3 vulnerabilities found for 7km_pac_switched_ethernet_profinet_expansion_module_firmware by siemens

FKIE_CVE-2017-9945

Vulnerability from fkie_nvd - Published: 2017-08-30 19:29 - Updated: 2025-04-20 01:37
Summary
In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:7km_pac_switched_ethernet_profinet_expansion_module_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "349F42C5-B626-41A1-A35E-628438178816",
              "versionEndIncluding": "2.1.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:7km_pac_switched_ethernet_profinet_expansion_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A212F763-4EC8-4DEA-A667-86E694C4DD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions \u003c V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover."
    },
    {
      "lang": "es",
      "value": "En el m\u00f3dulo de expansi\u00f3n Siemens 7KM PAC Switched Ethernet PROFINET (todas las versiones anteriores a v2.1.3), se podr\u00eda provocar una denegaci\u00f3n de servicio mediante un paquete PROFINET DCP especialmente manipulado que se env\u00ede como una transmisi\u00f3n Ethernet local (capa 2). El componente afectado requiere un reinicio manual a trav\u00e9s del dispositivo principal que hay que recuperar."
    }
  ],
  "id": "CVE-2017-9945",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-08-30T19:29:00.367",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100562"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100562"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2017-9945 (GCVE-0-2017-9945)

Vulnerability from cvelistv5 – Published: 2017-08-30 19:00 – Updated: 2024-08-05 17:25
VLAI?
Summary
In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.
Severity ?
No CVSS data available.
CWE
  • Denial-of-Service
Assigner
References
Impacted products
Vendor Product Version
n/a Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3 Affected: Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.255Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100562",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100562"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3"
            }
          ]
        }
      ],
      "datePublic": "2017-08-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions \u003c V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial-of-Service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-02T09:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "100562",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100562"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-9945",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions \u003c V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial-of-Service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100562",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100562"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9945",
    "datePublished": "2017-08-30T19:00:00",
    "dateReserved": "2017-06-26T00:00:00",
    "dateUpdated": "2024-08-05T17:25:00.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9945 (GCVE-0-2017-9945)

Vulnerability from nvd – Published: 2017-08-30 19:00 – Updated: 2024-08-05 17:25
VLAI?
Summary
In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.
Severity ?
No CVSS data available.
CWE
  • Denial-of-Service
Assigner
References
Impacted products
Vendor Product Version
n/a Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3 Affected: Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.255Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100562",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100562"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3"
            }
          ]
        }
      ],
      "datePublic": "2017-08-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions \u003c V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial-of-Service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-02T09:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "100562",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100562"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-9945",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions \u003c V2.1.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions \u003c V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial-of-Service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100562",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100562"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9945",
    "datePublished": "2017-08-30T19:00:00",
    "dateReserved": "2017-06-26T00:00:00",
    "dateUpdated": "2024-08-05T17:25:00.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}