All the vulnerabilites related to Rockwell Automation - CompactLogix 5370 L3 controllers
cve-2019-10954
Vulnerability from cvelistv5
Published
2019-05-01 18:59
Modified
2024-08-04 22:40
Severity ?
Summary
Rockwell Automation CompactLogix 5370 Stack-based Buffer Overflow
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.332Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
          },
          {
            "name": "108118",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108118"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5370 L1 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5370 L2 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5370 L3 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5370 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Armor Compact GuardLogix 5370 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "George Lashenko of CyberX reported to CISA."
        }
      ],
      "datePublic": "2019-04-30T14:35:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.\u003c/p\u003e"
            }
          ],
          "value": "An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.\n\n"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-20T14:39:32.258Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
        },
        {
          "name": "108118",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108118"
        },
        {
          "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eRockwell recommends the following:\u003c/p\u003e\u003cul\u003e\u003cli\u003eRockwell Automation strongly encourages users to apply the latest available version of firmware to keep up to date with the latest features, anomaly fixes, and security improvements. Update to a version of firmware as listed below that mitigates the associated risk:\u003c/li\u003e\u003cli\u003eApply FRN 31.011 or later from: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?Keyword=5370\u0026amp;crumb=112%C2%A0\"\u003ehttps://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?Keyword=5370\u0026amp;crumb=112 \u003c/a\u003e\u003c/li\u003e\u003cli\u003eFor EtherNet/IP-based vulnerabilities (ID 1-14), block all traffic to and from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP/UDP and Port 44818/TCP/UDP using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1\"\u003e898270\u003c/a\u003e\u0026nbsp;(login required).\u003cul\u003e\u003cli\u003eStratix users can use Device Manager or Studio 5000 Logix Designer to configure access control lists (ACL) to block/restrict ports. See section \u201cAccess Control Lists\u201d in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf\"\u003eStratix Managed Switches User Manual, publication 1783-UM007\u003c/a\u003e, for detailed instructions.\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003cli\u003eFor web-based vulnerabilities (ID 15-17), block all traffic from outside the Manufacturing Zone by blocking or restricting access to Port 80/443/TCP.\u003cul\u003e\u003cli\u003eStratix users can use Device Manager or Studio 5000 Logix Designer to configure ACL\u2019s to block/restrict ports. See section \u201cAccess Control Lists\u201d in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf\"\u003eStratix Managed Switches User Manual, publication 1783-UM007\u003c/a\u003e, for detailed instructions.\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003cli\u003eUtilize proper network infrastructure controls, such as firewalls, to help ensure that SMTP packets from unauthorized sources are blocked.\u003c/li\u003e\u003cli\u003eConsult the product documentation for specific features, such as a hardware key-switch setting, which may be used to block unauthorized changes, etc.\u003c/li\u003e\u003cli\u003eUse trusted software, software patches, and antivirus/antimalware programs and interact only with trusted websites and attachments.\u003c/li\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/494865/page/1\"\u003e494865\u003c/a\u003e\u0026nbsp;(login required).\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that a VPN is only as secure as the connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information please refer to Rockwell\u2019s Security Advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979\"\u003ehttps://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nRockwell recommends the following:\n\n  *  Rockwell Automation strongly encourages users to apply the latest available version of firmware to keep up to date with the latest features, anomaly fixes, and security improvements. Update to a version of firmware as listed below that mitigates the associated risk:\n  *  Apply FRN 31.011 or later from:  https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?Keyword=5370\u0026crumb=112  https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx \n  *  For EtherNet/IP-based vulnerabilities (ID 1-14), block all traffic to and from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP/UDP and Port 44818/TCP/UDP using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID  898270 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1 \u00a0(login required).  *  Stratix users can use Device Manager or Studio 5000 Logix Designer to configure access control lists (ACL) to block/restrict ports. See section \u201cAccess Control Lists\u201d in  Stratix Managed Switches User Manual, publication 1783-UM007 http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf , for detailed instructions.\n\n\n\n  *  For web-based vulnerabilities (ID 15-17), block all traffic from outside the Manufacturing Zone by blocking or restricting access to Port 80/443/TCP.  *  Stratix users can use Device Manager or Studio 5000 Logix Designer to configure ACL\u2019s to block/restrict ports. See section \u201cAccess Control Lists\u201d in  Stratix Managed Switches User Manual, publication 1783-UM007 http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf , for detailed instructions.\n\n\n\n  *  Utilize proper network infrastructure controls, such as firewalls, to help ensure that SMTP packets from unauthorized sources are blocked.\n  *  Consult the product documentation for specific features, such as a hardware key-switch setting, which may be used to block unauthorized changes, etc.\n  *  Use trusted software, software patches, and antivirus/antimalware programs and interact only with trusted websites and attachments.\n  *  Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID  494865 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/494865/page/1 \u00a0(login required).\n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that a VPN is only as secure as the connected devices.\n\n\nFor more information please refer to Rockwell\u2019s Security Advisory:  https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979 \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation CompactLogix 5370 Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10954",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 20 to 30.014 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CompactLogix"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 to 30.014 and earlier."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
            },
            {
              "name": "108118",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108118"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10954",
    "datePublished": "2019-05-01T18:59:28",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-6998
Vulnerability from cvelistv5
Published
2022-07-27 20:18
Modified
2024-08-04 09:18
Summary
Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.993Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1130398"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Armor Compact GuardLogix 5370 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Armor GuardLogix Safety Controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CompactLogix 5370 L1 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CompactLogix 5370 L2 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CompactLogix 5370 L3 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Compact GuardLogix 5370 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ControlLogix 5570 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThanOrEqual": "versions 33 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Yeop Chang reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CVE-22 Improper Input Validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-27T20:18:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1130398"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Rockwell Automation recommends affected users apply firmware v33.011 or later.\n\nFor more information see the Rockwell Automation advisory (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6998",
          "STATE": "PUBLIC",
          "TITLE": "Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Armor Compact GuardLogix 5370 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Armor GuardLogix Safety Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CompactLogix 5370 L1 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CompactLogix 5370 L2 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CompactLogix 5370 L3 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Compact GuardLogix 5370 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ControlLogix 5570 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "versions 33 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rockwell Automation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Yeop Chang reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CVE-22 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-02"
            },
            {
              "name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1130398",
              "refsource": "CONFIRM",
              "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1130398"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Rockwell Automation recommends affected users apply firmware v33.011 or later.\n\nFor more information see the Rockwell Automation advisory (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6998",
    "datePublished": "2022-07-27T20:18:00",
    "dateReserved": "2020-01-14T00:00:00",
    "dateUpdated": "2024-08-04T09:18:02.993Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10952
Vulnerability from cvelistv5
Published
2019-05-01 19:02
Modified
2024-08-04 22:40
Severity ?
Summary
Rockwell Automation CompactLogix 5370 Uncontrolled Resource Consumption
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.266Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
          },
          {
            "name": "108118",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108118"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5370 L1 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5370 L2 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5370 L3 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5370 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Armor Compact GuardLogix 5370 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "20 - 30",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Younes Dragoni of Nozomi Networks of CyberX reported to CISA."
        }
      ],
      "datePublic": "2019-04-30T14:35:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\n\n\nAn attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering \n\nCompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.\u003c/p\u003e"
            }
          ],
          "value": "\n\n\nAn attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering \n\nCompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.\n\n"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-20T16:33:25.067Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
        },
        {
          "name": "108118",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108118"
        },
        {
          "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003eRockwell Automation strongly encourages users to apply the latest available version of firmware to keep up to date with the latest features, anomaly fixes, and security improvements. Update firmware to version FRN 31.011 that mitigates the associated risk.\u003cbr\u003e\u003cbr\u003eRockwell Automation also recommends the following:\u003cbr\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?Keyword=5370\u0026amp;crumb=112%C2%A0\"\u003e \u003c/a\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eFor EtherNet/IP-based vulnerabilities (ID 1-14), block all traffic to and from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP/UDP and Port 44818/TCP/UDP using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1\"\u003e898270\u003c/a\u003e\u0026nbsp;(login required).\u003cul\u003e\u003cli\u003eStratix users can use Device Manager or Studio 5000 Logix Designer to configure access control lists (ACL) to block/restrict ports. See section \u201cAccess Control Lists\u201d in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf\"\u003eStratix Managed Switches User Manual, publication 1783-UM007\u003c/a\u003e, for detailed instructions.\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003cli\u003eFor web-based vulnerabilities (ID 15-17), block all traffic from outside the Manufacturing Zone by blocking or restricting access to Port 80/443/TCP.\u003cul\u003e\u003cli\u003eStratix users can use Device Manager or Studio 5000 Logix Designer to configure ACL\u2019s to block/restrict ports. See section \u201cAccess Control Lists\u201d in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf\"\u003eStratix Managed Switches User Manual, publication 1783-UM007\u003c/a\u003e, for detailed instructions.\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003cli\u003eUtilize proper network infrastructure controls, such as firewalls, to help ensure that SMTP packets from unauthorized sources are blocked.\u003c/li\u003e\u003cli\u003eConsult the product documentation for specific features, such as a hardware key-switch setting, which may be used to block unauthorized changes, etc.\u003c/li\u003e\u003cli\u003eUse trusted software, software patches, and antivirus/antimalware programs and interact only with trusted websites and attachments.\u003c/li\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/494865/page/1\"\u003e494865\u003c/a\u003e\u0026nbsp;(login required).\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that a VPN is only as secure as the connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information please refer to Rockwell\u2019s Security Advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979\"\u003ehttps://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\n\n\nRockwell Automation strongly encourages users to apply the latest available version of firmware to keep up to date with the latest features, anomaly fixes, and security improvements. Update firmware to version FRN 31.011 that mitigates the associated risk.\n\nRockwell Automation also recommends the following:\n   https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx \n\n  *  For EtherNet/IP-based vulnerabilities (ID 1-14), block all traffic to and from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP/UDP and Port 44818/TCP/UDP using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID  898270 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1 \u00a0(login required).  *  Stratix users can use Device Manager or Studio 5000 Logix Designer to configure access control lists (ACL) to block/restrict ports. See section \u201cAccess Control Lists\u201d in  Stratix Managed Switches User Manual, publication 1783-UM007 http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf , for detailed instructions.\n\n\n\n  *  For web-based vulnerabilities (ID 15-17), block all traffic from outside the Manufacturing Zone by blocking or restricting access to Port 80/443/TCP.  *  Stratix users can use Device Manager or Studio 5000 Logix Designer to configure ACL\u2019s to block/restrict ports. See section \u201cAccess Control Lists\u201d in  Stratix Managed Switches User Manual, publication 1783-UM007 http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf , for detailed instructions.\n\n\n\n  *  Utilize proper network infrastructure controls, such as firewalls, to help ensure that SMTP packets from unauthorized sources are blocked.\n  *  Consult the product documentation for specific features, such as a hardware key-switch setting, which may be used to block unauthorized changes, etc.\n  *  Use trusted software, software patches, and antivirus/antimalware programs and interact only with trusted websites and attachments.\n  *  Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID  494865 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/494865/page/1 \u00a0(login required).\n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that a VPN is only as secure as the connected devices.\n\n\nFor more information please refer to Rockwell\u2019s Security Advisory:  https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979 \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation CompactLogix 5370 Uncontrolled Resource Consumption",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10954",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 20 to 30.014 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CompactLogix"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 to 30.014 and earlier."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
            },
            {
              "name": "108118",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108118"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10952",
    "datePublished": "2019-05-01T19:02:42",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.266Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10955
Vulnerability from cvelistv5
Published
2019-04-25 17:27
Modified
2024-08-04 22:40
Severity ?
Summary
In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine.
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.190Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-113-01"
          },
          {
            "name": "108049",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "https://www.securityfocus.com/bid/108049"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MicroLogix 1400 Controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Series A"
            },
            {
              "status": "affected",
              "version": "All Versions Series B"
            },
            {
              "status": "affected",
              "version": "v15.002 and earlier"
            }
          ]
        },
        {
          "product": "MicroLogix 1100 Controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v14.00 and earlier"
            }
          ]
        },
        {
          "product": "CompactLogix 5370 L1 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v30.014 and earlier"
            }
          ]
        },
        {
          "product": "CompactLogix 5370 L2 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v30.014 and earlier"
            }
          ]
        },
        {
          "product": "CompactLogix 5370 L3 controllers",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v30.014 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2019-04-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user\u2019s machine."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "URL REDIRECTION TO UNTRUSTED SITE (\u0027OPEN REDIRECT\u0027) CWE-601",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-25T17:27:32",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-113-01"
        },
        {
          "name": "108049",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "https://www.securityfocus.com/bid/108049"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10955",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MicroLogix 1400 Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Series A"
                          },
                          {
                            "version_value": "All Versions Series B"
                          },
                          {
                            "version_value": "v15.002 and earlier"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MicroLogix 1100 Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v14.00 and earlier"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CompactLogix 5370 L1 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v30.014 and earlier"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CompactLogix 5370 L2 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v30.014 and earlier"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CompactLogix 5370 L3 controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v30.014 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rockwell Automation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user\u2019s machine."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "URL REDIRECTION TO UNTRUSTED SITE (\u0027OPEN REDIRECT\u0027) CWE-601"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-113-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-113-01"
            },
            {
              "name": "108049",
              "refsource": "BID",
              "url": "https://www.securityfocus.com/bid/108049"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10955",
    "datePublished": "2019-04-25T17:27:32",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.190Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}