cve-2023-31431
Vulnerability from cvelistv5
Published
2023-08-01 23:23
Modified
2024-08-02 14:53
Summary
A buffer overflow vulnerability in “diagstatus” command
Impacted products
BrocadeFabric OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:31.082Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22384"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Fabric OS",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade Fabric OS v9.1.1c, v9.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A buffer overflow vulnerability in \u201cdiagstatus\u201d command in Brocade Fabric OS before Brocade Fabric v9.2.0 and v9.1.1c could allow an authenticated user to crash the Brocade Fabric OS switch leading to a denial of service.\u003cbr\u003e\n\n"
            }
          ],
          "value": "A buffer overflow vulnerability in \u201cdiagstatus\u201d command in Brocade Fabric OS before Brocade Fabric v9.2.0 and v9.1.1c could allow an authenticated user to crash the Brocade Fabric OS switch leading to a denial of service.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-25",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-25 Forced Deadlock"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T23:23:18.522Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/22384"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230908-0007/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A buffer overflow vulnerability in \u201cdiagstatus\u201d command",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31431",
    "datePublished": "2023-08-01T23:23:18.522Z",
    "dateReserved": "2023-04-28T00:14:58.125Z",
    "dateUpdated": "2024-08-02T14:53:31.082Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-31431\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2023-08-02T00:15:17.410\",\"lastModified\":\"2023-12-21T01:38:25.140\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A buffer overflow vulnerability in \u201cdiagstatus\u201d command in Brocade Fabric OS before Brocade Fabric v9.2.0 and v9.1.1c could allow an authenticated user to crash the Brocade Fabric OS switch leading to a denial of service.\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de desbordamiento de b\u00fafer en el comando \\\"diagstatus\\\" en Brocade Fabric OS antes de Brocade Fabric v9.2.0 y v9.1.1c podr\u00eda permitir a un usuario autenticado bloquear el conmutador Brocade Fabric OS provocando una denegaci\u00f3n de servicio.\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"sirt@brocade.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]},{\"source\":\"sirt@brocade.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:brocade_fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.1.1c\",\"matchCriteriaId\":\"04156705-D7B0-4819-9877-1896AE211A87\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:brocade_fabric_operating_system:9.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"309D6E49-58B0-4360-9EB9-AAD393E9995F\"}]}]}],\"references\":[{\"url\":\"https://security.netapp.com/advisory/ntap-20230908-0007/\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.broadcom.com/external/content/SecurityAdvisories/0/22384\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.