All the vulnerabilites related to Fortinet - FortiConverter
cve-2022-33877
Vulnerability from cvelistv5
Published
2023-06-13 08:41
Modified
2024-10-23 14:27
Summary
An incorrect default permission [CWE-276] vulnerability in FortiClient (Windows) versions 7.0.0 through 7.0.6 and 6.4.0 through 6.4.8 and FortiConverter (Windows) versions 6.2.0 through 6.2.1, 7.0.0 and all versions of 6.0.0 may allow a local authenticated attacker to tamper with files in the installation folder, if FortiClient or FortiConverter is installed in an insecure folder.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:09:22.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-22-229",
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-22-229"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-33877",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T14:11:03.300339Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T14:27:28.404Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiConverter",
          "vendor": "Fortinet",
          "versions": [
            {
              "status": "affected",
              "version": "7.0.0"
            },
            {
              "lessThanOrEqual": "6.2.1",
              "status": "affected",
              "version": "6.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.0.3",
              "status": "affected",
              "version": "6.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FortiClientWindows",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.0.6",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.4.8",
              "status": "affected",
              "version": "6.4.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An incorrect default permission [CWE-276] vulnerability in FortiClient (Windows) versions 7.0.0 through 7.0.6 and 6.4.0 through 6.4.8 and FortiConverter (Windows) versions 6.2.0 through 6.2.1, 7.0.0 and all versions of 6.0.0 may allow a local authenticated attacker to tamper with files in the installation folder, if FortiClient or FortiConverter is installed in an insecure folder."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:X/RC:X",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "Improper access control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-13T08:41:40.721Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.com/psirt/FG-IR-22-229",
          "url": "https://fortiguard.com/psirt/FG-IR-22-229"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiClientWindows version 7.0.7 or above\r\nPlease upgrade to FortiClientWindows version 6.4.9 or above\nPlease upgrade to FortiConverter version 7.0.1 or above\r\nPlease upgrade to FortiConverter version 6.2.2 or above\n\u00a0"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2022-33877",
    "datePublished": "2023-06-13T08:41:40.721Z",
    "dateReserved": "2022-06-16T11:14:43.765Z",
    "dateUpdated": "2024-10-23T14:27:28.404Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}