cve-2022-22515
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 17:59
Severity ?
EPSS score ?
Summary
A component of the CODESYS Control runtime system allows read and write access to configuration files
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.437Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom" } ] } ], "datePublic": "2022-06-01T00:00:00", "descriptions": [ { "lang": "en", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-668", "description": "CWE-668 Exposure of Resource to Wrong Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-12T07:45:29", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "A component of the CODESYS Control runtime system allows read and write access to configuration files", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-06-01T10:00:00.000Z", "ID": "CVE-2022-22515", "STATE": "PUBLIC", "TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.17.40" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-668 Exposure of Resource to Wrong Sphere" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22515", "datePublished": "2022-04-07T18:21:16.280553Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-16T17:59:22.215Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-22515\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2022-04-07T19:15:08.187\",\"lastModified\":\"2022-05-12T19:37:02.217\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto y autentificado podr\u00eda utilizar el programa de control del sistema de tiempo de ejecuci\u00f3n CODESYS Control para utilizar la vulnerabilidad con el fin de leer y modificar el/los archivo/s de configuraci\u00f3n de los productos afectados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.9},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-668\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"5C0588BE-2046-48F8-95E9-338FB009E2FA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_beckhoff_cx9020:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"45FF3C0B-9043-4E82-A8F3-95CB79D8DAA1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_empc-a\\\\/imx6_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"4CB8984E-ED1F-4F52-B016-F08C0D085C64\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"412EBC80-0D9C-419F-9DC3-E2054A8B93B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"AB585AB5-D0AC-46DC-9723-A0FEFBFB015C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"4F6E2A1D-0187-4C71-A87D-48B3EC3D99DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"A78E493B-6D9E-4196-830C-24BCF25D3D44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"F66AAE46-CCF8-46D6-89AD-5A4461FCECE9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"9D5DE9D1-C334-452C-A64B-D74A48017B6D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"AB1C57CE-152A-44AE-98B8-39E310255C8E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"01A94C91-B155-4A5A-9F0B-F7E04F3B23B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_rte_sl_\\\\(for_beckhoff_cx\\\\):*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"95BC26CF-75EE-43A2-8A92-E877CAF612F3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"1D85A5BC-ADB6-40E4-9434-B57C99185BBA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"AC013B85-98C0-4EF0-844C-4C75D1D237D9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"25737EE6-531E-4241-AA40-856388A2E333\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"E9F1B30B-6D52-40B1-ABD3-5164A76F5447\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"60E8930A-4C6C-41CE-8BA8-97332DC753FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.0\",\"matchCriteriaId\":\"879A9478-54E4-4B6E-A6DC-6DDE1C5E7745\"}]}]}],\"references\":[{\"url\":\"https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.