All the vulnerabilites related to CODESYS - CODESYS Control for Beckhoff CX9020 SL
cve-2022-22515
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 17:59
Severity ?
EPSS score ?
Summary
A component of the CODESYS Control runtime system allows read and write access to configuration files
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.437Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] } ], "datePublic": "2022-06-01T00:00:00", "descriptions": [ { "lang": "en", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-668", "description": "CWE-668 Exposure of Resource to Wrong Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-12T07:45:29", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "A component of the CODESYS Control runtime system allows read and write access to configuration files", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-06-01T10:00:00.000Z", "ID": "CVE-2022-22515", "STATE": "PUBLIC", "TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-668 Exposure of Resource to Wrong Sphere" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22515", "datePublished": "2022-04-07T18:21:16.280553Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-16T17:59:22.215Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-22519
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 03:22
Severity ?
EPSS score ?
Summary
Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.378Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] } ], "datePublic": "2022-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-126", "description": "CWE-126 Buffer Over-read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-27T05:55:13", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-06T10:00:00.000Z", "ID": "CVE-2022-22519", "STATE": "PUBLIC", "TITLE": "Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-126 Buffer Over-read" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download=", "refsource": "MISC", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22519", "datePublished": "2022-04-07T18:21:23.764420Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-17T03:22:45.345Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-22517
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 22:16
Severity ?
EPSS score ?
Summary
Communication Components in multiple CODESYS products vulnerable to communication channel disruption
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.454Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS OPC DA Server SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS PLCHandler", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] } ], "datePublic": "2022-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-334", "description": "CWE-334 Small Space of Random Values", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-07T18:21:19", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-06T10:00:00.000Z", "ID": "CVE-2022-22517", "STATE": "PUBLIC", "TITLE": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS OPC DA Server SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS PLCHandler", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-334 Small Space of Random Values" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=", "refsource": "MISC", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22517", "datePublished": "2022-04-07T18:21:20.091353Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-16T22:16:04.923Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-22518
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 02:11
Severity ?
EPSS score ?
Summary
A bug in the CODESYS V3 CmpUserMgr component fails to correctly apply a security policy.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.478Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17092\u0026token=a556b1695843bb42084dc63d5bdf553ca02ea393\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] } ], "datePublic": "2022-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "A bug in CmpUserMgr component can lead to only partially applied security policies. This can result in enabled, anonymous access to components part of the applied security policy." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276 Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-12T07:45:30", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17092\u0026token=a556b1695843bb42084dc63d5bdf553ca02ea393\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "A bug in the CODESYS V3 CmpUserMgr component fails to correctly apply a security policy.", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-06T10:00:00.000Z", "ID": "CVE-2022-22518", "STATE": "PUBLIC", "TITLE": "A bug in the CODESYS V3 CmpUserMgr component fails to correctly apply a security policy." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A bug in CmpUserMgr component can lead to only partially applied security policies. This can result in enabled, anonymous access to components part of the applied security policy." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276 Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17092\u0026token=a556b1695843bb42084dc63d5bdf553ca02ea393\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17092\u0026token=a556b1695843bb42084dc63d5bdf553ca02ea393\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22518", "datePublished": "2022-04-07T18:21:21.950776Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-17T02:11:34.421Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-22513
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 04:29
Severity ?
EPSS score ?
Summary
Null Pointer Dereference in multiple CODESYS products can lead to a DoS.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.460Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] } ], "datePublic": "2022-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476 NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-27T05:55:10", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "Null Pointer Dereference in multiple CODESYS products can lead to a DoS.", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-06T10:00:00.000Z", "ID": "CVE-2022-22513", "STATE": "PUBLIC", "TITLE": "Null Pointer Dereference in multiple CODESYS products can lead to a DoS." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-476 NULL Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=", "refsource": "MISC", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22513", "datePublished": "2022-04-07T18:21:12.792321Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-17T04:29:14.122Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-30791
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 16:48
Severity ?
EPSS score ?
Summary
CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:03:38.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.10", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] } ], "datePublic": "2022-07-08T00:00:00", "descriptions": [ { "lang": "en", "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-11T10:40:38", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "source": { "defect": [ "CERT@VDE#", "64129" ], "discovery": "UNKNOWN" }, "title": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-07-08T06:00:00.000Z", "ID": "CVE-2022-30791", "STATE": "PUBLIC", "TITLE": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.10" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400 Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ] }, "source": { "defect": [ "CERT@VDE#", "64129" ], "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-30791", "datePublished": "2022-07-11T10:40:38.913416Z", "dateReserved": "2022-05-16T00:00:00", "dateUpdated": "2024-09-16T16:48:31.565Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-30792
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 23:05
Severity ?
EPSS score ?
Summary
CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:03:38.599Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.10", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] } ], "datePublic": "2022-07-08T00:00:00", "descriptions": [ { "lang": "en", "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-11T10:40:43", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "source": { "defect": [ "CERT@VDE#", "64130" ], "discovery": "UNKNOWN" }, "title": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-07-08T06:00:00.000Z", "ID": "CVE-2022-30792", "STATE": "PUBLIC", "TITLE": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.10" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400 Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ] }, "source": { "defect": [ "CERT@VDE#", "64130" ], "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-30792", "datePublished": "2022-07-11T10:40:43.935648Z", "dateReserved": "2022-05-16T00:00:00", "dateUpdated": "2024-09-16T23:05:31.037Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-22514
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 03:03
Severity ?
EPSS score ?
Summary
Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.446Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] } ], "datePublic": "2022-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-822", "description": "CWE-822: Untrusted Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-27T05:55:11", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-06T10:00:00.000Z", "ID": "CVE-2022-22514", "STATE": "PUBLIC", "TITLE": "Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-822: Untrusted Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=", "refsource": "MISC", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22514", "datePublished": "2022-04-07T18:21:14.309072Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-17T03:03:50.086Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }