Search criteria
2 vulnerabilities found for D7-PS1010/D7-PS1030 by Solidigm
CVE-2025-9195 (GCVE-0-2025-9195)
Vulnerability from cvelistv5 – Published: 2025-08-28 18:01 – Updated: 2025-08-28 18:32
VLAI?
Summary
Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Solidigm | D7-PS1010/D7-PS1030 |
Affected:
G75YG100 / G75YG150 (PRQ3 CPC)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9195",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-28T18:32:10.576953Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T18:32:17.579Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "D7-PS1010/D7-PS1030",
"vendor": "Solidigm",
"versions": [
{
"status": "affected",
"version": "G75YG100 / G75YG150 (PRQ3 CPC)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service"
}
],
"value": "Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service"
}
],
"impacts": [
{
"capecId": "CAPEC-113",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-113 Interface Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T18:01:40.123Z",
"orgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"shortName": "Solidigm"
},
"references": [
{
"url": "https://www.solidigm.com/support-page/support-security.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"assignerShortName": "Solidigm",
"cveId": "CVE-2025-9195",
"datePublished": "2025-08-28T18:01:40.123Z",
"dateReserved": "2025-08-19T17:15:42.201Z",
"dateUpdated": "2025-08-28T18:32:17.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9195 (GCVE-0-2025-9195)
Vulnerability from nvd – Published: 2025-08-28 18:01 – Updated: 2025-08-28 18:32
VLAI?
Summary
Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Solidigm | D7-PS1010/D7-PS1030 |
Affected:
G75YG100 / G75YG150 (PRQ3 CPC)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9195",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-28T18:32:10.576953Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T18:32:17.579Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "D7-PS1010/D7-PS1030",
"vendor": "Solidigm",
"versions": [
{
"status": "affected",
"version": "G75YG100 / G75YG150 (PRQ3 CPC)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service"
}
],
"value": "Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service"
}
],
"impacts": [
{
"capecId": "CAPEC-113",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-113 Interface Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T18:01:40.123Z",
"orgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"shortName": "Solidigm"
},
"references": [
{
"url": "https://www.solidigm.com/support-page/support-security.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"assignerShortName": "Solidigm",
"cveId": "CVE-2025-9195",
"datePublished": "2025-08-28T18:01:40.123Z",
"dateReserved": "2025-08-19T17:15:42.201Z",
"dateUpdated": "2025-08-28T18:32:17.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}