All the vulnerabilites related to Mitsubishi Electric Corporation - GOT2000 Series GT25 model
cve-2023-0525
Vulnerability from cvelistv5
Published
2023-08-03 23:42
Modified
2024-10-18 20:11
Severity ?
EPSS score ?
Summary
Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:17:49.235Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-008_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95285923/index.html" }, { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-02" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-0525", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-18T20:11:02.631860Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-18T20:11:17.005Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GOT2000 Series GT27 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT25 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT23 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT21 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT SIMPLE Series GS25 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT SIMPLE Series GS21 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1 (GOT2000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.295H and prior" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.295H and prior" } ] } ], "datePublic": "2023-08-03T03:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled." } ], "value": "Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-261", "description": "CWE-261 Weak Encoding for Password", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-03T23:42:43.290Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-008_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU95285923/index.html" }, { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-02" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-0525", "datePublished": "2023-08-03T23:42:43.290Z", "dateReserved": "2023-01-27T05:27:17.859Z", "dateUpdated": "2024-10-18T20:11:17.005Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-40268
Vulnerability from cvelistv5
Published
2023-02-02 07:13
Modified
2024-08-03 12:14
Severity ?
EPSS score ?
Summary
Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to lead legitimate users to perform unintended operations through clickjacking.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:14:40.024Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-021_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU91222434/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GOT2000 Series GT27 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.14.000 to 01.47.000" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT25 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.14.000 to 01.47.000" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.265B to 1.285X" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to lead legitimate users to perform unintended operations through clickjacking." } ], "value": "Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to lead legitimate users to perform unintended operations through clickjacking." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1021", "description": "CWE-1021 Improper Restriction of Rendered UI Layers or Frames", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-02T07:13:18.109Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-021_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU91222434/index.html" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2022-40268", "datePublished": "2023-02-02T07:13:18.109Z", "dateReserved": "2022-09-08T19:40:16.931Z", "dateUpdated": "2024-08-03T12:14:40.024Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-40269
Vulnerability from cvelistv5
Published
2023-02-02 07:17
Modified
2024-08-03 12:14
Severity ?
EPSS score ?
Summary
Authentication Bypass by Spoofing vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to disclose sensitive information from users' browsers or spoof legitimate users by abusing inappropriate HTML attributes.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:14:40.021Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-021_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU91222434/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GOT2000 Series GT27 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.14.000 to 01.47.000" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT25 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.14.000 to 01.47.000" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.265B to 1.285X" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Authentication Bypass by Spoofing vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to disclose sensitive information from users\u0027 browsers or spoof legitimate users by abusing inappropriate HTML attributes." } ], "value": "Authentication Bypass by Spoofing vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to disclose sensitive information from users\u0027 browsers or spoof legitimate users by abusing inappropriate HTML attributes." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-290", "description": "CWE-290 Authentication Bypass by Spoofing", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-02T07:17:09.894Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-021_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU91222434/index.html" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2022-40269", "datePublished": "2023-02-02T07:17:09.894Z", "dateReserved": "2022-09-08T19:40:16.932Z", "dateUpdated": "2024-08-03T12:14:40.021Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }