Search criteria
6 vulnerabilities found for EVlink Home Smart by Schneider Electric
CVE-2024-8070 (GCVE-0-2024-8070)
Vulnerability from cvelistv5 – Published: 2024-10-13 19:50 – Updated: 2024-10-14 15:01
VLAI?
Summary
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary
Severity ?
8.5 (High)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EVlink Home Smart |
Affected:
All versions prior to 2.0.6.0.0
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8070",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-14T15:00:55.969942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-14T15:01:07.649Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVlink Home Smart",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions prior to 2.0.6.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Charge",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions prior to 1.13.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test\ncredentials in the firmware binary"
}
],
"value": "CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test\ncredentials in the firmware binary"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-13T19:50:34.117Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-8070",
"datePublished": "2024-10-13T19:50:34.117Z",
"dateReserved": "2024-08-22T05:52:23.415Z",
"dateUpdated": "2024-10-14T15:01:07.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5313 (GCVE-0-2024-5313)
Vulnerability from cvelistv5 – Published: 2024-06-12 12:14 – Updated: 2024-08-01 21:11
VLAI?
Summary
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH
interface over the product network interface. This does not allow to directly exploit the product or
make any unintended operation as the SSH interface access is protected by an authentication
mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts
to perform a potential denial of service attack on the exposed SSH interface.
Severity ?
6.5 (Medium)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EVlink Home Smart |
Affected:
v2.0.4.1.2_131
Affected: v2.0.3.8.2_128 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:evlink_home_smart:2.0.4.1.2_131:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "evlink_home_smart",
"vendor": "schneider-electric",
"versions": [
{
"status": "affected",
"version": "2.0.4.1.2_131"
},
{
"status": "affected",
"version": "2.0.3.8.2_128"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5313",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T14:57:54.307091Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T15:04:51.869Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:11:12.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVlink Home Smart",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v2.0.4.1.2_131"
},
{
"status": "affected",
"version": "v2.0.3.8.2_128"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface.\n\n"
}
],
"value": "CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:14:58.979Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5313",
"datePublished": "2024-06-12T12:14:58.979Z",
"dateReserved": "2024-05-24T08:29:40.058Z",
"dateUpdated": "2024-08-01T21:11:12.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8070 (GCVE-0-2024-8070)
Vulnerability from nvd – Published: 2024-10-13 19:50 – Updated: 2024-10-14 15:01
VLAI?
Summary
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary
Severity ?
8.5 (High)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EVlink Home Smart |
Affected:
All versions prior to 2.0.6.0.0
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8070",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-14T15:00:55.969942Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-14T15:01:07.649Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVlink Home Smart",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions prior to 2.0.6.0.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Charge",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions prior to 1.13.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test\ncredentials in the firmware binary"
}
],
"value": "CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test\ncredentials in the firmware binary"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-13T19:50:34.117Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-8070",
"datePublished": "2024-10-13T19:50:34.117Z",
"dateReserved": "2024-08-22T05:52:23.415Z",
"dateUpdated": "2024-10-14T15:01:07.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5313 (GCVE-0-2024-5313)
Vulnerability from nvd – Published: 2024-06-12 12:14 – Updated: 2024-08-01 21:11
VLAI?
Summary
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH
interface over the product network interface. This does not allow to directly exploit the product or
make any unintended operation as the SSH interface access is protected by an authentication
mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts
to perform a potential denial of service attack on the exposed SSH interface.
Severity ?
6.5 (Medium)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EVlink Home Smart |
Affected:
v2.0.4.1.2_131
Affected: v2.0.3.8.2_128 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:evlink_home_smart:2.0.4.1.2_131:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "evlink_home_smart",
"vendor": "schneider-electric",
"versions": [
{
"status": "affected",
"version": "2.0.4.1.2_131"
},
{
"status": "affected",
"version": "2.0.3.8.2_128"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5313",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T14:57:54.307091Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T15:04:51.869Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:11:12.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVlink Home Smart",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v2.0.4.1.2_131"
},
{
"status": "affected",
"version": "v2.0.3.8.2_128"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface.\n\n"
}
],
"value": "CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:14:58.979Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5313",
"datePublished": "2024-06-12T12:14:58.979Z",
"dateReserved": "2024-05-24T08:29:40.058Z",
"dateUpdated": "2024-08-01T21:11:12.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CERTFR-2024-AVI-0476
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
Impacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | Sage 2400 | Sage 2400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions | ||
| Schneider Electric | Sage 1450 | Sage 1450 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1430 | Sage 1430 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 3030 Magnum | Sage 3030 Magnum avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1410 | Sage 1410 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | EVlink Home Smart | EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 antérieures à 2.0.5.0.0_134 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | ||
| Schneider Electric | Modicon M340 | Modicon M340 toutes versions | ||
| Schneider Electric | PowerLogic P5 | PowerLogic P5 versions antérieures à 02.501.101 | ||
| Schneider Electric | Sage 4400 | Sage 4400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | N/A | SpaceLogic AS-P et SpaceLogic AS-B versions antérieures à 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de sécurité | ||
| Schneider Electric | Network module, Modicon M340, Modbus/TCP BMXNOE0100 | Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions |
References
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Sage 2400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 2400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1450 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1450",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1430 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1430",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 3030 Magnum avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 3030 Magnum",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1410 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1410",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 ant\u00e9rieures \u00e0 2.0.5.0.0_134",
"product": {
"name": "EVlink Home Smart",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PowerLogic P5 versions ant\u00e9rieures \u00e0 02.501.101",
"product": {
"name": "PowerLogic P5",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 4400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 4400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic AS-P et SpaceLogic AS-B versions ant\u00e9rieures \u00e0 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions",
"product": {
"name": "Network module, Modicon M340, Modbus/TCP BMXNOE0100",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-5557",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5557"
},
{
"name": "CVE-2024-37039",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37039"
},
{
"name": "CVE-2024-5558",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5558"
},
{
"name": "CVE-2024-5056",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5056"
},
{
"name": "CVE-2024-37037",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37037"
},
{
"name": "CVE-2024-5559",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5559"
},
{
"name": "CVE-2024-5313",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5313"
},
{
"name": "CVE-2024-37038",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37038"
},
{
"name": "CVE-2024-37040",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37040"
},
{
"name": "CVE-2024-5560",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5560"
},
{
"name": "CVE-2024-37036",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37036"
}
],
"links": [],
"reference": "CERTFR-2024-AVI-0476",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-06-11T00:00:00.000000"
},
{
"description": "Ajout des identifiants CVE.",
"revision_date": "2024-06-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
]
}