All the vulnerabilites related to Cisco - Cisco Intelligent Node Manager
cve-2024-20323
Vulnerability from cvelistv5
Published
2024-07-17 16:28
Modified
2024-08-01 21:59
Severity ?
EPSS score ?
Summary
A vulnerability in Cisco Intelligent Node (iNode) Software could allow an unauthenticated, remote attacker to hijack the TLS connection between Cisco iNode Manager and associated intelligent nodes and send arbitrary traffic to an affected device.
This vulnerability is due to the presence of hard-coded cryptographic material. An attacker in a man-in-the-middle position between Cisco iNode Manager and associated deployed nodes could exploit this vulnerability by using the static cryptographic key to generate a trusted certificate and impersonate an affected device. A successful exploit could allow the attacker to read data that is meant for a legitimate device, modify the startup configuration of an associated node, and, consequently, cause a denial of service (DoS) condition for downstream devices that are connected to the affected node.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-20323", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-22T20:07:08.038890Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-22T20:07:15.658Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T21:59:41.478Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "cisco-sa-inode-static-key-VUVCeynn", "tags": [ "x_transferred" ], "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-inode-static-key-VUVCeynn" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Cisco Intelligent Node Manager", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "N/A" } ] }, { "product": "Cisco Intelligent Node Software", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "N/A" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability in Cisco Intelligent Node (iNode) Software could allow an unauthenticated, remote attacker to hijack the TLS connection between Cisco iNode Manager and associated intelligent nodes and send arbitrary traffic to an affected device.\r\n\r This vulnerability is due to the presence of hard-coded cryptographic material. An attacker in a man-in-the-middle position between Cisco iNode Manager and associated deployed nodes could exploit this vulnerability by using the static cryptographic key to generate a trusted certificate and impersonate an affected device. A successful exploit could allow the attacker to read data that is meant for a legitimate device, modify the startup configuration of an associated node, and, consequently, cause a denial of service (DoS) condition for downstream devices that are connected to the affected node." } ], "exploits": [ { "lang": "en", "value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:N", "version": "3.1" }, "format": "cvssV3_1" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-321", "description": "Use of Hard-coded Cryptographic Key", "lang": "en", "type": "cwe" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-17T16:28:39.858Z", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "cisco-sa-inode-static-key-VUVCeynn", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-inode-static-key-VUVCeynn" } ], "source": { "advisory": "cisco-sa-inode-static-key-VUVCeynn", "discovery": "INTERNAL" } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2024-20323", "datePublished": "2024-07-17T16:28:39.858Z", "dateReserved": "2023-11-08T15:08:07.640Z", "dateUpdated": "2024-08-01T21:59:41.478Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }