CVE-2025-9195 (GCVE-0-2025-9195)
Vulnerability from cvelistv5 – Published: 2025-08-28 18:01 – Updated: 2025-08-28 18:32
VLAI?
Summary
Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Solidigm | D7-PS1010/D7-PS1030 |
Affected:
G75YG100 / G75YG150 (PRQ3 CPC)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9195",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-28T18:32:10.576953Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T18:32:17.579Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "D7-PS1010/D7-PS1030",
"vendor": "Solidigm",
"versions": [
{
"status": "affected",
"version": "G75YG100 / G75YG150 (PRQ3 CPC)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service"
}
],
"value": "Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service"
}
],
"impacts": [
{
"capecId": "CAPEC-113",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-113 Interface Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T18:01:40.123Z",
"orgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"shortName": "Solidigm"
},
"references": [
{
"url": "https://www.solidigm.com/support-page/support-security.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"assignerShortName": "Solidigm",
"cveId": "CVE-2025-9195",
"datePublished": "2025-08-28T18:01:40.123Z",
"dateReserved": "2025-08-19T17:15:42.201Z",
"dateUpdated": "2025-08-28T18:32:17.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-9195\",\"sourceIdentifier\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"published\":\"2025-08-28T18:15:34.347\",\"lastModified\":\"2025-08-29T16:24:29.730\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://www.solidigm.com/support-page/support-security.html\",\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9195\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-28T18:32:10.576953Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-28T18:32:14.810Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-113\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-113 Interface Manipulation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.4, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Solidigm\", \"product\": \"D7-PS1010/D7-PS1030\", \"versions\": [{\"status\": \"affected\", \"version\": \"G75YG100 / G75YG150 (PRQ3 CPC)\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.solidigm.com/support-page/support-security.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Improper input validation in firmware of some Solidigm DC Products may allow an attacker with local access to cause a Denial of Service\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"shortName\": \"Solidigm\", \"dateUpdated\": \"2025-08-28T18:01:40.123Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-9195\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-28T18:32:17.579Z\", \"dateReserved\": \"2025-08-19T17:15:42.201Z\", \"assignerOrgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"datePublished\": \"2025-08-28T18:01:40.123Z\", \"assignerShortName\": \"Solidigm\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…