Search criteria
4 vulnerabilities found for EdgeMAX EdgeSwitch by Ubiquiti Inc
CVE-2025-48978 (GCVE-0-2025-48978)
Vulnerability from cvelistv5 – Published: 2025-08-21 00:01 – Updated: 2025-08-21 14:16
VLAI?
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
Affected Products:
EdgeMAX EdgeSwitch (Version 1.11.0 and earlier)
Mitigation:
Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.
Severity ?
7.5 (High)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Inc | EdgeMAX EdgeSwitch |
Affected:
1.11.1 , < 1.11.1
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-48978",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-21T14:15:24.082992Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-21T14:16:25.992Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EdgeMAX EdgeSwitch",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.1",
"status": "affected",
"version": "1.11.1",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\r\n\r\nAffected Products:\r\n\r\nEdgeMAX EdgeSwitch (Version 1.11.0 and earlier) \r\n\r\n \r\n\r\nMitigation:\r\n\r\nUpdate the EdgeMAX EdgeSwitch to Version 1.11.1 or later."
}
],
"providerMetadata": {
"dateUpdated": "2025-08-21T00:01:24.208Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-054-054/3033f0b7-aca6-4d70-8c51-d3e706bd0ca7"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-48978",
"datePublished": "2025-08-21T00:01:24.208Z",
"dateReserved": "2025-05-29T15:00:04.772Z",
"dateUpdated": "2025-08-21T14:16:25.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27211 (GCVE-0-2025-27211)
Vulnerability from cvelistv5 – Published: 2025-08-04 22:12 – Updated: 2025-08-05 13:26
VLAI?
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
Severity ?
7.5 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Inc | EdgeMAX EdgeSwitch |
Unaffected:
1.11.0 , < 1.11.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-27211",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-05T13:22:10.644805Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-05T13:26:05.845Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "EdgeMAX EdgeSwitch",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.0",
"status": "unaffected",
"version": "1.11.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network."
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T22:12:18.821Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-27211",
"datePublished": "2025-08-04T22:12:18.821Z",
"dateReserved": "2025-02-20T01:00:01.799Z",
"dateUpdated": "2025-08-05T13:26:05.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-48978 (GCVE-0-2025-48978)
Vulnerability from nvd – Published: 2025-08-21 00:01 – Updated: 2025-08-21 14:16
VLAI?
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
Affected Products:
EdgeMAX EdgeSwitch (Version 1.11.0 and earlier)
Mitigation:
Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.
Severity ?
7.5 (High)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Inc | EdgeMAX EdgeSwitch |
Affected:
1.11.1 , < 1.11.1
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-48978",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-21T14:15:24.082992Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-21T14:16:25.992Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EdgeMAX EdgeSwitch",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.1",
"status": "affected",
"version": "1.11.1",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\r\n\r\nAffected Products:\r\n\r\nEdgeMAX EdgeSwitch (Version 1.11.0 and earlier) \r\n\r\n \r\n\r\nMitigation:\r\n\r\nUpdate the EdgeMAX EdgeSwitch to Version 1.11.1 or later."
}
],
"providerMetadata": {
"dateUpdated": "2025-08-21T00:01:24.208Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-054-054/3033f0b7-aca6-4d70-8c51-d3e706bd0ca7"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-48978",
"datePublished": "2025-08-21T00:01:24.208Z",
"dateReserved": "2025-05-29T15:00:04.772Z",
"dateUpdated": "2025-08-21T14:16:25.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27211 (GCVE-0-2025-27211)
Vulnerability from nvd – Published: 2025-08-04 22:12 – Updated: 2025-08-05 13:26
VLAI?
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
Severity ?
7.5 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Inc | EdgeMAX EdgeSwitch |
Unaffected:
1.11.0 , < 1.11.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-27211",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-05T13:22:10.644805Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-05T13:26:05.845Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "EdgeMAX EdgeSwitch",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.0",
"status": "unaffected",
"version": "1.11.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network."
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T22:12:18.821Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-27211",
"datePublished": "2025-08-04T22:12:18.821Z",
"dateReserved": "2025-02-20T01:00:01.799Z",
"dateUpdated": "2025-08-05T13:26:05.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}