cve-2023-0525
Vulnerability from cvelistv5
Published
2023-08-03 23:42
Modified
2024-10-18 20:11
Severity ?
EPSS score ?
Summary
Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled.
References
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU95285923/index.html | Third Party Advisory | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-02 | Third Party Advisory, US Government Resource | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-008_en.pdf | Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:17:49.235Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-008_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95285923/index.html" }, { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-02" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-0525", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-18T20:11:02.631860Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-18T20:11:17.005Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GOT2000 Series GT27 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT25 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT23 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT2000 Series GT21 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT SIMPLE Series GS25 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GOT SIMPLE Series GS21 model", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01.49.000 and prior" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1 (GOT2000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.295H and prior" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.295H and prior" } ] } ], "datePublic": "2023-08-03T03:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled." } ], "value": "Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-261", "description": "CWE-261 Weak Encoding for Password", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-03T23:42:43.290Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-008_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU95285923/index.html" }, { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-02" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-0525", "datePublished": "2023-08-03T23:42:43.290Z", "dateReserved": "2023-01-27T05:27:17.859Z", "dateUpdated": "2024-10-18T20:11:17.005Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-0525\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2023-08-04T00:15:10.300\",\"lastModified\":\"2023-08-10T14:59:59.350\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49.000 and prior, GS21 model versions 01.49.000 and prior, GT Designer3 Version1 (GOT2000) versions 1.295H and prior and GT SoftGOT2000 versions 1.295H and prior allows a remote unauthenticated attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords, in the case of transferring data with GT Designer3 Version1(GOT2000) and GOT2000 Series or GOT SIMPLE Series with the Data Transfer Security function enabled, or in the case of transferring data by the SoftGOT-GOT link function with GT SoftGOT2000 and GOT2000 series with the Data Transfer Security function enabled.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad Weak Encoding for Password en Mitsubishi Electric Corporation GOT2000 Series modelo GT27 versiones 01.49.000 y anteriores, modelo GT25 versiones 01.49.000 y anteriores, modelo GT23 versiones 01.49.000 y anteriores, modelo GT21 versiones 01.49.000 y anteriores, serie GOT SIMPLE modelo GS25 versiones 01.49.000 y anteriores, modelo GS21 versiones 01.49.000 y anteriores, GT Designer3 Version1 (GOT2000) versiones 1.295H y anteriores, y GT SoftGOT2000 versiones 1.295H y anteriores, permite a un atacante remoto no autenticado obtener contrase\u00f1as en texto plano al espiar paquetes que contienen contrase\u00f1as cifradas y descifrar las contrase\u00f1as cifradas. Esto ocurre en el caso de la transferencia de datos con GT Designer3 Version1 (GOT2000) y GOT2000 Series o GOT SIMPLE Series con la funci\u00f3n de Seguridad de Transferencia de Datos habilitada, o en el caso de la transferencia de datos mediante la funci\u00f3n de enlace SoftGOT-GOT con GT SoftGOT2000 y GOT2000 series con la funci\u00f3n de Seguridad de Transferencia de Datos habilitada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-326\"}]},{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-261\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.300n\",\"matchCriteriaId\":\"31EB6AE2-4CEA-4174-A84C-918129A4AB93\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.300n\",\"matchCriteriaId\":\"9778A519-5BF4-417D-9005-53D8CBC1F988\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:gt27:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A7705526-E37E-499C-802F-76D0B1150ED0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:gt27_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.50.000\",\"matchCriteriaId\":\"2266C3EF-91BE-444A-8802-8D089D2AC16B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:gt25:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66A62430-FF89-4342-8F4D-6A94F1ED8F3F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:gt25_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.50.000\",\"matchCriteriaId\":\"FD91AB32-80A2-41F8-B778-20ACE1B288B7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:gt23:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C267FA36-66DB-4B29-9F70-4454888E99AF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:gt23_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.50.000\",\"matchCriteriaId\":\"6ED08B90-2312-4844-B035-DB7E0114524F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:gt21:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D5729FA-349F-4253-AFF1-B48C7AC40593\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:gt21_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.50.000\",\"matchCriteriaId\":\"270CC331-0EBF-4A70-B2EA-6E5B53DC3BD4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:gs25:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"937AC5C4-5DA7-4D5C-84C9-570F83F4915F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:gs25_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.50.000\",\"matchCriteriaId\":\"9F535C12-36D5-40ED-875E-91DDE5B73FAD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:gs21:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E238EA96-8125-4DE2-8E1C-8552C4860113\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:gs21_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.50.000\",\"matchCriteriaId\":\"03AF79C6-7D14-47DD-AB3C-964ADAD86358\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU95285923/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-02\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-008_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.