CWE-319

Cleartext Transmission of Sensitive Information

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

CVE-2026-22544 (GCVE-0-2026-22544)

Vulnerability from cvelistv5 – Published: 2026-01-07 16:23 – Updated: 2026-01-07 16:38 X_Mqtt X_Charger X_Ics
VLAI
Title
EXCHANGE OF CREDENTIALS IN CLEAR TEXT
Summary
An attacker with a network connection could detect credentials in clear text.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Credits
Aarón Flecha Menéndez Iván Alonso Álvarez Víctor Bello Cuevas
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-22544",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-07T16:38:01.414730Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-07T16:38:40.422Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "QC 60/90/120",
          "vendor": "EFACEC",
          "versions": [
            {
              "status": "affected",
              "version": "8"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aar\u00f3n Flecha Men\u00e9ndez"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Iv\u00e1n Alonso \u00c1lvarez"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "V\u00edctor Bello Cuevas"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An attacker with a network connection could detect credentials in clear text."
            }
          ],
          "value": "An attacker with a network connection could detect credentials in clear text."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117 Interception"
            }
          ]
        },
        {
          "capecId": "CAPEC-94",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-94: Man in the Middle Attack"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-07T16:23:08.550Z",
        "orgId": "50b5080a-775f-442e-83b5-926b5ca517b6",
        "shortName": "S21sec"
      },
      "references": [
        {
          "url": "https://cds.thalesgroup.com/en"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "x_MQTT",
        "x_Charger",
        "x_ICS"
      ],
      "title": "EXCHANGE OF CREDENTIALS IN CLEAR TEXT",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "50b5080a-775f-442e-83b5-926b5ca517b6",
    "assignerShortName": "S21sec",
    "cveId": "CVE-2026-22544",
    "datePublished": "2026-01-07T16:23:08.550Z",
    "dateReserved": "2026-01-07T14:01:04.829Z",
    "dateUpdated": "2026-01-07T16:38:40.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-23564 (GCVE-0-2026-23564)

Vulnerability from cvelistv5 – Published: 2026-01-29 08:43 – Updated: 2026-01-29 16:53
VLAI
Title
Transmission of Unencrypted Data in Content Distribution Service
Summary
A vulnerability in TeamViewer DEX Client (former 1E Client) - Content Distribution Service (NomadBranch.exe) prior version 26.1 for Windows allows an attacker on the adjacent network to cause normally encrypted UDP traffic to be sent in cleartext. This can result in disclosure of sensitive information.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
TV
Impacted products
Vendor Product Version
TeamViewer DEX Affected: 0 , < 26.1 (custom)
Create a notification for this product.
Credits
Threat Hunt Team of Bank of America
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-23564",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-29T15:57:06.915459Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-29T16:53:10.746Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Content Distribution Service",
            "NomadBranch.exe"
          ],
          "platforms": [
            "Windows"
          ],
          "product": "DEX",
          "vendor": "TeamViewer",
          "versions": [
            {
              "lessThan": "26.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Threat Hunt Team of Bank of America"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability in TeamViewer DEX Client (former 1E Client) - Content Distribution Service (NomadBranch.exe) prior version 26.1 for Windows allows an attacker on the adjacent network to cause normally encrypted UDP traffic to be sent in cleartext. This can result in disclosure of sensitive information.\u003c/span\u003e"
            }
          ],
          "value": "A vulnerability in TeamViewer DEX Client (former 1E Client) - Content Distribution Service (NomadBranch.exe) prior version 26.1 for Windows allows an attacker on the adjacent network to cause normally encrypted UDP traffic to be sent in cleartext. This can result in disclosure of sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-220",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-220 Client-Server Protocol Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-29T08:43:43.799Z",
        "orgId": "13430f76-86eb-43b2-a71c-82c956ef31b6",
        "shortName": "TV"
      },
      "references": [
        {
          "url": "https://www.teamviewer.com/en/resources/trust-center/security-bulletins/tv-2026-1001/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update the TeamViewer DEX Client (1E Client) to the latest available version."
            }
          ],
          "value": "Update the TeamViewer DEX Client (1E Client) to the latest available version."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Transmission of Unencrypted Data in Content Distribution Service",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "13430f76-86eb-43b2-a71c-82c956ef31b6",
    "assignerShortName": "TV",
    "cveId": "CVE-2026-23564",
    "datePublished": "2026-01-29T08:43:43.799Z",
    "dateReserved": "2026-01-14T13:54:40.322Z",
    "dateUpdated": "2026-01-29T16:53:10.746Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-23661 (GCVE-0-2026-23661)

Vulnerability from cvelistv5 – Published: 2026-03-10 17:05 – Updated: 2026-04-14 16:36
VLAI
Title
Azure IoT Explorer Information Disclosure Vulnerability
Summary
Cleartext transmission of sensitive information in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Microsoft Azure IoT Explorer Affected: 1.0.0 , < 0.15.13 (custom)
Create a notification for this product.
Date Public
2026-03-10 14:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-23661",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T18:40:46.463784Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T18:45:16.120Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Azure IoT Explorer",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "0.15.13",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:azure_iot_explorer:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "0.15.13",
                  "versionStartIncluding": "1.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2026-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Cleartext transmission of sensitive information in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T16:36:34.353Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Azure IoT Explorer Information Disclosure Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-23661"
        }
      ],
      "title": "Azure IoT Explorer Information Disclosure Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2026-23661",
    "datePublished": "2026-03-10T17:05:15.813Z",
    "dateReserved": "2026-01-14T16:59:33.463Z",
    "dateUpdated": "2026-04-14T16:36:34.353Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-23662 (GCVE-0-2026-23662)

Vulnerability from cvelistv5 – Published: 2026-03-10 17:05 – Updated: 2026-04-14 16:36
VLAI
Title
Azure IoT Explorer Information Disclosure Vulnerability
Summary
Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Microsoft Azure IoT Explorer Affected: 1.0.0 , < 0.15.13 (custom)
Create a notification for this product.
Date Public
2026-03-10 14:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-23662",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T19:53:37.580696Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T19:53:45.696Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Azure IoT Explorer",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "0.15.13",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:azure_iot_explorer:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "0.15.13",
                  "versionStartIncluding": "1.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2026-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en-US",
              "type": "CWE"
            },
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T16:36:34.918Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Azure IoT Explorer Information Disclosure Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-23662"
        }
      ],
      "title": "Azure IoT Explorer Information Disclosure Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2026-23662",
    "datePublished": "2026-03-10T17:05:16.330Z",
    "dateReserved": "2026-01-14T16:59:33.463Z",
    "dateUpdated": "2026-04-14T16:36:34.918Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-24060 (GCVE-0-2026-24060)

Vulnerability from cvelistv5 – Published: 2026-03-20 23:19 – Updated: 2026-03-23 15:55 Unsupported When Assigned
VLAI
Title
Automated Logic WebCTRL Premium Server Cleartext Transmission of Sensitive Information
Summary
Service information is not encrypted when transmitted as BACnet packets over the wire, and can be sniffed, intercepted, and modified by an attacker. Valuable information such as the File Start Position and File Data can be sniffed from network traffic using Wireshark's BACnet dissector filter. The proprietary format used by WebCTRL to receive updates from the PLC can also be sniffed and reverse engineered.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Automated Logic WebCTRL Premium Server Affected: 0 , < v8.5 (custom)
Create a notification for this product.
Credits
Jonathan Lee, Thuy D. Nguyen, and Neil C. Rowe of the Naval Postgraduate School reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-24060",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-23T14:49:21.420075Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-319",
                "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-23T15:55:53.047Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "WebCTRL Premium Server",
          "vendor": "Automated Logic",
          "versions": [
            {
              "lessThan": "v8.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jonathan Lee, Thuy D. Nguyen, and Neil C. Rowe of the Naval Postgraduate School reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Service information is not encrypted when transmitted as BACnet packets \nover the wire, and can be sniffed, intercepted, and modified by an \nattacker. Valuable information such as the File Start Position and File \nData can be sniffed from network traffic using Wireshark\u0027s BACnet \ndissector filter. The proprietary format used by WebCTRL to receive \nupdates from the PLC can also be sniffed and reverse engineered."
            }
          ],
          "value": "Service information is not encrypted when transmitted as BACnet packets \nover the wire, and can be sniffed, intercepted, and modified by an \nattacker. Valuable information such as the File Start Position and File \nData can be sniffed from network traffic using Wireshark\u0027s BACnet \ndissector filter. The proprietary format used by WebCTRL to receive \nupdates from the PLC can also be sniffed and reverse engineered."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-20T23:19:05.223Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.automatedlogic.com/en/company/security-commitment/"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-078-08.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Automated Logic notes that WebCTRL 7 is end of life and has been \nout of support since January 27, 2023. Users are advised to upgrade to \nthe latest version of the WebCTRL server application, which supports the\n more secure BACnet/SC."
            }
          ],
          "value": "Automated Logic notes that WebCTRL 7 is end of life and has been \nout of support since January 27, 2023. Users are advised to upgrade to \nthe latest version of the WebCTRL server application, which supports the\n more secure BACnet/SC."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "For users of supported versions of WebCTRL (WebCTRL 8.5 \ncumulative releases and later), Automated Logic provides secure \nconfiguration guidance for hardware and software deployments; BACnet \nSecure Connect (BACnet/SC) support, which introduces TLS encryption and \nmutual authentication; and published best practices for network \nsegmentation, access control, and secure protocol implementation. \nAdditional information is available at:\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.automatedlogic.com/en/company/security-commitment/\" title=\"(opens in a new window)\"\u003ehttps://www.automatedlogic.com/en/company/security-commitment/\u003c/a\u003e"
            }
          ],
          "value": "For users of supported versions of WebCTRL (WebCTRL 8.5 \ncumulative releases and later), Automated Logic provides secure \nconfiguration guidance for hardware and software deployments; BACnet \nSecure Connect (BACnet/SC) support, which introduces TLS encryption and \nmutual authentication; and published best practices for network \nsegmentation, access control, and secure protocol implementation. \nAdditional information is available at:\u00a0\n https://www.automatedlogic.com/en/company/security-commitment/"
        }
      ],
      "source": {
        "advisory": "ICSA-26-078-08",
        "discovery": "EXTERNAL"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "title": "Automated Logic WebCTRL Premium Server Cleartext Transmission of Sensitive Information",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-24060",
    "datePublished": "2026-03-20T23:19:05.223Z",
    "dateReserved": "2026-03-12T19:57:03.348Z",
    "dateUpdated": "2026-03-23T15:55:53.047Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-24212 (GCVE-0-2026-24212)

Vulnerability from cvelistv5 – Published: 2026-05-26 16:11 – Updated: 2026-05-26 19:22
VLAI
Summary
NVIDIA Isaac Launchable for Linux contains a vulnerability where sensitive information is transmitted in clear text. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, information disclosure, and data tampering.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
Impacted products
Vendor Product Version
NVIDIA Isaac Launchable Affected: 0 , < 1.2 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-24212",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-26T19:22:39.164960Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-26T19:22:48.670Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "Isaac Launchable",
          "vendor": "NVIDIA",
          "versions": [
            {
              "lessThan": "1.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": true,
              "type": "text/html",
              "value": "NVIDIA Isaac Launchable for Linux contains a vulnerability where sensitive information is transmitted in clear text. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, information disclosure, and data tampering."
            }
          ],
          "value": "NVIDIA Isaac Launchable for Linux contains a vulnerability where sensitive information is transmitted in clear text. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, information disclosure, and data tampering."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Code execution, escalation of privileges, denial of service, data tampering"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-26T18:38:59.026Z",
        "orgId": "9576f279-3576-44b5-a4af-b9a8644b2de6",
        "shortName": "nvidia"
      },
      "references": [
        {
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-24212"
        },
        {
          "url": "https://www.cve.org/CVERecord?id=CVE-2026-24212"
        },
        {
          "url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5830"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "NVIDIA PSIRT"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9576f279-3576-44b5-a4af-b9a8644b2de6",
    "assignerShortName": "nvidia",
    "cveId": "CVE-2026-24212",
    "datePublished": "2026-05-26T16:11:27.525Z",
    "dateReserved": "2026-01-21T19:09:35.634Z",
    "dateUpdated": "2026-05-26T19:22:48.670Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-24441 (GCVE-0-2026-24441)

Vulnerability from cvelistv5 – Published: 2026-02-03 19:14 – Updated: 2026-05-14 02:09
VLAI
Title
Tenda AC7 Transmits Admin Credentials Without HTTPS Protection
Summary
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Shenzhen Tenda Technology Co., Ltd. Tenda AC7 Affected: 0 , ≤ 03.03.03.01_cn (custom)
Create a notification for this product.
Credits
Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-24441",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-03T21:13:48.868333Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-03T21:13:56.007Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Tenda AC7",
          "vendor": "Shenzhen Tenda Technology Co., Ltd.",
          "versions": [
            {
              "lessThanOrEqual": "03.03.03.01_cn",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "03.03.03.01_cn",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material."
            }
          ],
          "value": "Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-14T02:09:40.338Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tendacn.com/product/AC7"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/tenda-ac7-transmits-admin-credentials-without-https-protection"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Tenda AC7 Transmits Admin Credentials Without HTTPS Protection",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2026-24441",
    "datePublished": "2026-02-03T19:14:41.224Z",
    "dateReserved": "2026-01-22T20:23:19.804Z",
    "dateUpdated": "2026-05-14T02:09:40.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-24455 (GCVE-0-2026-24455)

Vulnerability from cvelistv5 – Published: 2026-02-20 16:00 – Updated: 2026-02-20 20:01 Unsupported When Assigned
VLAI
Title
Jinan USR IOT Technology Limited (PUSR) USR-W610 Cleartext Transmission of Sensitive Information
Summary
The embedded web interface of the device does not support HTTPS/TLS for authentication and uses HTTP Basic Authentication. Traffic is encoded but not encrypted, exposing user credentials to passive interception by attackers on the same network.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Jinan USR IOT Technology Limited (PUSR) USR-W610 Affected: 0 , ≤ 3.1.1.0 (custom)
Create a notification for this product.
Credits
Abhishek Pandey of Payatu Security Consulting reported this to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-24455",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-20T20:00:37.730069Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-20T20:01:11.347Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "USR-W610",
          "vendor": "Jinan USR IOT Technology Limited (PUSR)",
          "versions": [
            {
              "lessThanOrEqual": "3.1.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey of Payatu Security Consulting reported this to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The embedded web interface of the device does not support HTTPS/TLS for \nauthentication and uses HTTP Basic Authentication. Traffic is encoded \nbut not encrypted, exposing user credentials to passive interception by \nattackers on the same network."
            }
          ],
          "value": "The embedded web interface of the device does not support HTTPS/TLS for \nauthentication and uses HTTP Basic Authentication. Traffic is encoded \nbut not encrypted, exposing user credentials to passive interception by \nattackers on the same network."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-20T16:00:42.396Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-050-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-050-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-050-03",
        "discovery": "EXTERNAL"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "title": "Jinan USR IOT Technology Limited (PUSR) USR-W610 Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Jinan USR IOT Technology Limited (PUSR) has stated that the product is \nend-of-life, and there are no plans to patch. Users of PUSR USR-W610 \ndevices are encouraged to \u003ca target=\"_blank\" rel=\"nofollow\"\u003econtact PUSR\u003c/a\u003e and keep their systems up to date.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Jinan USR IOT Technology Limited (PUSR) has stated that the product is \nend-of-life, and there are no plans to patch. Users of PUSR USR-W610 \ndevices are encouraged to contact PUSR and keep their systems up to date."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-24455",
    "datePublished": "2026-02-20T16:00:42.396Z",
    "dateReserved": "2026-02-10T15:52:10.245Z",
    "dateUpdated": "2026-02-20T20:01:11.347Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2539 (GCVE-0-2026-2539)

Vulnerability from cvelistv5 – Published: 2026-02-15 10:58 – Updated: 2026-02-17 17:07
VLAI
Title
Micca KE700 Cleartext transmission of key fob ID
Summary
The RF communication protocol in the Micca KE700 car alarm system does not encrypt its data frames. An attacker with a radio interception tool (e.g., SDR) can capture the random number and counters transmitted in cleartext, which is sensitive information required for authentication.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Credits
Danilo Erazo
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2539",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-17T16:42:19.132639Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-17T17:07:03.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "modules": [
            "RF Communication Module"
          ],
          "platforms": [
            "Hardware"
          ],
          "product": "Car Alarm System KE700",
          "vendor": "Micca Auto Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "KE700"
            },
            {
              "status": "unknown",
              "version": "KE700+"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Danilo Erazo"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe RF communication protocol in the Micca KE700 car alarm system does not encrypt its data frames. An attacker with a radio interception tool (e.g., SDR) can capture the random number and counters\u0026nbsp;transmitted in cleartext, which is sensitive information required for authentication.\u003c/p\u003e"
            }
          ],
          "value": "The RF communication protocol in the Micca KE700 car alarm system does not encrypt its data frames. An attacker with a radio interception tool (e.g., SDR) can capture the random number and counters\u00a0transmitted in cleartext, which is sensitive information required for authentication."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N/E:P/AU:N/V:D/RE:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "HIGH"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-15T10:58:38.397Z",
        "orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
        "shortName": "ASRG"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://asrg.io/security-advisories/cve-2026-2539-micca-ke700-cleartext-transmission-of-key-fob-id/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cul\u003e\u003cli\u003e\u003cb\u003eImplement encryption\u003c/b\u003e: The entire transmission frame must be encrypted using a standard, proven symmetric algorithm (e.g., AES-128).\u0026nbsp;\u003c/li\u003e\n\u003cli\u003e\u003cb\u003eAuthenticate the frame\u003c/b\u003e: The encrypted payload should include a Message Authentication Code (MAC) to prevent tampering or spoofing.\u003c/li\u003e\n\u003c/ul\u003e"
            }
          ],
          "value": "*  Implement encryption: The entire transmission frame must be encrypted using a standard, proven symmetric algorithm (e.g., AES-128).\u00a0\n\n  *  Authenticate the frame: The encrypted payload should include a Message Authentication Code (MAC) to prevent tampering or spoofing."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Micca KE700 Cleartext transmission of key fob ID",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
    "assignerShortName": "ASRG",
    "cveId": "CVE-2026-2539",
    "datePublished": "2026-02-15T10:58:38.397Z",
    "dateReserved": "2026-02-15T10:49:21.601Z",
    "dateUpdated": "2026-02-17T17:07:03.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-25599 (GCVE-0-2026-25599)

Vulnerability from cvelistv5 – Published: 2026-06-01 09:17 – Updated: 2026-06-01 13:01 Unsupported When Assigned
VLAI
Title
Missing authentication and clear‑text data transmission affecting Orca heat pumps
Summary
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
  • CWE-306 - Missing authentication for critical function
  • CWE-319 - Cleartext transmission of sensitive information
Assigner
References
Impacted products
Credits
Tom Kern, NIL d.o.o.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-25599",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-01T13:01:12.777564Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-01T13:01:21.955Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Orca heat pump",
          "vendor": "Orca Energy",
          "versions": [
            {
              "lessThan": "2.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Orca user portal",
          "vendor": "Orca Energy",
          "versions": [
            {
              "lessThan": "1.19",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Tom Kern, NIL d.o.o."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing authentication and clear\u2011text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump\u2019s web control interface.\u0026nbsp;Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal."
            }
          ],
          "value": "Missing authentication and clear\u2011text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump\u2019s web control interface.\u00a0Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext transmission of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-01T09:17:51.060Z",
        "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "shortName": "ENISA"
      },
      "references": [
        {
          "url": "https://www.cert.si/en/cve-2026-25599/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "title": "Missing authentication and clear\u2011text data transmission affecting Orca heat pumps",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
    "assignerShortName": "ENISA",
    "cveId": "CVE-2026-25599",
    "datePublished": "2026-06-01T09:17:51.060Z",
    "dateReserved": "2026-02-03T07:24:49.547Z",
    "dateUpdated": "2026-06-01T13:01:21.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation

Phase: Architecture and Design

Description:

  • Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
Mitigation

Phase: Implementation

Description:

  • When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
Mitigation

Phase: Implementation

Description:

  • When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.
Mitigation

Phase: Testing

Description:

  • Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.
Mitigation

Phase: Operation

Description:

  • Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.
CAPEC-102: Session Sidejacking

Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.

CAPEC-117: Interception

An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.

CAPEC-383: Harvesting Information via API Event Monitoring

An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.

CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content

An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.

CAPEC-65: Sniff Application Code

An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.

Back to CWE stats page