Search criteria

4 vulnerabilities found for Dell SmartFabric OS10 by Dell

CVE-2023-32462 (GCVE-0-2023-32462)

Vulnerability from cvelistv5 – Published: 2024-02-15 12:42 – Updated: 2025-04-24 15:14
VLAI?
Summary
Dell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell Dell SmartFabric OS10 Affected: 10.5.5.0
Affected: 10.5.5.3
Affected: 10.5.5.1 (MX)
Affected: 10.5.5.2 (MX)
Affected: 10.5.4.x
Affected: 10.5.4.6 (MX)
Affected: 10.5.3.x
Affected: 10.5.2.x
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32462",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-15T16:56:58.249857Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-24T15:14:27.218Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:18:37.390Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell SmartFabric OS10",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.5.0"
            },
            {
              "status": "affected",
              "version": "10.5.5.3"
            },
            {
              "status": "affected",
              "version": "10.5.5.1 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.5.2 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.4.x"
            },
            {
              "status": "affected",
              "version": "10.5.4.6 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.3.x"
            },
            {
              "status": "affected",
              "version": "10.5.2.x"
            }
          ]
        }
      ],
      "datePublic": "2023-08-08T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-15T12:42:26.610Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-32462",
    "datePublished": "2024-02-15T12:42:26.610Z",
    "dateReserved": "2023-05-09T06:05:24.994Z",
    "dateUpdated": "2025-04-24T15:14:27.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28078 (GCVE-0-2023-28078)

Vulnerability from cvelistv5 – Published: 2024-02-15 12:35 – Updated: 2024-08-15 17:59
VLAI?
Summary
Dell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.
CWE
  • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
Impacted products
Vendor Product Version
Dell Dell SmartFabric OS10 Affected: 10.5.5.0
Affected: 10.5.5.3
Affected: 10.5.5.1 (MX)
Affected: 10.5.5.2 (MX)
Affected: 10.5.4.x
Affected: 10.5.4.6 (MX)
Affected: 10.5.3.x
Affected: 10.5.2.x
Create a notification for this product.
Credits
Rafael Schaefer, ERNW Enno Rey Netzwerke GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:30:24.003Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "smartfabric_os10",
            "vendor": "dell",
            "versions": [
              {
                "status": "affected",
                "version": "10.5.5.0"
              },
              {
                "status": "affected",
                "version": "10.5.5.3"
              },
              {
                "status": "affected",
                "version": "10.5.5.1\\(mx\\)"
              },
              {
                "status": "affected",
                "version": "10.5.5.2\\(mx\\)"
              },
              {
                "lessThan": "10.5.5.0",
                "status": "affected",
                "version": "10.5.2.0",
                "versionType": "custom"
              },
              {
                "status": "affected",
                "version": "10.5.4.6\\(mx\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28078",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-15T19:48:03.918241Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:59:34.409Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell SmartFabric OS10",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.5.0"
            },
            {
              "status": "affected",
              "version": "10.5.5.3"
            },
            {
              "status": "affected",
              "version": "10.5.5.1 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.5.2 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.4.x"
            },
            {
              "status": "affected",
              "version": "10.5.4.6 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.3.x"
            },
            {
              "status": "affected",
              "version": "10.5.2.x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Rafael Schaefer, ERNW Enno Rey Netzwerke GmbH"
        }
      ],
      "datePublic": "2023-08-08T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-923",
              "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-15T12:35:00.259Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-28078",
    "datePublished": "2024-02-15T12:35:00.259Z",
    "dateReserved": "2023-03-10T05:10:02.997Z",
    "dateUpdated": "2024-08-15T17:59:34.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-32462 (GCVE-0-2023-32462)

Vulnerability from nvd – Published: 2024-02-15 12:42 – Updated: 2025-04-24 15:14
VLAI?
Summary
Dell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell Dell SmartFabric OS10 Affected: 10.5.5.0
Affected: 10.5.5.3
Affected: 10.5.5.1 (MX)
Affected: 10.5.5.2 (MX)
Affected: 10.5.4.x
Affected: 10.5.4.6 (MX)
Affected: 10.5.3.x
Affected: 10.5.2.x
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32462",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-15T16:56:58.249857Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-24T15:14:27.218Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:18:37.390Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell SmartFabric OS10",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.5.0"
            },
            {
              "status": "affected",
              "version": "10.5.5.3"
            },
            {
              "status": "affected",
              "version": "10.5.5.1 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.5.2 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.4.x"
            },
            {
              "status": "affected",
              "version": "10.5.4.6 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.3.x"
            },
            {
              "status": "affected",
              "version": "10.5.2.x"
            }
          ]
        }
      ],
      "datePublic": "2023-08-08T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-15T12:42:26.610Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-32462",
    "datePublished": "2024-02-15T12:42:26.610Z",
    "dateReserved": "2023-05-09T06:05:24.994Z",
    "dateUpdated": "2025-04-24T15:14:27.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28078 (GCVE-0-2023-28078)

Vulnerability from nvd – Published: 2024-02-15 12:35 – Updated: 2024-08-15 17:59
VLAI?
Summary
Dell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.
CWE
  • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
Impacted products
Vendor Product Version
Dell Dell SmartFabric OS10 Affected: 10.5.5.0
Affected: 10.5.5.3
Affected: 10.5.5.1 (MX)
Affected: 10.5.5.2 (MX)
Affected: 10.5.4.x
Affected: 10.5.4.6 (MX)
Affected: 10.5.3.x
Affected: 10.5.2.x
Create a notification for this product.
Credits
Rafael Schaefer, ERNW Enno Rey Netzwerke GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:30:24.003Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "smartfabric_os10",
            "vendor": "dell",
            "versions": [
              {
                "status": "affected",
                "version": "10.5.5.0"
              },
              {
                "status": "affected",
                "version": "10.5.5.3"
              },
              {
                "status": "affected",
                "version": "10.5.5.1\\(mx\\)"
              },
              {
                "status": "affected",
                "version": "10.5.5.2\\(mx\\)"
              },
              {
                "lessThan": "10.5.5.0",
                "status": "affected",
                "version": "10.5.2.0",
                "versionType": "custom"
              },
              {
                "status": "affected",
                "version": "10.5.4.6\\(mx\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28078",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-15T19:48:03.918241Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T17:59:34.409Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell SmartFabric OS10",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "10.5.5.0"
            },
            {
              "status": "affected",
              "version": "10.5.5.3"
            },
            {
              "status": "affected",
              "version": "10.5.5.1 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.5.2 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.4.x"
            },
            {
              "status": "affected",
              "version": "10.5.4.6 (MX)"
            },
            {
              "status": "affected",
              "version": "10.5.3.x"
            },
            {
              "status": "affected",
              "version": "10.5.2.x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Rafael Schaefer, ERNW Enno Rey Netzwerke GmbH"
        }
      ],
      "datePublic": "2023-08-08T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-923",
              "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-15T12:35:00.259Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-28078",
    "datePublished": "2024-02-15T12:35:00.259Z",
    "dateReserved": "2023-03-10T05:10:02.997Z",
    "dateUpdated": "2024-08-15T17:59:34.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}