CVE-2025-27211 (GCVE-0-2025-27211)

Vulnerability from cvelistv5 – Published: 2025-08-04 22:12 – Updated: 2025-08-05 13:26
VLAI?
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
CWE
  • CWE-20 - Improper Input Validation
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Ubiquiti Inc EdgeMAX EdgeSwitch Unaffected: 1.11.0 , < 1.11.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-27211",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-05T13:22:10.644805Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          },
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-05T13:26:05.845Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "EdgeMAX EdgeSwitch",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.11.0",
              "status": "unaffected",
              "version": "1.11.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-04T22:12:18.821Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2025-27211",
    "datePublished": "2025-08-04T22:12:18.821Z",
    "dateReserved": "2025-02-20T01:00:01.799Z",
    "dateUpdated": "2025-08-05T13:26:05.845Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-27211\",\"sourceIdentifier\":\"support@hackerone.com\",\"published\":\"2025-08-04T23:15:27.403\",\"lastModified\":\"2025-08-05T14:34:17.327\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\"},{\"lang\":\"es\",\"value\":\"Una validaci\u00f3n de entrada incorrecta en EdgeMAX EdgeSwitch (versi\u00f3n 1.10.4 y anteriores) podr\u00eda permitir una inyecci\u00f3n de comandos por parte de un actor malicioso con acceso a la red adyacente de EdgeSwitch.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"},{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961\",\"source\":\"support@hackerone.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-27211\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-05T13:22:10.644805Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-05T13:24:18.757Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Ubiquiti Inc\", \"product\": \"EdgeMAX EdgeSwitch\", \"versions\": [{\"status\": \"unaffected\", \"version\": \"1.11.0\", \"lessThan\": \"1.11.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\"}], \"providerMetadata\": {\"orgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"shortName\": \"hackerone\", \"dateUpdated\": \"2025-08-04T22:12:18.821Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-27211\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-05T13:26:05.845Z\", \"dateReserved\": \"2025-02-20T01:00:01.799Z\", \"assignerOrgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"datePublished\": \"2025-08-04T22:12:18.821Z\", \"assignerShortName\": \"hackerone\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…