Search criteria

6 vulnerabilities found for Control Center by ASUS

VAR-202206-1629

Vulnerability from variot - Updated: 2023-12-18 13:59

ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202206-1629",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "control center",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "asus",
        "version": "1.4.2.5"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:asus:control_center:1.4.2.5:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      }
    ]
  },
  "cve": "CVE-2022-26668",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-417337",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULMON",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-26668",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.1,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "twcert@cert.org.tw",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-26668",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "twcert@cert.org.tw",
            "id": "CVE-2022-26668",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202206-2018",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-417337",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-26668",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26668"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26668"
      }
    ],
    "trust": 1.08
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-26668",
        "trust": 1.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-417337",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26668",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26668"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "id": "VAR-202206-1629",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T13:59:40.466000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "ASUS Control Center Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=198148"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-863",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-26668/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/863.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26668"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26668"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "date": "2022-06-20T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26668"
      },
      {
        "date": "2022-06-20T06:15:08.827000",
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "date": "2022-06-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-417337"
      },
      {
        "date": "2022-06-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26668"
      },
      {
        "date": "2022-06-27T18:46:18.067000",
        "db": "NVD",
        "id": "CVE-2022-26668"
      },
      {
        "date": "2022-07-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ASUS Control Center Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2018"
      }
    ],
    "trust": 0.6
  }
}

VAR-202206-1464

Vulnerability from variot - Updated: 2023-12-18 11:55

ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data. The software can monitor and control ASUS servers and workstations

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202206-1464",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "control center",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "asus",
        "version": "1.4.2.5"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:asus:control_center:1.4.2.5:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      }
    ]
  },
  "cve": "CVE-2022-26669",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "VHN-417338",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULMON",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2022-26669",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.1,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "twcert@cert.org.tw",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-26669",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "twcert@cert.org.tw",
            "id": "CVE-2022-26669",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202206-2017",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-417338",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-26669",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26669"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data. The software can monitor and control ASUS servers and workstations",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26669"
      }
    ],
    "trust": 1.08
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-26669",
        "trust": 1.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-62186",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-417338",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26669",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26669"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "id": "VAR-202206-1464",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T11:55:56.931000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "ASUS Control Center SQL Repair measures for injecting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=197756"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-89",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-26669/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/89.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26669"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26669"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "date": "2022-06-20T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26669"
      },
      {
        "date": "2022-06-20T06:15:08.903000",
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "date": "2022-06-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-06-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-417338"
      },
      {
        "date": "2022-06-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26669"
      },
      {
        "date": "2022-06-27T18:45:05.067000",
        "db": "NVD",
        "id": "CVE-2022-26669"
      },
      {
        "date": "2022-07-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ASUS Control Center SQL Injection vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SQL injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2017"
      }
    ],
    "trust": 0.6
  }
}

CVE-2022-26669 (GCVE-0-2022-26669)

Vulnerability from cvelistv5 – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
VLAI
Title
ASUS Control Center - SQL Injection
Summary
ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data.
CWE
Assigner
References
Impacted products
Vendor Product Version
ASUS Control Center Affected: 1.4.2.5
Create a notification for this product.
Date Public
2022-04-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:11:44.296Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Control Center",
          "vendor": "ASUS",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.2.5"
            }
          ]
        }
      ],
      "datePublic": "2022-04-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-20T05:30:30.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update version to 1.4.3.2"
        }
      ],
      "source": {
        "advisory": "TVN-202203002",
        "discovery": "EXTERNAL"
      },
      "title": "ASUS Control Center - SQL Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
          "ID": "CVE-2022-26669",
          "STATE": "PUBLIC",
          "TITLE": "ASUS Control Center - SQL Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Control Center",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4.2.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ASUS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update version to 1.4.3.2"
          }
        ],
        "source": {
          "advisory": "TVN-202203002",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2022-26669",
    "datePublished": "2022-06-20T05:30:31.029Z",
    "dateReserved": "2022-03-08T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:42:16.801Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26668 (GCVE-0-2022-26668)

Vulnerability from cvelistv5 – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
VLAI
Title
ASUS Control Center - Broken Access Control
Summary
ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
ASUS Control Center Affected: 1.4.2.5
Create a notification for this product.
Date Public
2022-04-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:11:43.535Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Control Center",
          "vendor": "ASUS",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.2.5"
            }
          ]
        }
      ],
      "datePublic": "2022-04-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-20T05:30:29.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update version to 1.4.3.2"
        }
      ],
      "source": {
        "advisory": "TVN-202203001",
        "discovery": "EXTERNAL"
      },
      "title": "ASUS Control Center - Broken Access Control",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
          "ID": "CVE-2022-26668",
          "STATE": "PUBLIC",
          "TITLE": "ASUS Control Center - Broken Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Control Center",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4.2.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ASUS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update version to 1.4.3.2"
          }
        ],
        "source": {
          "advisory": "TVN-202203001",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2022-26668",
    "datePublished": "2022-06-20T05:30:29.581Z",
    "dateReserved": "2022-03-08T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:42:54.277Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26669 (GCVE-0-2022-26669)

Vulnerability from nvd – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
VLAI
Title
ASUS Control Center - SQL Injection
Summary
ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data.
CWE
Assigner
References
Impacted products
Vendor Product Version
ASUS Control Center Affected: 1.4.2.5
Create a notification for this product.
Date Public
2022-04-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:11:44.296Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Control Center",
          "vendor": "ASUS",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.2.5"
            }
          ]
        }
      ],
      "datePublic": "2022-04-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-20T05:30:30.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update version to 1.4.3.2"
        }
      ],
      "source": {
        "advisory": "TVN-202203002",
        "discovery": "EXTERNAL"
      },
      "title": "ASUS Control Center - SQL Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
          "ID": "CVE-2022-26669",
          "STATE": "PUBLIC",
          "TITLE": "ASUS Control Center - SQL Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Control Center",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4.2.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ASUS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update version to 1.4.3.2"
          }
        ],
        "source": {
          "advisory": "TVN-202203002",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2022-26669",
    "datePublished": "2022-06-20T05:30:31.029Z",
    "dateReserved": "2022-03-08T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:42:16.801Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26668 (GCVE-0-2022-26668)

Vulnerability from nvd – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
VLAI
Title
ASUS Control Center - Broken Access Control
Summary
ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
ASUS Control Center Affected: 1.4.2.5
Create a notification for this product.
Date Public
2022-04-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:11:43.535Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Control Center",
          "vendor": "ASUS",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.2.5"
            }
          ]
        }
      ],
      "datePublic": "2022-04-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-20T05:30:29.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update version to 1.4.3.2"
        }
      ],
      "source": {
        "advisory": "TVN-202203001",
        "discovery": "EXTERNAL"
      },
      "title": "ASUS Control Center - Broken Access Control",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
          "ID": "CVE-2022-26668",
          "STATE": "PUBLIC",
          "TITLE": "ASUS Control Center - Broken Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Control Center",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4.2.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ASUS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update version to 1.4.3.2"
          }
        ],
        "source": {
          "advisory": "TVN-202203001",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2022-26668",
    "datePublished": "2022-06-20T05:30:29.581Z",
    "dateReserved": "2022-03-08T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:42:54.277Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}