CWE-532

Insertion of Sensitive Information into Log File

The product writes sensitive information to a log file.

CVE-2022-4311 (GCVE-0-2022-4311)

Vulnerability from cvelistv5 – Published: 2022-12-12 17:08 – Updated: 2025-04-14 17:59
VLAI
Summary
An insertion of sensitive information into log file vulnerability exists in PcVue versions 15 through 15.2.2. This could allow a user with access to the log files to discover connection strings of data sources configured for the DbConnect, which could include credentials. Successful exploitation of this vulnerability could allow other users unauthorized access to the underlying data sources.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
ARC Informatique PcVue Affected: 15 , ≤ 15.2.2 (custom)
Create a notification for this product.
Credits
ARC Informatique
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:34:50.134Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.pcvuesolutions.com/support/index.php/en/security-bulletin/1165-security-bulletin-2022-6"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-4311",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T14:51:25.883186Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-14T17:59:59.779Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PcVue",
          "vendor": "ARC Informatique",
          "versions": [
            {
              "lessThanOrEqual": "15.2.2",
              "status": "affected",
              "version": "15",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "ARC Informatique"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAn insertion of sensitive information into log file vulnerability exists in PcVue versions 15 through 15.2.2. This\ncould allow a user with access to the log files to discover connection strings of data sources configured for the\nDbConnect, which could include credentials. Successful exploitation of this vulnerability could allow other users\nunauthorized access to the underlying data sources.\n\n"
            }
          ],
          "value": "\nAn insertion of sensitive information into log file vulnerability exists in PcVue versions 15 through 15.2.2. This\ncould allow a user with access to the log files to discover connection strings of data sources configured for the\nDbConnect, which could include credentials. Successful exploitation of this vulnerability could allow other users\nunauthorized access to the underlying data sources.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T17:08:30.847Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.pcvuesolutions.com/support/index.php/en/security-bulletin/1165-security-bulletin-2022-6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-4311",
    "datePublished": "2022-12-12T17:08:30.847Z",
    "dateReserved": "2022-12-06T19:08:45.932Z",
    "dateUpdated": "2025-04-14T17:59:59.779Z",
    "requesterUserId": "4bacbe59-ded0-410b-af09-0c6f387b5ddc",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43772 (GCVE-0-2022-43772)

Vulnerability from cvelistv5 – Published: 2023-04-03 18:50 – Updated: 2025-02-11 14:29
VLAI
Title
Hitachi Vantara Pentaho Business Analytics Server - Insertion of Sensitive Information into Log File
Summary
Hitachi Vantara Pentaho Business Analytics Server versions before 9.4.0.0 and 9.3.0.1, including 8.3.x with the Big Data Plugin expose the username and password of clusters in clear text into system logs. 
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
Impacted products
Credits
Harry Withington, Aura Information Security
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.pentaho.com/hc/en-us/articles/14454594588045--Resolved-Hitachi-Vantara-Pentaho-Business-Analytics-Server-Insertion-of-Sensitive-Information-into-Log-File-Versions-before-9-4-0-0-and-9-3-0-1-including-8-3-x-Impacted-CVE-2022-43772-"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43772",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T14:29:06.035853Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T14:29:10.931Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Big Data Plugin"
          ],
          "product": "Pentaho Business Analytics Server",
          "vendor": "Hitachi Vantara ",
          "versions": [
            {
              "lessThan": "9.3.0.1",
              "status": "affected",
              "version": "1.0",
              "versionType": "maven"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Harry Withington, Aura Information Security"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHitachi Vantara Pentaho Business Analytics Server versions before 9.4.0.0 and 9.3.0.1, including 8.3.x with the Big Data Plugin expose the username and password of clusters in clear text into system logs.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nHitachi Vantara Pentaho Business Analytics Server versions before 9.4.0.0 and 9.3.0.1, including 8.3.x with the Big Data Plugin expose the username and password of clusters in clear text into system logs.\u00a0\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-03T18:50:58.827Z",
        "orgId": "dce6e192-ff49-4263-9134-f0beccb9bc13",
        "shortName": "HITVAN"
      },
      "references": [
        {
          "url": "https://support.pentaho.com/hc/en-us/articles/14454594588045--Resolved-Hitachi-Vantara-Pentaho-Business-Analytics-Server-Insertion-of-Sensitive-Information-into-Log-File-Versions-before-9-4-0-0-and-9-3-0-1-including-8-3-x-Impacted-CVE-2022-43772-"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Hitachi Vantara Pentaho Business Analytics Server - Insertion of Sensitive Information into Log File     ",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dce6e192-ff49-4263-9134-f0beccb9bc13",
    "assignerShortName": "HITVAN",
    "cveId": "CVE-2022-43772",
    "datePublished": "2023-04-03T18:50:58.827Z",
    "dateReserved": "2022-10-26T12:55:14.327Z",
    "dateUpdated": "2025-02-11T14:29:10.931Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43870 (GCVE-0-2022-43870)

Vulnerability from cvelistv5 – Published: 2023-02-22 17:26 – Updated: 2025-03-11 18:29
VLAI
Title
IBM Spectrum Virtualize information disclosure
Summary
IBM Spectrum Virtualize 8.3, 8.4, and 8.5 could disclose SNMPv3 server credentials to an authenticated user in log files. IBM X-Force ID: 239540.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
ibm
Impacted products
Vendor Product Version
IBM Spectrum Virtualize Affected: 8.3, 8.4, 8.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.869Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.ibm.com/support/pages/node/6858045"
          },
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/239540"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43870",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T18:28:59.121749Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T18:29:26.293Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Spectrum Virtualize",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "8.3, 8.4, 8.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IBM Spectrum Virtualize 8.3, 8.4, and 8.5 could disclose SNMPv3 server credentials to an authenticated user in log files.  IBM X-Force ID:  239540."
            }
          ],
          "value": "IBM Spectrum Virtualize 8.3, 8.4, and 8.5 could disclose SNMPv3 server credentials to an authenticated user in log files.  IBM X-Force ID:  239540."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-22T17:26:20.175Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.ibm.com/support/pages/node/6858045"
        },
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/239540"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IBM Spectrum Virtualize information disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2022-43870",
    "datePublished": "2023-02-22T17:26:20.175Z",
    "dateReserved": "2022-10-26T15:46:22.825Z",
    "dateUpdated": "2025-03-11T18:29:26.293Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43887 (GCVE-0-2022-43887)

Vulnerability from cvelistv5 – Published: 2022-12-19 20:27 – Updated: 2025-04-17 13:54
VLAI
Title
IBM Cognos Analytics information disclosure
Summary
IBM Cognos Analytics 11.1.7, 11.2.0, and 11.2.1 could be vulnerable to sensitive information exposure by passing API keys to log files. If these keys contain sensitive information, it could lead to further attacks. IBM X-Force ID: 240450.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
ibm
Impacted products
Vendor Product Version
IBM Cognos Analytics Affected: 11.1.7, 11.2.0, 11.2.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.582Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.ibm.com/support/pages/node/6841801"
          },
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/240450"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43887",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T13:54:25.711267Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T13:54:45.867Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Cognos Analytics",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "11.1.7, 11.2.0, 11.2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(204, 217, 226);\"\u003eIBM Cognos Analytics 11.1.7, 11.2.0, and 11.2.1 could be vulnerable to sensitive information exposure by passing API keys to log files. If these keys contain sensitive information, it could lead to further attacks. IBM X-Force ID: 240450.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nIBM Cognos Analytics 11.1.7, 11.2.0, and 11.2.1 could be vulnerable to sensitive information exposure by passing API keys to log files. If these keys contain sensitive information, it could lead to further attacks. IBM X-Force ID: 240450.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-19T20:27:09.027Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.ibm.com/support/pages/node/6841801"
        },
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/240450"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IBM Cognos Analytics information disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2022-43887",
    "datePublished": "2022-12-19T20:27:09.027Z",
    "dateReserved": "2022-10-26T15:46:22.832Z",
    "dateUpdated": "2025-04-17T13:54:45.867Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43923 (GCVE-0-2022-43923)

Vulnerability from cvelistv5 – Published: 2023-02-24 14:13 – Updated: 2025-03-11 15:41
VLAI
Summary
IBM Maximo Application Suite 8.8.0 and 8.9.0 stores potentially sensitive information that could be read by a local user. IBM X-Force ID: 241584.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
ibm
Impacted products
Vendor Product Version
IBM Maximo Application Suite Affected: 8.8.0, 8.9.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.871Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.ibm.com/support/pages/node/6957654"
          },
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/241584"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43923",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T15:40:52.376180Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T15:41:31.081Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Maximo Application Suite",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "8.8.0, 8.9.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IBM Maximo Application Suite 8.8.0 and 8.9.0 stores potentially sensitive information that could be read by a local user.  IBM X-Force ID:  241584."
            }
          ],
          "value": "IBM Maximo Application Suite 8.8.0 and 8.9.0 stores potentially sensitive information that could be read by a local user.  IBM X-Force ID:  241584."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-24T14:13:01.313Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.ibm.com/support/pages/node/6957654"
        },
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/241584"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2022-43923",
    "datePublished": "2023-02-24T14:13:01.313Z",
    "dateReserved": "2022-10-26T15:46:22.848Z",
    "dateUpdated": "2025-03-11T15:41:31.081Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43935 (GCVE-0-2022-43935)

Vulnerability from cvelistv5 – Published: 2024-11-21 01:51 – Updated: 2024-11-21 18:01
VLAI
Title
Switch passwords and authorization IDs are printed in the embedded MLS DB file
Summary
An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
Impacted products
Vendor Product Version
Brocade SANnav Unaffected: before Brocade SANnav 2.2.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43935",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:55:52.817993Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T18:01:26.445Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "unaffected",
              "version": "before Brocade SANnav 2.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T01:51:59.741Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21219"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Switch passwords and authorization IDs are printed in the embedded MLS DB file",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43935",
    "datePublished": "2024-11-21T01:51:59.741Z",
    "dateReserved": "2022-10-26T19:34:16.361Z",
    "dateUpdated": "2024-11-21T18:01:26.445Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43936 (GCVE-0-2022-43936)

Vulnerability from cvelistv5 – Published: 2024-11-21 03:04 – Updated: 2024-11-21 18:01
VLAI
Title
Brocade Fabric OS switch passwords when debugging is enabled
Summary
Brocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
Impacted products
Vendor Product Version
Brocade SANnav Affected: before Brocade SANnav 2.2.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43936",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:55:56.798864Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T18:01:26.562Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade SANnav 2.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBrocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled.\u003c/p\u003e"
            }
          ],
          "value": "Brocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T03:04:53.160Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21218"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade Fabric OS switch passwords when debugging is enabled",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43936",
    "datePublished": "2024-11-21T03:04:52.786Z",
    "dateReserved": "2022-10-26T19:34:16.362Z",
    "dateUpdated": "2024-11-21T18:01:26.562Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43937 (GCVE-0-2022-43937)

Vulnerability from cvelistv5 – Published: 2024-11-21 03:26 – Updated: 2024-11-21 17:54
VLAI
Title
Brocade SANnav Information Disclosure Vulnerability
Summary
Possible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
Impacted products
Vendor Product Version
Brocade SANnav Affected: Brocade SANnav before v2.3.0 and 2.2.2a
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-11-21T04:03:36.486Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://security.netapp.com/advisory/ntap-20240229-0005/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43937",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:54:03.897768Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T17:54:10.574Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before v2.3.0 and 2.2.2a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePossible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "Possible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T03:26:58.406Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22509"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav Information Disclosure Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43937",
    "datePublished": "2024-11-21T03:26:58.406Z",
    "dateReserved": "2022-10-26T19:34:16.362Z",
    "dateUpdated": "2024-11-21T17:54:10.574Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43954 (GCVE-0-2022-43954)

Vulnerability from cvelistv5 – Published: 2023-02-16 18:05 – Updated: 2024-10-22 20:50
VLAI
Summary
An insertion of sensitive information into log file vulnerability [CWE-532] in the FortiPortal management interface 7.0.0 through 7.0.2 may allow a remote authenticated attacker to read other devices' passwords in the audit log page.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Fortinet FortiPortal Affected: 7.0.0 , ≤ 7.0.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:04.994Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-22-430",
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-22-430"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43954",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-22T20:18:43.913620Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-22T20:50:45.705Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiPortal",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.0.2",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An insertion of sensitive information into log file vulnerability [CWE-532] in the FortiPortal management interface\u00a07.0.0 through 7.0.2 may allow a remote authenticated attacker to read other devices\u0027 passwords in the audit log page."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:R",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "Information disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-16T18:05:20.138Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.com/psirt/FG-IR-22-430",
          "url": "https://fortiguard.com/psirt/FG-IR-22-430"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiPortal version 7.0.3 or above "
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2022-43954",
    "datePublished": "2023-02-16T18:05:20.138Z",
    "dateReserved": "2022-10-27T07:40:06.590Z",
    "dateUpdated": "2024-10-22T20:50:45.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-44587 (GCVE-0-2022-44587)

Vulnerability from cvelistv5 – Published: 2024-06-21 15:54 – Updated: 2026-04-28 16:07
VLAI
Title
WordPress WP 2FA plugin <= 2.6.3 - Sensitive Data Exposure via Log File vulnerability
Summary
Insertion of Sensitive Information into Log File vulnerability in WP 2FA allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects WP 2FA: from n/a through 2.6.3.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
WP 2FA Affected: n/a , ≤ 2.6.3 (custom)
melapress wp_2fa Affected: 0 , ≤ 2.6.3 (custom)
    cpe:2.3:a:melapress:wp_2fa:*:*:*:*:*:wordpress:*:*
Create a notification for this product.
Credits
Snicco (Patchstack Alliance)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:melapress:wp_2fa:*:*:*:*:*:wordpress:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "wp_2fa",
            "vendor": "melapress",
            "versions": [
              {
                "lessThanOrEqual": "2.6.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-44587",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T19:16:54.015123Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T19:03:57.245Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:54:03.888Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://patchstack.com/database/vulnerability/wp-2fa/wordpress-wp-2fa-plugin-2-6-3-sensitive-data-exposure-via-log-file-vulnerability?_s_id=cve"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://wordpress.org/plugins",
          "defaultStatus": "unaffected",
          "packageName": "wp-2fa",
          "product": "WP 2FA",
          "versions": [
            {
              "changes": [
                {
                  "at": "2.6.4",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "2.6.3",
              "status": "affected",
              "version": "n/a",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Snicco (Patchstack Alliance)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Insertion of Sensitive Information into Log File vulnerability in WP 2FA allows Accessing Functionality Not Properly Constrained by ACLs.\u003cp\u003eThis issue affects WP 2FA: from n/a through 2.6.3.\u003c/p\u003e"
            }
          ],
          "value": "Insertion of Sensitive Information into Log File vulnerability in WP 2FA allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects WP 2FA: from n/a through 2.6.3."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-28T16:07:51.330Z",
        "orgId": "21595511-bba5-4825-b968-b78d1f9984a3",
        "shortName": "Patchstack"
      },
      "references": [
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://patchstack.com/database/vulnerability/wp-2fa/wordpress-wp-2fa-plugin-2-6-3-sensitive-data-exposure-via-log-file-vulnerability?_s_id=cve"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update to 2.6.4 or a higher version."
            }
          ],
          "value": "Update to 2.6.4 or a higher version."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WordPress WP 2FA plugin \u003c= 2.6.3 - Sensitive Data Exposure via Log File  vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "21595511-bba5-4825-b968-b78d1f9984a3",
    "assignerShortName": "Patchstack",
    "cveId": "CVE-2022-44587",
    "datePublished": "2024-06-21T15:54:52.534Z",
    "dateReserved": "2022-11-01T19:51:27.397Z",
    "dateUpdated": "2026-04-28T16:07:51.330Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation

Phases: Architecture and Design, Implementation

Description:

  • Consider seriously the sensitivity of the information written into log files. Do not write secrets into the log files.
Mitigation

Phase: Distribution

Description:

  • Remove debug log files before deploying the application into production.
Mitigation

Phase: Operation

Description:

  • Protect log files against unauthorized read/write.
Mitigation

Phase: Implementation

Description:

  • Adjust configurations appropriately when software is transitioned from a debug state to production.
CAPEC-215: Fuzzing for application mapping

An attacker sends random, malformed, or otherwise unexpected messages to a target application and observes the application's log or error messages returned. The attacker does not initially know how a target will respond to individual messages but by attempting a large number of message variants they may find a variant that trigger's desired behavior. In this attack, the purpose of the fuzzing is to observe the application's log and error messages, although fuzzing a target can also sometimes cause the target to enter an unstable state, causing a crash.

Back to CWE stats page