All the vulnerabilites related to Siemens - APOGEE PXC Compact (BACnet)
cve-2021-25677
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-03 20:11
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:28.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V0.5.0.0 \u003c V1.0.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003e= V0.5.0.0 \u003c V1.0.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:07.625Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-25677",
    "datePublished": "2021-04-22T20:42:21",
    "dateReserved": "2021-01-21T00:00:00",
    "dateUpdated": "2024-08-03T20:11:28.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31888
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity ?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31888",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31888",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31885
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity ?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.607Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-805",
              "description": "CWE-805: Buffer Access with Incorrect Length Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:34",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31885",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PLUSCONTROL 1st Gen",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-805: Buffer Access with Incorrect Length Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31885",
    "datePublished": "2021-11-09T11:31:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-45937
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-03 14:24
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:12.585Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-45937",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2024-08-03T14:24:03.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-27009
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:03
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:03:23.236Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-823",
              "description": "CWE-823: Use of Out-of-range Pointer Offset",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:02.298Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27009",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-12T00:00:00",
    "dateUpdated": "2024-08-04T16:03:23.236Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31882
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.782Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:46.326Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31882",
    "datePublished": "2021-11-09T11:31:55",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-10-08T08:39:46.326Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-28388
Vulnerability from cvelistv5
Published
2021-02-09 00:00
Modified
2024-08-04 16:33
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:58.999Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2012.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus ReadyStart V3 (All versions \u003c V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-342",
              "description": "CWE-342: Predictable Exact Value from Previous Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:06.562Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28388",
    "datePublished": "2021-02-09T00:00:00",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:58.999Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-27736
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.573Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:03.377Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27736",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-15795
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 13:30
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:30:21.684Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:01.115Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-15795",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-07-15T00:00:00",
    "dateUpdated": "2024-08-04T13:30:21.684Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31889
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-191",
              "description": "CWE-191: Integer Underflow (Wrap or Wraparound)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:49.251Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31889",
    "datePublished": "2021-11-09T11:32:01",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-10-08T08:39:49.251Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31890
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.798Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-240",
              "description": "CWE-240: Improper Handling of Inconsistent Structural Elements",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:50.678Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31890",
    "datePublished": "2021-11-09T11:32:02",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-10-08T08:39:50.678Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-27738
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.774Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:05.489Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27738",
    "datePublished": "2021-04-22T20:42:20",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.774Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31345
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.688Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:42.181Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31345",
    "datePublished": "2021-11-09T11:31:52",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2024-10-08T08:39:42.181Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-38371
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2024-09-17 13:53
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.448Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313313.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-935500.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-935500.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-313313.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38371",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T18:15:00.675232Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-17T13:53:27.567Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.21",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.21",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET for Nucleus PLUS V1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2a"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET for Nucleus PLUS V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3 V2012",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2012.08.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3 V2017",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.21), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.21), Desigo PXC00-E.D (All versions \u003e= V2.3), Desigo PXC00-U (All versions \u003e= V2.3), Desigo PXC001-E.D (All versions \u003e= V2.3), Desigo PXC100-E.D (All versions \u003e= V2.3), Desigo PXC12-E.D (All versions \u003e= V2.3), Desigo PXC128-U (All versions \u003e= V2.3), Desigo PXC200-E.D (All versions \u003e= V2.3), Desigo PXC22-E.D (All versions \u003e= V2.3), Desigo PXC22.1-E.D (All versions \u003e= V2.3), Desigo PXC36.1-E.D (All versions \u003e= V2.3), Desigo PXC50-E.D (All versions \u003e= V2.3), Desigo PXC64-U (All versions \u003e= V2.3), Desigo PXM20-E (All versions \u003e= V2.3), Nucleus NET for Nucleus PLUS V1 (All versions \u003c V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions \u003c V5.4), Nucleus ReadyStart V3 V2012 (All versions \u003c V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions \u003c V3.5.7), TALON TC Modular (BACnet) (All versions \u003c V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:31.390Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313313.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-935500.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-935500.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-313313.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-38371",
    "datePublished": "2022-10-11T00:00:00",
    "dateReserved": "2022-08-16T00:00:00",
    "dateUpdated": "2024-09-17T13:53:27.567Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31881
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:44.977Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31881",
    "datePublished": "2021-11-09T11:31:54",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-10-08T08:39:44.977Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31344
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:40.850Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31344",
    "datePublished": "2021-11-09T11:31:51",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2024-10-08T08:39:40.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-27391
Vulnerability from cvelistv5
Published
2021-09-14 10:47
Modified
2024-08-03 20:48
Severity ?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.974Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.6.3"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.6.3"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:31",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27391",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27391",
    "datePublished": "2021-09-14T10:47:31",
    "dateReserved": "2021-02-18T00:00:00",
    "dateUpdated": "2024-08-03T20:48:16.974Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-27737
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition  or leak the memory past the allocated structure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:04.435Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27737",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31883
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.182Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:47.805Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31883",
    "datePublished": "2021-11-09T11:31:56",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-10-08T08:39:47.805Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31346
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-10-08 08:39
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:43.642Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31346",
    "datePublished": "2021-11-09T11:31:53",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2024-10-08T08:39:43.642Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31884
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity ?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.775Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Capital VSTAR",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with enabled Ethernet options"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:33",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31884",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Capital VSTAR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions with enabled Ethernet options"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31884",
    "datePublished": "2021-11-09T11:31:57",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31887
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity ?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.650Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31887",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31887",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31886
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity ?
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:35",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31886",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31886",
    "datePublished": "2021-11-09T11:31:59",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.838Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}