CWE-80

Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)

The product receives input from an upstream component, but it does not neutralize or incorrectly neutralizes special characters such as "<", ">", and "&" that could be interpreted as web-scripting elements when they are sent to a downstream component that processes web pages.

CVE-2022-20916 (GCVE-0-2022-20916)

Vulnerability from cvelistv5 – Published: 2022-07-21 04:05 – Updated: 2024-11-01 18:56
VLAI
Title
Cisco IoT Control Center Cross-Site Scripting Vulnerability
Summary
A vulnerability in the web-based management interface of Cisco IoT Control Center could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
Impacted products
Date Public
2022-07-20 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:31:58.585Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20220720 Cisco IoT Control Center Cross-Site Scripting Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-iotcc-xss-WQrCLRVd"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-20916",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-01T18:40:40.353155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-01T18:56:22.778Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco IoT Control Center",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2022-07-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco IoT Control Center could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-21T04:05:11.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20220720 Cisco IoT Control Center Cross-Site Scripting Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-iotcc-xss-WQrCLRVd"
        }
      ],
      "source": {
        "advisory": "cisco-sa-iotcc-xss-WQrCLRVd",
        "defect": [
          [
            "CSCwb73359"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco IoT Control Center Cross-Site Scripting Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2022-07-20T23:00:00",
          "ID": "CVE-2022-20916",
          "STATE": "PUBLIC",
          "TITLE": "Cisco IoT Control Center Cross-Site Scripting Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco IoT Control Center",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based management interface of Cisco IoT Control Center could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "6.1",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20220720 Cisco IoT Control Center Cross-Site Scripting Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-iotcc-xss-WQrCLRVd"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-iotcc-xss-WQrCLRVd",
          "defect": [
            [
              "CSCwb73359"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2022-20916",
    "datePublished": "2022-07-21T04:05:11.895Z",
    "dateReserved": "2021-11-02T00:00:00.000Z",
    "dateUpdated": "2024-11-01T18:56:22.778Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-21145 (GCVE-0-2022-21145)

Vulnerability from cvelistv5 – Published: 2022-04-14 19:56 – Updated: 2025-04-15 19:06
VLAI
Summary
A stored cross-site scripting vulnerability exists in the WebUserActions.aspx functionality of Lansweeper lansweeper 9.1.20.2. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
Impacted products
Vendor Product Version
Lansweeper lansweeper Affected: 9.1.20.2
Create a notification for this product.
Date Public
2022-02-28 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:31:58.707Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1442"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.lansweeper.com/changelog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-21145",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:23:30.665159Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T19:06:04.378Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "lansweeper",
          "vendor": "Lansweeper",
          "versions": [
            {
              "status": "affected",
              "version": "9.1.20.2"
            }
          ]
        }
      ],
      "datePublic": "2022-02-28T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A stored cross-site scripting vulnerability exists in the WebUserActions.aspx functionality of Lansweeper lansweeper 9.1.20.2. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-14T19:56:33.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1442"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.lansweeper.com/changelog/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2022-02-28",
          "ID": "CVE-2022-21145",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "lansweeper",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "9.1.20.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lansweeper"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stored cross-site scripting vulnerability exists in the WebUserActions.aspx functionality of Lansweeper lansweeper 9.1.20.2. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1442",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1442"
            },
            {
              "name": "https://www.lansweeper.com/changelog/",
              "refsource": "CONFIRM",
              "url": "https://www.lansweeper.com/changelog/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-21145",
    "datePublished": "2022-04-14T19:56:34.061Z",
    "dateReserved": "2022-01-10T00:00:00.000Z",
    "dateUpdated": "2025-04-15T19:06:04.378Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-21238 (GCVE-0-2022-21238)

Vulnerability from cvelistv5 – Published: 2022-05-12 17:01 – Updated: 2025-04-15 19:03
VLAI
Summary
A cross-site scripting (xss) vulnerability exists in the info.jsp functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
Impacted products
Date Public
2022-05-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:31:59.065Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1469"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-21238",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:18:15.747370Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T19:03:45.606Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "InRouter302",
          "vendor": "InHand Networks",
          "versions": [
            {
              "status": "affected",
              "version": "V3.5.4"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross-site scripting (xss) vulnerability exists in the info.jsp functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-12T17:01:29.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1469"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2022-05-10",
          "ID": "CVE-2022-21238",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "InRouter302",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "InHand Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A cross-site scripting (xss) vulnerability exists in the info.jsp functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf"
            },
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1469",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1469"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-21238",
    "datePublished": "2022-05-12T17:01:29.716Z",
    "dateReserved": "2022-02-22T00:00:00.000Z",
    "dateUpdated": "2025-04-15T19:03:45.606Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-23543 (GCVE-0-2022-23543)

Vulnerability from cvelistv5 – Published: 2022-12-19 21:30 – Updated: 2025-04-15 19:01
VLAI
Title
HTML attributes when attaching a YouTube link to the post
Summary
Silverware Games is a social network where people can play games online. Users can attach URLs to YouTube videos, the site will generate related `<iframe>` when the post will be published. The handler has some sort of protection so non-YouTube links can't be posted, as well as HTML tags are being stripped. However, it was still possible to add custom HTML attributes (e.g. `onclick=alert("xss")`) to the `<iframe>'. This issue was fixed in the version `1.1.34` and does not require any extra actions from our members. There has been no evidence that this vulnerability was used by anyone at this time.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:43:46.541Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://github.com/mesosoi/silverwaregames-io-issue-tracker/security/advisories/GHSA-62r9-4v3r-rw89",
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/mesosoi/silverwaregames-io-issue-tracker/security/advisories/GHSA-62r9-4v3r-rw89"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-23543",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T19:01:30.775175Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T19:01:44.429Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "silverwaregames-io-issue-tracker",
          "vendor": "mesosoi",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 1.1.34"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Silverware Games is a social network where people can play games online. Users can attach URLs to YouTube videos, the site will generate related `\u003ciframe\u003e` when the post will be published. The handler has some sort of protection so non-YouTube links can\u0027t be posted, as well as HTML tags are being stripped. However, it was still possible to add custom HTML attributes (e.g. `onclick=alert(\"xss\")`) to the `\u003ciframe\u003e\u0027. This issue was fixed in the version `1.1.34` and does not require any extra actions from our members. There has been no evidence that this vulnerability was used by anyone at this time."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-19T21:30:09.836Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/mesosoi/silverwaregames-io-issue-tracker/security/advisories/GHSA-62r9-4v3r-rw89",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/mesosoi/silverwaregames-io-issue-tracker/security/advisories/GHSA-62r9-4v3r-rw89"
        }
      ],
      "source": {
        "advisory": "GHSA-62r9-4v3r-rw89",
        "discovery": "UNKNOWN"
      },
      "title": "HTML attributes when attaching a YouTube link to the post"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-23543",
    "datePublished": "2022-12-19T21:30:09.836Z",
    "dateReserved": "2022-01-19T21:23:53.796Z",
    "dateUpdated": "2025-04-15T19:01:44.429Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24749 (GCVE-0-2022-24749)

Vulnerability from cvelistv5 – Published: 2022-03-14 21:45 – Updated: 2025-04-22 18:18
VLAI
Title
Basic Cross-site Scripting and Unrestricted Upload of File with Dangerous Type in Sylius
Summary
Sylius is an open source eCommerce platform. In versions prior to 1.9.10, 1.10.11, and 1.11.2, it is possible to upload an SVG file containing cross-site scripting (XSS) code in the admin panel. In order to perform a XSS attack, the file itself has to be open in a new card or loaded outside of the IMG tag. The problem applies both to the files opened on the admin panel and shop pages. The issue is fixed in versions 1.9.10, 1.10.11, and 1.11.2. As a workaround, require a library that adds on-upload file sanitization and overwrite the service before writing the file to the filesystem. The GitHub Security Advisory contains more specific information about the workaround.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
  • CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
Impacted products
Vendor Product Version
Sylius Sylius Affected: < 1.9.10
Affected: >= 1.10.0, < 1.10.11
Affected: >= 1.11.0, < 1.11.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:20:50.445Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Sylius/Sylius/releases/tag/v1.10.11"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Sylius/Sylius/releases/tag/v1.11.2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Sylius/Sylius/releases/tag/v1.9.10"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/Sylius/Sylius/security/advisories/GHSA-4qrp-27r3-66fj"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24749",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-22T15:49:14.780831Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-22T18:18:36.653Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Sylius",
          "vendor": "Sylius",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 1.9.10"
            },
            {
              "status": "affected",
              "version": "\u003e= 1.10.0, \u003c 1.10.11"
            },
            {
              "status": "affected",
              "version": "\u003e= 1.11.0, \u003c 1.11.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Sylius is an open source eCommerce platform. In versions prior to 1.9.10, 1.10.11, and 1.11.2, it is possible to upload an SVG file containing cross-site scripting (XSS) code in the admin panel. In order to perform a XSS attack, the file itself has to be open in a new card or loaded outside of the IMG tag. The problem applies both to the files opened on the admin panel and shop pages. The issue is fixed in versions 1.9.10, 1.10.11, and 1.11.2. As a workaround, require a library that adds on-upload file sanitization and overwrite the service before writing the file to the filesystem. The GitHub Security Advisory contains more specific information about the workaround."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-14T21:45:12.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Sylius/Sylius/releases/tag/v1.10.11"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Sylius/Sylius/releases/tag/v1.11.2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Sylius/Sylius/releases/tag/v1.9.10"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/Sylius/Sylius/security/advisories/GHSA-4qrp-27r3-66fj"
        }
      ],
      "source": {
        "advisory": "GHSA-4qrp-27r3-66fj",
        "discovery": "UNKNOWN"
      },
      "title": "Basic Cross-site Scripting and Unrestricted Upload of File with Dangerous Type in Sylius",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2022-24749",
          "STATE": "PUBLIC",
          "TITLE": "Basic Cross-site Scripting and Unrestricted Upload of File with Dangerous Type in Sylius"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Sylius",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 1.9.10"
                          },
                          {
                            "version_value": "\u003e= 1.10.0, \u003c 1.10.11"
                          },
                          {
                            "version_value": "\u003e= 1.11.0, \u003c 1.11.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Sylius"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Sylius is an open source eCommerce platform. In versions prior to 1.9.10, 1.10.11, and 1.11.2, it is possible to upload an SVG file containing cross-site scripting (XSS) code in the admin panel. In order to perform a XSS attack, the file itself has to be open in a new card or loaded outside of the IMG tag. The problem applies both to the files opened on the admin panel and shop pages. The issue is fixed in versions 1.9.10, 1.10.11, and 1.11.2. As a workaround, require a library that adds on-upload file sanitization and overwrite the service before writing the file to the filesystem. The GitHub Security Advisory contains more specific information about the workaround."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434: Unrestricted Upload of File with Dangerous Type"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Sylius/Sylius/releases/tag/v1.10.11",
              "refsource": "MISC",
              "url": "https://github.com/Sylius/Sylius/releases/tag/v1.10.11"
            },
            {
              "name": "https://github.com/Sylius/Sylius/releases/tag/v1.11.2",
              "refsource": "MISC",
              "url": "https://github.com/Sylius/Sylius/releases/tag/v1.11.2"
            },
            {
              "name": "https://github.com/Sylius/Sylius/releases/tag/v1.9.10",
              "refsource": "MISC",
              "url": "https://github.com/Sylius/Sylius/releases/tag/v1.9.10"
            },
            {
              "name": "https://github.com/Sylius/Sylius/security/advisories/GHSA-4qrp-27r3-66fj",
              "refsource": "CONFIRM",
              "url": "https://github.com/Sylius/Sylius/security/advisories/GHSA-4qrp-27r3-66fj"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-4qrp-27r3-66fj",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-24749",
    "datePublished": "2022-03-14T21:45:13.000Z",
    "dateReserved": "2022-02-10T00:00:00.000Z",
    "dateUpdated": "2025-04-22T18:18:36.653Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25620 (GCVE-0-2022-25620)

Vulnerability from cvelistv5 – Published: 2022-03-30 14:55 – Updated: 2024-08-03 04:42
VLAI
Title
Stored Cross-Site Scripting (XSS)
Summary
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability in Group Functionality of Profelis IT Consultancy SambaBox allows AUTHENTICATED user to cause execute arbitrary codes on the vulnerable server. This issue affects: Profelis IT Consultancy SambaBox 4.0 version 4.0 and prior versions on x86.
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
URL Tags
https://www.sambabox.io/sambabox-surum-4-0/ x_refsource_CONFIRM
Impacted products
Vendor Product Version
Profelis IT Consultancy SambaBox Affected: 4.0 , ≤ 4.0 (custom)
Create a notification for this product.
Credits
Volkan Erciyas
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.040Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.sambabox.io/sambabox-surum-4-0/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "x86"
          ],
          "product": "SambaBox",
          "vendor": "Profelis IT Consultancy",
          "versions": [
            {
              "lessThanOrEqual": "4.0",
              "status": "affected",
              "version": "4.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Volkan Erciyas"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability in Group Functionality of Profelis IT Consultancy SambaBox allows AUTHENTICATED user to cause execute arbitrary codes on the vulnerable server. This issue affects: Profelis IT Consultancy SambaBox 4.0 version 4.0 and prior versions on x86."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T14:55:11.000Z",
        "orgId": "3039e14d-1e9f-46c2-98a6-44436e4ca5d5",
        "shortName": "Profelis"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.sambabox.io/sambabox-surum-4-0/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade SambaBox to 4.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Stored Cross-Site Scripting (XSS)",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@profelis.com.tr",
          "ID": "CVE-2022-25620",
          "STATE": "PUBLIC",
          "TITLE": "Stored Cross-Site Scripting (XSS)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SambaBox",
                      "version": {
                        "version_data": [
                          {
                            "platform": "x86",
                            "version_affected": "\u003c=",
                            "version_name": "4.0",
                            "version_value": "4.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Profelis IT Consultancy"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Volkan Erciyas"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability in Group Functionality of Profelis IT Consultancy SambaBox allows AUTHENTICATED user to cause execute arbitrary codes on the vulnerable server. This issue affects: Profelis IT Consultancy SambaBox 4.0 version 4.0 and prior versions on x86."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.sambabox.io/sambabox-surum-4-0/",
              "refsource": "CONFIRM",
              "url": "https://www.sambabox.io/sambabox-surum-4-0/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade SambaBox to 4.1"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3039e14d-1e9f-46c2-98a6-44436e4ca5d5",
    "assignerShortName": "Profelis",
    "cveId": "CVE-2022-25620",
    "datePublished": "2022-03-30T14:55:11.000Z",
    "dateReserved": "2022-02-21T00:00:00.000Z",
    "dateUpdated": "2024-08-03T04:42:50.040Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25756 (GCVE-0-2022-25756)

Vulnerability from cvelistv5 – Published: 2022-04-12 09:07 – Updated: 2024-08-03 04:49
VLAI
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.
Severity
No CVSS data available.
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
Impacted products
Vendor Product Version
Siemens SCALANCE X302-7 EEC (230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X304-2FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X306-1LD FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH+ Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M PoE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M TS Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X320-1 FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X320-1-2LD FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X408-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M TS (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SIPLUS NET SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:52.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25756",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25756",
    "datePublished": "2022-04-12T09:07:52.000Z",
    "dateReserved": "2022-02-22T00:00:00.000Z",
    "dateUpdated": "2024-08-03T04:49:43.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28648 (GCVE-0-2022-28648)

Vulnerability from cvelistv5 – Published: 2022-04-05 17:55 – Updated: 2024-08-03 05:56
VLAI
Summary
In JetBrains YouTrack before 2022.1.43563 HTML code from the issue description was being rendered
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
Impacted products
Vendor Product Version
JetBrains YouTrack Affected: 2022.1.43563 , < 2022.1.43563 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:56:16.455Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "YouTrack",
          "vendor": "JetBrains",
          "versions": [
            {
              "lessThan": "2022.1.43563",
              "status": "affected",
              "version": "2022.1.43563",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In JetBrains YouTrack before 2022.1.43563 HTML code from the issue description was being rendered"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-05T17:55:17.000Z",
        "orgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
        "shortName": "JetBrains"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
        }
      ],
      "source": {
        "advisory": "JetBrains",
        "defect": [
          "JetBrains"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@jetbrains.com",
          "ID": "CVE-2022-28648",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "YouTrack",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "2022.1.43563",
                            "version_value": "2022.1.43563"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "JetBrains"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In JetBrains YouTrack before 2022.1.43563 HTML code from the issue description was being rendered"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.jetbrains.com/privacy-security/issues-fixed/",
              "refsource": "MISC",
              "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
            }
          ]
        },
        "source": {
          "advisory": "JetBrains",
          "defect": [
            "JetBrains"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
    "assignerShortName": "JetBrains",
    "cveId": "CVE-2022-28648",
    "datePublished": "2022-04-05T17:55:17.000Z",
    "dateReserved": "2022-04-04T00:00:00.000Z",
    "dateUpdated": "2024-08-03T05:56:16.455Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28703 (GCVE-0-2022-28703)

Vulnerability from cvelistv5 – Published: 2022-12-19 10:00 – Updated: 2025-04-15 18:39
VLAI
Summary
A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
Impacted products
Vendor Product Version
Lansweeper lansweeper Affected: 10.1.1.0
Create a notification for this product.
Date Public
2022-12-01 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:03:52.070Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28703",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:17:21.794878Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T18:39:02.214Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "lansweeper",
          "vendor": "Lansweeper",
          "versions": [
            {
              "status": "affected",
              "version": "10.1.1.0"
            }
          ]
        }
      ],
      "datePublic": "2022-12-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A stored cross-site scripting vulnerability exists in the HdConfigActions.aspx altertextlanguages functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary Javascript code injection. An attacker can send an HTTP request to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-15T00:00:00.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1532"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-28703",
    "datePublished": "2022-12-19T10:00:14.221Z",
    "dateReserved": "2022-06-09T00:00:00.000Z",
    "dateUpdated": "2025-04-15T18:39:02.214Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29168 (GCVE-0-2022-29168)

Vulnerability from cvelistv5 – Published: 2022-06-25 07:05 – Updated: 2025-04-23 18:08
VLAI
Title
Cross Site Scripting in Wire Messages
Summary
Wire is a secure messaging application. Wire is vulnerable to arbitrary HTML and Javascript execution via insufficient escaping when rendering `@mentions` in the wire-webapp. If a user receives and views a malicious message, arbitrary code is injected and executed in the context of the victim allowing the attacker to fully control the user account. Wire-desktop clients that are connected to a vulnerable wire-webapp version are also vulnerable to this attack. The issue has been fixed in wire-webapp 2022-05-04-production.0 and is already deployed on all Wire managed services. On-premise instances of wire-webapp need to be updated to docker tag 2022-05-04-production.0-v0.29.7-0-a6f2ded or wire-server 2022-05-04 (chart/4.11.0) or later. No known workarounds exist.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
Impacted products
Vendor Product Version
wireapp wire-webapp Affected: < 022-05-04-production.0
Affected: < 2022-05-04-production.0-v0.29.7-0-a6f2ded
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:17:54.056Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/wireapp/wire-webapp/security/advisories/GHSA-jgv3-4j56-fvh6"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-29168",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:52:05.946153Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T18:08:54.718Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "wire-webapp",
          "vendor": "wireapp",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 022-05-04-production.0"
            },
            {
              "status": "affected",
              "version": "\u003c 2022-05-04-production.0-v0.29.7-0-a6f2ded"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Wire is a secure messaging application. Wire is vulnerable to arbitrary HTML and Javascript execution via insufficient escaping when rendering `@mentions` in the wire-webapp. If a user receives and views a malicious message, arbitrary code is injected and executed in the context of the victim allowing the attacker to fully control the user account. Wire-desktop clients that are connected to a vulnerable wire-webapp version are also vulnerable to this attack. The issue has been fixed in wire-webapp 2022-05-04-production.0 and is already deployed on all Wire managed services. On-premise instances of wire-webapp need to be updated to docker tag 2022-05-04-production.0-v0.29.7-0-a6f2ded or wire-server 2022-05-04 (chart/4.11.0) or later. No known workarounds exist."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-25T07:05:09.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/wireapp/wire-webapp/security/advisories/GHSA-jgv3-4j56-fvh6"
        }
      ],
      "source": {
        "advisory": "GHSA-jgv3-4j56-fvh6",
        "discovery": "UNKNOWN"
      },
      "title": "Cross Site Scripting in Wire Messages",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2022-29168",
          "STATE": "PUBLIC",
          "TITLE": "Cross Site Scripting in Wire Messages"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "wire-webapp",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 022-05-04-production.0"
                          },
                          {
                            "version_value": "\u003c 2022-05-04-production.0-v0.29.7-0-a6f2ded"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "wireapp"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wire is a secure messaging application. Wire is vulnerable to arbitrary HTML and Javascript execution via insufficient escaping when rendering `@mentions` in the wire-webapp. If a user receives and views a malicious message, arbitrary code is injected and executed in the context of the victim allowing the attacker to fully control the user account. Wire-desktop clients that are connected to a vulnerable wire-webapp version are also vulnerable to this attack. The issue has been fixed in wire-webapp 2022-05-04-production.0 and is already deployed on all Wire managed services. On-premise instances of wire-webapp need to be updated to docker tag 2022-05-04-production.0-v0.29.7-0-a6f2ded or wire-server 2022-05-04 (chart/4.11.0) or later. No known workarounds exist."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/wireapp/wire-webapp/security/advisories/GHSA-jgv3-4j56-fvh6",
              "refsource": "CONFIRM",
              "url": "https://github.com/wireapp/wire-webapp/security/advisories/GHSA-jgv3-4j56-fvh6"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-jgv3-4j56-fvh6",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-29168",
    "datePublished": "2022-06-25T07:05:09.000Z",
    "dateReserved": "2022-04-13T00:00:00.000Z",
    "dateUpdated": "2025-04-23T18:08:54.718Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Implementation

Description:

  • Carefully check each input parameter against a rigorous positive specification (allowlist) defining the specific characters and format allowed. All input should be neutralized, not just parameters that the user is supposed to specify, but all data in the request, including hidden fields, cookies, headers, the URL itself, and so forth. A common mistake that leads to continuing XSS vulnerabilities is to validate only fields that are expected to be redisplayed by the site. We often encounter data from the request that is reflected by the application server or the application that the development team did not anticipate. Also, a field that is not currently reflected may be used by a future developer. Therefore, validating ALL parts of the HTTP request is recommended.
Mitigation ID: MIT-30.1

Phase: Implementation

Strategy: Output Encoding

Description:

  • Use and specify an output encoding that can be handled by the downstream component that is reading the output. Common encodings include ISO-8859-1, UTF-7, and UTF-8. When an encoding is not specified, a downstream component may choose a different encoding, either by assuming a default encoding or automatically inferring which encoding is being used, which can be erroneous. When the encodings are inconsistent, the downstream component might treat some character or byte sequences as special, even if they are not special in the original encoding. Attackers might then be able to exploit this discrepancy and conduct injection attacks; they even might be able to bypass protection mechanisms that assume the original encoding is also being used by the downstream component.
  • The problem of inconsistent output encodings often arises in web pages. If an encoding is not specified in an HTTP header, web browsers often guess about which encoding is being used. This can open up the browser to subtle XSS attacks.
Mitigation ID: MIT-43

Phase: Implementation

Description:

  • With Struts, write all data from form beans with the bean's filter attribute set to true.
Mitigation ID: MIT-31

Phase: Implementation

Strategy: Attack Surface Reduction

Description:

  • To help mitigate XSS attacks against the user's session cookie, set the session cookie to be HttpOnly. In browsers that support the HttpOnly feature (such as more recent versions of Internet Explorer and Firefox), this attribute can prevent the user's session cookie from being accessible to malicious client-side scripts that use document.cookie. This is not a complete solution, since HttpOnly is not supported by all browsers. More importantly, XmlHttpRequest and other powerful browser technologies provide read access to HTTP headers, including the Set-Cookie header in which the HttpOnly flag is set.
CAPEC-18: XSS Targeting Non-Script Elements

This attack is a form of Cross-Site Scripting (XSS) where malicious scripts are embedded in elements that are not expected to host scripts such as image tags (<img>), comments in XML documents (< !-CDATA->), etc. These tags may not be subject to the same input validation, output validation, and other content filtering and checking routines, so this can create an opportunity for an adversary to tunnel through the application's elements and launch a XSS attack through other elements. As with all remote attacks, it is important to differentiate the ability to launch an attack (such as probing an internal network for unpatched servers) and the ability of the remote adversary to collect and interpret the output of said attack.

CAPEC-193: PHP Remote File Inclusion

In this pattern the adversary is able to load and execute arbitrary code remotely available from the application. This is usually accomplished through an insecurely configured PHP runtime environment and an improperly sanitized "include" or "require" call, which the user can then control to point to any web-accessible file. This allows adversaries to hijack the targeted application and force it to execute their own instructions.

CAPEC-32: XSS Through HTTP Query Strings

An adversary embeds malicious script code in the parameters of an HTTP query string and convinces a victim to submit the HTTP request that contains the query string to a vulnerable web application. The web application then procedes to use the values parameters without properly validation them first and generates the HTML code that will be executed by the victim's browser.

CAPEC-86: XSS Through HTTP Headers

An adversary exploits web applications that generate web content, such as links in a HTML page, based on unvalidated or improperly validated data submitted by other actors. XSS in HTTP Headers attacks target the HTTP headers which are hidden from most users and may not be validated by web applications.