Search criteria

2045 vulnerabilities

CVE-2025-46369 (GCVE-0-2025-46369)

Vulnerability from cvelistv5 – Published: 2025-11-13 19:41 – Updated: 2025-11-14 04:55
VLAI?
Summary
Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation.
CWE
  • CWE-377 - Insecure Temporary File
Assigner
References
Impacted products
Vendor Product Version
Dell Alienware Command Center 6.x (AWCC) Affected: N/A , < 6.10.15.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46369",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-13T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-14T04:55:42.715Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Alienware Command Center 6.x (AWCC)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.10.15.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-13T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation."
            }
          ],
          "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-377",
              "description": "CWE-377: Insecure Temporary File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-13T19:41:56.545Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000379467/dsa-2025-392"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46369",
    "datePublished": "2025-11-13T19:41:56.545Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-11-14T04:55:42.715Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46370 (GCVE-0-2025-46370)

Vulnerability from cvelistv5 – Published: 2025-11-13 19:38 – Updated: 2025-11-13 19:54
VLAI?
Summary
Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain a Process Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information Disclosure.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Alienware Command Center 6.x (AWCC) Affected: N/A , < 6.10.15.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46370",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-13T19:54:36.078090Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T19:54:44.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Alienware Command Center 6.x (AWCC)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.10.15.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-13T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain a Process Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information Disclosure."
            }
          ],
          "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain a Process Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information Disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-114",
              "description": "CWE-114: Process Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-13T19:38:47.751Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000379467/dsa-2025-392"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46370",
    "datePublished": "2025-11-13T19:38:47.751Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-11-13T19:54:44.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46362 (GCVE-0-2025-46362)

Vulnerability from cvelistv5 – Published: 2025-11-13 19:34 – Updated: 2025-11-13 19:42
VLAI?
Summary
Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information Tampering.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Dell Alienware Command Center 6.x (AWCC) Affected: N/A , < 6.10.15.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46362",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-13T19:42:24.264206Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T19:42:43.042Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Alienware Command Center 6.x (AWCC)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.10.15.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-13T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information Tampering."
            }
          ],
          "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information Tampering."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-13T19:34:09.622Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000379467/dsa-2025-392"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46362",
    "datePublished": "2025-11-13T19:34:09.622Z",
    "dateReserved": "2025-04-23T05:03:43.134Z",
    "dateUpdated": "2025-11-13T19:42:43.042Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46368 (GCVE-0-2025-46368)

Vulnerability from cvelistv5 – Published: 2025-11-13 19:30 – Updated: 2025-11-13 19:37
VLAI?
Summary
Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information tampering.
CWE
  • CWE-377 - Insecure Temporary File
Assigner
References
Impacted products
Vendor Product Version
Dell Alienware Command Center 6.x (AWCC) Affected: N/A , < 6.10.15.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46368",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-13T19:37:11.682396Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T19:37:36.389Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Alienware Command Center 6.x (AWCC)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.10.15.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-13T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information tampering."
            }
          ],
          "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information tampering."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-377",
              "description": "CWE-377: Insecure Temporary File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-13T19:30:44.540Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000379467/dsa-2025-392"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46368",
    "datePublished": "2025-11-13T19:30:44.540Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-11-13T19:37:36.389Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46367 (GCVE-0-2025-46367)

Vulnerability from cvelistv5 – Published: 2025-11-13 19:23 – Updated: 2025-12-01 15:36
VLAI?
Summary
Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain a Detection of Error Condition Without Action vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Arbitrary Code Execution.
CWE
  • CWE-390 - Detection of Error Condition Without Action
Assigner
References
Impacted products
Vendor Product Version
Dell Alienware Command Center Affected: N/A , < 6.10.15.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46367",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-14T04:55:42.395255Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-01T15:36:51.818Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Alienware Command Center",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.10.15.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-13T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain a Detection of Error Condition Without Action vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Arbitrary Code Execution."
            }
          ],
          "value": "Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contain a Detection of Error Condition Without Action vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Arbitrary Code Execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-390",
              "description": "CWE-390: Detection of Error Condition Without Action",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-13T19:23:58.335Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000379467/dsa-2025-392"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46367",
    "datePublished": "2025-11-13T19:23:58.335Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-12-01T15:36:51.818Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46608 (GCVE-0-2025-46608)

Vulnerability from cvelistv5 – Published: 2025-11-12 20:12 – Updated: 2025-11-13 21:23
VLAI?
Summary
Dell Data Lakehouse, versions prior to 1.6.0.0, contain(s) an Improper Access Control vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges. This vulnerability is considered Critical, as it may result in unauthorized access with elevated privileges, compromising system integrity and customer data. Dell recommends customers upgrade to the latest version at the earliest opportunity.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Dell Data Lakehouse Affected: N/A , < 1.6.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46608",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-13T21:23:16.451140Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T21:23:27.791Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Data Lakehouse",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.6.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-12T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Data Lakehouse, versions prior to 1.6.0.0, contain(s) an Improper Access Control vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges. This vulnerability is considered Critical, as it may result in unauthorized access with elevated privileges, compromising system integrity and customer data. Dell recommends customers upgrade to the latest version at the earliest opportunity."
            }
          ],
          "value": "Dell Data Lakehouse, versions prior to 1.6.0.0, contain(s) an Improper Access Control vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges. This vulnerability is considered Critical, as it may result in unauthorized access with elevated privileges, compromising system integrity and customer data. Dell recommends customers upgrade to the latest version at the earliest opportunity."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T20:12:59.795Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000390529/dsa-2025-375-security-update-for-dell-data-lakehouse-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46608",
    "datePublished": "2025-11-12T20:12:59.795Z",
    "dateReserved": "2025-04-25T05:03:51.784Z",
    "dateUpdated": "2025-11-13T21:23:27.791Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46427 (GCVE-0-2025-46427)

Vulnerability from cvelistv5 – Published: 2025-11-12 20:01 – Updated: 2025-11-13 04:55
VLAI?
Summary
Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric OS10 Software Affected: N/A , < 10.6.1.0 (semver)
Create a notification for this product.
Credits
Dell would like to thank kkking for reporting these issues.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46427",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T04:55:39.176Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric OS10 Software",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "10.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank kkking for reporting these issues."
        }
      ],
      "datePublic": "2025-11-12T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "value": "Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T20:01:32.594Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000391062/dsa-2025-407-security-update-for-dell-networking-os10-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46427",
    "datePublished": "2025-11-12T20:01:32.594Z",
    "dateReserved": "2025-04-24T05:03:44.662Z",
    "dateUpdated": "2025-11-13T04:55:39.176Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46428 (GCVE-0-2025-46428)

Vulnerability from cvelistv5 – Published: 2025-11-12 19:57 – Updated: 2025-11-13 04:55
VLAI?
Summary
Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric OS10 Software Affected: N/A , < 10.6.1.0 (semver)
Create a notification for this product.
Credits
Dell would like to thank kkking for reporting these issues.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46428",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T04:55:38.406Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric OS10 Software",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "10.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank kkking for reporting these issues."
        }
      ],
      "datePublic": "2025-11-12T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric OS10 Software, versions prior to 10.6.1.0,  contain an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "value": "Dell SmartFabric OS10 Software, versions prior to 10.6.1.0,  contain an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T19:57:04.843Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000391062/dsa-2025-407-security-update-for-dell-networking-os10-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46428",
    "datePublished": "2025-11-12T19:57:04.843Z",
    "dateReserved": "2025-04-24T05:03:44.662Z",
    "dateUpdated": "2025-11-13T04:55:38.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-48829 (GCVE-0-2024-48829)

Vulnerability from cvelistv5 – Published: 2025-11-12 19:50 – Updated: 2025-11-13 04:55
VLAI?
Summary
Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Control of Generation of Code ('Code Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell SmartFabric OS10 Software Affected: N/A , < 10.6.1.0 (semver)
Create a notification for this product.
Credits
Dell would like to thank n3k from TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48829",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-13T04:55:37.698Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SmartFabric OS10 Software",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "10.6.1.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank n3k from TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue."
        }
      ],
      "datePublic": "2025-11-12T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "value": "Dell SmartFabric OS10 Software, versions prior to 10.6.1.0, contain an Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T19:50:02.934Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000391062/dsa-2025-407-security-update-for-dell-networking-os10-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-48829",
    "datePublished": "2025-11-12T19:50:02.934Z",
    "dateReserved": "2024-10-08T16:18:11.122Z",
    "dateUpdated": "2025-11-13T04:55:37.698Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43723 (GCVE-0-2025-43723)

Vulnerability from cvelistv5 – Published: 2025-11-10 19:10 – Updated: 2025-11-10 19:38
VLAI?
Summary
Dell PowerScale OneFS, versions prior to 9.10.1.3 and versions 9.11.0.0 through 9.12.0.0, contains a use of a broken or risky cryptographic algorithm vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell PowerScale OneFS Affected: N/A , < 9.10.1.3 (semver)
Affected: N/A , < 9.12.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43723",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-10T19:38:07.918202Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-10T19:38:29.859Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerScale OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.10.1.3",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "9.12.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-10T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerScale OneFS, versions prior to 9.10.1.3 and versions 9.11.0.0 through 9.12.0.0, contains a use of a broken or risky cryptographic algorithm vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
            }
          ],
          "value": "Dell PowerScale OneFS, versions prior to 9.10.1.3 and versions 9.11.0.0 through 9.12.0.0, contains a use of a broken or risky cryptographic algorithm vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-10T19:10:43.824Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000390206/dsa-2025-381-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43723",
    "datePublished": "2025-11-10T19:10:43.824Z",
    "dateReserved": "2025-04-17T05:03:55.667Z",
    "dateUpdated": "2025-11-10T19:38:29.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46430 (GCVE-0-2025-46430)

Vulnerability from cvelistv5 – Published: 2025-11-10 15:59 – Updated: 2025-11-11 04:55
VLAI?
Summary
Dell Display and Peripheral Manager, versions prior to 2.1.2.12, contains an Execution with Unnecessary Privileges vulnerability in the Installer. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges.
CWE
  • CWE-250 - Execution with Unnecessary Privileges
Assigner
References
Impacted products
Vendor Product Version
Dell Display and Peripheral Manager Affected: N/A , < 2.1.2.12 (semver)
Create a notification for this product.
Credits
Dell Technologies would like to thank Marius Gabriel Mihai for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46430",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-10T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-11T04:55:37.849Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Display and Peripheral Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.1.2.12",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would like to thank Marius Gabriel Mihai for reporting this issue."
        }
      ],
      "datePublic": "2025-11-06T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Display and Peripheral Manager, versions prior to 2.1.2.12, contains an Execution with Unnecessary Privileges vulnerability in the Installer. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges."
            }
          ],
          "value": "Dell Display and Peripheral Manager, versions prior to 2.1.2.12, contains an Execution with Unnecessary Privileges vulnerability in the Installer. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-10T15:59:35.862Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384546/dsa-2025-411"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46430",
    "datePublished": "2025-11-10T15:59:35.862Z",
    "dateReserved": "2025-04-24T05:03:44.662Z",
    "dateUpdated": "2025-11-11T04:55:37.849Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-22397 (GCVE-0-2025-22397)

Vulnerability from cvelistv5 – Published: 2025-11-06 18:46 – Updated: 2025-11-06 19:30
VLAI?
Summary
Dell Integrated Dell Remote Access Controller 9, 14G versions prior to 7.00.00.181, 15G and 16G versions 6.10.80.00 through 7.20.10.50 and Dell Integrated Dell Remote Access Controller 10, 17G versions prior to 1.20.25.00, contain an Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22397",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-06T19:29:27.509712Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T19:30:39.315Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Integrated Dell Remote Access Controller 9 14G Versions",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "7.00.00.181",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Integrated Dell Remote Access Controller 9 15G and 16G versions",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "7.20.10.50",
              "status": "affected",
              "version": "6.10.80.00",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Integrated Dell Remote Access Controller 10 17G version",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.20.25.00",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-11-06T18:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Integrated Dell Remote Access Controller 9, 14G versions prior to 7.00.00.181, 15G and 16G versions 6.10.80.00 through 7.20.10.50 and Dell Integrated Dell Remote Access Controller 10, 17G versions prior to 1.20.25.00, contain an Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
            }
          ],
          "value": "Dell Integrated Dell Remote Access Controller 9, 14G versions prior to 7.00.00.181, 15G and 16G versions 6.10.80.00 through 7.20.10.50 and Dell Integrated Dell Remote Access Controller 10, 17G versions prior to 1.20.25.00, contain an Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-06T18:46:04.736Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384516/dsa-2025-376-security-update-for-dell-idrac9-and-idrac10-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-22397",
    "datePublished": "2025-11-06T18:46:04.736Z",
    "dateReserved": "2025-01-06T13:40:01.387Z",
    "dateUpdated": "2025-11-06T19:30:39.315Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43990 (GCVE-0-2025-43990)

Vulnerability from cvelistv5 – Published: 2025-11-05 17:01 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell Command Monitor (DCM), versions prior to 10.12.3.28, contains an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges.
CWE
  • CWE-250 - Execution with Unnecessary Privileges
Assigner
References
Impacted products
Vendor Product Version
Dell Command Monitor (DCM) Affected: N/A , < 10.12.3.28 (semver)
Create a notification for this product.
Credits
Dell Technologies would like to thank Marius Gabriel Mihai for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43990",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:47.809Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Command Monitor (DCM)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "10.12.3.28",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would like to thank Marius Gabriel Mihai for reporting this issue."
        }
      ],
      "datePublic": "2025-11-05T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Command Monitor (DCM), versions prior to 10.12.3.28, contains an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges."
            }
          ],
          "value": "Dell Command Monitor (DCM), versions prior to 10.12.3.28, contains an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T17:01:23.986Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384947/dsa-2025-414"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43990",
    "datePublished": "2025-11-05T17:01:23.986Z",
    "dateReserved": "2025-04-21T05:03:43.633Z",
    "dateUpdated": "2025-11-06T04:55:47.809Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46366 (GCVE-0-2025-46366)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:50 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information.
CWE
  • CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLink Affected: N/A , < 8.1.1 (semver)
Create a notification for this product.
Credits
Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46366",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:41.794Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLink",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank n3k From TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue."
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information."
            }
          ],
          "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-256",
              "description": "CWE-256: Plaintext Storage of a Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:50:28.754Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46366",
    "datePublished": "2025-11-05T16:50:28.754Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-11-06T04:55:41.794Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46424 (GCVE-0-2025-46424)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:46 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service.
CWE
  • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLink Affected: N/A , < 8.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46424",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:40.938Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLink",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service."
            }
          ],
          "value": "Dell CloudLink, versions prior to 8.2, contain use of a Cryptographic Primitive with a Risky Implementation vulnerability. A high privileged attacker could potentially exploit this vulnerability leading to Denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1240",
              "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:46:25.707Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46424",
    "datePublished": "2025-11-05T16:46:25.707Z",
    "dateReserved": "2025-04-24T05:03:44.662Z",
    "dateUpdated": "2025-11-06T04:55:40.938Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46365 (GCVE-0-2025-46365)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:40 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLink Affected: N/A , < 8.1.1 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46365",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:40.128Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLink",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink."
            }
          ],
          "value": "Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:40:39.934Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46365",
    "datePublished": "2025-11-05T16:40:39.934Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-11-06T04:55:40.128Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46364 (GCVE-0-2025-46364)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:36 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLin Affected: N/A , < 8.1.1 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46364",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:39.277Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLin",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system."
            }
          ],
          "value": "Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user with known password can run CLI Escape Vulnerability to gain control of system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:36:00.347Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46364",
    "datePublished": "2025-11-05T16:36:00.347Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-11-06T04:55:39.277Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-45379 (GCVE-0-2025-45379)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:31 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLink Affected: N/A , < 8.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-45379",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:38.394Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLink",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system."
            }
          ],
          "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection from console to gain shell access of system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:31:57.457Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-45379",
    "datePublished": "2025-11-05T16:31:57.457Z",
    "dateReserved": "2025-04-22T05:03:45.359Z",
    "dateUpdated": "2025-11-06T04:55:38.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-30479 (GCVE-0-2025-30479)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:27 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLink Affected: N/A , < 8.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30479",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:37.459Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLink",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system."
            }
          ],
          "value": "Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:27:33.266Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-30479",
    "datePublished": "2025-11-05T16:27:33.266Z",
    "dateReserved": "2025-03-23T18:45:23.729Z",
    "dateUpdated": "2025-11-06T04:55:37.459Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-45378 (GCVE-0-2025-45378)

Vulnerability from cvelistv5 – Published: 2025-11-05 16:23 – Updated: 2025-11-06 04:55
VLAI?
Summary
Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system. If ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell CloudLink Affected: 8.0 , < 8.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-45378",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-06T04:55:36.592Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CloudLink",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.2",
              "status": "affected",
              "version": "8.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system.\u003cbr\u003e\u003cbr\u003eIf ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password."
            }
          ],
          "value": "Dell CloudLink, versions 8.0 through 8.1.2, contain vulnerability on restricted shell. A Privileged user with known password can break into command shell of CloudLink server and gain access of shell and escalate privilege, gain unauthorized access of system.\n\nIf ssh is enabled with web credentials of server, attack is possible through network with known privileged user/password."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-05T16:23:15.673Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-for-dell-cloudlink-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-45378",
    "datePublished": "2025-11-05T16:23:15.673Z",
    "dateReserved": "2025-04-22T05:03:45.359Z",
    "dateUpdated": "2025-11-06T04:55:36.592Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-36592 (GCVE-0-2025-36592)

Vulnerability from cvelistv5 – Published: 2025-10-30 15:26 – Updated: 2025-10-30 17:37
VLAI?
Summary
Dell Secure Connect Gateway (SCG) Policy Manager, version(s) 5.20. 5.22, 5.24, 5.26, 5.28, contain(s) an Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Script injection.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
Vendor Product Version
Dell Secure Connect Gateway SCG Policy Manager Affected: N/A , < 5.32.00.18 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-36592",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T17:34:40.720083Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-30T17:37:02.064Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Secure Connect Gateway SCG Policy Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.32.00.18",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:secure_connect_gateway_scg_policy_manager:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.32.00.18",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Secure Connect Gateway (SCG) Policy Manager, version(s) 5.20. 5.22, 5.24, 5.26, 5.28, contain(s) an Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Script injection."
            }
          ],
          "value": "Dell Secure Connect Gateway (SCG) Policy Manager, version(s) 5.20. 5.22, 5.24, 5.26, 5.28, contain(s) an Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Script injection."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T15:26:59.326Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385220/dsa-2025-391-security-update-for-dell-secure-connect-gateway-policy-manager-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-36592",
    "datePublished": "2025-10-30T15:26:59.326Z",
    "dateReserved": "2025-04-15T21:31:17.347Z",
    "dateUpdated": "2025-10-30T17:37:02.064Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46363 (GCVE-0-2025-46363)

Vulnerability from cvelistv5 – Published: 2025-10-30 15:22 – Updated: 2025-10-30 16:00
VLAI?
Summary
Dell Secure Connect Gateway (SCG) 5.0 Application and Appliance version(s) 5.26.00.00 - 5.30.00.00, contain a Relative Path Traversal vulnerability in the SCG exposed for an internal collection download REST API (if this REST API is enabled by Admin user from UI). A low privileged attacker with remote access could potentially exploit this vulnerability, leading to allowing relative path traversal to restricted resources.
CWE
  • CWE-23 - Relative Path Traversal
Assigner
References
Impacted products
Credits
Dell would like to thank Ahmed Y. Elmogy for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46363",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T16:00:47.982468Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-30T16:00:58.601Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Secure Connect Gateway SCG 5.0 Application and Appliance",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.32.00",
              "status": "affected",
              "version": "5.26.00",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:secure_connect_gateway_scg_5.0_application_and_appliance:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.32.00",
                  "versionStartIncluding": "5.26.00",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank Ahmed Y. Elmogy for reporting this issue."
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Secure Connect Gateway (SCG) 5.0 Application and Appliance version(s) 5.26.00.00 - 5.30.00.00, contain a Relative Path Traversal vulnerability in the SCG exposed for an internal collection download REST API (if this REST API is enabled by Admin user from UI). A low privileged attacker with remote access could potentially exploit this vulnerability, leading to allowing relative path traversal to restricted resources."
            }
          ],
          "value": "Dell Secure Connect Gateway (SCG) 5.0 Application and Appliance version(s) 5.26.00.00 - 5.30.00.00, contain a Relative Path Traversal vulnerability in the SCG exposed for an internal collection download REST API (if this REST API is enabled by Admin user from UI). A low privileged attacker with remote access could potentially exploit this vulnerability, leading to allowing relative path traversal to restricted resources."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T15:22:43.106Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385239/dsa-2025-386-security-update-for-dell-secure-connect-gateway-rest-api"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46363",
    "datePublished": "2025-10-30T15:22:43.106Z",
    "dateReserved": "2025-04-23T05:03:43.135Z",
    "dateUpdated": "2025-10-30T16:00:58.601Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43942 (GCVE-0-2025-43942)

Vulnerability from cvelistv5 – Published: 2025-10-30 14:23 – Updated: 2025-10-31 03:55
VLAI?
Summary
Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: N/A , < 5.5.2 (semver)
Create a notification for this product.
Credits
Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43942",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-31T03:55:22.772Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:unity:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.2",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges."
            }
          ],
          "value": "Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T14:23:26.312Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385307/dsa-2025-379-security-update-for-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43942",
    "datePublished": "2025-10-30T14:23:26.312Z",
    "dateReserved": "2025-04-20T05:04:01.416Z",
    "dateUpdated": "2025-10-31T03:55:22.772Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46422 (GCVE-0-2025-46422)

Vulnerability from cvelistv5 – Published: 2025-10-30 14:19 – Updated: 2025-10-31 03:55
VLAI?
Summary
Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: N/A , < 5.5.2 (semver)
Create a notification for this product.
Credits
Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46422",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-31T03:55:23.625Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:unity:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.2",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges."
            }
          ],
          "value": "Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T14:19:34.880Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385307/dsa-2025-379-security-update-for-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46422",
    "datePublished": "2025-10-30T14:19:34.880Z",
    "dateReserved": "2025-04-24T05:03:44.661Z",
    "dateUpdated": "2025-10-31T03:55:23.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46423 (GCVE-0-2025-46423)

Vulnerability from cvelistv5 – Published: 2025-10-30 14:14 – Updated: 2025-10-31 03:55
VLAI?
Summary
Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: N/A , < 5.5.2 (semver)
Create a notification for this product.
Credits
Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46423",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-31T03:55:24.553Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:unity:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.2",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges."
            }
          ],
          "value": "Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T14:14:47.745Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385307/dsa-2025-379-security-update-for-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46423",
    "datePublished": "2025-10-30T14:14:47.745Z",
    "dateReserved": "2025-04-24T05:03:44.662Z",
    "dateUpdated": "2025-10-31T03:55:24.553Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43939 (GCVE-0-2025-43939)

Vulnerability from cvelistv5 – Published: 2025-10-30 14:10 – Updated: 2025-10-31 03:55
VLAI?
Summary
Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: N/A , < 5.5.2 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43939",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-31T03:55:21.085Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:unity:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.2",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges."
            }
          ],
          "value": "Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T14:24:39.537Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385307/dsa-2025-379-security-update-for-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43939",
    "datePublished": "2025-10-30T14:10:14.508Z",
    "dateReserved": "2025-04-20T05:04:01.416Z",
    "dateUpdated": "2025-10-31T03:55:21.085Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43940 (GCVE-0-2025-43940)

Vulnerability from cvelistv5 – Published: 2025-10-30 14:05 – Updated: 2025-10-31 03:55
VLAI?
Summary
Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: N/A , < 5.5.2 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43940",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-31T03:55:21.915Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:unity:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.2",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges."
            }
          ],
          "value": "Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T14:05:17.818Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385307/dsa-2025-379-security-update-for-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43940",
    "datePublished": "2025-10-30T14:05:17.818Z",
    "dateReserved": "2025-04-20T05:04:01.416Z",
    "dateUpdated": "2025-10-31T03:55:21.915Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43941 (GCVE-0-2025-43941)

Vulnerability from cvelistv5 – Published: 2025-10-30 13:57 – Updated: 2025-10-31 03:55
VLAI?
Summary
Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary command with root privileges. This vulnerability only affects systems without a valid license install.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: N/A , < 5.5.2 (semver)
Create a notification for this product.
Credits
Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43941",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-30T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-31T03:55:29.572Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:unity:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.2",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank xiaohei from Ubisectech Sirius Team for reporting this issue"
        }
      ],
      "datePublic": "2025-10-29T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary command with root privileges. This vulnerability only affects systems without a valid license install.\u003cbr\u003e"
            }
          ],
          "value": "Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary command with root privileges. This vulnerability only affects systems without a valid license install."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-30T13:57:25.065Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000385307/dsa-2025-379-security-update-for-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43941",
    "datePublished": "2025-10-30T13:57:25.065Z",
    "dateReserved": "2025-04-20T05:04:01.416Z",
    "dateUpdated": "2025-10-31T03:55:29.572Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-46602 (GCVE-0-2025-46602)

Vulnerability from cvelistv5 – Published: 2025-10-27 18:41 – Updated: 2025-10-27 19:30
VLAI?
Summary
Dell SupportAssist OS Recovery, versions prior to 5.5.15.0, contain an Insertion of Sensitive Information into Externally-Accessible File or Directory vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
CWE
  • CWE-538 - Insertion of Sensitive Information into Externally-Accessible File or Directory
Assigner
References
Impacted products
Vendor Product Version
Dell SupportAssist OS Recovery Affected: N/A , < 5.5.15.0 (semver)
Create a notification for this product.
Credits
Dell Technologies would like to thank Marius Gabriel Mihai for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-46602",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-27T19:30:11.498042Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-27T19:30:22.955Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SupportAssist OS Recovery",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.5.15.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:supportassist_os_recovery:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "5.5.15.0",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would like to thank Marius Gabriel Mihai for reporting this issue."
        }
      ],
      "datePublic": "2025-10-27T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell SupportAssist OS Recovery, versions prior to 5.5.15.0, contain an Insertion of Sensitive Information into Externally-Accessible File or Directory vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
            }
          ],
          "value": "Dell SupportAssist OS Recovery, versions prior to 5.5.15.0, contain an Insertion of Sensitive Information into Externally-Accessible File or Directory vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-538",
              "description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-27T18:41:46.258Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000382443/dsa-2025-403"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-46602",
    "datePublished": "2025-10-27T18:41:46.258Z",
    "dateReserved": "2025-04-25T05:03:51.783Z",
    "dateUpdated": "2025-10-27T19:30:22.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43994 (GCVE-0-2025-43994)

Vulnerability from cvelistv5 – Published: 2025-10-24 14:14 – Updated: 2025-10-24 14:44
VLAI?
Summary
Dell Storage Center - Dell Storage Manager, version(s) DSM 20.1.21, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Dell Dell Storage Manager Affected: N/A , < 2020 R1.21 (semver)
Create a notification for this product.
Credits
Dell would like to thank Tenable for reporting the issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43994",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-24T14:44:03.871476Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-24T14:44:14.598Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell Storage Manager",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2020 R1.21",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:dell:dell_storage_manager:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "2020_r1.21",
                  "versionStartIncluding": "n/a",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank Tenable for reporting the issue."
        }
      ],
      "datePublic": "2025-10-24T05:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Storage Center - Dell Storage Manager, version(s) DSM 20.1.21, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
            }
          ],
          "value": "Dell Storage Center - Dell Storage Manager, version(s) DSM 20.1.21, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-24T14:14:41.021Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000382899/dsa-2025-393-security-update-for-storage-center-dell-storage-manager-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.4.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-43994",
    "datePublished": "2025-10-24T14:14:41.021Z",
    "dateReserved": "2025-04-21T05:03:43.636Z",
    "dateUpdated": "2025-10-24T14:44:14.598Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}