All the vulnerabilites related to Cisco - Cisco Small Business 250 Series Smart Switches Software
cve-2019-12636
Vulnerability from cvelistv5
Published
2019-10-16 18:36
Modified
2024-11-21 19:09
Summary
A vulnerability in the web-based management interface of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the targeted user. If the user has administrative privileges, the attacker could alter the configuration, execute commands, or cause a denial of service (DoS) condition on an affected device.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:24:39.194Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20191016 Cisco Small Business Smart and Managed Switches Cross-Site Request Forgery Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-sbss-csrf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-12636",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T18:56:25.832896Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T19:09:59.032Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Small Business 250 Series Smart Switches Software",
          "vendor": "Cisco",
          "versions": [
            {
              "lessThan": "n/a",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the targeted user. If the user has administrative privileges, the attacker could alter the configuration, execute commands, or cause a denial of service (DoS) condition on an affected device."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-16T18:36:26",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20191016 Cisco Small Business Smart and Managed Switches Cross-Site Request Forgery Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-sbss-csrf"
        }
      ],
      "source": {
        "advisory": "cisco-sa-20191016-sbss-csrf",
        "defect": [
          [
            "CSCvo26471"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Small Business Smart and Managed Switches Cross-Site Request Forgery Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2019-10-16T16:00:00-0700",
          "ID": "CVE-2019-12636",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Small Business Smart and Managed Switches Cross-Site Request Forgery Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Small Business 250 Series Smart Switches Software",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based management interface of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack on an affected system. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the targeted user. If the user has administrative privileges, the attacker could alter the configuration, execute commands, or cause a denial of service (DoS) condition on an affected device."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "8.1",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-352"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20191016 Cisco Small Business Smart and Managed Switches Cross-Site Request Forgery Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-sbss-csrf"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-20191016-sbss-csrf",
          "defect": [
            [
              "CSCvo26471"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2019-12636",
    "datePublished": "2019-10-16T18:36:26.757740Z",
    "dateReserved": "2019-06-04T00:00:00",
    "dateUpdated": "2024-11-21T19:09:59.032Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-3496
Vulnerability from cvelistv5
Published
2020-08-26 16:15
Modified
2024-11-13 18:12
Summary
A vulnerability in the IPv6 packet processing engine of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of incoming IPv6 traffic. An attacker could exploit this vulnerability by sending a crafted IPv6 packet through an affected device. A successful exploit could allow the attacker to cause the switch management CLI to stop responding, resulting in a DoS condition. This vulnerability is specific to IPv6 traffic. IPv4 traffic is not affected.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T07:37:54.337Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20200819 Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sbss-ipv6-dos-tsgqbffW"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-3496",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:13:13.563970Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T18:12:35.608Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Small Business 250 Series Smart Switches Software",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-08-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the IPv6 packet processing engine of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of incoming IPv6 traffic. An attacker could exploit this vulnerability by sending a crafted IPv6 packet through an affected device. A successful exploit could allow the attacker to cause the switch management CLI to stop responding, resulting in a DoS condition. This vulnerability is specific to IPv6 traffic. IPv4 traffic is not affected."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-26T16:15:54",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20200819 Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sbss-ipv6-dos-tsgqbffW"
        }
      ],
      "source": {
        "advisory": "cisco-sa-sbss-ipv6-dos-tsgqbffW",
        "defect": [
          [
            "CSCvt45826"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-08-19T16:00:00",
          "ID": "CVE-2020-3496",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Small Business 250 Series Smart Switches Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the IPv6 packet processing engine of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of incoming IPv6 traffic. An attacker could exploit this vulnerability by sending a crafted IPv6 packet through an affected device. A successful exploit could allow the attacker to cause the switch management CLI to stop responding, resulting in a DoS condition. This vulnerability is specific to IPv6 traffic. IPv4 traffic is not affected."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "5.3",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20200819 Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sbss-ipv6-dos-tsgqbffW"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-sbss-ipv6-dos-tsgqbffW",
          "defect": [
            [
              "CSCvt45826"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-3496",
    "datePublished": "2020-08-26T16:15:54.968033Z",
    "dateReserved": "2019-12-12T00:00:00",
    "dateUpdated": "2024-11-13T18:12:35.608Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-15993
Vulnerability from cvelistv5
Published
2020-09-23 00:26
Modified
2024-11-13 18:03
Summary
A vulnerability in the web UI of Cisco Small Business Switches could allow an unauthenticated, remote attacker to access sensitive device information. The vulnerability exists because the software lacks proper authentication controls to information accessible from the web UI. An attacker could exploit this vulnerability by sending a malicious HTTP request to the web UI of an affected device. A successful exploit could allow the attacker to access sensitive device information, which includes configuration files.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:03:32.724Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20200129 Cisco Small Business Switches Information Disclosure Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20200129-smlbus-switch-disclos"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/171723/Cisco-Dell-Netgear-Information-Disclosure-Hash-Decrypter.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-15993",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:12:54.328085Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T18:03:35.211Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Small Business 250 Series Smart Switches Software",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-01-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web UI of Cisco Small Business Switches could allow an unauthenticated, remote attacker to access sensitive device information. The vulnerability exists because the software lacks proper authentication controls to information accessible from the web UI. An attacker could exploit this vulnerability by sending a malicious HTTP request to the web UI of an affected device. A successful exploit could allow the attacker to access sensitive device information, which includes configuration files."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-16",
              "description": "CWE-16",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-06T00:00:00",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20200129 Cisco Small Business Switches Information Disclosure Vulnerability",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20200129-smlbus-switch-disclos"
        },
        {
          "url": "http://packetstormsecurity.com/files/171723/Cisco-Dell-Netgear-Information-Disclosure-Hash-Decrypter.html"
        }
      ],
      "source": {
        "advisory": "cisco-sa-20200129-smlbus-switch-disclos",
        "defect": [
          [
            "CSCvr54104",
            "CSCvs68748"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Small Business Switches Information Disclosure Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2019-15993",
    "datePublished": "2020-09-23T00:26:59.726175Z",
    "dateReserved": "2019-09-06T00:00:00",
    "dateUpdated": "2024-11-13T18:03:35.211Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-3363
Vulnerability from cvelistv5
Published
2020-08-17 18:01
Modified
2024-11-13 18:14
Summary
A vulnerability in the IPv6 packet processing engine of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of incoming IPv6 traffic. An attacker could exploit this vulnerability by sending a crafted IPv6 packet through an affected device. A successful exploit could allow the attacker to cause an unexpected reboot of the switch, leading to a DoS condition. This vulnerability is specific to IPv6 traffic. IPv4 traffic is not affected.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T07:30:58.380Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20200805 Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sbss-ipv6-dos-3bLk6vA"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-3363",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:13:14.723571Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T18:14:20.628Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Small Business 250 Series Smart Switches Software",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-08-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the IPv6 packet processing engine of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of incoming IPv6 traffic. An attacker could exploit this vulnerability by sending a crafted IPv6 packet through an affected device. A successful exploit could allow the attacker to cause an unexpected reboot of the switch, leading to a DoS condition. This vulnerability is specific to IPv6 traffic. IPv4 traffic is not affected."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-17T18:01:25",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20200805 Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sbss-ipv6-dos-3bLk6vA"
        }
      ],
      "source": {
        "advisory": "cisco-sa-sbss-ipv6-dos-3bLk6vA",
        "defect": [
          [
            "CSCvt45834"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-08-05T16:00:00",
          "ID": "CVE-2020-3363",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Small Business 250 Series Smart Switches Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the IPv6 packet processing engine of Cisco Small Business Smart and Managed Switches could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of incoming IPv6 traffic. An attacker could exploit this vulnerability by sending a crafted IPv6 packet through an affected device. A successful exploit could allow the attacker to cause an unexpected reboot of the switch, leading to a DoS condition. This vulnerability is specific to IPv6 traffic. IPv4 traffic is not affected."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "8.6",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20200805 Cisco Small Business Smart and Managed Switches Denial of Service Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sbss-ipv6-dos-3bLk6vA"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-sbss-ipv6-dos-3bLk6vA",
          "defect": [
            [
              "CSCvt45834"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-3363",
    "datePublished": "2020-08-17T18:01:25.633674Z",
    "dateReserved": "2019-12-12T00:00:00",
    "dateUpdated": "2024-11-13T18:14:20.628Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}