Search criteria
12 vulnerabilities found for DAR-7000-40 by D-Link
CVE-2024-4965 (GCVE-0-2024-4965)
Vulnerability from cvelistv5 – Published: 2024-05-16 07:31 – Updated: 2024-08-08 14:41 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 resmanage.php os command injection
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This issue affects some unknown processing of the file /useratte/resmanage.php. The manipulation of the argument load leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264533 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264533 | D-Link DAR-7000-40 resmanage.php os command injection",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264533"
},
{
"name": "VDB-264533 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264533"
},
{
"name": "Submit #333784 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Command Injection",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333784"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_RCE_%20resmanage.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4965",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T15:12:00.253977Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-08T14:41:28.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This issue affects some unknown processing of the file /useratte/resmanage.php. The manipulation of the argument load leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264533 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in D-Link DAR-7000-40 V31R02B1413C gefunden. Betroffen davon ist ein unbekannter Prozess der Datei /useratte/resmanage.php. Mittels dem Manipulieren des Arguments load mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T07:31:07.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264533 | D-Link DAR-7000-40 resmanage.php os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264533"
},
{
"name": "VDB-264533 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264533"
},
{
"name": "Submit #333784 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333784"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_RCE_%20resmanage.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 resmanage.php os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4965",
"datePublished": "2024-05-16T07:31:07.390Z",
"dateReserved": "2024-05-15T19:14:58.963Z",
"dateUpdated": "2024-08-08T14:41:28.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4964 (GCVE-0-2024-4964)
Vulnerability from cvelistv5 – Published: 2024-05-16 07:31 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 urlblist.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This vulnerability affects unknown code of the file /firewall/urlblist.php. The manipulation of the argument file leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264532. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:d-link:dar-7000-40:v31r02b1413c:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "dar-7000-40",
"vendor": "d-link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4964",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-30T18:32:03.976608Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:55:00.322Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264532 | D-Link DAR-7000-40 urlblist.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264532"
},
{
"name": "VDB-264532 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264532"
},
{
"name": "Submit #333783 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333783"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20urlblist.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This vulnerability affects unknown code of the file /firewall/urlblist.php. The manipulation of the argument file leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264532. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "In D-Link DAR-7000-40 V31R02B1413C wurde eine kritische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Datei /firewall/urlblist.php. Durch Manipulation des Arguments file mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T07:31:05.221Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264532 | D-Link DAR-7000-40 urlblist.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264532"
},
{
"name": "VDB-264532 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264532"
},
{
"name": "Submit #333783 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333783"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20urlblist.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 urlblist.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4964",
"datePublished": "2024-05-16T07:31:05.221Z",
"dateReserved": "2024-05-15T19:14:56.124Z",
"dateUpdated": "2024-08-01T20:55:10.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4963 (GCVE-0-2024-4963)
Vulnerability from cvelistv5 – Published: 2024-05-16 07:00 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 url.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-7000-40 V31R02B1413C. This affects an unknown part of the file /url/url.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-264531. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T15:18:57.582598Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:56:17.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.367Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264531 | D-Link DAR-7000-40 url.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264531"
},
{
"name": "VDB-264531 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264531"
},
{
"name": "Submit #333781 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333781"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20url.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-7000-40 V31R02B1413C. This affects an unknown part of the file /url/url.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-264531. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in D-Link DAR-7000-40 V31R02B1413C gefunden. Hiervon betroffen ist ein unbekannter Codeblock der Datei /url/url.php. Durch die Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T07:00:05.986Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264531 | D-Link DAR-7000-40 url.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264531"
},
{
"name": "VDB-264531 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264531"
},
{
"name": "Submit #333781 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333781"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20url.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 url.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4963",
"datePublished": "2024-05-16T07:00:05.986Z",
"dateReserved": "2024-05-15T19:14:46.570Z",
"dateUpdated": "2024-08-01T20:55:10.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4962 (GCVE-0-2024-4962)
Vulnerability from cvelistv5 – Published: 2024-05-16 06:31 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 resmanage.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000-40 V31R02B1413C. Affected by this issue is some unknown functionality of the file /useratte/resmanage.php. The manipulation of the argument file leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-264530 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:d-link:dar-7000-40:v31r02b1413c:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "dar-7000-40",
"vendor": "d-link",
"versions": [
{
"status": "affected",
"version": "v31r02b1413c"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4962",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T17:31:54.325504Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:56:12.173Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264530 | D-Link DAR-7000-40 resmanage.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264530"
},
{
"name": "VDB-264530 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264530"
},
{
"name": "Submit #333780 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333780"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20resmanage.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000-40 V31R02B1413C. Affected by this issue is some unknown functionality of the file /useratte/resmanage.php. The manipulation of the argument file leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-264530 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in D-Link DAR-7000-40 V31R02B1413C entdeckt. Davon betroffen ist unbekannter Code der Datei /useratte/resmanage.php. Mit der Manipulation des Arguments file mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T06:31:04.878Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264530 | D-Link DAR-7000-40 resmanage.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264530"
},
{
"name": "VDB-264530 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264530"
},
{
"name": "Submit #333780 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333780"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20resmanage.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 resmanage.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4962",
"datePublished": "2024-05-16T06:31:04.878Z",
"dateReserved": "2024-05-15T19:14:43.902Z",
"dateUpdated": "2024-08-01T20:55:10.358Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4961 (GCVE-0-2024-4961)
Vulnerability from cvelistv5 – Published: 2024-05-16 06:00 – Updated: 2024-08-23 17:42 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 onlineuser.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-7000-40 V31R02B1413C. Affected by this vulnerability is an unknown functionality of the file /user/onlineuser.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264529 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264529 | D-Link DAR-7000-40 onlineuser.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264529"
},
{
"name": "VDB-264529 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264529"
},
{
"name": "Submit #333779 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333779"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20onlineuser.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4961",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T17:34:15.479200Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T17:42:36.505Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-7000-40 V31R02B1413C. Affected by this vulnerability is an unknown functionality of the file /user/onlineuser.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264529 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "In D-Link DAR-7000-40 V31R02B1413C wurde eine kritische Schwachstelle entdeckt. Hierbei betrifft es unbekannten Programmcode der Datei /user/onlineuser.php. Dank Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T06:00:06.797Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264529 | D-Link DAR-7000-40 onlineuser.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264529"
},
{
"name": "VDB-264529 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264529"
},
{
"name": "Submit #333779 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333779"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20onlineuser.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 onlineuser.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4961",
"datePublished": "2024-05-16T06:00:06.797Z",
"dateReserved": "2024-05-15T19:14:40.952Z",
"dateUpdated": "2024-08-23T17:42:36.505Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4960 (GCVE-0-2024-4960)
Vulnerability from cvelistv5 – Published: 2024-05-16 05:31 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 licenseauthorization.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000-40 V31R02B1413C. Affected is an unknown function of the file interface/sysmanage/licenseauthorization.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4960",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T15:14:17.718356Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:53:14.892Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.441Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264528 | D-Link DAR-7000-40 licenseauthorization.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264528"
},
{
"name": "VDB-264528 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264528"
},
{
"name": "Submit #333777 | www.dlink.com DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333777"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20licenseauthorization.php.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000-40 V31R02B1413C. Affected is an unknown function of the file interface/sysmanage/licenseauthorization.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in D-Link DAR-7000-40 V31R02B1413C entdeckt. Dabei betrifft es einen unbekannter Codeteil der Datei interface/sysmanage/licenseauthorization.php. Dank der Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T05:31:06.328Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264528 | D-Link DAR-7000-40 licenseauthorization.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264528"
},
{
"name": "VDB-264528 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264528"
},
{
"name": "Submit #333777 | www.dlink.com DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333777"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20licenseauthorization.php.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:49.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 licenseauthorization.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4960",
"datePublished": "2024-05-16T05:31:06.328Z",
"dateReserved": "2024-05-15T19:14:38.539Z",
"dateUpdated": "2024-08-01T20:55:10.441Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4965 (GCVE-0-2024-4965)
Vulnerability from nvd – Published: 2024-05-16 07:31 – Updated: 2024-08-08 14:41 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 resmanage.php os command injection
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This issue affects some unknown processing of the file /useratte/resmanage.php. The manipulation of the argument load leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264533 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264533 | D-Link DAR-7000-40 resmanage.php os command injection",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264533"
},
{
"name": "VDB-264533 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264533"
},
{
"name": "Submit #333784 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Command Injection",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333784"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_RCE_%20resmanage.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4965",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T15:12:00.253977Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-08T14:41:28.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This issue affects some unknown processing of the file /useratte/resmanage.php. The manipulation of the argument load leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264533 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in D-Link DAR-7000-40 V31R02B1413C gefunden. Betroffen davon ist ein unbekannter Prozess der Datei /useratte/resmanage.php. Mittels dem Manipulieren des Arguments load mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T07:31:07.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264533 | D-Link DAR-7000-40 resmanage.php os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264533"
},
{
"name": "VDB-264533 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264533"
},
{
"name": "Submit #333784 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333784"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_RCE_%20resmanage.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 resmanage.php os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4965",
"datePublished": "2024-05-16T07:31:07.390Z",
"dateReserved": "2024-05-15T19:14:58.963Z",
"dateUpdated": "2024-08-08T14:41:28.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4964 (GCVE-0-2024-4964)
Vulnerability from nvd – Published: 2024-05-16 07:31 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 urlblist.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This vulnerability affects unknown code of the file /firewall/urlblist.php. The manipulation of the argument file leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264532. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:d-link:dar-7000-40:v31r02b1413c:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "dar-7000-40",
"vendor": "d-link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4964",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-30T18:32:03.976608Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:55:00.322Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264532 | D-Link DAR-7000-40 urlblist.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264532"
},
{
"name": "VDB-264532 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264532"
},
{
"name": "Submit #333783 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333783"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20urlblist.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This vulnerability affects unknown code of the file /firewall/urlblist.php. The manipulation of the argument file leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264532. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "In D-Link DAR-7000-40 V31R02B1413C wurde eine kritische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Datei /firewall/urlblist.php. Durch Manipulation des Arguments file mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T07:31:05.221Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264532 | D-Link DAR-7000-40 urlblist.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264532"
},
{
"name": "VDB-264532 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264532"
},
{
"name": "Submit #333783 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333783"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20urlblist.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 urlblist.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4964",
"datePublished": "2024-05-16T07:31:05.221Z",
"dateReserved": "2024-05-15T19:14:56.124Z",
"dateUpdated": "2024-08-01T20:55:10.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4963 (GCVE-0-2024-4963)
Vulnerability from nvd – Published: 2024-05-16 07:00 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 url.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-7000-40 V31R02B1413C. This affects an unknown part of the file /url/url.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-264531. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T15:18:57.582598Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:56:17.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.367Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264531 | D-Link DAR-7000-40 url.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264531"
},
{
"name": "VDB-264531 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264531"
},
{
"name": "Submit #333781 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333781"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20url.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-7000-40 V31R02B1413C. This affects an unknown part of the file /url/url.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-264531. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in D-Link DAR-7000-40 V31R02B1413C gefunden. Hiervon betroffen ist ein unbekannter Codeblock der Datei /url/url.php. Durch die Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T07:00:05.986Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264531 | D-Link DAR-7000-40 url.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264531"
},
{
"name": "VDB-264531 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264531"
},
{
"name": "Submit #333781 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333781"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20url.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 url.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4963",
"datePublished": "2024-05-16T07:00:05.986Z",
"dateReserved": "2024-05-15T19:14:46.570Z",
"dateUpdated": "2024-08-01T20:55:10.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4962 (GCVE-0-2024-4962)
Vulnerability from nvd – Published: 2024-05-16 06:31 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 resmanage.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000-40 V31R02B1413C. Affected by this issue is some unknown functionality of the file /useratte/resmanage.php. The manipulation of the argument file leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-264530 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:d-link:dar-7000-40:v31r02b1413c:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "dar-7000-40",
"vendor": "d-link",
"versions": [
{
"status": "affected",
"version": "v31r02b1413c"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4962",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T17:31:54.325504Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:56:12.173Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264530 | D-Link DAR-7000-40 resmanage.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264530"
},
{
"name": "VDB-264530 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264530"
},
{
"name": "Submit #333780 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333780"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20resmanage.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000-40 V31R02B1413C. Affected by this issue is some unknown functionality of the file /useratte/resmanage.php. The manipulation of the argument file leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-264530 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in D-Link DAR-7000-40 V31R02B1413C entdeckt. Davon betroffen ist unbekannter Code der Datei /useratte/resmanage.php. Mit der Manipulation des Arguments file mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T06:31:04.878Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264530 | D-Link DAR-7000-40 resmanage.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264530"
},
{
"name": "VDB-264530 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264530"
},
{
"name": "Submit #333780 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333780"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20resmanage.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 resmanage.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4962",
"datePublished": "2024-05-16T06:31:04.878Z",
"dateReserved": "2024-05-15T19:14:43.902Z",
"dateUpdated": "2024-08-01T20:55:10.358Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4961 (GCVE-0-2024-4961)
Vulnerability from nvd – Published: 2024-05-16 06:00 – Updated: 2024-08-23 17:42 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 onlineuser.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-7000-40 V31R02B1413C. Affected by this vulnerability is an unknown functionality of the file /user/onlineuser.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264529 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264529 | D-Link DAR-7000-40 onlineuser.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264529"
},
{
"name": "VDB-264529 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264529"
},
{
"name": "Submit #333779 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333779"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20onlineuser.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4961",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T17:34:15.479200Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T17:42:36.505Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-7000-40 V31R02B1413C. Affected by this vulnerability is an unknown functionality of the file /user/onlineuser.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264529 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "In D-Link DAR-7000-40 V31R02B1413C wurde eine kritische Schwachstelle entdeckt. Hierbei betrifft es unbekannten Programmcode der Datei /user/onlineuser.php. Dank Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T06:00:06.797Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264529 | D-Link DAR-7000-40 onlineuser.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264529"
},
{
"name": "VDB-264529 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264529"
},
{
"name": "Submit #333779 | www.dlink.com D-LINK-DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333779"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20onlineuser.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 onlineuser.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4961",
"datePublished": "2024-05-16T06:00:06.797Z",
"dateReserved": "2024-05-15T19:14:40.952Z",
"dateUpdated": "2024-08-23T17:42:36.505Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4960 (GCVE-0-2024-4960)
Vulnerability from nvd – Published: 2024-05-16 05:31 – Updated: 2024-08-01 20:55 Unsupported When Assigned
VLAI?
Title
D-Link DAR-7000-40 licenseauthorization.php unrestricted upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000-40 V31R02B1413C. Affected is an unknown function of the file interface/sysmanage/licenseauthorization.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-434 - Unrestricted Upload
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| D-Link | DAR-7000-40 |
Affected:
V31R02B1413C
|
Credits
H0e4a0r1t (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4960",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-16T15:14:17.718356Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:53:14.892Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.441Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-264528 | D-Link DAR-7000-40 licenseauthorization.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.264528"
},
{
"name": "VDB-264528 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.264528"
},
{
"name": "Submit #333777 | www.dlink.com DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.333777"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20licenseauthorization.php.php.pdf"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000-40",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "V31R02B1413C"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "H0e4a0r1t (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000-40 V31R02B1413C. Affected is an unknown function of the file interface/sysmanage/licenseauthorization.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-264528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in D-Link DAR-7000-40 V31R02B1413C entdeckt. Dabei betrifft es einen unbekannter Codeteil der Datei interface/sysmanage/licenseauthorization.php. Dank der Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-16T05:31:06.328Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-264528 | D-Link DAR-7000-40 licenseauthorization.php unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.264528"
},
{
"name": "VDB-264528 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.264528"
},
{
"name": "Submit #333777 | www.dlink.com DAR-7000-40 DAR V31R02B1413C Unrestricted Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.333777"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_upload_%20licenseauthorization.php.php.pdf"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-05-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-05-15T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-05-15T21:20:49.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000-40 licenseauthorization.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4960",
"datePublished": "2024-05-16T05:31:06.328Z",
"dateReserved": "2024-05-15T19:14:38.539Z",
"dateUpdated": "2024-08-01T20:55:10.441Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}