All the vulnerabilites related to Brocade - Fabric OS
cve-2024-7517
Vulnerability from cvelistv5
Published
2024-11-21 05:53
Modified
2024-11-21 17:52
Summary
Privileged escalation via crafted use of portcfg command
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:brocade:fabric_os:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fabric_os",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "9.2.0c",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "9.2.1a",
                "status": "affected",
                "version": "9.2.1",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7517",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T14:02:36.321972Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T17:52:58.535Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS versions before 9.2.0c, and 9.2.1 through 9.2.1a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\u003c/p\u003e\u003cp\u003eThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack.\u003c/p\u003e"
            }
          ],
          "value": "A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\n\nThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T05:55:00.417Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25071"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Privileged escalation via crafted use of portcfg command",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-7517",
    "datePublished": "2024-11-21T05:53:34.442Z",
    "dateReserved": "2024-08-05T22:49:54.345Z",
    "dateUpdated": "2024-11-21T17:52:58.535Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-10403
Vulnerability from cvelistv5
Published
2024-11-21 05:44
Modified
2024-11-21 17:53
Summary
SFTP/FTP password could be captured in plain text in Supportsave generated from SANnav
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10403",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:53:45.541331Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T17:53:51.483Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS versions before  8.2.3e2, versions 9.0.0 through 9.2.0c, and 9.2.1 through 9.2.1a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade Fabric OS versions before \n8.2.3e2, versions 9.0.0 through 9.2.0c, and 9.2.1 through 9.2.1a can \ncapture the SFTP/FTP server password used for a firmware download \noperation initiated by SANnav or through WebEM in a weblinker core dump \nthat is later captured via supportsave."
            }
          ],
          "value": "Brocade Fabric OS versions before \n8.2.3e2, versions 9.0.0 through 9.2.0c, and 9.2.1 through 9.2.1a can \ncapture the SFTP/FTP server password used for a firmware download \noperation initiated by SANnav or through WebEM in a weblinker core dump \nthat is later captured via supportsave."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-528",
              "description": "CWE-528: Exposure of Core Dump File to an Unauthorized Control Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T05:46:07.170Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25145"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "SFTP/FTP password could be captured in plain text in Supportsave generated from SANnav",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-10403",
    "datePublished": "2024-11-21T05:44:30.658Z",
    "dateReserved": "2024-10-25T23:28:02.085Z",
    "dateUpdated": "2024-11-21T17:53:51.483Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31429
Vulnerability from cvelistv5
Published
2023-08-01 20:20
Modified
2024-10-15 14:12
Summary
Multiple commands print sensitive information in the terminal
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:30.864Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22408"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31429",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T14:08:06.655868Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T14:12:35.099Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade Fabric OS v9.1.1c, v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBrocade Fabric OS before Brocade Fabric OS 9.1.1c, 9.2.0 contains a vulnerability when using various commands such as \u201cchassisdistribute\u201d, \u201creboot\u201d, \u201crasman\u201d, errmoduleshow, errfilterset, hassiscfgperrthreshold, supportshowcfgdisable and supportshowcfgenable commands that can cause the content of shell interpreted variables to be printed in the terminal.\u003c/span\u003e"
            }
          ],
          "value": "Brocade Fabric OS before Brocade Fabric OS 9.1.1c, 9.2.0 contains a vulnerability when using various commands such as \u201cchassisdistribute\u201d, \u201creboot\u201d, \u201crasman\u201d, errmoduleshow, errfilterset, hassiscfgperrthreshold, supportshowcfgdisable and supportshowcfgenable commands that can cause the content of shell interpreted variables to be printed in the terminal."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-155",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-155: Screen Temporary Files for Sensitive Information"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-209",
              "description": "CWE-209 Generation of Error Message Containing Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-18T21:53:45.190Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22408"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Multiple commands print sensitive information in the terminal",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31429",
    "datePublished": "2023-08-01T20:20:52.128Z",
    "dateReserved": "2023-04-28T00:14:58.125Z",
    "dateUpdated": "2024-10-15T14:12:35.099Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31928
Vulnerability from cvelistv5
Published
2023-08-01 23:53
Modified
2024-08-02 15:03
Summary
XSS vulnerability in Brocade Webtools
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:03:28.616Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22390"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": " before Brocade Fabric OS v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA reflected cross-site scripting (XSS) vulnerability exists in Brocade Webtools PortSetting.html  of Brocade Fabric OS version before Brocade Fabric OS v9.2.0 that could allow a remote unauthenticated attacker to execute arbitrary JavaScript code in a target user\u2019s session with the Brocade Webtools application.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA reflected cross-site scripting (XSS) vulnerability exists in Brocade Webtools PortSetting.html  of Brocade Fabric OS version before Brocade Fabric OS v9.2.0 that could allow a remote unauthenticated attacker to execute arbitrary JavaScript code in a target user\u2019s session with the Brocade Webtools application.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-243",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-243 XSS Targeting HTML Attributes"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:54:09.968Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22390"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "XSS vulnerability in Brocade Webtools",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31928",
    "datePublished": "2023-08-01T23:53:58.100Z",
    "dateReserved": "2023-04-29T01:29:30.560Z",
    "dateUpdated": "2024-08-02T15:03:28.616Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31926
Vulnerability from cvelistv5
Published
2023-08-02 00:22
Modified
2024-08-02 15:03
Summary
Arbitrary File Overwrite using less command
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:03:28.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22388"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade Fabric OS v9.1.1c and v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "System files could be overwritten using the less command in Brocade Fabric OS before Brocade Fabric OS v9.1.1c and v9.2.0.\u003cbr\u003e\n\n"
            }
          ],
          "value": "System files could be overwritten using the less command in Brocade Fabric OS before Brocade Fabric OS v9.1.1c and v9.2.0.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-165",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-165 File Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-281",
              "description": "CWE-281 Improper Preservation of Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-665",
              "description": "CWE-665 Improper Initialization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-02T00:23:05.117Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22388"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Arbitrary File Overwrite using less command",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31926",
    "datePublished": "2023-08-02T00:22:14.166Z",
    "dateReserved": "2023-04-29T01:29:30.560Z",
    "dateUpdated": "2024-08-02T15:03:28.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31428
Vulnerability from cvelistv5
Published
2023-08-01 23:41
Modified
2024-10-11 14:08
Summary
CLI allows upload or transfer files of dangerous types
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:30.907Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22380"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31428",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-11T13:03:12.520187Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-11T14:08:28.685Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade Fabric OS v9.1.1c, v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade Fabric OS before Brocade Fabric OS v9.1.1c, v9.2.0 contains a vulnerability in the command line that could allow a local user to dump files under user\u0027s home directory using grep.\u003cbr\u003e\n\n"
            }
          ],
          "value": "Brocade Fabric OS before Brocade Fabric OS v9.1.1c, v9.2.0 contains a vulnerability in the command line that could allow a local user to dump files under user\u0027s home directory using grep.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:41:50.210Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22380"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CLI allows upload or transfer files of dangerous types",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31428",
    "datePublished": "2023-08-01T23:41:41.990Z",
    "dateReserved": "2023-04-28T00:14:58.125Z",
    "dateUpdated": "2024-10-11T14:08:28.685Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-5460
Vulnerability from cvelistv5
Published
2024-06-25 23:58
Modified
2024-08-01 21:11
Summary
Brocade Fabric OS versions prior to v9.0 have default community strings
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5460",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T19:06:00.801188Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T19:06:08.423Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:11:12.746Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/24409"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "prior to v9.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nA vulnerability in the default configuration of the Simple Network \nManagement Protocol (SNMP) feature of Brocade Fabric OS versions before \nv9.0.0 could allow an authenticated, remote attacker to read data from \nan affected device via SNMP. The vulnerability is due to hard-coded, \ndefault community string in the configuration file for the SNMP daemon. \nAn attacker could exploit this vulnerability by using the static \ncommunity string in SNMP version 1 queries to an affected device.\n\n"
            }
          ],
          "value": "A vulnerability in the default configuration of the Simple Network \nManagement Protocol (SNMP) feature of Brocade Fabric OS versions before \nv9.0.0 could allow an authenticated, remote attacker to read data from \nan affected device via SNMP. The vulnerability is due to hard-coded, \ndefault community string in the configuration file for the SNMP daemon. \nAn attacker could exploit this vulnerability by using the static \ncommunity string in SNMP version 1 queries to an affected device."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-70",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-70 Try Common or Default Usernames and Passwords"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T23:58:10.683Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/24409"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Brocade Fabric OS versions prior to v9.0 have default community strings",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-5460",
    "datePublished": "2024-06-25T23:58:10.683Z",
    "dateReserved": "2024-05-29T02:20:36.775Z",
    "dateUpdated": "2024-08-01T21:11:12.746Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31425
Vulnerability from cvelistv5
Published
2023-08-01 20:34
Modified
2024-10-18 20:20
Summary
Privilege escalation via the fosexec command
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:30.965Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22407"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31425",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-18T20:19:05.869901Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-18T20:20:48.709Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS ",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "after Brocade Fabric OS v9.1.0 and, before Brocade Fabric OS v9.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability in the fosexec command of Brocade Fabric OS after Brocade Fabric OS v9.1.0 and, before Brocade Fabric OS v9.1.1 could allow a local authenticated user to perform privilege escalation to root by breaking the rbash shell. Starting with Fabric OS v9.1.0, \u201croot\u201d account access is disabled.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA vulnerability in the fosexec command of Brocade Fabric OS after Brocade Fabric OS v9.1.0 and, before Brocade Fabric OS v9.1.1 could allow a local authenticated user to perform privilege escalation to root by breaking the rbash shell. Starting with Fabric OS v9.1.0, \u201croot\u201d account access is disabled.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Privilege escalation ",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:02:55.548Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22407"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Privilege escalation via the fosexec command",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31425",
    "datePublished": "2023-08-01T20:34:47.165Z",
    "dateReserved": "2023-04-28T00:14:58.124Z",
    "dateUpdated": "2024-10-18T20:20:48.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31432
Vulnerability from cvelistv5
Published
2023-08-01 23:58
Modified
2024-10-17 18:32
Summary
Privilege issues in multiple commands
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:30.665Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22385"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31432",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T18:31:52.659185Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T18:32:12.504Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade Fabric OS v9.1.1c and v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Through manipulation of passwords or other variables, using commands such as portcfgupload, configupload, license, myid, a non-privileged user could obtain root privileges in Brocade Fabric OS versions before Brocade Fabric OS v9.1.1c and v9.2.0.\u003cbr\u003e\n\n"
            }
          ],
          "value": "Through manipulation of passwords or other variables, using commands such as portcfgupload, configupload, license, myid, a non-privileged user could obtain root privileges in Brocade Fabric OS versions before Brocade Fabric OS v9.1.1c and v9.2.0.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:58:59.015Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22385"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Privilege issues in multiple commands",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31432",
    "datePublished": "2023-08-01T23:58:59.015Z",
    "dateReserved": "2023-04-28T00:14:58.125Z",
    "dateUpdated": "2024-10-17T18:32:12.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-3454
Vulnerability from cvelistv5
Published
2024-04-04 17:03
Modified
2024-08-02 06:55
Summary
Remote code execution (RCE) vulnerability in Brocade Fabric OS after v9.0 and before v9.2.0 could allow an attacker to execute arbitrary code and use this to gain root access to the Brocade switch.
Impacted products
Brocade Fabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:broadcom:brocade_fabric_operating_system:9.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "brocade_fabric_operating_system",
            "vendor": "broadcom",
            "versions": [
              {
                "lessThan": "9.2.0",
                "status": "affected",
                "version": "9.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-3454",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-08T13:23:36.479859Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T15:00:34.252Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:55:03.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23215"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240628-0004/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade ",
          "versions": [
            {
              "status": "affected",
              "version": "after v9.0 and before v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Remote code execution (RCE) vulnerability in Brocade Fabric OS after v9.0 and before v9.2.0 could allow an attacker to execute arbitrary code and use this to gain root access to the Brocade switch.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Remote code execution (RCE) vulnerability in Brocade Fabric OS after v9.0 and before v9.2.0 could allow an attacker to execute arbitrary code and use this to gain root access to the Brocade switch.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-04T17:03:54.171Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23215"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240628-0004/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-3454",
    "datePublished": "2024-04-04T17:03:54.171Z",
    "dateReserved": "2023-06-28T21:20:18.502Z",
    "dateUpdated": "2024-08-02T06:55:03.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-5973
Vulnerability from cvelistv5
Published
2024-04-05 02:33
Modified
2024-08-02 08:14
Summary
Truncated port name
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5973",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-05T15:54:19.812462Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:28:45.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:14:25.193Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23214"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240628-0005/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Versions v9.x and before v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade\n Web Interface in Brocade Fabric OS v9.x and before v9.2.0 does not \nproperly represent the portName to the user if the portName contains \nreserved characters. This could allow an authenticated user to alter the\n UI of the Brocade Switch and change ports display.\n\n"
            }
          ],
          "value": "Brocade\n Web Interface in Brocade Fabric OS v9.x and before v9.2.0 does not \nproperly represent the portName to the user if the portName contains \nreserved characters. This could allow an authenticated user to alter the\n UI of the Brocade Switch and change ports display.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 HTTP DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-346",
              "description": "CWE-346 Origin Validation Error",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-05T02:33:46.116Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23214"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240628-0005/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Truncated port name",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-5973",
    "datePublished": "2024-04-05T02:33:46.116Z",
    "dateReserved": "2023-11-06T20:20:06.784Z",
    "dateUpdated": "2024-08-02T08:14:25.193Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29953
Vulnerability from cvelistv5
Published
2024-06-25 23:16
Modified
2024-08-22 18:03
Summary
Encoded session passwords on session storage for Virtual Fabric platforms
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29953",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T23:39:35.142531Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T23:39:40.986Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-22T18:03:11.060Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/23227"
          },
          {
            "url": "https://security.netapp.com/advisory/ntap-20240822-0009/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v9.2.1, v9.2.0b, and v9.1.1d"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability in the web interface in Brocade Fabric OS before v9.2.1, v9.2.0b, and v9.1.1d prints encoded session passwords on session storage for Virtual Fabric platforms. \u003c/span\u003e\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThis could allow an authenticated user to view other users\u0027 session encoded passwords.\u003c/span\u003e\n\n"
            }
          ],
          "value": "A vulnerability in the web interface in Brocade Fabric OS before v9.2.1, v9.2.0b, and v9.1.1d prints encoded session passwords on session storage for Virtual Fabric platforms. \nThis could allow an authenticated user to view other users\u0027 session encoded passwords."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-922",
              "description": "CWE-922 Insecure Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T23:16:48.169Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/23227"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eThe security update is provided in Brocade Fabric OS v9.2.1, v9.2.0b, v9.1.1d\u003c/p\u003e"
            }
          ],
          "value": "The security update is provided in Brocade Fabric OS v9.2.1, v9.2.0b, v9.1.1d"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Encoded session passwords on session storage for Virtual Fabric platforms",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29953",
    "datePublished": "2024-06-25T23:16:48.169Z",
    "dateReserved": "2024-03-22T05:00:09.537Z",
    "dateUpdated": "2024-08-22T18:03:11.060Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31427
Vulnerability from cvelistv5
Published
2023-08-01 22:46
Modified
2024-08-02 14:53
Summary
Knowledge of full path name
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:31.074Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22379"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "after 9.1.0 and before Brocade Fabric OS v9.2.0 and v9.1.1c"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eBrocade Fabric OS versions before Brocade Fabric OS v9.1.1c, and v9.2.0 Could allow an authenticated, local user with knowledge of full path names inside Brocade Fabric OS to execute any command regardless of assigned privilege. Starting with Fabric OS v9.1.0, \u201croot\u201d account access is disabled.\u003c/span\u003e\n\n\u003cbr\u003e\u003c/p\u003e\n\n"
            }
          ],
          "value": "\n\n\nBrocade Fabric OS versions before Brocade Fabric OS v9.1.1c, and v9.2.0 Could allow an authenticated, local user with knowledge of full path names inside Brocade Fabric OS to execute any command regardless of assigned privilege. Starting with Fabric OS v9.1.0, \u201croot\u201d account access is disabled.\n\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-126",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-126 Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:03:22.805Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22379"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Knowledge of full path name",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31427",
    "datePublished": "2023-08-01T22:46:17.756Z",
    "dateReserved": "2023-04-28T00:14:58.125Z",
    "dateUpdated": "2024-08-02T14:53:31.074Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31431
Vulnerability from cvelistv5
Published
2023-08-01 23:23
Modified
2024-08-02 14:53
Summary
A buffer overflow vulnerability in “diagstatus” command
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:31.082Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22384"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade Fabric OS v9.1.1c, v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A buffer overflow vulnerability in \u201cdiagstatus\u201d command in Brocade Fabric OS before Brocade Fabric v9.2.0 and v9.1.1c could allow an authenticated user to crash the Brocade Fabric OS switch leading to a denial of service.\u003cbr\u003e\n\n"
            }
          ],
          "value": "A buffer overflow vulnerability in \u201cdiagstatus\u201d command in Brocade Fabric OS before Brocade Fabric v9.2.0 and v9.1.1c could allow an authenticated user to crash the Brocade Fabric OS switch leading to a denial of service.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-25",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-25 Forced Deadlock"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:23:18.522Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22384"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A buffer overflow vulnerability in \u201cdiagstatus\u201d command",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31431",
    "datePublished": "2023-08-01T23:23:18.522Z",
    "dateReserved": "2023-04-28T00:14:58.125Z",
    "dateUpdated": "2024-08-02T14:53:31.082Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-3489
Vulnerability from cvelistv5
Published
2023-08-30 23:56
Modified
2024-10-01 18:11
Summary
firmwaredownload command could log servers passwords in clear text
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:55:03.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22510"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20231124-0003/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-3489",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T18:10:53.141684Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T18:11:15.213Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Director",
            "Switches",
            "Extension Switches"
          ],
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The \nfirmwaredownload command on Brocade Fabric OS v9.2.0 could log the \nFTP/SFTP/SCP server password in clear text in the SupportSave file when \nperforming a downgrade from Fabric OS v9.2.0 to any earlier version of \nFabric OS.\n\n"
            }
          ],
          "value": "The \nfirmwaredownload command on Brocade Fabric OS v9.2.0 could log the \nFTP/SFTP/SCP server password in clear text in the SupportSave file when \nperforming a downgrade from Fabric OS v9.2.0 to any earlier version of \nFabric OS.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T23:56:18.010Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22510"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20231124-0003/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "firmwaredownload command could log servers passwords in clear text",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The workaround is to use the web interface, REST API or to run the \u201cfirmwaredownload \u201c command in interactive mode.\u003cbr\u003e"
            }
          ],
          "value": "The workaround is to use the web interface, REST API or to run the \u201cfirmwaredownload \u201c command in interactive mode.\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-3489",
    "datePublished": "2023-08-30T23:56:07.070Z",
    "dateReserved": "2023-06-30T20:35:33.224Z",
    "dateUpdated": "2024-10-01T18:11:15.213Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-4162
Vulnerability from cvelistv5
Published
2023-08-31 00:14
Modified
2024-09-30 15:47
Summary
Segmentation fault in Brocade Fabric OS after Brocade Fabric OS v9.0
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:17:12.031Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22513"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20231124-0010/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4162",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-30T15:44:50.392651Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-30T15:47:48.730Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Directors",
            "Extensions Switches",
            "Switches"
          ],
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS after Brocade Fabric OS v9.0 and before Brocade Fabric OS v9.2.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A\n segmentation fault can occur in Brocade Fabric OS after Brocade Fabric \nOS v9.0 and before Brocade Fabric OS v9.2.0a through the passwdcfg \ncommand. This\n could allow an authenticated privileged user local user to crash a \nBrocade Fabric OS swith using the cli \u201cpasswdcfg --set -expire \n-minDiff\u201c."
            }
          ],
          "value": "A\n segmentation fault can occur in Brocade Fabric OS after Brocade Fabric \nOS v9.0 and before Brocade Fabric OS v9.2.0a through the passwdcfg \ncommand. This\n could allow an authenticated privileged user local user to crash a \nBrocade Fabric OS swith using the cli \u201cpasswdcfg --set -expire \n-minDiff\u201c."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-540",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-540 Overread Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-252",
              "description": "CWE-252 Unchecked Return Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-18T22:00:38.366Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22513"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20231124-0010/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Segmentation fault in Brocade Fabric OS after Brocade Fabric OS v9.0",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-4162",
    "datePublished": "2023-08-31T00:14:15.612Z",
    "dateReserved": "2023-08-04T18:20:32.891Z",
    "dateUpdated": "2024-09-30T15:47:48.730Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-7516
Vulnerability from cvelistv5
Published
2024-11-12 18:41
Modified
2024-11-21 16:17
Summary
Brocade Fabric OS before 9.2.2 does not enforce strict host key checking
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7516",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T14:14:29.365761Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T16:17:44.152Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before 9.2.2"
            }
          ]
        }
      ],
      "datePublic": "2024-11-12T18:38:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eA vulnerability in Brocade Fabric OS versions before 9.2.2 could \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow man-in-the-middle attackers to conduct remote Service Session Hijacking that may arise from the attacker\u0027s ability to forge an SSH key while the Brocade Fabric OS Switch is performing various remote operations initiated by a switch admin.\u003c/span\u003e\u003cspan style=\"background-color: transparent;\"\u003e\u0026nbsp;\u003c/span\u003e\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability in Brocade Fabric OS versions before 9.2.2 could allow man-in-the-middle attackers to conduct remote Service Session Hijacking that may arise from the attacker\u0027s ability to forge an SSH key while the Brocade Fabric OS Switch is performing various remote operations initiated by a switch admin."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-97",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-97 Cryptanalysis"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:L/VI:L/VA:H/SC:H/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-322",
              "description": "CWE-322: Key Exchange without Entity Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T18:41:54.940Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25177"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade Fabric OS before 9.2.2 does not enforce strict host key checking",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-7516",
    "datePublished": "2024-11-12T18:41:54.940Z",
    "dateReserved": "2024-08-05T22:49:44.217Z",
    "dateUpdated": "2024-11-21T16:17:44.152Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31927
Vulnerability from cvelistv5
Published
2023-08-02 00:06
Modified
2024-10-18 14:41
Summary
An information disclosure in the web interface of Brocade Fabric OS
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:03:28.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22389"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31927",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-18T14:41:13.883150Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-18T14:41:27.885Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": " before Brocade Fabric OS v9.2.0 and v9.1.1c"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An information disclosure in the web interface of Brocade Fabric OS versions before Brocade Fabric OS v9.2.0 and v9.1.1c, could allow a remote unauthenticated attacker to get technical details about the web interface.\u003cbr\u003e\n\n"
            }
          ],
          "value": "An information disclosure in the web interface of Brocade Fabric OS versions before Brocade Fabric OS v9.2.0 and v9.1.1c, could allow a remote unauthenticated attacker to get technical details about the web interface.\n\n\n"
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information disclosure"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-02T00:09:26.337Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22389"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "An information disclosure in the web interface of Brocade Fabric OS",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31927",
    "datePublished": "2023-08-02T00:06:48.374Z",
    "dateReserved": "2023-04-29T01:29:30.560Z",
    "dateUpdated": "2024-10-18T14:41:27.885Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29954
Vulnerability from cvelistv5
Published
2024-06-25 23:42
Modified
2024-08-22 18:03
Summary
password management API prints sensitive information in log files
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29954",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T15:04:17.122827Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T15:04:23.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-22T18:03:11.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/23226"
          },
          {
            "url": "https://security.netapp.com/advisory/ntap-20240822-0010/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v9.2.1, v9.2.0b, v9.1.1d, and v8.2.3e"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eA vulnerability in a password management API in Brocade Fabric OS versions before v9.2.1, v9.2.0b, v9.1.1d, and v8.2.3e prints sensitive information in log files. This could allow an authenticated user to view the server passwords for protocols such as scp and sftp.\u003c/p\u003e\u003cp\u003eDetail.\u003cbr\u003eWhen the firmwaredownload command is incorrectly entered or points to an erroneous file, the firmware download log captures the failed command, including any password entered in the command line. \u003c/p\u003e\n\n"
            }
          ],
          "value": "A vulnerability in a password management API in Brocade Fabric OS versions before v9.2.1, v9.2.0b, v9.1.1d, and v8.2.3e prints sensitive information in log files. This could allow an authenticated user to view the server passwords for protocols such as scp and sftp.\n\nDetail.\nWhen the firmwaredownload command is incorrectly entered or points to an erroneous file, the firmware download log captures the failed command, including any password entered in the command line."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T23:42:50.227Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/23226"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSecurity update provided in Brocade Fabric OS v9.2.1, v9.2.0b, v9.1.1d, v8.2.3e\u003c/p\u003e"
            }
          ],
          "value": "Security update provided in Brocade Fabric OS v9.2.1, v9.2.0b, v9.1.1d, v8.2.3e"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "password management API prints sensitive information in log files",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29954",
    "datePublished": "2024-06-25T23:42:50.227Z",
    "dateReserved": "2024-03-22T05:00:09.538Z",
    "dateUpdated": "2024-08-22T18:03:11.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-201608-0289
Vulnerability from variot

HPE FOS before 7.4.1d and 8.x before 8.0.1 on StoreFabric B switches allows remote attackers to obtain sensitive information via unspecified vectors. Supplementary information : CWE Vulnerability type by CWE-254: Security Features ( Security function ) Has been identified. http://cwe.mitre.org/data/definitions/254.htmlImportant information may be obtained by a third party. HPStoreFabricB-seriesSwitches is a series of switches from Hewlett Packard (HP). An unexplained information disclosure vulnerability exists in the HPStoreFabricB-seriesSwitches7.x release. A remote attacker could exploit this vulnerability to gain access to sensitive information. -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1

Note: the current version of the following document is available here: https://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_n a-c05236212

SUPPORT COMMUNICATION - SECURITY BULLETIN

Document ID: c05236212 Version: 1

HPSBST03629 rev.1 - HP StoreFabric B-series Switches, Remote Disclosure of Privileged Information

NOTICE: The information in this Security Bulletin should be acted upon as soon as possible.

References:

CVE-2016-4376 PSRT110173

SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. StoreFabric B-series Switches FOS 7.x

BACKGROUND

CVSS Base Metrics ================= Reference, CVSS V3 Score/Vector, CVSS V2 Score/Vector

CVE-2016-4376
  5.7 CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N
  7.8 (AV:N/AC:L/Au:N/C:C/I:N/A:N)

Information on CVSS is documented in
HPE Customer Notice HPSN-2008-002 here:

  https://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay/?docI

d=emr_na-c01345499

Hewlett Packard Enterprise thanks Daniel Compton of Info-Assure Ltd. for reporting this vulnerability to security-alert@hpe.com.

RESOLUTION

HPE has made the following firmware patch available to resolve the vulnerability in Store Fabric B-series switches.

The fix is available in HPE B-series FOS v7.4.1d and v8.0.1

To download the patch go to http://www.hpe.com/support

Select "HPE Servers, Storage and Networking" under Product Support. Search for your HPE StoreFabric B-series switch model. Select "Get drivers, software & firmware" Click "Firmware" under OS Independent Downloads. To read the Brocade Release Notes , click the "Manuals" link under the Knowledge Base tab. To read the HPE Release Notes , click the "Release Notes" tab in the firmware download page. Also, in the "Manuals" section, see the Fabric OS Administrators Guide for a description of the process to verify the firmware download is complete.

HISTORY Version:1 (rev.1) - 12 August 2016 Initial release

Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy.

Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com.

Report: To report a potential security vulnerability for any HPE supported product: Web form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com

Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice

Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive

Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB.

3C = 3COM 3P = 3rd Party Software GN = HPE General Software HF = HPE Hardware and Firmware MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PV = ProCurve ST = Storage Software UX = HP-UX

Copyright 2016 Hewlett Packard Enterprise

Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise and the names of Hewlett Packard Enterprise products referenced herein are trademarks of Hewlett Packard Enterprise in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

-----BEGIN PGP SIGNATURE----- Version: GnuPG v1

iQEcBAEBAgAGBQJXrioLAAoJEGIGBBYqRO9/nBUIAKU+sWfFiB36FGJeHwySMxMO WOfrRMclhGtqQrD4KrZVLKXY03DusX+cCuKEQD6DrGPq5MiPPOG/Wf/Tbx15L5k1 IsxKaCR69Wexu4/hNtiqc7VVqBJjEhLl95ULBiFFXFCRmkKAp8K1cBPym7/27aJd b/nffNX3zL6K9vihBAdbOLr/XtxccjUMKKCSIx+juGCPONkh9XTfJZIxipM4BNWF aeycrY4RXOSMNMu27XCi5FiHbuTysvbyYDM7bCghwiXatW8Hi6DYJE6ffTuIYsx9 qquu5SPlTZPgxwOWD5Gx/pgB1Eep8fM9PDzQHBcFtcLJH8oIi5pdgsBRxzMQ2AA= =x+Te -----END PGP SIGNATURE-----

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201608-0289",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fabric operating system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "7.4.1"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.0.0"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "brocade",
        "version": "8.0.1"
      },
      {
        "model": "fabric os",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "brocade",
        "version": "8.x"
      },
      {
        "model": "storefabric b series storage switch",
        "scope": null,
        "trust": 0.8,
        "vendor": "hewlett packard",
        "version": null
      },
      {
        "model": "storefabric b-series switches",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "hp",
        "version": "7.x"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "7.4.1"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.0.0"
      },
      {
        "model": "storefabric b-series switches",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "hp",
        "version": "7.0"
      },
      {
        "model": "storefabric b-series switches",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "hp",
        "version": "8.0.1"
      },
      {
        "model": "storefabric b-series switches 7.4.1d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "hp",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "BID",
        "id": "92480"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "7.4.1",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:hp:storefabric_b_series_switch:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "92480"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2016-4376",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.8,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2016-4376",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2016-06462",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2016-4376",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2016-4376",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2016-06462",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201608-321",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "HPE FOS before 7.4.1d and 8.x before 8.0.1 on StoreFabric B switches allows remote attackers to obtain sensitive information via unspecified vectors. Supplementary information : CWE Vulnerability type by CWE-254: Security Features ( Security function ) Has been identified. http://cwe.mitre.org/data/definitions/254.htmlImportant information may be obtained by a third party. HPStoreFabricB-seriesSwitches is a series of switches from Hewlett Packard (HP). An unexplained information disclosure vulnerability exists in the HPStoreFabricB-seriesSwitches7.x release. A remote attacker could exploit this vulnerability to gain access to sensitive information. -----BEGIN PGP SIGNED MESSAGE-----\nHash: SHA1\n\nNote: the current version of the following document is available here:\nhttps://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_n\na-c05236212\n\nSUPPORT COMMUNICATION - SECURITY BULLETIN\n\nDocument ID: c05236212\nVersion: 1\n\nHPSBST03629 rev.1 - HP StoreFabric B-series Switches, Remote Disclosure of\nPrivileged Information\n\nNOTICE: The information in this Security Bulletin should be acted upon as\nsoon as possible. \n\nReferences:\n\nCVE-2016-4376\nPSRT110173\n\nSUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. \nStoreFabric B-series Switches FOS 7.x\n\nBACKGROUND\n\n  CVSS Base Metrics\n  =================\n  Reference, CVSS V3 Score/Vector, CVSS V2 Score/Vector\n\n    CVE-2016-4376\n      5.7 CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N\n      7.8 (AV:N/AC:L/Au:N/C:C/I:N/A:N)\n\n    Information on CVSS is documented in\n    HPE Customer Notice HPSN-2008-002 here:\n\n      https://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay/?docI\nd=emr_na-c01345499\n\nHewlett Packard Enterprise thanks Daniel Compton of Info-Assure Ltd. for\nreporting this vulnerability to security-alert@hpe.com. \n\nRESOLUTION\n\nHPE has made the following firmware patch available to resolve the\nvulnerability in Store Fabric B-series switches. \n\nThe fix is available in HPE B-series FOS v7.4.1d and v8.0.1\n\nTo download the patch go to http://www.hpe.com/support\n\nSelect \"HPE Servers, Storage and Networking\" under Product Support. \nSearch for your HPE StoreFabric B-series switch model. \nSelect \"Get drivers, software \u0026 firmware\"\nClick \"Firmware\" under OS Independent Downloads. \nTo read the Brocade Release Notes , click the \"Manuals\" link under the\nKnowledge Base tab. \nTo read the HPE Release Notes , click the \"Release Notes\" tab in the firmware\ndownload page. \nAlso, in the \"Manuals\" section, see the Fabric OS Administrators Guide for a\ndescription of the process to verify the firmware download is complete. \n\nHISTORY\nVersion:1 (rev.1) - 12 August 2016 Initial release\n\nThird Party Security Patches: Third party security patches that are to be\ninstalled on systems running Hewlett Packard Enterprise (HPE) software\nproducts should be applied in accordance with the customer\u0027s patch management\npolicy. \n\nSupport: For issues about implementing the recommendations of this Security\nBulletin, contact normal HPE Services support channel. For other issues about\nthe content of this Security Bulletin, send e-mail to security-alert@hpe.com. \n\nReport: To report a potential security vulnerability for any HPE supported\nproduct:\n  Web form: https://www.hpe.com/info/report-security-vulnerability\n  Email: security-alert@hpe.com\n\nSubscribe: To initiate a subscription to receive future HPE Security Bulletin\nalerts via Email: http://www.hpe.com/support/Subscriber_Choice\n\nSecurity Bulletin Archive: A list of recently released Security Bulletins is\navailable here: http://www.hpe.com/support/Security_Bulletin_Archive\n\nSoftware Product Category: The Software Product Category is represented in\nthe title by the two characters following HPSB. \n\n3C = 3COM\n3P = 3rd Party Software\nGN = HPE General Software\nHF = HPE Hardware and Firmware\nMU = Multi-Platform Software\nNS = NonStop Servers\nOV = OpenVMS\nPV = ProCurve\nST = Storage Software\nUX = HP-UX\n\nCopyright 2016 Hewlett Packard Enterprise\n\nHewlett Packard Enterprise shall not be liable for technical or editorial\nerrors or omissions contained herein. The information provided is provided\n\"as is\" without warranty of any kind. To the extent permitted by law, neither\nHP or its affiliates, subcontractors or suppliers will be liable for\nincidental,special or consequential damages including downtime cost; lost\nprofits; damages relating to the procurement of substitute products or\nservices; or damages for loss of data, or software restoration. The\ninformation in this document is subject to change without notice. Hewlett\nPackard Enterprise and the names of Hewlett Packard Enterprise products\nreferenced herein are trademarks of Hewlett Packard Enterprise in the United\nStates and other countries. Other product and company names mentioned herein\nmay be trademarks of their respective owners. \n\n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1\n\niQEcBAEBAgAGBQJXrioLAAoJEGIGBBYqRO9/nBUIAKU+sWfFiB36FGJeHwySMxMO\nWOfrRMclhGtqQrD4KrZVLKXY03DusX+cCuKEQD6DrGPq5MiPPOG/Wf/Tbx15L5k1\nIsxKaCR69Wexu4/hNtiqc7VVqBJjEhLl95ULBiFFXFCRmkKAp8K1cBPym7/27aJd\nb/nffNX3zL6K9vihBAdbOLr/XtxccjUMKKCSIx+juGCPONkh9XTfJZIxipM4BNWF\naeycrY4RXOSMNMu27XCi5FiHbuTysvbyYDM7bCghwiXatW8Hi6DYJE6ffTuIYsx9\nqquu5SPlTZPgxwOWD5Gx/pgB1Eep8fM9PDzQHBcFtcLJH8oIi5pdgsBRxzMQ2AA=\n=x+Te\n-----END PGP SIGNATURE-----\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "BID",
        "id": "92480"
      },
      {
        "db": "PACKETSTORM",
        "id": "138358"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2016-4376",
        "trust": 3.4
      },
      {
        "db": "BID",
        "id": "92480",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321",
        "trust": 0.6
      },
      {
        "db": "PACKETSTORM",
        "id": "138358",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "BID",
        "id": "92480"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "PACKETSTORM",
        "id": "138358"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "id": "VAR-201608-0289",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      }
    ],
    "trust": 0.85
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      }
    ]
  },
  "last_update_date": "2023-12-18T14:01:46.568000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Brocade Fabric OS (FOS) 7.x Compatibility Matrix",
        "trust": 0.8,
        "url": "https://www.brocade.com/content/dam/common/documents/content-types/product-matrix/brocade-compatibility-matrix-fos-7x-mx.pdf"
      },
      {
        "title": "HPSBST03629",
        "trust": 0.8,
        "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-c05236212"
      },
      {
        "title": "HPStoreFabricB-seriesSwitches has an undisclosed information disclosure vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/80570"
      },
      {
        "title": "HP StoreFabric B-series Switches Repair measures for information disclosure vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=63688"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-254",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-Other",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "http://www.securityfocus.com/bid/92480"
      },
      {
        "trust": 1.6,
        "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-c05236212"
      },
      {
        "trust": 0.9,
        "url": "https://h20564.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-c05236212"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-4376"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-4376"
      },
      {
        "trust": 0.3,
        "url": "http://www.hp.com"
      },
      {
        "trust": 0.1,
        "url": "https://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docdisplay?docid=emr_n"
      },
      {
        "trust": 0.1,
        "url": "http://www.hpe.com/support/security_bulletin_archive"
      },
      {
        "trust": 0.1,
        "url": "https://www.hpe.com/info/report-security-vulnerability"
      },
      {
        "trust": 0.1,
        "url": "https://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docdisplay/?doci"
      },
      {
        "trust": 0.1,
        "url": "http://www.hpe.com/support"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2016-4376"
      },
      {
        "trust": 0.1,
        "url": "http://www.hpe.com/support/subscriber_choice"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "BID",
        "id": "92480"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "PACKETSTORM",
        "id": "138358"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "db": "BID",
        "id": "92480"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "db": "PACKETSTORM",
        "id": "138358"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-08-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "date": "2016-08-12T00:00:00",
        "db": "BID",
        "id": "92480"
      },
      {
        "date": "2016-08-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "date": "2016-08-16T15:18:11",
        "db": "PACKETSTORM",
        "id": "138358"
      },
      {
        "date": "2016-08-22T10:59:05.683000",
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "date": "2016-08-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-08-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2016-06462"
      },
      {
        "date": "2016-08-12T00:00:00",
        "db": "BID",
        "id": "92480"
      },
      {
        "date": "2016-08-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      },
      {
        "date": "2021-06-22T15:20:10.497000",
        "db": "NVD",
        "id": "CVE-2016-4376"
      },
      {
        "date": "2021-06-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "HPE StoreFabric B series Runs on the storage switch  FOS Vulnerability in which important information is obtained",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-004438"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "security feature problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201608-321"
      }
    ],
    "trust": 0.6
  }
}

var-201802-0640
Vulnerability from variot

Cross-site scripting (XSS) vulnerability in the web-based management interface of Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) versions before 7.4.2b, 8.1.2 and 8.2.0 could allow remote attackers to execute arbitrary code or access sensitive browser-based information. Brocade Fabric OS (FOS) Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. BrocadeFibreChannelSANproducts are Brocade switches and BrocadeFabricOS (FOS) is an embedded system running on them. Cross-site scripting vulnerabilities exist in BrocadeFibreChannelSAN products prior to BrocadeFOS7.4.2b, pre-8.1.2, and pre-8.0. Web-based management interfaces. This may help the attacker steal cookie-based authentication credentials and launch other attacks. Broadcom Brocade Fabric OS versions prior 7.4.2b, 8.1.2 and 8.2.0 are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201802-0640",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "brocade",
        "version": "8.0.2b1"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "brocade",
        "version": "8.1.0c1"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "brocade",
        "version": "8.0.1b1"
      },
      {
        "model": "fabric operating system",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "7.4.2b"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.0.2"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.1.1"
      },
      {
        "model": "fabric os",
        "scope": null,
        "trust": 0.8,
        "vendor": "brocade",
        "version": null
      },
      {
        "model": "fibre channel san \u003c7.4.2b",
        "scope": null,
        "trust": 0.6,
        "vendor": "brocade",
        "version": null
      },
      {
        "model": "fibre channel san",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.2"
      },
      {
        "model": "fibre channel san",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.2.0"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "5.2.0"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.0.2d"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.1a"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "3.1"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "5.0.5b"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "5.2.0a"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.0.2c"
      },
      {
        "model": "brocade fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.1.1"
      },
      {
        "model": "brocade fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "7.4.2"
      },
      {
        "model": "brocade fabric os 7.4.2b",
        "scope": null,
        "trust": 0.3,
        "vendor": "broadcom",
        "version": null
      },
      {
        "model": "brocade fabric os",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.2"
      },
      {
        "model": "brocade fabric os",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.1.2"
      },
      {
        "model": "brocade fabric os 7.4.2c",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "BID",
        "id": "107051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:brocade:fabric_os:8.0.2b1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:brocade:fabric_os:8.0.1b1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:brocade:fabric_os:8.1.0c1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.4.2b",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.1.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Pawel Gocyla and Matt Byrne.",
    "sources": [
      {
        "db": "BID",
        "id": "107051"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-6225",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.3,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-6225",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2018-06323",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2017-6225",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-6225",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-06323",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201802-253",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Cross-site scripting (XSS) vulnerability in the web-based management interface of Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) versions before 7.4.2b, 8.1.2 and 8.2.0 could allow remote attackers to execute arbitrary code or access sensitive browser-based information. Brocade Fabric OS (FOS) Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. BrocadeFibreChannelSANproducts are Brocade switches and BrocadeFabricOS (FOS) is an embedded system running on them. Cross-site scripting vulnerabilities exist in BrocadeFibreChannelSAN products prior to BrocadeFOS7.4.2b, pre-8.1.2, and pre-8.0. Web-based management interfaces. This may help the attacker steal cookie-based authentication credentials and launch other attacks. \nBroadcom Brocade Fabric OS versions prior 7.4.2b, 8.1.2 and 8.2.0 are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "BID",
        "id": "107051"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-6225",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253",
        "trust": 0.6
      },
      {
        "db": "BID",
        "id": "107051",
        "trust": 0.3
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "BID",
        "id": "107051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "id": "VAR-201802-0640",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:52:48.816000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "BSA-2018-525",
        "trust": 0.8,
        "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-525"
      },
      {
        "title": "Patch for BrocadeFibreChannelSAN product BrocadeFabricOS cross-site scripting vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/123361"
      },
      {
        "title": "Brocade Fibre Channel SAN product Brocade Fabric OS Fixes for cross-site scripting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=78367"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.3,
        "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-525"
      },
      {
        "trust": 1.3,
        "url": "https://support.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026docid=emr_na-hpesbst03851en_us"
      },
      {
        "trust": 1.2,
        "url": "http://www.brocade.com/content/dam/common/documents/content-types/security-bulletin/brocade-security-advisory-2018-525.htm"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6225"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-6225"
      },
      {
        "trust": 0.3,
        "url": "http://www.broadcom.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "BID",
        "id": "107051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "db": "BID",
        "id": "107051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "date": "2018-01-17T00:00:00",
        "db": "BID",
        "id": "107051"
      },
      {
        "date": "2018-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "date": "2018-02-08T22:29:00.207000",
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "date": "2018-02-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-06323"
      },
      {
        "date": "2018-01-17T00:00:00",
        "db": "BID",
        "id": "107051"
      },
      {
        "date": "2018-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      },
      {
        "date": "2021-06-22T15:20:21.983000",
        "db": "NVD",
        "id": "CVE-2017-6225"
      },
      {
        "date": "2018-02-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Brocade Fabric OS Vulnerable to cross-site scripting",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012605"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-253"
      }
    ],
    "trust": 0.6
  }
}

var-200409-0059
Vulnerability from variot

Engenio/LSI Logic storage controllers, as used in products such as Storagetek D280, and IBM DS4100 (formerly FastT 100) and Brocade SilkWorm Switches, allow remote attackers to cause a denial of service (freeze and possible data corruption) via crafted TCP packets. It is reported that hardware based on Engenio Storage Controllers are prone to a remote denial of service vulnerability. This could also result reportedly result in unrecoverable corruption of data. Affected hardware includes Storagetek D280, and IBM DS4100 (formerly FastT 100) and Brocade SilkWorm Switches. Other devices may be affected such as other Storagetek and IBM FastT storage controllers, SGI, and Teradata storage controllers though this has not confirmed. The problem may exist in the underlying vxWorks operating system though this has also not been confirmed

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-200409-0059",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "silkworm fiber channel switch",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "2050"
      },
      {
        "model": "silkworm fiber channel switch",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "2040"
      },
      {
        "model": "silkworm fiber channel switch",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "2010"
      },
      {
        "model": "silkworm",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "3900"
      },
      {
        "model": "silkworm",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "3850"
      },
      {
        "model": "silkworm",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "3800"
      },
      {
        "model": "silkworm",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "3250"
      },
      {
        "model": "silkworm",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "brocade",
        "version": "3200"
      },
      {
        "model": "storage controller",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "engenio",
        "version": "5884"
      },
      {
        "model": "storage controller",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "engenio",
        "version": "4884"
      },
      {
        "model": "storage controller",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "engenio",
        "version": "2882"
      },
      {
        "model": "storage controller",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "engenio",
        "version": "2822"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "2.1.2"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "2.2"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "3.1"
      },
      {
        "model": "d280",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "storagetek",
        "version": "*"
      },
      {
        "model": "ds4100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "ibm",
        "version": "*"
      },
      {
        "model": "d280",
        "scope": null,
        "trust": 0.3,
        "vendor": "storagetek",
        "version": null
      },
      {
        "model": "ds4100",
        "scope": null,
        "trust": 0.3,
        "vendor": "ibm",
        "version": null
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "brocade",
        "version": "3.1"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "brocade",
        "version": "2.2"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "brocade",
        "version": "2.1.2"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "11108"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm:3200:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm:3250:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:engenio:storage_controller:2882:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:engenio:storage_controller:4884:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm_fiber_channel_switch:2040:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm_fiber_channel_switch:2050:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:engenio:storage_controller:2822:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:2.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:3.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm:3900:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm_fiber_channel_switch:2010:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:storagetek:d280:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:2.1.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm:3800:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:brocade:silkworm:3850:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:engenio:storage_controller:5884:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:ibm:ds4100:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Discovery is credited to Frank Denis.",
    "sources": [
      {
        "db": "BID",
        "id": "11108"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2004-1663",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-10093",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2004-1663",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-200409-010",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-10093",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10093"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Engenio/LSI Logic storage controllers, as used in products such as Storagetek D280, and IBM DS4100 (formerly FastT 100) and Brocade SilkWorm Switches, allow remote attackers to cause a denial of service (freeze and possible data corruption) via crafted TCP packets. It is reported that hardware based on Engenio Storage Controllers are prone to a remote denial of service vulnerability.  This could also result reportedly result in unrecoverable corruption of data. \nAffected hardware includes Storagetek D280, and IBM DS4100 (formerly FastT 100) and Brocade SilkWorm Switches.  Other devices may be affected such as other Storagetek and IBM FastT storage controllers, SGI, and Teradata storage controllers though this has not confirmed.  The problem may exist in the underlying vxWorks operating system though this has also not been confirmed",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "db": "BID",
        "id": "11108"
      },
      {
        "db": "VULHUB",
        "id": "VHN-10093"
      }
    ],
    "trust": 1.26
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "11108",
        "trust": 2.0
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1663",
        "trust": 1.7
      },
      {
        "db": "SECUNIA",
        "id": "12464",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-10093",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10093"
      },
      {
        "db": "BID",
        "id": "11108"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "id": "VAR-200409-0059",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10093"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T13:21:14.643000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/11108"
      },
      {
        "trust": 1.7,
        "url": "http://secunia.com/advisories/12464"
      },
      {
        "trust": 1.7,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/17290"
      },
      {
        "trust": 1.6,
        "url": "http://marc.info/?l=bugtraq\u0026m=109435831811484\u0026w=2"
      },
      {
        "trust": 0.3,
        "url": "http://www.storagetek.com/products/category_page2004.html"
      },
      {
        "trust": 0.3,
        "url": "http://www.engenio.com/"
      },
      {
        "trust": 0.3,
        "url": "http://www.storage.ibm.com/disk/fastt/"
      },
      {
        "trust": 0.3,
        "url": "/archive/1/374246"
      },
      {
        "trust": 0.1,
        "url": "http://marc.info/?l=bugtraq\u0026amp;m=109435831811484\u0026amp;w=2"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10093"
      },
      {
        "db": "BID",
        "id": "11108"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-10093"
      },
      {
        "db": "BID",
        "id": "11108"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2004-09-04T00:00:00",
        "db": "VULHUB",
        "id": "VHN-10093"
      },
      {
        "date": "2004-09-04T00:00:00",
        "db": "BID",
        "id": "11108"
      },
      {
        "date": "2004-09-04T04:00:00",
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "date": "2004-09-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-07-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-10093"
      },
      {
        "date": "2004-09-04T00:00:00",
        "db": "BID",
        "id": "11108"
      },
      {
        "date": "2021-06-22T15:19:34.840000",
        "db": "NVD",
        "id": "CVE-2004-1663"
      },
      {
        "date": "2021-06-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "LSI Logic storage controllers Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200409-010"
      }
    ],
    "trust": 0.6
  }
}

var-201705-1683
Vulnerability from variot

A privilege escalation vulnerability in Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) releases earlier than v7.4.1d and v8.0.1b could allow an authenticated attacker to elevate the privileges of user accounts accessing the system via command line interface. With affected versions, non-root users can gain root access with a combination of shell commands and parameters. HP StoreFabric B-series Switches are prone to a remote privilege-escalation vulnerability. A remote attacker can leverage this issue to gain elevated privileges within the context of affected system. HP StoreFabric B-series Switches FOS versions prior to 7.4.1d and 8.0.1b are vulnerable. -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256

Note: the current version of the following document is available here: https://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbst03739en_us

SUPPORT COMMUNICATION - SECURITY BULLETIN

Document ID: hpesbst03739en_us Version: 1

HPESBST03739 rev.1 - HPE StoreFabric B-series Switches, Remote Elevation of Privilege

NOTICE: The information in this Security Bulletin should be acted upon as soon as possible.

Release Date: 2017-05-04 Last Updated: 2017-05-04

Potential Security Impact: Remote: Elevation of Privilege

Source: Hewlett Packard Enterprise, Product Security Response Team

VULNERABILITY SUMMARY A potential security vulnerability with Brocade Fabric OS (FOS) has been addressed in HPE StoreFabric B-series Switches. The vulnerability could be remotely exploited to allow an authenticated attacker to elevate the privileges of user accounts. - CVE-2016-8202

SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed.

  • StoreFabric B-series Switches - All versions prior to FOS v7.4.1d and v8.0.1b

BACKGROUND

CVSS Base Metrics ================= Reference, CVSS V3 Score/Vector, CVSS V2 Score/Vector

CVE-2016-8202
  8.3 CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
  8.5 (AV:N/AC:M/Au:S/C:C/I:C/A:C)

Information on CVSS is documented in
HPE Customer Notice HPSN-2008-002 here:

https://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01345499

RESOLUTION

HPE has made the following software update information available to resolve the vulnerability in HPE StoreFabric B-series Switches running Brocade Fabric OS (FOS).

    • FOS v7.4.1d and FOS v8.0.1b or later have hardened the command line interfaces by tightening access permissions and removed commands that potentially can be used to poke and exploit the CLI to gain unauthorized privileges.

    NOTE: The B-series switch streams list all the currently active FOS versions. For the latest productsupport information, see the HPE Single Point of Connectivity Knowledge (SPOCK) website. A valid HPE Passport account is required to access this website:

    http://www.hpe.com/storage/spock

HISTORY Version:1 (rev.1) - 4 May 2017 Initial release

Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy.

Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com.

Report: To report a potential security vulnerability for any HPE supported product: Web form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com

Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice

Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive

Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB.

3C = 3COM 3P = 3rd Party Software GN = HPE General Software HF = HPE Hardware and Firmware MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PV = ProCurve ST = Storage Software UX = HP-UX

Copyright 2016 Hewlett Packard Enterprise

Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise and the names of Hewlett Packard Enterprise products referenced herein are trademarks of Hewlett Packard Enterprise in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1

iQEcBAEBCAAGBQJZC2djAAoJELXhAxt7SZaiWE4H/2rXH73B6pVmM09pZyef8yZM x5/bkITU4wxjxfV+h8LWFZMsOj7WL7g/Wgq+qJKc7QPOj31E1viTp0s+es1eiF5U 72vPzOR39cqEUALYXFB9qPGTg3TS+NtkxMJnY20iE08E5sQZGX3hqBecrPOL93f2 BQlHvJb0JJ/Jy+J76JLwiYtr2sjguBCJL1qUKhZCJJ/H05qOdCBW5u0ukbWi4Bq8 IdEOh6p485WaZpRKglGBL1KHO/YMwbfDDppeQNa+a/FH2wen7qe5+a+vtu2cfxdp OC+B9aamDYRTg3TUybEoXsuuLoGLh6NUTqHilOA74d0KQPJLQJ7ZmkdkfAe8n6g= =UVxE -----END PGP SIGNATURE-----

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201705-1683",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "brocade",
        "version": "8.0.1b"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.0.1"
      },
      {
        "model": "fabric operating system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "7.4.1c"
      },
      {
        "model": "fabric os",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "brocade",
        "version": "7.4.1d"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "7.4.1c"
      },
      {
        "model": "storefabric b-series switches",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "hp",
        "version": "8.0"
      },
      {
        "model": "storefabric b-series switches",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "hp",
        "version": "7.0.1"
      },
      {
        "model": "storefabric b-series switches 8.0.1a",
        "scope": null,
        "trust": 0.3,
        "vendor": "hp",
        "version": null
      },
      {
        "model": "storefabric b-series switches",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "hp",
        "version": "8.0.1"
      },
      {
        "model": "storefabric b-series switches",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "hp",
        "version": "7.0"
      },
      {
        "model": "storefabric b-series switches 8.0.1b",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "hp",
        "version": null
      },
      {
        "model": "storefabric b-series switches 7.4.1d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "hp",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "98332"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "7.4.1c",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "98332"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2016-8202",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": true,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2016-8202",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2016-8202",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2016-8202",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201705-367",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A privilege escalation vulnerability in Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) releases earlier than v7.4.1d and v8.0.1b could allow an authenticated attacker to elevate the privileges of user accounts accessing the system via command line interface. With affected versions, non-root users can gain root access with a combination of shell commands and parameters. HP StoreFabric B-series Switches are prone to a remote privilege-escalation vulnerability. \nA remote attacker can leverage this issue to gain elevated privileges within the context of affected system. \nHP StoreFabric B-series Switches FOS versions prior to 7.4.1d and 8.0.1b are vulnerable. -----BEGIN PGP SIGNED MESSAGE-----\nHash: SHA256\n\nNote: the current version of the following document is available here:\nhttps://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbst03739en_us\n\nSUPPORT COMMUNICATION - SECURITY BULLETIN\n\nDocument ID: hpesbst03739en_us\nVersion: 1\n\nHPESBST03739 rev.1 - HPE StoreFabric B-series Switches, Remote Elevation of\nPrivilege\n\nNOTICE: The information in this Security Bulletin should be acted upon as\nsoon as possible. \n\nRelease Date: 2017-05-04\nLast Updated: 2017-05-04\n\nPotential Security Impact: Remote: Elevation of Privilege\n\nSource: Hewlett Packard Enterprise, Product Security Response Team\n\nVULNERABILITY SUMMARY\nA potential security vulnerability with Brocade Fabric OS (FOS) has been\naddressed in HPE StoreFabric B-series Switches. The vulnerability could be\nremotely exploited to allow an authenticated attacker to elevate the\nprivileges of user accounts. \n  - CVE-2016-8202\n\nSUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. \n\n  - StoreFabric B-series Switches - All versions prior to FOS v7.4.1d and\nv8.0.1b\n\nBACKGROUND\n\n  CVSS Base Metrics\n  =================\n  Reference, CVSS V3 Score/Vector, CVSS V2 Score/Vector\n\n    CVE-2016-8202\n      8.3 CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\n      8.5 (AV:N/AC:M/Au:S/C:C/I:C/A:C)\n\n    Information on CVSS is documented in\n    HPE Customer Notice HPSN-2008-002 here:\n\nhttps://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01345499\n\nRESOLUTION\n\nHPE has made the following software update information available to resolve\nthe vulnerability in HPE StoreFabric B-series Switches running Brocade Fabric\nOS (FOS). \n\n- - FOS v7.4.1d and FOS v8.0.1b or later have hardened the command line\ninterfaces by tightening access permissions and removed commands that\npotentially can be used to poke and exploit the CLI to gain unauthorized\nprivileges. \n   \n    **NOTE:** The B-series switch streams list all the currently active FOS\nversions. For the latest productsupport information, see the HPE Single\nPoint of Connectivity Knowledge (SPOCK) website. A valid HPE Passport account\nis required to access this website:\n\n    \u003chttp://www.hpe.com/storage/spock\u003e\n\nHISTORY\nVersion:1 (rev.1) - 4 May 2017 Initial release\n\nThird Party Security Patches: Third party security patches that are to be\ninstalled on systems running Hewlett Packard Enterprise (HPE) software\nproducts should be applied in accordance with the customer\u0027s patch management\npolicy. \n\nSupport: For issues about implementing the recommendations of this Security\nBulletin, contact normal HPE Services support channel. For other issues about\nthe content of this Security Bulletin, send e-mail to security-alert@hpe.com. \n\nReport: To report a potential security vulnerability for any HPE supported\nproduct:\n  Web form: https://www.hpe.com/info/report-security-vulnerability\n  Email: security-alert@hpe.com\n\nSubscribe: To initiate a subscription to receive future HPE Security Bulletin\nalerts via Email: http://www.hpe.com/support/Subscriber_Choice\n\nSecurity Bulletin Archive: A list of recently released Security Bulletins is\navailable here: http://www.hpe.com/support/Security_Bulletin_Archive\n\nSoftware Product Category: The Software Product Category is represented in\nthe title by the two characters following HPSB. \n\n3C = 3COM\n3P = 3rd Party Software\nGN = HPE General Software\nHF = HPE Hardware and Firmware\nMU = Multi-Platform Software\nNS = NonStop Servers\nOV = OpenVMS\nPV = ProCurve\nST = Storage Software\nUX = HP-UX\n\nCopyright 2016 Hewlett Packard Enterprise\n\nHewlett Packard Enterprise shall not be liable for technical or editorial\nerrors or omissions contained herein. The information provided is provided\n\"as is\" without warranty of any kind. To the extent permitted by law, neither\nHP or its affiliates, subcontractors or suppliers will be liable for\nincidental,special or consequential damages including downtime cost; lost\nprofits; damages relating to the procurement of substitute products or\nservices; or damages for loss of data, or software restoration. The\ninformation in this document is subject to change without notice. Hewlett\nPackard Enterprise and the names of Hewlett Packard Enterprise products\nreferenced herein are trademarks of Hewlett Packard Enterprise in the United\nStates and other countries. Other product and company names mentioned herein\nmay be trademarks of their respective owners. \n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1\n\niQEcBAEBCAAGBQJZC2djAAoJELXhAxt7SZaiWE4H/2rXH73B6pVmM09pZyef8yZM\nx5/bkITU4wxjxfV+h8LWFZMsOj7WL7g/Wgq+qJKc7QPOj31E1viTp0s+es1eiF5U\n72vPzOR39cqEUALYXFB9qPGTg3TS+NtkxMJnY20iE08E5sQZGX3hqBecrPOL93f2\nBQlHvJb0JJ/Jy+J76JLwiYtr2sjguBCJL1qUKhZCJJ/H05qOdCBW5u0ukbWi4Bq8\nIdEOh6p485WaZpRKglGBL1KHO/YMwbfDDppeQNa+a/FH2wen7qe5+a+vtu2cfxdp\nOC+B9aamDYRTg3TUybEoXsuuLoGLh6NUTqHilOA74d0KQPJLQJ7ZmkdkfAe8n6g=\n=UVxE\n-----END PGP SIGNATURE-----\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "BID",
        "id": "98332"
      },
      {
        "db": "PACKETSTORM",
        "id": "142444"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2016-8202",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "98332",
        "trust": 1.3
      },
      {
        "db": "SECTRACK",
        "id": "1038401",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367",
        "trust": 0.6
      },
      {
        "db": "PACKETSTORM",
        "id": "142444",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "98332"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "PACKETSTORM",
        "id": "142444"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "id": "VAR-201705-1683",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.25
  },
  "last_update_date": "2023-12-18T13:29:19.009000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "BSA-2017-208",
        "trust": 0.8,
        "url": "https://www.brocade.com/content/dam/common/documents/content-types/security-bulletin/brocade-security-advisory-2017-208.htm"
      },
      {
        "title": "HPESBST03739",
        "trust": 0.8,
        "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026docid=emr_na-hpesbst03739en_us"
      },
      {
        "title": "Brocade Fibre Channel SAN product Brocade Fabric OS Fixes for permission permissions and access control vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=69918"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-264",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "http://www.securityfocus.com/bid/98332"
      },
      {
        "trust": 1.0,
        "url": "http://www.securitytracker.com/id/1038401"
      },
      {
        "trust": 1.0,
        "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026docid=emr_na-hpesbst03739en_us"
      },
      {
        "trust": 1.0,
        "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2017-208"
      },
      {
        "trust": 0.9,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2016-8202"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-8202"
      },
      {
        "trust": 0.6,
        "url": "https://www.brocade.com/content/dam/common/documents/content-types/security-bulletin/brocade-security-advisory-2017-208.htm"
      },
      {
        "trust": 0.4,
        "url": "https://h20564.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-hpesbst03739en_us"
      },
      {
        "trust": 0.3,
        "url": "http://www.hp.com/"
      },
      {
        "trust": 0.1,
        "url": "http://www.hpe.com/support/security_bulletin_archive"
      },
      {
        "trust": 0.1,
        "url": "https://www.hpe.com/info/report-security-vulnerability"
      },
      {
        "trust": 0.1,
        "url": "https://h20564.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-c01345499"
      },
      {
        "trust": 0.1,
        "url": "http://www.hpe.com/storage/spock\u003e"
      },
      {
        "trust": 0.1,
        "url": "http://www.hpe.com/support/subscriber_choice"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "98332"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "PACKETSTORM",
        "id": "142444"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "98332"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "db": "PACKETSTORM",
        "id": "142444"
      },
      {
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-04T00:00:00",
        "db": "BID",
        "id": "98332"
      },
      {
        "date": "2017-06-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "date": "2017-05-10T14:05:13",
        "db": "PACKETSTORM",
        "id": "142444"
      },
      {
        "date": "2017-05-08T18:29:00.217000",
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-23T16:23:00",
        "db": "BID",
        "id": "98332"
      },
      {
        "date": "2017-06-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      },
      {
        "date": "2021-06-22T15:20:05.800000",
        "db": "NVD",
        "id": "CVE-2016-8202"
      },
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Brocade Fibre Channel SAN Run on product  Brocade Fabric OS Vulnerability in which privileges are elevated",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2016-008578"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "permissions and access control",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-367"
      }
    ],
    "trust": 0.6
  }
}

var-200002-0095
Vulnerability from variot

In a number of network devices/operating systems, some default communites are world-writeable and therefore allow remote users to configure properties of the device/OS without any authorization (other than knowledge of the community name). Some of the common default communities/vendors are: public (ascend,cisco,bay networks (nortel),microsoft,sun,3com, aix) private (cisco,bay networks (nortel),microsoft,3com, brocade, aix, netapp) write (ascend, very common) "all private" (sun) monitor (3com) manager (3com) security (3com) OrigEquipMfr (brocade) "Secret C0de" (brocade) admin default password tivoli openview community snmp snmpd system (aix, others) the name of the router (ie, 'gate') The attacks can include manipulating routing tables and corrupting ARP caches, which can lead to further compromise. This type of vulnerability has been seen for quite some time; more information on it is listed in the credit section. NOTE: There may be more products shipping with default read/writeable communities. If you have any more information on what may be vulnerable (more specific firmware versions or corrections), email <vuldb@securityfocus.com>.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-200002-0095",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "router",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xyplex",
        "version": "6.1.1"
      },
      {
        "model": "solaris",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "sun",
        "version": "2.6"
      },
      {
        "model": "windows nt",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "microsoft",
        "version": "4.0"
      },
      {
        "model": "windows",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "microsoft",
        "version": "98"
      },
      {
        "model": "matchbox router",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cray",
        "version": "2.0.1"
      },
      {
        "model": "ios",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "11.2"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "brocade",
        "version": "2.1.2"
      },
      {
        "model": "coltsoho",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ascom",
        "version": "2.0.21"
      },
      {
        "model": "solaris",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "sun",
        "version": "7.0"
      },
      {
        "model": "windows nt sp4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "microsoft",
        "version": "4.0"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "This was posted to Bugtraq by Michal Zalewski on Feb 15, 2000.\n\n Alhambra wrote an article about this for issue 50 of Phrack. It is linked to below.\n\n Information regarding default communities for Brocade fabric switches was provided by Jonathan Clemens \u003cj",
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ],
    "trust": 0.3
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In a number of network devices/operating systems, some default communites are world-writeable and therefore allow remote users to configure properties of the device/OS without any authorization (other than knowledge of the community name).\nSome of the common default communities/vendors are:\npublic (ascend,cisco,bay networks (nortel),microsoft,sun,3com, aix)\nprivate (cisco,bay networks (nortel),microsoft,3com, brocade, aix, netapp)\nwrite (ascend, very common)\n\"all private\" (sun)\nmonitor (3com)\nmanager (3com)\nsecurity (3com)\nOrigEquipMfr (brocade)\n\"Secret C0de\" (brocade)\nadmin\ndefault\npassword\ntivoli\nopenview\ncommunity\nsnmp\nsnmpd\nsystem (aix, others)\nthe name of the router (ie, \u0027gate\u0027)\nThe attacks can include manipulating routing tables and corrupting ARP caches, which can lead to further compromise. This type of vulnerability has been seen for quite some time; more information on it is listed in the credit section.\nNOTE: There may be more products shipping with default read/writeable communities. If you have any more information on what may be vulnerable (more specific firmware versions or corrections), email \u0026lt;vuldb@securityfocus.com\u0026gt;.",
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ],
    "trust": 0.3
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "986",
        "trust": 0.3
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ]
  },
  "id": "VAR-200002-0095",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.7857143
  },
  "last_update_date": "2022-05-17T01:47:40.143000Z",
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 0.3,
        "url": "http://www.phrack.com/issues.html?issue=50\u0026id=7#article"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "986"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2000-02-15T00:00:00",
        "db": "BID",
        "id": "986"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2008-04-16T00:29:00",
        "db": "BID",
        "id": "986"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "network",
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ],
    "trust": 0.3
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple Vendor SNMP World Writeable Community Vulnerability",
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ],
    "trust": 0.3
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unknown",
    "sources": [
      {
        "db": "BID",
        "id": "986"
      }
    ],
    "trust": 0.3
  }
}

var-201802-0641
Vulnerability from variot

A vulnerability in the IPv6 stack on Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) versions before 7.4.2b, 8.1.2 and 8.2.0 could allow an attacker to cause a denial of service (CPU consumption and device hang) condition by sending crafted Router Advertisement (RA) messages to a targeted system. Brocade Fabric OS (FOS) Contains a resource management vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. BrocadeFibreChannelSANproducts are Brocade switches and BrocadeFabricOS (FOS) is an embedded system running on them. Security vulnerabilities exist in BrocadeFibreChannelSAN products prior to BrocadeFOS7.4.2b, pre-8.1.2, and pre-8.0.6 IPv6 stacks. Broadcom Fabric OS is prone to a remote denial-of-service vulnerability. Exploiting this issue allows remote attackers to cause a denial-of-service condition due to excessive CPU consumption. Versions prior to Broadcom Fabric OS 7.4.2b, 8.1.2 and 8.2.0 are vulnerable

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201802-0641",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fabric operating system",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "7.4.2b"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.0.1"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.1.1"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.1.2"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "brocade",
        "version": "8.0.2b2"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.0.2"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.0.0"
      },
      {
        "model": "fabric operating system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "broadcom",
        "version": "8.1.0"
      },
      {
        "model": "fabric os",
        "scope": null,
        "trust": 0.8,
        "vendor": "brocade",
        "version": null
      },
      {
        "model": "fibre channel san \u003c7.4.2b",
        "scope": null,
        "trust": 0.6,
        "vendor": "brocade",
        "version": null
      },
      {
        "model": "fibre channel san",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.2"
      },
      {
        "model": "fibre channel san",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.2.0"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.1a"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": null
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.2a"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "2.1.2"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "3.1"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.0c"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "5.0.5b"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "2.2"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.0"
      },
      {
        "model": "fabric os",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "brocade",
        "version": "8.1.1"
      },
      {
        "model": "brocade fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.1.1"
      },
      {
        "model": "brocade fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.0.2"
      },
      {
        "model": "brocade fabric os",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "7.4.2"
      },
      {
        "model": "brocade fabric os",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.2"
      },
      {
        "model": "brocade fabric os",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": "8.1.2"
      },
      {
        "model": "brocade fabric os 7.4.2b",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "broadcom",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "BID",
        "id": "107056"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.1.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.1.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.4.2b",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.1.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.1.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.0.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:brocade:fabric_os:8.0.2b2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:broadcom:fabric_operating_system:8.1.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "107056"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-6227",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 6.1,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-6227",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2018-06324",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-6227",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-6227",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-06324",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201802-252",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability in the IPv6 stack on Brocade Fibre Channel SAN products running Brocade Fabric OS (FOS) versions before 7.4.2b, 8.1.2 and 8.2.0 could allow an attacker to cause a denial of service (CPU consumption and device hang) condition by sending crafted Router Advertisement (RA) messages to a targeted system. Brocade Fabric OS (FOS) Contains a resource management vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. BrocadeFibreChannelSANproducts are Brocade switches and BrocadeFabricOS (FOS) is an embedded system running on them. Security vulnerabilities exist in BrocadeFibreChannelSAN products prior to BrocadeFOS7.4.2b, pre-8.1.2, and pre-8.0.6 IPv6 stacks. Broadcom Fabric OS is prone to a remote denial-of-service vulnerability. \nExploiting this issue allows remote attackers to cause a denial-of-service condition due to excessive CPU consumption. \nVersions prior to Broadcom Fabric OS 7.4.2b, 8.1.2 and 8.2.0 are vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "BID",
        "id": "107056"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-6227",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252",
        "trust": 0.6
      },
      {
        "db": "BID",
        "id": "107056",
        "trust": 0.3
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "BID",
        "id": "107056"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "id": "VAR-201802-0641",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:24:11.185000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "BSA-2018-526",
        "trust": 0.8,
        "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-526"
      },
      {
        "title": "BrocadeFibreChannelSAN product BrocadeFabricOS denial of service vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/123357"
      },
      {
        "title": "Brocade Fibre Channel SAN product Brocade Fabric OS Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=78366"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-399",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-526"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6227"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-6227"
      },
      {
        "trust": 0.6,
        "url": "http://www.brocade.com/content/dam/common/documents/content-types/security-bulletin/brocade-security-advisory-2018-526.htm"
      },
      {
        "trust": 0.3,
        "url": "http://www.broadcom.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "BID",
        "id": "107056"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "db": "BID",
        "id": "107056"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "date": "2018-01-17T00:00:00",
        "db": "BID",
        "id": "107056"
      },
      {
        "date": "2018-03-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "date": "2018-02-08T22:29:00.270000",
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "date": "2018-02-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-06324"
      },
      {
        "date": "2018-01-17T00:00:00",
        "db": "BID",
        "id": "107056"
      },
      {
        "date": "2018-03-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      },
      {
        "date": "2021-06-22T15:20:34.403000",
        "db": "NVD",
        "id": "CVE-2017-6227"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Brocade Fabric OS Resource management vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012501"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-252"
      }
    ],
    "trust": 0.6
  }
}