All the vulnerabilites related to Siemens AG - Desigo CC
cve-2020-10055
Vulnerability from cvelistv5
Published
2020-08-14 15:24
Modified
2024-08-04 10:50
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-786743.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-20-224-06 | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.784Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786743.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-224-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Desigo CC", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "V4.x" } ] }, { "product": "Desigo CC", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "V3.x" } ] }, { "product": "Desigo CC Compact", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "V4.x" } ] }, { "product": "Desigo CC Compact", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "V3.x" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-08-14T15:24:06", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786743.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-224-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10055", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Desigo CC", "version": { "version_data": [ { "version_value": "V4.x" } ] } }, { "product_name": "Desigo CC", "version": { "version_data": [ { "version_value": "V3.x" } ] } }, { "product_name": "Desigo CC Compact", "version": { "version_data": [ { "version_value": "V4.x" } ] } }, { "product_name": "Desigo CC Compact", "version": { "version_data": [ { "version_value": "V3.x" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-786743.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786743.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-224-06", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-224-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10055", "datePublished": "2020-08-14T15:24:06", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.784Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }