered in the WeGIA application, `examples.php` endpoint. This vulnerability could allow an attacker to gain unauthorized access to sensitive information stored in `config.php`. `config.php` contains information that could allow direct access to the database. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:32:10.899Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-p5wx-pv8j-f96h",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-p5wx-pv8j-f96h"
        }
      ],
      "source": {
        "advisory": "GHSA-p5wx-pv8j-f96h",
        "discovery": "UNKNOWN"
      },
      "title": "Path Traversal endpoint \u0027examples.php\u0027 parameter \u0027src\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26615",
    "datePublished": "2025-02-18T20:32:10.899Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-19T15:32:04.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26616 (GCVE-0-2025-26616)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:30 – Updated: 2025-02-19 15:36
VLAI
Title
Path Traversal endpoint 'exportar_dump.php' parameter 'file' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A Path Traversal vulnerability was discovered in the WeGIA application, `exportar_dump.php` endpoint. This vulnerability could allow an attacker to gain unauthorized access to sensitive information stored in `config.php`. `config.php` contains information that could allow direct access to the database. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.14
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26616",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T15:36:06.949118Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T15:36:19.521Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A Path Traversal vulnerability was discovered in the WeGIA application, `exportar_dump.php` endpoint. This vulnerability could allow an attacker to gain unauthorized access to sensitive information stored in `config.php`. `config.php` contains information that could allow direct access to the database. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:30:01.253Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-xxqg-p22h-3f32",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-xxqg-p22h-3f32"
        }
      ],
      "source": {
        "advisory": "GHSA-xxqg-p22h-3f32",
        "discovery": "UNKNOWN"
      },
      "title": "Path Traversal endpoint \u0027exportar_dump.php\u0027 parameter \u0027file\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26616",
    "datePublished": "2025-02-18T20:30:01.253Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-19T15:36:19.521Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26617 (GCVE-0-2025-26617)

Vulnerability from cvelistv5 – Published: 2025-02-18 20:29 – Updated: 2025-02-19 15:47
VLAI
Title
SQL Injection endpoint 'historico_paciente.php' parameter 'id_fichamedica' in WeGIA
Summary
WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `historico_paciente.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
LabRedesCefetRJ WeGIA Affected: < 3.2.14
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26617",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T15:39:28.906645Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T15:47:34.593Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WeGIA",
          "vendor": "LabRedesCefetRJ",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "WeGIA is an open source Web Manager for Institutions with a focus on Portuguese language users. A SQL Injection vulnerability was discovered in the WeGIA application, `historico_paciente.php` endpoint. This vulnerability could allow an attacker to execute arbitrary SQL queries, allowing unauthorized access to sensitive information. This issue has been addressed in version 3.2.14 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T20:29:17.367Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-f654-c5r5-jx77",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-f654-c5r5-jx77"
        }
      ],
      "source": {
        "advisory": "GHSA-f654-c5r5-jx77",
        "discovery": "UNKNOWN"
      },
      "title": "SQL Injection endpoint \u0027historico_paciente.php\u0027 parameter \u0027id_fichamedica\u0027 in WeGIA"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-26617",
    "datePublished": "2025-02-18T20:29:17.367Z",
    "dateReserved": "2025-02-12T14:51:02.718Z",
    "dateUpdated": "2025-02-19T15:47:34.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26645 (GCVE-0-2025-26645)

Vulnerability from cvelistv5 – Published: 2025-03-11 16:59 – Updated: 2026-02-13 19:39
VLAI
Title
Remote Desktop Client Remote Code Execution Vulnerability
Summary
Relative path traversal in Remote Desktop Client allows an unauthorized attacker to execute code over a network.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-23 - Relative Path Traversal
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Microsoft Remote Desktop client for Windows Desktop Affected: 1.2.0.0 , < 1.2.6017.0 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1507 Affected: 10.0.10240.0 , < 10.0.10240.20947 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1607 Affected: 10.0.14393.0 , < 10.0.14393.7876 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1809 Affected: 10.0.17763.0 , < 10.0.17763.7009 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 21H2 Affected: 10.0.19044.0 , < 10.0.19044.5608 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 22H2 Affected: 10.0.19045.0 , < 10.0.19045.5608 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H2 Affected: 10.0.22621.0 , < 10.0.22621.5039 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H3 Affected: 10.0.22631.0 , < 10.0.22631.5039 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 23H2 Affected: 10.0.22631.0 , < 10.0.22631.5039 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 24H2 Affected: 10.0.26100.0 , < 10.0.26100.3476 (custom)
Create a notification for this product.
Microsoft Windows App Client for Windows Desktop Affected: 1.00 , < 2.0.365.0 (custom)
Create a notification for this product.
Microsoft Windows Server 2008 R2 Service Pack 1 Affected: 6.1.7601.0 , < 6.1.7601.27618 (custom)
Create a notification for this product.
Microsoft Windows Server 2008 R2 Service Pack 1 (Server Core installation) Affected: 6.1.7601.0 , < 6.1.7601.27618 (custom)
Create a notification for this product.
Microsoft Windows Server 2008 Service Pack 2 Affected: 6.0.6003.0 , < 6.0.6003.23168 (custom)
Create a notification for this product.
Microsoft Windows Server 2008 Service Pack 2 (Server Core installation) Affected: 6.0.6003.0 , < 6.0.6003.23168 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 Affected: 6.2.9200.0 , < 6.2.9200.25368 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 (Server Core installation) Affected: 6.2.9200.0 , < 6.2.9200.25368 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 Affected: 6.3.9600.0 , < 6.3.9600.22470 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 (Server Core installation) Affected: 6.3.9600.0 , < 6.3.9600.22470 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 Affected: 10.0.14393.0 , < 10.0.14393.7876 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 (Server Core installation) Affected: 10.0.14393.0 , < 10.0.14393.7876 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 Affected: 10.0.17763.0 , < 10.0.17763.7009 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 (Server Core installation) Affected: 10.0.17763.0 , < 10.0.17763.7009 (custom)
Create a notification for this product.
Microsoft Windows Server 2022 Affected: 10.0.20348.0 , < 10.0.20348.3328 (custom)
Create a notification for this product.
Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) Affected: 10.0.25398.0 , < 10.0.25398.1486 (custom)
Create a notification for this product.
Microsoft Windows Server 2025 Affected: 10.0.26100.0 , < 10.0.26100.3476 (custom)
Create a notification for this product.
Microsoft Windows Server 2025 (Server Core installation) Affected: 10.0.26100.0 , < 10.0.26100.3476 (custom)
Create a notification for this product.
Date Public
2025-03-11 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26645",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T17:49:53.246485Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T17:52:15.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Remote Desktop client for Windows Desktop",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "1.2.6017.0",
              "status": "affected",
              "version": "1.2.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1507",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.10240.20947",
              "status": "affected",
              "version": "10.0.10240.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1607",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.7876",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7009",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19044.5608",
              "status": "affected",
              "version": "10.0.19044.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19045.5608",
              "status": "affected",
              "version": "10.0.19045.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22621.5039",
              "status": "affected",
              "version": "10.0.22621.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 22H3",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.5039",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 23H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.5039",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 24H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.3476",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Windows App Client for Windows Desktop",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "2.0.365.0",
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2008 R2 Service Pack 1",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.1.7601.27618",
              "status": "affected",
              "version": "6.1.7601.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2008 R2 Service Pack 1 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.1.7601.27618",
              "status": "affected",
              "version": "6.1.7601.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows Server 2008 Service Pack 2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.0.6003.23168",
              "status": "affected",
              "version": "6.0.6003.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows Server 2008 Service Pack 2 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.0.6003.23168",
              "status": "affected",
              "version": "6.0.6003.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.25368",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.25368",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.22470",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.22470",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.7876",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.7876",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7009",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7009",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.20348.3328",
              "status": "affected",
              "version": "10.0.20348.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.25398.1486",
              "status": "affected",
              "version": "10.0.25398.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2025",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.3476",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2025 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.3476",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:windows_app_client_for_windows_desktop:*:*:*:*:*:windows:*:*",
                  "versionEndExcluding": "2.0.365.0",
                  "versionStartIncluding": "1.00",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.17763.7009",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.7009",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.7009",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:remote_desktop:*:*:*:*:*:windows:*:*",
                  "versionEndExcluding": "1.2.6017.0",
                  "versionStartIncluding": "1.2.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.20348.3328",
                  "versionStartIncluding": "10.0.20348.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.19044.5608",
                  "versionStartIncluding": "10.0.19044.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22621.5039",
                  "versionStartIncluding": "10.0.22621.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.19045.5608",
                  "versionStartIncluding": "10.0.19045.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.26100.3476",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22631.5039",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22631.5039",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.25398.1486",
                  "versionStartIncluding": "10.0.25398.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_24H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.26100.3476",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.26100.3476",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.10240.20947",
                  "versionStartIncluding": "10.0.10240.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.14393.7876",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.7876",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.7876",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2008_sp2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.0.6003.23168",
                  "versionStartIncluding": "6.0.6003.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2008_sp2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.0.6003.23168",
                  "versionStartIncluding": "6.0.6003.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2008_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.1.7601.27618",
                  "versionStartIncluding": "6.1.7601.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2008_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.1.7601.27618",
                  "versionStartIncluding": "6.1.7601.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.25368",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.25368",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.22470",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.22470",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2025-03-11T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Relative path traversal in Remote Desktop Client allows an unauthorized attacker to execute code over a network."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en-US",
              "type": "CWE"
            },
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-13T19:39:10.159Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Remote Desktop Client Remote Code Execution Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-26645"
        }
      ],
      "title": "Remote Desktop Client Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2025-26645",
    "datePublished": "2025-03-11T16:59:25.729Z",
    "dateReserved": "2025-02-12T19:23:29.269Z",
    "dateUpdated": "2026-02-13T19:39:10.159Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation ID: MIT-1

Phases: Architecture and Design, Operation

Description:

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
Mitigation ID: MIT-46

Phase: Architecture and Design

Strategy: Separation of Privilege

Description:

  • Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-19: Embedding Scripts within Scripts

An adversary leverages the capability to execute their own script by embedding it within other scripts that the target software is likely to execute due to programs' vulnerabilities that are brought on by allowing remote hosts to execute scripts.

CAPEC-441: Malicious Logic Insertion

An adversary installs or adds malicious logic (also known as malware) into a seemingly benign component of a fielded system. This logic is often hidden from the user of the system and works behind the scenes to achieve negative impacts. With the proliferation of mass digital storage and inexpensive multimedia devices, Bluetooth and 802.11 support, new attack vectors for spreading malware are emerging for things we once thought of as innocuous greeting cards, picture frames, or digital projectors. This pattern of attack focuses on systems already fielded and used in operation as opposed to systems and their components that are still under development and part of the supply chain.

CAPEC-478: Modification of Windows Service Configuration

An adversary exploits a weakness in access control to modify the execution parameters of a Windows service. The goal of this attack is to execute a malicious binary in place of an existing service.

CAPEC-479: Malicious Root Certificate

An adversary exploits a weakness in authorization and installs a new root certificate on a compromised system. Certificates are commonly used for establishing secure TLS/SSL communications within a web browser. When a user attempts to browse a website that presents a certificate that is not trusted an error message will be displayed to warn the user of the security risk. Depending on the security settings, the browser may not allow the user to establish a connection to the website. Adversaries have used this technique to avoid security warnings prompting users when compromised systems connect over HTTPS to adversary controlled web servers that spoof legitimate websites in order to collect login credentials.

CAPEC-502: Intent Spoof

An adversary, through a previously installed malicious application, issues an intent directed toward a specific trusted application's component in an attempt to achieve a variety of different objectives including modification of data, information disclosure, and data injection. Components that have been unintentionally exported and made public are subject to this type of an attack. If the component trusts the intent's action without verififcation, then the target application performs the functionality at the adversary's request, helping the adversary achieve the desired negative technical impact.

CAPEC-503: WebView Exposure

An adversary, through a malicious web page, accesses application specific functionality by leveraging interfaces registered through WebView's addJavascriptInterface API. Once an interface is registered to WebView through addJavascriptInterface, it becomes global and all pages loaded in the WebView can call this interface.

CAPEC-536: Data Injected During Configuration

An attacker with access to data files and processes on a victim's system injects malicious data into critical operational data during configuration or recalibration, causing the victim's system to perform in a suboptimal manner that benefits the adversary.

CAPEC-546: Incomplete Data Deletion in a Multi-Tenant Environment

An adversary obtains unauthorized information due to insecure or incomplete data deletion in a multi-tenant environment. If a cloud provider fails to completely delete storage and data from former cloud tenants' systems/resources, once these resources are allocated to new, potentially malicious tenants, the latter can probe the provided resources for sensitive information still there.

CAPEC-550: Install New Service

When an operating system starts, it also starts programs called services or daemons. Adversaries may install a new service which will be executed at startup (on a Windows system, by modifying the registry). The service name may be disguised by using a name from a related operating system or benign software. Services are usually run with elevated privileges.

CAPEC-551: Modify Existing Service

When an operating system starts, it also starts programs called services or daemons. Modifying existing services may break existing services or may enable services that are disabled/not commonly used.

CAPEC-552: Install Rootkit

An adversary exploits a weakness in authentication to install malware that alters the functionality and information provide by targeted operating system API calls. Often referred to as rootkits, it is often used to hide the presence of programs, files, network connections, services, drivers, and other system components.

CAPEC-556: Replace File Extension Handlers

When a file is opened, its file handler is checked to determine which program opens the file. File handlers are configuration properties of many operating systems. Applications can modify the file handler for a given file extension to call an arbitrary program when a file with the given extension is opened.

CAPEC-558: Replace Trusted Executable

An adversary exploits weaknesses in privilege management or access control to replace a trusted executable with a malicious version and enable the execution of malware when that trusted executable is called.

CAPEC-562: Modify Shared File

An adversary manipulates the files in a shared location by adding malicious programs, scripts, or exploit code to valid content. Once a user opens the shared content, the tainted content is executed.

CAPEC-563: Add Malicious File to Shared Webroot

An adversaries may add malicious content to a website through the open file share and then browse to that content with a web browser to cause the server to execute the content. The malicious content will typically run under the context and permissions of the web server process, often resulting in local system or administrative privileges depending on how the web server is configured.

CAPEC-564: Run Software at Logon

Operating system allows logon scripts to be run whenever a specific user or users logon to a system. If adversaries can access these scripts, they may insert additional code into the logon script. This code can allow them to maintain persistence or move laterally within an enclave because it is executed every time the affected user or users logon to a computer. Modifying logon scripts can effectively bypass workstation and enclave firewalls. Depending on the access configuration of the logon scripts, either local credentials or a remote administrative account may be necessary.

CAPEC-578: Disable Security Software

An adversary exploits a weakness in access control to disable security tools so that detection does not occur. This can take the form of killing processes, deleting registry keys so that tools do not start at run time, deleting log files, or other methods.

Back to CWE stats page