cve-2024-7517
Vulnerability from cvelistv5
Published
2024-11-21 05:53
Modified
2024-11-21 05:55
Summary
Privileged escalation via crafted use of portcfg command
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS versions before 9.2.0c, and 9.2.1 through 9.2.1a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\u003c/p\u003e\u003cp\u003eThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack.\u003c/p\u003e"
            }
          ],
          "value": "A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\n\nThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T05:55:00.417Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25071"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Privileged escalation via crafted use of portcfg command",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-7517",
    "datePublished": "2024-11-21T05:53:34.442Z",
    "dateReserved": "2024-08-05T22:49:54.345Z",
    "dateUpdated": "2024-11-21T05:55:00.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.