Search criteria
12 vulnerabilities found for 0852-1305/000-001 by WAGO
CVE-2021-20998 (GCVE-0-2021-20998)
Vulnerability from cvelistv5 – Published: 2021-05-13 13:45 – Updated: 2024-09-17 00:51
VLAI?
Title
WAGO: Managed Switches: Unauthorized creation of user accounts
Summary
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.
Severity ?
10 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.122Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:25",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Unauthorized creation of user accounts",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20998",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Unauthorized creation of user accounts"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20998",
"datePublished": "2021-05-13T13:45:25.179394Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-17T00:51:42.120Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20997 (GCVE-0-2021-20997)
Vulnerability from cvelistv5 – Published: 2021-05-13 13:45 – Updated: 2024-09-16 23:42
VLAI?
Title
WAGO: Managed Switches: Unauthorized access to password hashes
Summary
In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users.
Severity ?
7.5 (High)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.188Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:25",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Unauthorized access to password hashes",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20997",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Unauthorized access to password hashes"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20997",
"datePublished": "2021-05-13T13:45:25.054592Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-16T23:42:19.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20996 (GCVE-0-2021-20996)
Vulnerability from cvelistv5 – Published: 2021-05-13 13:45 – Updated: 2024-09-16 23:15
VLAI?
Title
WAGO: Managed Switches: Unsecure Cookie settings
Summary
In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties.
Severity ?
5.3 (Medium)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.100Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Unsecure Cookie settings",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20996",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Unsecure Cookie settings"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20996",
"datePublished": "2021-05-13T13:45:24.938129Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-16T23:15:25.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20995 (GCVE-0-2021-20995)
Vulnerability from cvelistv5 – Published: 2021-05-13 13:45 – Updated: 2024-09-17 04:24
VLAI?
Title
WAGO: Managed Switches: Storage of user credentials in a cookie
Summary
In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials.
Severity ?
5.3 (Medium)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.131Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Storage of user credentials in a cookie",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20995",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Storage of user credentials in a cookie"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312 Cleartext Storage of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20995",
"datePublished": "2021-05-13T13:45:24.828603Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-17T04:24:28.648Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20993 (GCVE-0-2021-20993)
Vulnerability from cvelistv5 – Published: 2021-05-13 13:45 – Updated: 2024-09-16 22:46
VLAI?
Title
WAGO: Managed Switches: Exposure of sensitive information through directory listing
Summary
In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory.
Severity ?
5.3 (Medium)
CWE
- CWE-200 - Information Exposure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Exposure of sensitive information through directory listing",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20993",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Exposure of sensitive information through directory listing"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200 Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20993",
"datePublished": "2021-05-13T13:45:24.560374Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-16T22:46:34.608Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20994 (GCVE-0-2021-20994)
Vulnerability from cvelistv5 – Published: 2021-05-13 13:45 – Updated: 2024-09-17 01:16
VLAI?
Title
WAGO: Managed Switches: Reflected Cross-site Scripting
Summary
In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management.
Severity ?
8.8 (High)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.102Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Reflected Cross-site Scripting",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20994",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Reflected Cross-site Scripting"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20994",
"datePublished": "2021-05-13T13:45:24.684398Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-17T01:16:25.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20998 (GCVE-0-2021-20998)
Vulnerability from nvd – Published: 2021-05-13 13:45 – Updated: 2024-09-17 00:51
VLAI?
Title
WAGO: Managed Switches: Unauthorized creation of user accounts
Summary
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.
Severity ?
10 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.122Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:25",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Unauthorized creation of user accounts",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20998",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Unauthorized creation of user accounts"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20998",
"datePublished": "2021-05-13T13:45:25.179394Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-17T00:51:42.120Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20997 (GCVE-0-2021-20997)
Vulnerability from nvd – Published: 2021-05-13 13:45 – Updated: 2024-09-16 23:42
VLAI?
Title
WAGO: Managed Switches: Unauthorized access to password hashes
Summary
In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users.
Severity ?
7.5 (High)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.188Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:25",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Unauthorized access to password hashes",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20997",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Unauthorized access to password hashes"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20997",
"datePublished": "2021-05-13T13:45:25.054592Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-16T23:42:19.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20996 (GCVE-0-2021-20996)
Vulnerability from nvd – Published: 2021-05-13 13:45 – Updated: 2024-09-16 23:15
VLAI?
Title
WAGO: Managed Switches: Unsecure Cookie settings
Summary
In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties.
Severity ?
5.3 (Medium)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.100Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Unsecure Cookie settings",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20996",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Unsecure Cookie settings"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20996",
"datePublished": "2021-05-13T13:45:24.938129Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-16T23:15:25.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20995 (GCVE-0-2021-20995)
Vulnerability from nvd – Published: 2021-05-13 13:45 – Updated: 2024-09-17 04:24
VLAI?
Title
WAGO: Managed Switches: Storage of user credentials in a cookie
Summary
In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials.
Severity ?
5.3 (Medium)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.131Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Storage of user credentials in a cookie",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20995",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Storage of user credentials in a cookie"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312 Cleartext Storage of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20995",
"datePublished": "2021-05-13T13:45:24.828603Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-17T04:24:28.648Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20993 (GCVE-0-2021-20993)
Vulnerability from nvd – Published: 2021-05-13 13:45 – Updated: 2024-09-16 22:46
VLAI?
Title
WAGO: Managed Switches: Exposure of sensitive information through directory listing
Summary
In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory.
Severity ?
5.3 (Medium)
CWE
- CWE-200 - Information Exposure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Exposure of sensitive information through directory listing",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20993",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Exposure of sensitive information through directory listing"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200 Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20993",
"datePublished": "2021-05-13T13:45:24.560374Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-16T22:46:34.608Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20994 (GCVE-0-2021-20994)
Vulnerability from nvd – Published: 2021-05-13 13:45 – Updated: 2024-09-17 01:16
VLAI?
Title
WAGO: Managed Switches: Reflected Cross-site Scripting
Summary
In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management.
Severity ?
8.8 (High)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 0852-0303 |
Affected:
unspecified , ≤ V1.2.3.S0
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
Credits
Dr. Tobias Augustin and Stephan Tigges of IKS – Institut für Kooperative Systeme GmbH, Kai Gaul and Jan Rübenach of ABO Wind AG, coordinated by CERT@VDE
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.102Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "0852-0303",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.2.3.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.7.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.1.6.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1305/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "0852-1505/000-001",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "V1.0.4.S0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"datePublic": "2021-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-13T13:45:24",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
],
"solutions": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"title": "WAGO: Managed Switches: Reflected Cross-site Scripting",
"workarounds": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-05-05T10:00:00.000Z",
"ID": "CVE-2021-20994",
"STATE": "PUBLIC",
"TITLE": "WAGO: Managed Switches: Reflected Cross-site Scripting"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "0852-0303",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.2.3.S0"
}
]
}
},
{
"product_name": "0852-1305",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.7.S0"
}
]
}
},
{
"product_name": "0852-1505",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.1.6.S0"
}
]
}
},
{
"product_name": "0852-1305/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
},
{
"product_name": "0852-1505/000-001",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "V1.0.4.S0"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en-us/advisories/vde-2021-013",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en-us/advisories/vde-2021-013"
}
]
},
"solution": [
{
"lang": "en",
"value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW \u003c 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW \u003e=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"
}
],
"source": {
"advisory": "VDE-2021-013",
"defect": [
"VDE-2021-013"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-20994",
"datePublished": "2021-05-13T13:45:24.684398Z",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-09-17T01:16:25.472Z",
"state": "PUBLISHED"
},