4 vulnerabilities found for Intellispace Cardiovascular (ISCV) by Philips
CVE-2025-2229 (GCVE-0-2025-2229)
Vulnerability from cvelistv5 – Published: 2025-03-13 18:17 – Updated: 2025-03-17 20:04
VLAI?
Summary
A token is created using the username, current date/time, and a fixed
AES-128 encryption key, which is the same across all installations.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | Intellispace Cardiovascular (ISCV) |
Affected:
0 , ≤ 4.1
(custom)
|
Credits
Joe Dillon reported these vulnerabilities to Philips.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2229",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-13T19:30:31.475698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T19:30:42.059Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intellispace Cardiovascular (ISCV)",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "4.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joe Dillon reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A token is created using the username, current date/time, and a fixed \nAES-128 encryption key, which is the same across all installations."
}
],
"value": "A token is created using the username, current date/time, and a fixed \nAES-128 encryption key, which is the same across all installations."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "CWE-1391",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T20:04:56.100Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhilips recommends the following mitigations:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResolved in ISCV 4.2 build 20589, which was released in May 2019.\u003c/span\u003e\n\n\u003c/li\u003e\n\n\u003cli\u003ePhilips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\u003c/li\u003e\n\u003cli\u003ePlease contact a local Philips sales (service) representative to learn how to engage this upgrade process.\u003c/li\u003e\n\u003cli\u003eFor managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eRefer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\"\u003ePhilips advisory\u003c/a\u003efor more details.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Philips recommends the following mitigations:\n\n\n\n * \n\nResolved in ISCV 4.2 build 20589, which was released in May 2019.\n\n\n\n\n * Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\n\n * Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n * For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
}
],
"source": {
"advisory": "ICSMA-25-072-01",
"discovery": "EXTERNAL"
},
"title": "Philips Intellispace Cardiovascular (ISCV) Use of Weak Credentials",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-2229",
"datePublished": "2025-03-13T18:17:31.256Z",
"dateReserved": "2025-03-11T20:11:49.638Z",
"dateUpdated": "2025-03-17T20:04:56.100Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2230 (GCVE-0-2025-2230)
Vulnerability from cvelistv5 – Published: 2025-03-13 18:14 – Updated: 2025-03-17 20:05
VLAI?
Summary
A flaw exists in the Windows login flow where an AuthContext token can
be exploited for replay attacks and authentication bypass.
Severity ?
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | Intellispace Cardiovascular (ISCV) |
Affected:
0 , ≤ 5.1
(custom)
|
Credits
Joe Dillon reported these vulnerabilities to Philips.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2230",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-13T19:33:45.514056Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T19:34:02.967Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intellispace Cardiovascular (ISCV)",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "5.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joe Dillon reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
}
],
"value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T20:05:56.939Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhilips recommends the following mitigations:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResolved in ISCV 5.2, which was released in September 2020.\u003c/span\u003e\n\n\u003c/li\u003e\n\n\u003cli\u003ePhilips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\u003c/li\u003e\n\u003cli\u003ePlease contact a local Philips sales (service) representative to learn how to engage this upgrade process.\u003c/li\u003e\n\u003cli\u003eFor managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eRefer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\"\u003ePhilips advisory\u003c/a\u003efor more details.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Philips recommends the following mitigations:\n\n\n\n * \n\nResolved in ISCV 5.2, which was released in September 2020.\n\n\n\n\n * Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\n\n * Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n * For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
}
],
"source": {
"advisory": "ICSMA-25-072-01",
"discovery": "EXTERNAL"
},
"title": "Philips Intellispace Cardiovascular (ISCV) Improper Authentication",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-2230",
"datePublished": "2025-03-13T18:14:43.573Z",
"dateReserved": "2025-03-11T20:14:50.017Z",
"dateUpdated": "2025-03-17T20:05:56.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2229 (GCVE-0-2025-2229)
Vulnerability from nvd – Published: 2025-03-13 18:17 – Updated: 2025-03-17 20:04
VLAI?
Summary
A token is created using the username, current date/time, and a fixed
AES-128 encryption key, which is the same across all installations.
Severity ?
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | Intellispace Cardiovascular (ISCV) |
Affected:
0 , ≤ 4.1
(custom)
|
Credits
Joe Dillon reported these vulnerabilities to Philips.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2229",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-13T19:30:31.475698Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T19:30:42.059Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intellispace Cardiovascular (ISCV)",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "4.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joe Dillon reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A token is created using the username, current date/time, and a fixed \nAES-128 encryption key, which is the same across all installations."
}
],
"value": "A token is created using the username, current date/time, and a fixed \nAES-128 encryption key, which is the same across all installations."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "CWE-1391",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T20:04:56.100Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhilips recommends the following mitigations:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResolved in ISCV 4.2 build 20589, which was released in May 2019.\u003c/span\u003e\n\n\u003c/li\u003e\n\n\u003cli\u003ePhilips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\u003c/li\u003e\n\u003cli\u003ePlease contact a local Philips sales (service) representative to learn how to engage this upgrade process.\u003c/li\u003e\n\u003cli\u003eFor managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eRefer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\"\u003ePhilips advisory\u003c/a\u003efor more details.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Philips recommends the following mitigations:\n\n\n\n * \n\nResolved in ISCV 4.2 build 20589, which was released in May 2019.\n\n\n\n\n * Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\n\n * Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n * For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
}
],
"source": {
"advisory": "ICSMA-25-072-01",
"discovery": "EXTERNAL"
},
"title": "Philips Intellispace Cardiovascular (ISCV) Use of Weak Credentials",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-2229",
"datePublished": "2025-03-13T18:17:31.256Z",
"dateReserved": "2025-03-11T20:11:49.638Z",
"dateUpdated": "2025-03-17T20:04:56.100Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2230 (GCVE-0-2025-2230)
Vulnerability from nvd – Published: 2025-03-13 18:14 – Updated: 2025-03-17 20:05
VLAI?
Summary
A flaw exists in the Windows login flow where an AuthContext token can
be exploited for replay attacks and authentication bypass.
Severity ?
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | Intellispace Cardiovascular (ISCV) |
Affected:
0 , ≤ 5.1
(custom)
|
Credits
Joe Dillon reported these vulnerabilities to Philips.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2230",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-13T19:33:45.514056Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T19:34:02.967Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intellispace Cardiovascular (ISCV)",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "5.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joe Dillon reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
}
],
"value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T20:05:56.939Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhilips recommends the following mitigations:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResolved in ISCV 5.2, which was released in September 2020.\u003c/span\u003e\n\n\u003c/li\u003e\n\n\u003cli\u003ePhilips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\u003c/li\u003e\n\u003cli\u003ePlease contact a local Philips sales (service) representative to learn how to engage this upgrade process.\u003c/li\u003e\n\u003cli\u003eFor managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eRefer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\"\u003ePhilips advisory\u003c/a\u003efor more details.\n\n\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Philips recommends the following mitigations:\n\n\n\n * \n\nResolved in ISCV 5.2, which was released in September 2020.\n\n\n\n\n * Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\n\n * Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n * For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
}
],
"source": {
"advisory": "ICSMA-25-072-01",
"discovery": "EXTERNAL"
},
"title": "Philips Intellispace Cardiovascular (ISCV) Improper Authentication",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-2230",
"datePublished": "2025-03-13T18:14:43.573Z",
"dateReserved": "2025-03-11T20:14:50.017Z",
"dateUpdated": "2025-03-17T20:05:56.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}