All the vulnerabilites related to Schneider Electric - EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module
cve-2023-5986
Vulnerability from cvelistv5
Published
2023-11-15 03:47
Modified
2024-08-02 08:14
Summary
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:25.141Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power Monitoring Expert (PME)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2020 CU2 and prior"
            },
            {
              "status": "affected",
              "version": "Version 2021 CU1 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
            },
            {
              "status": "affected",
              "version": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"
            }
          ],
          "value": "\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-15T03:47:17.684Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-5986",
    "datePublished": "2023-11-15T03:47:17.684Z",
    "dateReserved": "2023-11-07T10:57:54.715Z",
    "dateUpdated": "2024-08-02T08:14:25.141Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-5987
Vulnerability from cvelistv5
Published
2023-11-15 03:48
Modified
2024-08-02 08:14
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:25.122Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power Monitoring Expert (PME)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2020 CU2 and prior"
            },
            {
              "status": "affected",
              "version": "Version 2021 CU1 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
            },
            {
              "status": "affected",
              "version": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
            }
          ],
          "value": "\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-15T03:48:50.993Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-5987",
    "datePublished": "2023-11-15T03:48:50.993Z",
    "dateReserved": "2023-11-07T10:58:51.030Z",
    "dateUpdated": "2024-08-02T08:14:25.122Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}