CVE-2025-11567 (GCVE-0-2025-11567)
Vulnerability from cvelistv5 – Published: 2025-11-12 13:27 – Updated: 2025-11-12 18:50
VLAI?
Summary
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
Severity ?
CWE
- CWE-276 - Incorrect Default Permissions
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions v1.3 and prior
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-11567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:03:16.647582Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:04:25.508Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions v1.3 and prior",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-11-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.\u003cbr\u003e"
}
],
"value": "CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T18:50:03.699Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-315-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-11567",
"datePublished": "2025-11-12T13:27:56.004Z",
"dateReserved": "2025-10-09T15:17:30.858Z",
"dateUpdated": "2025-11-12T18:50:03.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-11566 (GCVE-0-2025-11566)
Vulnerability from cvelistv5 – Published: 2025-11-12 13:26 – Updated: 2025-11-12 18:46
VLAI?
Summary
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
Severity ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions v1.3 and prior
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-11566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:07:35.655696Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:07:43.578Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions v1.3 and prior",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-11-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.\u003cbr\u003e"
}
],
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T18:46:45.992Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-315-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-11566",
"datePublished": "2025-11-12T13:26:14.702Z",
"dateReserved": "2025-10-09T15:11:52.000Z",
"dateUpdated": "2025-11-12T18:46:45.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-11565 (GCVE-0-2025-11565)
Vulnerability from cvelistv5 – Published: 2025-11-12 13:19 – Updated: 2025-11-12 18:45
VLAI?
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
Severity ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions v1.3 and prior
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-11565",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-12T14:09:55.180457Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T14:10:03.775Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions v1.3 and prior",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-11-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload."
}
],
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-12T18:45:10.615Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-315-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-11565",
"datePublished": "2025-11-12T13:19:55.722Z",
"dateReserved": "2025-10-09T15:10:36.405Z",
"dateUpdated": "2025-11-12T18:45:10.615Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-9997 (GCVE-0-2025-9997)
Vulnerability from cvelistv5 – Published: 2025-09-09 21:12 – Updated: 2025-09-10 19:34
VLAI?
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
Severity ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Saitel DR RTU |
Affected:
all versions , ≤ 11.06.29
(version)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9997",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-10T19:34:13.130524Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T19:34:21.734Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Saitel DR RTU",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "11.06.29",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Saitel DP RTU",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "11.06.33",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"datePublic": "2025-09-09T04:01:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session."
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T21:12:35.969Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-9997",
"datePublished": "2025-09-09T21:12:35.969Z",
"dateReserved": "2025-09-04T16:16:04.091Z",
"dateUpdated": "2025-09-10T19:34:21.734Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9996 (GCVE-0-2025-9996)
Vulnerability from cvelistv5 – Published: 2025-09-09 21:11 – Updated: 2025-09-10 20:26
VLAI?
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session.
Severity ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Saitel DR RTU |
Affected:
all versions , ≤ 11.06.29
(version)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9996",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-10T20:26:36.121564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T20:26:45.764Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Saitel DR RTU",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "11.06.29",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Saitel DP RTU",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "11.06.33",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"datePublic": "2025-09-09T04:01:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session."
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T21:11:15.034Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-9996",
"datePublished": "2025-09-09T21:11:15.034Z",
"dateReserved": "2025-09-04T16:16:03.592Z",
"dateUpdated": "2025-09-10T20:26:45.764Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7746 (GCVE-0-2025-7746)
Vulnerability from cvelistv5 – Published: 2025-09-09 21:02 – Updated: 2025-11-03 18:14
VLAI?
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives |
Affected:
all versions
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-10T13:40:20.821038Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T16:10:34.376Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T18:14:06.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Sep/69"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC992 InterLink Converter",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV340E Altivar Machine Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV6000 Medium Voltage Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATS490 Altivar Soft Starter",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VW3A3530D: ATVdPAC module",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v25.0",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"datePublic": "2025-09-09T04:01:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
}
],
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T21:02:08.936Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-7746",
"datePublished": "2025-09-09T21:02:08.936Z",
"dateReserved": "2025-07-17T09:10:51.541Z",
"dateUpdated": "2025-11-03T18:14:06.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-8448 (GCVE-0-2025-8448)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:58 – Updated: 2025-09-09 20:55
VLAI?
Summary
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Eelctric | EcoStruxure Building Operation Enterprise Server |
Affected:
All 7.x versions , < 7.0.2.348
(version)
Affected: All 6.x versions , < 6.0.4.10001 (CP8) (version) Affected: All 5.x versions , < 5.0.3.17009 (CP16) (version) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8448",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T15:51:48.499459Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T15:51:53.932Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Building Operation Enterprise Server",
"vendor": "Schneider Eelctric",
"versions": [
{
"lessThan": "7.0.2.348",
"status": "affected",
"version": "All 7.x versions",
"versionType": "version"
},
{
"lessThan": "6.0.4.10001 (CP8)",
"status": "affected",
"version": "All 6.x versions",
"versionType": "version"
},
{
"lessThan": "5.0.3.17009 (CP16)",
"status": "affected",
"version": "All 5.x versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Enterprise Server",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "7.0.2.348",
"status": "affected",
"version": "All 7.x versions",
"versionType": "version"
},
{
"lessThan": "6.0.4.10001 (CP8)",
"status": "affected",
"version": "All 6.x versions",
"versionType": "version"
},
{
"lessThan": "5.0.3.17009 (CP16)",
"status": "affected",
"version": "All 5.x versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Building Operation Workstation",
"vendor": "Schneider Eelctric",
"versions": [
{
"lessThan": "7.0.2.348",
"status": "affected",
"version": "All 7.x versions",
"versionType": "version"
},
{
"lessThan": "6.0.4.10001 (CP8)",
"status": "affected",
"version": "All 6.x versions",
"versionType": "version"
},
{
"lessThan": "5.0.3.17009 (CP16)",
"status": "affected",
"version": "All 5.x versions",
"versionType": "version"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products."
}
],
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 1,
"baseSeverity": "LOW",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T20:55:43.384Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-8448",
"datePublished": "2025-08-20T13:58:53.818Z",
"dateReserved": "2025-07-31T21:02:43.599Z",
"dateUpdated": "2025-09-09T20:55:43.384Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-8449 (GCVE-0-2025-8449)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:55 – Updated: 2025-09-09 20:50
VLAI?
Summary
CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schnieder Electric | EcoStruxure Building Operation Enterprise Server |
Affected:
All 7.x versions , < 7.0.2.348
(version)
Unaffected: All 6.x versions , < 6.0.4.10001 (CP8) (version) Affected: All 5.x versions , < 5.0.3.17009 (CP16) (version) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8449",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T17:10:39.552635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T17:10:46.681Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Building Operation Enterprise Server",
"vendor": "Schnieder Electric",
"versions": [
{
"lessThan": "7.0.2.348",
"status": "affected",
"version": "All 7.x versions",
"versionType": "version"
},
{
"lessThan": "6.0.4.10001 (CP8)",
"status": "unaffected",
"version": "All 6.x versions",
"versionType": "version"
},
{
"lessThan": "5.0.3.17009 (CP16)",
"status": "affected",
"version": "All 5.x versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Enterprise Server",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "7.0.2.348",
"status": "unaffected",
"version": "All 7.x versions",
"versionType": "version"
},
{
"lessThan": "6.0.4.10001 (CP8)",
"status": "affected",
"version": "All 6.x versions",
"versionType": "version"
},
{
"lessThan": "5.0.3.17009 (CP16)",
"status": "affected",
"version": "All 5.x versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Building Operation Workstation",
"vendor": "Schneider Eelctric",
"versions": [
{
"lessThan": "7.0.2.348",
"status": "affected",
"version": "All 7.x versions",
"versionType": "version"
},
{
"lessThan": "6.0.4.10001 (CP8)",
"status": "affected",
"version": "All 6.x versions",
"versionType": "version"
},
{
"lessThan": "5.0.3.17009 (CP16)",
"status": "affected",
"version": "All 5.x versions",
"versionType": "version"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network."
}
],
"value": "CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T20:50:55.766Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-8449",
"datePublished": "2025-08-20T13:55:34.397Z",
"dateReserved": "2025-07-31T21:02:44.262Z",
"dateUpdated": "2025-09-09T20:50:55.766Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54927 (GCVE-0-2025-54927)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:51 – Updated: 2025-08-20 17:21
VLAI?
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.
Severity ?
4.9 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Affected:
Version 2022
Affected: Version 2023 Affected: Version 2024 Affected: Version 2024 R2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54927",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T17:21:22.824724Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T17:21:29.791Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022"
},
{
"status": "affected",
"version": "Version 2023"
},
{
"status": "affected",
"version": "Version 2024"
},
{
"status": "affected",
"version": "Version 2024 R2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022 w/ Advanced Reporting Module"
},
{
"status": "affected",
"version": "Version 2024 w/ Advanced Reporting Module"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system."
}
],
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T13:51:04.959Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-54927",
"datePublished": "2025-08-20T13:51:04.959Z",
"dateReserved": "2025-08-01T04:38:47.036Z",
"dateUpdated": "2025-08-20T17:21:29.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54926 (GCVE-0-2025-54926)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:48 – Updated: 2025-08-20 17:21
VLAI?
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.
Severity ?
7.2 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Affected:
Version 2022
Affected: Version 2023 Affected: Version 2024 Affected: Version 2024 R2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54926",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T17:21:43.158876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T17:21:50.700Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022"
},
{
"status": "affected",
"version": "Version 2023"
},
{
"status": "affected",
"version": "Version 2024"
},
{
"status": "affected",
"version": "Version 2024 R2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022 w/ Advanced Reporting Module"
},
{
"status": "affected",
"version": "Version 2024 w/ Advanced Reporting Module"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed."
}
],
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T13:48:02.393Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-54926",
"datePublished": "2025-08-20T13:48:02.393Z",
"dateReserved": "2025-08-01T04:38:47.036Z",
"dateUpdated": "2025-08-20T17:21:50.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54925 (GCVE-0-2025-54925)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:44 – Updated: 2025-08-20 17:22
VLAI?
Summary
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.
Severity ?
7.5 (High)
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Affected:
Version 2022
Affected: Version 2023 Affected: Version 2024 Affected: Version 2024 R2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54925",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T17:22:07.997830Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T17:22:14.962Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022"
},
{
"status": "affected",
"version": "Version 2023"
},
{
"status": "affected",
"version": "Version 2024"
},
{
"status": "affected",
"version": "Version 2024 R2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022 w/ Advanced Reporting Module"
},
{
"status": "affected",
"version": "Version 2024 w/ Advanced Reporting Module"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url."
}
],
"value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T13:44:21.662Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-54925",
"datePublished": "2025-08-20T13:44:21.662Z",
"dateReserved": "2025-08-01T04:38:47.036Z",
"dateUpdated": "2025-08-20T17:22:14.962Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54924 (GCVE-0-2025-54924)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:39 – Updated: 2025-08-20 17:22
VLAI?
Summary
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.
Severity ?
7.5 (High)
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Affected:
Version 2022
Affected: Version 2023 Affected: Version 2024 Affected: Version 2024 R2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54924",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T17:22:28.618615Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T17:22:38.019Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022"
},
{
"status": "affected",
"version": "Version 2023"
},
{
"status": "affected",
"version": "Version 2024"
},
{
"status": "affected",
"version": "Version 2024 R2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022 w/ Advanced Reporting Module"
},
{
"status": "affected",
"version": "Version 2024 w/ Advanced Reporting Module"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint."
}
],
"value": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T13:44:53.863Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-54924",
"datePublished": "2025-08-20T13:39:10.986Z",
"dateReserved": "2025-08-01T04:38:47.036Z",
"dateUpdated": "2025-08-20T17:22:38.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54923 (GCVE-0-2025-54923)
Vulnerability from cvelistv5 – Published: 2025-08-20 13:30 – Updated: 2025-08-20 17:23
VLAI?
Summary
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.
Severity ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert (PME) |
Affected:
Version 2022
Affected: Version 2023 Affected: Version 2024 Affected: Version 2024 R2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54923",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T17:22:56.459372Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T17:23:04.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022"
},
{
"status": "affected",
"version": "Version 2023"
},
{
"status": "affected",
"version": "Version 2024"
},
{
"status": "affected",
"version": "Version 2024 R2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022 w/ Advanced Reporting Module"
},
{
"status": "affected",
"version": "Version 2024 w/ Advanced Reporting Module"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization."
}
],
"value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T13:44:42.905Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-54923",
"datePublished": "2025-08-20T13:30:04.988Z",
"dateReserved": "2025-08-01T04:38:47.036Z",
"dateUpdated": "2025-08-20T17:23:04.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-8453 (GCVE-0-2025-8453)
Vulnerability from cvelistv5 – Published: 2025-08-20 12:52 – Updated: 2025-08-20 15:11
VLAI?
Summary
CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and
arbitrary code execution when a privileged engineer user with console access modifies a configuration file
used by a root-level daemon to execute custom scripts.
Severity ?
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Saitel DR RTU |
Affected:
Versions 11.06.29 and prior
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-20T15:11:19.603671Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T15:11:28.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Saitel DR RTU",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 11.06.29 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Saitel DP RTU",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 11.06.34 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and\narbitrary code execution when a privileged engineer user with console access modifies a configuration file\nused by a root-level daemon to execute custom scripts.\n\n\u003cbr\u003e"
}
],
"value": "CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and\narbitrary code execution when a privileged engineer user with console access modifies a configuration file\nused by a root-level daemon to execute custom scripts."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T12:52:50.191Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-8453",
"datePublished": "2025-08-20T12:52:50.191Z",
"dateReserved": "2025-08-01T02:45:24.698Z",
"dateUpdated": "2025-08-20T15:11:28.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5296 (GCVE-0-2025-5296)
Vulnerability from cvelistv5 – Published: 2025-08-18 07:22 – Updated: 2025-08-18 12:22
VLAI?
Summary
CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause
arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file
corruption, exposure of application and system information or persistent denial of service when a low-privileged
attacker tampers with the installation folder.
Severity ?
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | SESU |
Affected:
Versions prior to v3.0.12
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5296",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-18T12:22:15.242244Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-18T12:22:22.123Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SESU",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v3.0.12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027) vulnerability exists that could cause \narbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file \ncorruption, exposure of application and system information or persistent denial of service when a low-privileged \nattacker tampers with the installation folder.\n\n\u003cbr\u003e"
}
],
"value": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027) vulnerability exists that could cause \narbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file \ncorruption, exposure of application and system information or persistent denial of service when a low-privileged \nattacker tampers with the installation folder."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-18T07:22:05.013Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-5296",
"datePublished": "2025-08-18T07:22:05.013Z",
"dateReserved": "2025-05-28T06:06:42.804Z",
"dateUpdated": "2025-08-18T12:22:22.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6625 (GCVE-0-2025-6625)
Vulnerability from cvelistv5 – Published: 2025-08-18 06:58 – Updated: 2025-08-18 12:22
VLAI?
Summary
CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific
crafted FTP command is sent to the device.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M340 |
Affected:
All versions
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6625",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-18T12:22:44.912415Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-18T12:22:54.996Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMXNOR0200H: Ethernet / Serial RTU Module",
"vendor": "Schneider ELectric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMXNGD0100: M580 Global Data module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMXNOC0401: Modicon M340 X80 Ethernet Communication modules",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 3.60"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMXNOE0110: Modbus/TCP Ethernet Modicon M340 FactoryCast module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 6.80"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific\ncrafted FTP command is sent to the device.\n\n\u003cbr\u003e"
}
],
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific\ncrafted FTP command is sent to the device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-18T06:58:15.222Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-6625",
"datePublished": "2025-08-18T06:58:15.222Z",
"dateReserved": "2025-06-25T10:08:00.547Z",
"dateUpdated": "2025-08-18T12:22:54.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6788 (GCVE-0-2025-6788)
Vulnerability from cvelistv5 – Published: 2025-07-11 11:09 – Updated: 2025-07-22 15:16
VLAI?
Summary
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources
to the wrong control sphere, providing other authenticated users with potentially inappropriate access to TGML
diagrams.
Severity ?
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ Power Monitoring Expert |
Affected:
2023 , < All
(custom)
Affected: 2023 R2 , < All (custom) Affected: 2024 , < All (custom) Affected: 2024 R2 , < All (custom) |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6788",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-22T15:16:21.254303Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-22T15:16:30.986Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Monitoring Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "All",
"status": "affected",
"version": "2023",
"versionType": "custom"
},
{
"lessThan": "All",
"status": "affected",
"version": "2023 R2",
"versionType": "custom"
},
{
"lessThan": "All",
"status": "affected",
"version": "2024",
"versionType": "custom"
},
{
"lessThan": "All",
"status": "affected",
"version": "2024 R2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 Power Operation Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "All",
"status": "affected",
"version": "2022 w/ Advanced Reporting Module",
"versionType": "custom"
},
{
"lessThan": "All",
"status": "affected",
"version": "2024 w/ Advanced Reporting Module",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources\nto the wrong control sphere, providing other authenticated users with potentially inappropriate access to TGML\ndiagrams."
}
],
"value": "A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources\nto the wrong control sphere, providing other authenticated users with potentially inappropriate access to TGML\ndiagrams."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:18:24.544Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-6788",
"datePublished": "2025-07-11T11:09:35.038Z",
"dateReserved": "2025-06-27T12:59:12.591Z",
"dateUpdated": "2025-07-22T15:16:30.986Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-50124 (GCVE-0-2025-50124)
Vulnerability from cvelistv5 – Published: 2025-07-11 10:49 – Updated: 2025-11-03 20:05
VLAI?
Summary
A
CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the
server is accessed by a privileged account via a console and through exploitation of a setup script.
Severity ?
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-50124",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T11:47:58.165036Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T11:48:06.675Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:05:39.428Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/9"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\n\n\n\n\n\nCWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the\nserver is accessed by a privileged account via a console and through exploitation of a setup script."
}
],
"value": "A\n\n\n\n\n\nCWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the\nserver is accessed by a privileged account via a console and through exploitation of a setup script."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:34:52.371Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-50124",
"datePublished": "2025-07-11T10:49:05.761Z",
"dateReserved": "2025-06-12T13:53:23.603Z",
"dateUpdated": "2025-11-03T20:05:39.428Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-50125 (GCVE-0-2025-50125)
Vulnerability from cvelistv5 – Published: 2025-07-11 10:45 – Updated: 2025-11-03 20:05
VLAI?
Summary
A
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote
code execution when the server is accessed via the network with knowledge of hidden URLs and manipulation
of host request header.
Severity ?
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-50125",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T11:48:23.707467Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T11:50:16.061Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:05:40.847Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/10"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\n\n\n\nCWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote\ncode execution when the server is accessed via the network with knowledge of hidden URLs and manipulation\nof host request header."
}
],
"value": "A\n\n\n\nCWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote\ncode execution when the server is accessed via the network with knowledge of hidden URLs and manipulation\nof host request header."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:33:43.906Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-50125",
"datePublished": "2025-07-11T10:45:49.286Z",
"dateReserved": "2025-06-12T13:53:23.603Z",
"dateUpdated": "2025-11-03T20:05:40.847Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-50123 (GCVE-0-2025-50123)
Vulnerability from cvelistv5 – Published: 2025-07-11 10:08 – Updated: 2025-11-04 22:06
VLAI?
Summary
A
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote
command execution by a privileged account when the server is accessed via a console and through
exploitation of the hostname input.
Severity ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-50123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T11:50:32.196693Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T11:50:39.863Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T22:06:41.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/9"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/8"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\n\nCWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that could cause remote\ncommand execution by a privileged account when the server is accessed via a console and through\nexploitation of the hostname input."
}
],
"value": "A\n\nCWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that could cause remote\ncommand execution by a privileged account when the server is accessed via a console and through\nexploitation of the hostname input."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:31:33.214Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-50123",
"datePublished": "2025-07-11T10:08:36.560Z",
"dateReserved": "2025-06-12T13:53:23.603Z",
"dateUpdated": "2025-11-04T22:06:41.379Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-50122 (GCVE-0-2025-50122)
Vulnerability from cvelistv5 – Published: 2025-07-11 09:17 – Updated: 2025-11-03 20:05
VLAI?
Summary
A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the
password generation algorithm is reverse engineered with access to installation or upgrade artifacts.
Severity ?
CWE
- CWE-331 - Insufficient Entropy
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-50122",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T15:08:21.649572Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T15:08:35.117Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:05:36.663Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/7"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\u0026nbsp;CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts."
}
],
"value": "A\u00a0CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.9,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-331",
"description": "CWE-331 Insufficient Entropy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:30:21.080Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-50122",
"datePublished": "2025-07-11T09:17:19.014Z",
"dateReserved": "2025-06-12T13:53:23.603Z",
"dateUpdated": "2025-11-03T20:05:36.663Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-50121 (GCVE-0-2025-50121)
Vulnerability from cvelistv5 – Published: 2025-07-11 09:14 – Updated: 2025-11-03 20:05
VLAI?
Summary
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created
over the web interface HTTP when enabled. HTTP is disabled by default.
Severity ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-50121",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T15:09:11.955744Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T15:15:05.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:05:35.286Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/6"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\u0026nbsp;CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default."
}
],
"value": "A\u00a0CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.5,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:28:32.348Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-50121",
"datePublished": "2025-07-11T09:14:55.415Z",
"dateReserved": "2025-06-12T13:53:23.602Z",
"dateUpdated": "2025-11-03T20:05:35.286Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-6438 (GCVE-0-2025-6438)
Vulnerability from cvelistv5 – Published: 2025-07-11 09:06 – Updated: 2025-11-03 20:07
VLAI?
Summary
A
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could
cause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access
when the server is accessed via the network using an application account.
Severity ?
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6438",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T15:17:38.864784Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T15:17:50.655Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:07:07.439Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/5"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\n\n\n\n\n\n\n\nCWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could\ncause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access\nwhen the server is accessed via the network using an application account."
}
],
"value": "A\n\n\n\n\n\n\n\nCWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could\ncause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access\nwhen the server is accessed via the network using an application account."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611 Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:36:18.162Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-6438",
"datePublished": "2025-07-11T09:06:32.411Z",
"dateReserved": "2025-06-20T16:34:22.051Z",
"dateUpdated": "2025-11-03T20:07:07.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-3117 (GCVE-0-2025-3117)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:43 – Updated: 2025-06-10 14:19
VLAI?
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability
exists impacting configuration file paths that could cause an unvalidated data injected by authenticated
malicious user leading to modify or read data in a victim’s browser.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon Controllers M241/M251 |
Affected:
Versions prior to 5.3.12.51
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3117",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:18:58.354272Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:19:52.530Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241/M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.12.51"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M262",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.9.18"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability\nexists impacting configuration file paths that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim\u2019s browser.\n\n\u003cbr\u003e"
}
],
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability\nexists impacting configuration file paths that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim\u2019s browser."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T08:43:15.540Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-3117",
"datePublished": "2025-06-10T08:43:15.540Z",
"dateReserved": "2025-04-02T12:30:28.927Z",
"dateUpdated": "2025-06-10T14:19:52.530Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3116 (GCVE-0-2025-3116)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:34 – Updated: 2025-06-10 14:21
VLAI?
Summary
CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an
authenticated malicious user sends special malformed HTTPS request containing improper formatted body
data to the controller.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon Controllers M241/M251 |
Affected:
Versions prior to 5.3.12.51
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3116",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:21:17.775474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:21:34.597Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241/M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.12.51"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M258 / LMC058",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an\nauthenticated malicious user sends special malformed HTTPS request containing improper formatted body\ndata to the controller. \n\n\n\u003cbr\u003e"
}
],
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an\nauthenticated malicious user sends special malformed HTTPS request containing improper formatted body\ndata to the controller."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T08:34:50.585Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-3116",
"datePublished": "2025-06-10T08:34:50.585Z",
"dateReserved": "2025-04-02T12:26:30.918Z",
"dateUpdated": "2025-06-10T14:21:34.597Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3905 (GCVE-0-2025-3905)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:32 – Updated: 2025-06-10 14:23
VLAI?
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability
exists impacting PLC system variables that could cause an unvalidated data injected by authenticated
malicious user leading to modify or read data in a victim’s browser.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon Controllers M241/M251 |
Affected:
Versions prior to 5.3.12.51
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3905",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:22:01.269687Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:23:25.411Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241/M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.12.51"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M258 / LMC058",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability\nexists impacting PLC system variables that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim\u2019s browser.\n\n\u003cbr\u003e"
}
],
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability\nexists impacting PLC system variables that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim\u2019s browser."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T08:32:09.065Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-3905",
"datePublished": "2025-06-10T08:32:09.065Z",
"dateReserved": "2025-04-23T16:29:08.918Z",
"dateUpdated": "2025-06-10T14:23:25.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3112 (GCVE-0-2025-3112)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:28 – Updated: 2025-06-10 14:24
VLAI?
Summary
CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause Denial of Service when an
authenticated malicious user sends manipulated HTTPS Content-Length header to the webserver.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Modicon Controllers M241/M251 |
Affected:
Versions prior to 5.3.12.51
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3112",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:24:24.900130Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:24:46.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241/M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.12.51"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause Denial of Service when an\nauthenticated malicious user sends manipulated HTTPS Content-Length header to the webserver.\n\n\n\n \n\n\u003cbr\u003e"
}
],
"value": "CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause Denial of Service when an\nauthenticated malicious user sends manipulated HTTPS Content-Length header to the webserver."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T08:28:31.391Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-3112",
"datePublished": "2025-06-10T08:28:31.391Z",
"dateReserved": "2025-04-02T09:53:20.251Z",
"dateUpdated": "2025-06-10T14:24:46.175Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3899 (GCVE-0-2025-3899)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:25 – Updated: 2025-06-10 14:33
VLAI?
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability
exists in Certificates page on Webserver that could cause an unvalidated data injected by authenticated
malicious user leading to modify or read data in a victim’s browser.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Modicon Controllers M241/M251 |
Affected:
Versions prior to 5.3.12.51
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3899",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:33:48.153732Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:33:59.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241/M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.12.51"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability\nexists in Certificates page on Webserver that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim\u2019s browser.\n\n \n\n\u003cbr\u003e"
}
],
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability\nexists in Certificates page on Webserver that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim\u2019s browser."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T08:25:39.254Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-3899",
"datePublished": "2025-06-10T08:25:39.254Z",
"dateReserved": "2025-04-23T16:26:46.063Z",
"dateUpdated": "2025-06-10T14:33:59.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3898 (GCVE-0-2025-3898)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:22 – Updated: 2025-06-10 14:35
VLAI?
Summary
CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an
authenticated malicious user sends HTTPS request containing invalid data type to the webserver.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon Controllers M241/M251 |
Affected:
Versions prior to 5.3.12.51
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3898",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:34:56.615547Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:35:45.654Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M241/M251",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.12.51"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Controllers M262",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.3.9.18"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an\nauthenticated malicious user sends HTTPS request containing invalid data type to the webserver. \n\n\u003cbr\u003e"
}
],
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an\nauthenticated malicious user sends HTTPS request containing invalid data type to the webserver."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T08:22:02.228Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-3898",
"datePublished": "2025-06-10T08:22:02.228Z",
"dateReserved": "2025-04-23T16:25:08.364Z",
"dateUpdated": "2025-06-10T14:35:45.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5743 (GCVE-0-2025-5743)
Vulnerability from cvelistv5 – Published: 2025-06-10 08:15 – Updated: 2025-10-07 03:29
VLAI?
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulnerability exists that could cause remote control over the charging station when an authenticated user
modifies configuration parameters on the web server.
Severity ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EVLink WallBox |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5743",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T13:07:47.251060Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T13:07:58.480Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVLink WallBox",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause remote control over the charging station when an authenticated user\nmodifies configuration parameters on the web server.\n\n\u003cbr\u003e"
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause remote control over the charging station when an authenticated user\nmodifies configuration parameters on the web server."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T03:29:00.117Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-161-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-5743",
"datePublished": "2025-06-10T08:15:42.268Z",
"dateReserved": "2025-06-05T15:26:11.512Z",
"dateUpdated": "2025-10-07T03:29:00.117Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}