GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    4 vulnerabilities found for Agent Service by Acer

    CVE-2026-50604 (GCVE-0-2026-50604)

    Vulnerability from nvd – Published: 2026-09-17 04:06 – Updated: 2026-09-17 12:52
    VLAI
    Title
    Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:52 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    References
    Impacted products
    Vendor Product Version
    Acer Agent Service Affected: * , ≤ 1.2.110.2 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50604",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:52:33.105111Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:52:56.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Agent Service",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.110.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
                }
              ],
              "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T07:55:36.264Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19871"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50604",
        "datePublished": "2026-09-17T04:06:40.354Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:52:56.787Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50603 (GCVE-0-2026-50603)

    Vulnerability from nvd – Published: 2026-09-17 04:01 – Updated: 2026-09-17 14:48
    VLAI
    Title
    Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense
    Summary
    A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 14:47 UTC
    CWE
    • CWE-321 - Hardcoded AES-128-ECB Key
    References
    Impacted products
    Vendor Product Version
    Acer Agent Service Affected: * , ≤ 1.2.110.2 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50603",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T14:47:57.377766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T14:48:17.751Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "Agent Service",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.110.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
                }
              ],
              "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Leveraging Hard-coded Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321 Hardcoded AES-128-ECB Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T07:54:47.332Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19878"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50603",
        "datePublished": "2026-09-17T04:01:12.295Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T14:48:17.751Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50604 (GCVE-0-2026-50604)

    Vulnerability from cvelistv5 – Published: 2026-09-17 04:06 – Updated: 2026-09-17 12:52
    VLAI
    Title
    Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:52 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    References
    Impacted products
    Vendor Product Version
    Acer Agent Service Affected: * , ≤ 1.2.110.2 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50604",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:52:33.105111Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:52:56.787Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Agent Service",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.110.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
                }
              ],
              "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T07:55:36.264Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19871"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50604",
        "datePublished": "2026-09-17T04:06:40.354Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:52:56.787Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50603 (GCVE-0-2026-50603)

    Vulnerability from cvelistv5 – Published: 2026-09-17 04:01 – Updated: 2026-09-17 14:48
    VLAI
    Title
    Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense
    Summary
    A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 14:47 UTC
    CWE
    • CWE-321 - Hardcoded AES-128-ECB Key
    References
    Impacted products
    Vendor Product Version
    Acer Agent Service Affected: * , ≤ 1.2.110.2 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50603",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T14:47:57.377766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T14:48:17.751Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "Agent Service",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.110.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
                }
              ],
              "value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Leveraging Hard-coded Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321 Hardcoded AES-128-ECB Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T07:54:47.332Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19878"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50603",
        "datePublished": "2026-09-17T04:01:12.295Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T14:48:17.751Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }