Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    310 vulnerabilities by Philips

    CVE-2026-3562 (GCVE-0-2026-3562)

    Vulnerability from nvd – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21
    VLAI
    Title
    Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability
    Summary
    Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3562",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:21:23.637688Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:21:33.688Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:57.414Z",
          "datePublic": "2026-03-06T21:19:44.813Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347: Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:37:09.162Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-160",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-160/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Viettel Cyber Security"
          },
          "title": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3562",
        "datePublished": "2026-03-13T20:37:09.162Z",
        "dateReserved": "2026-03-04T19:42:57.379Z",
        "dateUpdated": "2026-03-16T20:21:33.688Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3561 (GCVE-0-2026-3561)

    Vulnerability from nvd – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21
    VLAI
    Title
    Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3561",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:20:49.680668Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:21:04.470Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:53.455Z",
          "datePublic": "2026-03-06T21:19:38.258Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:37:05.625Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-159",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-159/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Thalium team from Thales Group (@thalium_team)"
          },
          "title": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3561",
        "datePublished": "2026-03-13T20:37:05.625Z",
        "dateReserved": "2026-03-04T19:42:53.419Z",
        "dateUpdated": "2026-03-16T20:21:04.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3560 (GCVE-0-2026-3560)

    Vulnerability from nvd – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:20
    VLAI
    Title
    Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3560",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:20:11.397148Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:20:23.327Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:49.535Z",
          "datePublic": "2026-03-06T21:19:32.778Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:37:01.412Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-158",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Xilokar (@xilokar@mamot.fr)"
          },
          "title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3560",
        "datePublished": "2026-03-13T20:37:01.412Z",
        "dateReserved": "2026-03-04T19:42:49.491Z",
        "dateUpdated": "2026-03-16T20:20:23.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3559 (GCVE-0-2026-3559)

    Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:19
    VLAI
    Title
    Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability
    Summary
    Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-323 - Reusing a Nonce, Key Pair in Encryption
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3559",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:19:38.659046Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:19:49.916Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:45.919Z",
          "datePublic": "2026-03-06T21:19:27.080Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-323",
                  "description": "CWE-323: Reusing a Nonce, Key Pair in Encryption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:57.441Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-157",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-157/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
          },
          "title": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3559",
        "datePublished": "2026-03-13T20:36:57.441Z",
        "dateReserved": "2026-03-04T19:42:45.880Z",
        "dateUpdated": "2026-03-16T20:19:49.916Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3558 (GCVE-0-2026-3558)

    Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:18
    VLAI
    Title
    Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability
    Summary
    Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3558",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:18:31.279335Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:18:40.959Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:42.421Z",
          "datePublic": "2026-03-06T21:19:21.476Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:52.519Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-156",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-156/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
          },
          "title": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3558",
        "datePublished": "2026-03-13T20:36:52.519Z",
        "dateReserved": "2026-03-04T19:42:42.383Z",
        "dateUpdated": "2026-03-16T20:18:40.959Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3557 (GCVE-0-2026-3557)

    Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17
    VLAI
    Title
    Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3557",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:17:45.866601Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:17:59.717Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:37.503Z",
          "datePublic": "2026-03-06T21:19:15.836Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:48.632Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-155",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-155/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Viettel Cyber Security"
          },
          "title": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3557",
        "datePublished": "2026-03-13T20:36:48.632Z",
        "dateReserved": "2026-03-04T19:42:37.457Z",
        "dateUpdated": "2026-03-16T20:17:59.717Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3556 (GCVE-0-2026-3556)

    Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17
    VLAI
    Title
    Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3556",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:16:52.038932Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:17:16.686Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:32.769Z",
          "datePublic": "2026-03-06T21:19:09.676Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:44.408Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-154",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-154/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "InnoEdge Labs"
          },
          "title": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3556",
        "datePublished": "2026-03-13T20:36:44.408Z",
        "dateReserved": "2026-03-04T19:42:32.733Z",
        "dateUpdated": "2026-03-16T20:17:16.686Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3555 (GCVE-0-2026-3555)

    Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:16
    VLAI
    Title
    Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process. The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3555",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:15:51.424960Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:16:14.612Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:29.193Z",
          "datePublic": "2026-03-06T21:19:00.069Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.\n\nThe specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:40.448Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-153",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-153/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Mehdi Talbi, Matthieu Breuil, Th\u00e9o Gordyjan from @Synacktiv"
          },
          "title": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3555",
        "datePublished": "2026-03-13T20:36:40.448Z",
        "dateReserved": "2026-03-04T19:42:29.133Z",
        "dateUpdated": "2026-03-16T20:16:14.612Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-27955 (GCVE-0-2025-27955)

    Vulnerability from nvd – Published: 2025-06-02 00:00 – Updated: 2025-06-11 15:27
    VLAI
    Summary
    Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-1259 - Improper Restriction of Security Token Assignment
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27955",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T16:07:36.398609Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-1259",
                    "description": "CWE-1259 Improper Restriction of Security Token Assignment",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T16:08:46.483Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T15:27:11.679Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/intruderlabs/cvex/tree/main/Carestream/session-token-in-url"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-27955",
        "datePublished": "2025-06-02T00:00:00.000Z",
        "dateReserved": "2025-03-11T00:00:00.000Z",
        "dateUpdated": "2025-06-11T15:27:11.679Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-27954 (GCVE-0-2025-27954)

    Vulnerability from nvd – Published: 2025-06-02 00:00 – Updated: 2025-06-11 15:27
    VLAI
    Summary
    An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27954",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T15:38:28.743684Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T15:43:08.823Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T15:27:08.776Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://portswigger.net/kb/issues/00500700_session-token-in-url"
            },
            {
              "url": "https://github.com/intruderlabs/cvex/tree/main/Carestream/session-token-in-url"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-27954",
        "datePublished": "2025-06-02T00:00:00.000Z",
        "dateReserved": "2025-03-11T00:00:00.000Z",
        "dateUpdated": "2025-06-11T15:27:08.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-27953 (GCVE-0-2025-27953)

    Vulnerability from nvd – Published: 2025-06-02 00:00 – Updated: 2025-06-11 15:27
    VLAI
    Summary
    An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27953",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-02T20:38:04.364005Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T13:05:14.652Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T15:27:10.253Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/intruderlabs/cvex/tree/main/Carestream/session-token-in-url"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-27953",
        "datePublished": "2025-06-02T00:00:00.000Z",
        "dateReserved": "2025-03-11T00:00:00.000Z",
        "dateUpdated": "2025-06-11T15:27:10.253Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3426 (GCVE-0-2025-3426)

    Vulnerability from nvd – Published: 2025-04-07 16:23 – Updated: 2025-04-10 15:40
    VLAI
    Title
    Use of default hardcoded credentials
    Summary
    We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities. Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt. This issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Date Public
    2025-04-07 16:05
    Credits
    Victor A Morales Omar A Crespo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3426",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-08T14:20:31.067496Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-08T16:01:23.914Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "IntelliSpace Portal",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "12 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "Advanced Visualization Workspace",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "15"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Victor A Morales"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Omar A Crespo"
            }
          ],
          "datePublic": "2025-04-07T16:05:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "We observed that Intellispace Portal binaries doesn\u2019t have any protection mechanisms to prevent reverse engineering. Specifically, the app\u2019s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.\u003cbr\u003eUtilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.\u003cbr\u003e\u003cp\u003eThis issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15.\u003c/p\u003e"
                }
              ],
              "value": "We observed that Intellispace Portal binaries doesn\u2019t have any protection mechanisms to prevent reverse engineering. Specifically, the app\u2019s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.\nUtilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.\nThis issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-188",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-188 Reverse Engineering"
                }
              ]
            },
            {
              "capecId": "CAPEC-65",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-65 Sniff Application Code"
                }
              ]
            },
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/S:P/AU:Y/R:U/V:C/RE:M/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-10T15:40:20.578Z",
            "orgId": "20705f08-db8b-4497-8f94-7eea62317651",
            "shortName": "Philips"
          },
          "references": [
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-3426"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html#security_advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Use of default hardcoded credentials",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20705f08-db8b-4497-8f94-7eea62317651",
        "assignerShortName": "Philips",
        "cveId": "CVE-2025-3426",
        "datePublished": "2025-04-07T16:23:00.325Z",
        "dateReserved": "2025-04-07T16:05:56.727Z",
        "dateUpdated": "2025-04-10T15:40:20.578Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3425 (GCVE-0-2025-3425)

    Vulnerability from nvd – Published: 2025-04-07 16:05 – Updated: 2025-04-10 15:41
    VLAI
    Title
    Unauthenticated Remote Code Execution via .NET Deserialization
    Summary
    The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. This issue affects IntelliSpace Portal: 12 and prior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Assigner
    Impacted products
    Vendor Product Version
    Philips IntelliSpace Portal Affected: 12 and prior
    Create a notification for this product.
    Date Public
    2025-04-07 15:36
    Credits
    Victor A Morales Omar A Crespo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3425",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-07T16:41:07.157306Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-07T16:41:18.426Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "IntelliSpace Portal",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "12 and prior"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Victor A Morales"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Omar A Crespo"
            }
          ],
          "datePublic": "2025-04-07T15:36:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. \u003cp\u003eThis issue affects IntelliSpace Portal: 12 and prior.\u003c/p\u003e"
                }
              ],
              "value": "The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. This issue affects IntelliSpace Portal: 12 and prior."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:Y/R:U/V:C/RE:M/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-10T15:41:29.106Z",
            "orgId": "20705f08-db8b-4497-8f94-7eea62317651",
            "shortName": "Philips"
          },
          "references": [
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-3425"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html#security_advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Unauthenticated Remote Code Execution via .NET Deserialization",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20705f08-db8b-4497-8f94-7eea62317651",
        "assignerShortName": "Philips",
        "cveId": "CVE-2025-3425",
        "datePublished": "2025-04-07T16:05:46.457Z",
        "dateReserved": "2025-04-07T15:37:15.413Z",
        "dateUpdated": "2025-04-10T15:41:29.106Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3424 (GCVE-0-2025-3424)

    Vulnerability from nvd – Published: 2025-04-07 15:36 – Updated: 2025-04-10 15:42
    VLAI
    Title
    3.2.1 Arbitrary File Read in insecure .NET Remoting TCP Channel
    Summary
    The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the "Object Marshalling" technique, which allows an attacker to read internal files without any authentication. This is possible by crafting specific .NET Remoting URLs derived from information enumerated in the client-side configuration files. This issue affects IntelliSpace Portal: 12 and prior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Philips IntelliSpace Portal Affected: 12 and prior
    Create a notification for this product.
    Date Public
    2025-04-07 15:05
    Credits
    Victor A Morales Omar A Crespo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3424",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-07T16:11:37.059479Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-07T16:11:44.627Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "filesystem"
              ],
              "platforms": [
                "Windows"
              ],
              "product": "IntelliSpace Portal",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "12 and prior"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Victor A Morales"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Omar A Crespo"
            }
          ],
          "datePublic": "2025-04-07T15:05:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe IntelliSpace portal application utilizes .NET\nRemoting for its functionality. The vulnerability arises from the exploitation\nof port 755 through the \"Object Marshalling\" technique, which allows\nan attacker to read internal files without any authentication. This is possible\nby crafting specific .NET Remoting URLs derived from information enumerated in\nthe client-side configuration files.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003eThis issue affects IntelliSpace Portal: 12 and prior.\u003c/p\u003e"
                }
              ],
              "value": "The IntelliSpace portal application utilizes .NET\nRemoting for its functionality. The vulnerability arises from the exploitation\nof port 755 through the \"Object Marshalling\" technique, which allows\nan attacker to read internal files without any authentication. This is possible\nby crafting specific .NET Remoting URLs derived from information enumerated in\nthe client-side configuration files.\n\n\n\n\n\n\n\nThis issue affects IntelliSpace Portal: 12 and prior."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:Y/R:U/V:C/RE:M/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-10T15:42:10.381Z",
            "orgId": "20705f08-db8b-4497-8f94-7eea62317651",
            "shortName": "Philips"
          },
          "references": [
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-3424"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html#security_advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "3.2.1 Arbitrary File Read in insecure .NET Remoting TCP Channel",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20705f08-db8b-4497-8f94-7eea62317651",
        "assignerShortName": "Philips",
        "cveId": "CVE-2025-3424",
        "datePublished": "2025-04-07T15:36:46.060Z",
        "dateReserved": "2025-04-07T15:05:10.307Z",
        "dateUpdated": "2025-04-10T15:42:10.381Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2230 (GCVE-0-2025-2230)

    Vulnerability from nvd – Published: 2025-03-13 18:14 – Updated: 2025-03-17 20:05
    VLAI
    Title
    Philips Intellispace Cardiovascular (ISCV) Improper Authentication
    Summary
    A flaw exists in the Windows login flow where an AuthContext token can be exploited for replay attacks and authentication bypass.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    Philips Intellispace Cardiovascular (ISCV) Affected: 0 , ≤ 5.1 (custom)
    Create a notification for this product.
    Credits
    Joe Dillon reported these vulnerabilities to Philips.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2230",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-13T19:33:45.514056Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-13T19:34:02.967Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intellispace Cardiovascular (ISCV)",
              "vendor": "Philips",
              "versions": [
                {
                  "lessThanOrEqual": "5.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Philips."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
                }
              ],
              "value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-17T20:05:56.939Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003ePhilips recommends the following mitigations:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResolved in ISCV 5.2, which was released in September 2020.\u003c/span\u003e\n\n\u003c/li\u003e\n\n\u003cli\u003ePhilips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\u003c/li\u003e\n\u003cli\u003ePlease contact a local Philips sales (service) representative to learn how to engage this upgrade process.\u003c/li\u003e\n\u003cli\u003eFor managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eRefer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\"\u003ePhilips advisory\u003c/a\u003efor more details.\n\n\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "Philips recommends the following mitigations:\n\n\n\n  *  \n\nResolved in ISCV 5.2, which was released in September 2020.\n\n\n\n\n  *  Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\n\n  *  Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n  *  For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the  Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-072-01",
            "discovery": "EXTERNAL"
          },
          "title": "Philips Intellispace Cardiovascular (ISCV) Improper Authentication",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-2230",
        "datePublished": "2025-03-13T18:14:43.573Z",
        "dateReserved": "2025-03-11T20:14:50.017Z",
        "dateUpdated": "2025-03-17T20:05:56.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-2229 (GCVE-0-2025-2229)

    Vulnerability from nvd – Published: 2025-03-13 18:17 – Updated: 2025-03-17 20:04
    VLAI
    Title
    Philips Intellispace Cardiovascular (ISCV) Use of Weak Credentials
    Summary
    A token is created using the username, current date/time, and a fixed AES-128 encryption key, which is the same across all installations.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Philips Intellispace Cardiovascular (ISCV) Affected: 0 , ≤ 4.1 (custom)
    Create a notification for this product.
    Credits
    Joe Dillon reported these vulnerabilities to Philips.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2229",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-13T19:30:31.475698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-13T19:30:42.059Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intellispace Cardiovascular (ISCV)",
              "vendor": "Philips",
              "versions": [
                {
                  "lessThanOrEqual": "4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Philips."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A token is created using the username, current date/time, and a fixed \nAES-128 encryption key, which is the same across all installations."
                }
              ],
              "value": "A token is created using the username, current date/time, and a fixed \nAES-128 encryption key, which is the same across all installations."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1391",
                  "description": "CWE-1391",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-17T20:04:56.100Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003ePhilips recommends the following mitigations:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResolved in ISCV 4.2 build 20589, which was released in May 2019.\u003c/span\u003e\n\n\u003c/li\u003e\n\n\u003cli\u003ePhilips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\u003c/li\u003e\n\u003cli\u003ePlease contact a local Philips sales (service) representative to learn how to engage this upgrade process.\u003c/li\u003e\n\u003cli\u003eFor managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eRefer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\"\u003ePhilips advisory\u003c/a\u003efor more details.\n\n\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "Philips recommends the following mitigations:\n\n\n\n  *  \n\nResolved in ISCV 4.2 build 20589, which was released in May 2019.\n\n\n\n\n  *  Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 \u2013 IntelliSpace \nCardiovacular 8.0.0.0)\n\n  *  Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n  *  For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the  Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-072-01",
            "discovery": "EXTERNAL"
          },
          "title": "Philips Intellispace Cardiovascular (ISCV) Use of Weak Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-2229",
        "datePublished": "2025-03-13T18:17:31.256Z",
        "dateReserved": "2025-03-11T20:11:49.638Z",
        "dateUpdated": "2025-03-17T20:04:56.100Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-3562 (GCVE-0-2026-3562)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21
    VLAI
    Title
    Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability
    Summary
    Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3562",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:21:23.637688Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:21:33.688Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:57.414Z",
          "datePublic": "2026-03-06T21:19:44.813Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347: Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:37:09.162Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-160",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-160/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Viettel Cyber Security"
          },
          "title": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3562",
        "datePublished": "2026-03-13T20:37:09.162Z",
        "dateReserved": "2026-03-04T19:42:57.379Z",
        "dateUpdated": "2026-03-16T20:21:33.688Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3561 (GCVE-0-2026-3561)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21
    VLAI
    Title
    Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3561",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:20:49.680668Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:21:04.470Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:53.455Z",
          "datePublic": "2026-03-06T21:19:38.258Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:37:05.625Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-159",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-159/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Thalium team from Thales Group (@thalium_team)"
          },
          "title": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3561",
        "datePublished": "2026-03-13T20:37:05.625Z",
        "dateReserved": "2026-03-04T19:42:53.419Z",
        "dateUpdated": "2026-03-16T20:21:04.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3560 (GCVE-0-2026-3560)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:20
    VLAI
    Title
    Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3560",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:20:11.397148Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:20:23.327Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:49.535Z",
          "datePublic": "2026-03-06T21:19:32.778Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:37:01.412Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-158",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Xilokar (@xilokar@mamot.fr)"
          },
          "title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3560",
        "datePublished": "2026-03-13T20:37:01.412Z",
        "dateReserved": "2026-03-04T19:42:49.491Z",
        "dateUpdated": "2026-03-16T20:20:23.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3559 (GCVE-0-2026-3559)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:19
    VLAI
    Title
    Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability
    Summary
    Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-323 - Reusing a Nonce, Key Pair in Encryption
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3559",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:19:38.659046Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:19:49.916Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:45.919Z",
          "datePublic": "2026-03-06T21:19:27.080Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-323",
                  "description": "CWE-323: Reusing a Nonce, Key Pair in Encryption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:57.441Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-157",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-157/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
          },
          "title": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3559",
        "datePublished": "2026-03-13T20:36:57.441Z",
        "dateReserved": "2026-03-04T19:42:45.880Z",
        "dateUpdated": "2026-03-16T20:19:49.916Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3558 (GCVE-0-2026-3558)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:18
    VLAI
    Title
    Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability
    Summary
    Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3558",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:18:31.279335Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:18:40.959Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:42.421Z",
          "datePublic": "2026-03-06T21:19:21.476Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:52.519Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-156",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-156/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
          },
          "title": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3558",
        "datePublished": "2026-03-13T20:36:52.519Z",
        "dateReserved": "2026-03-04T19:42:42.383Z",
        "dateUpdated": "2026-03-16T20:18:40.959Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3557 (GCVE-0-2026-3557)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17
    VLAI
    Title
    Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3557",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:17:45.866601Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:17:59.717Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:37.503Z",
          "datePublic": "2026-03-06T21:19:15.836Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:48.632Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-155",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-155/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Viettel Cyber Security"
          },
          "title": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3557",
        "datePublished": "2026-03-13T20:36:48.632Z",
        "dateReserved": "2026-03-04T19:42:37.457Z",
        "dateUpdated": "2026-03-16T20:17:59.717Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3556 (GCVE-0-2026-3556)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17
    VLAI
    Title
    Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3556",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:16:52.038932Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:17:16.686Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:32.769Z",
          "datePublic": "2026-03-06T21:19:09.676Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:44.408Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-154",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-154/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "InnoEdge Labs"
          },
          "title": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3556",
        "datePublished": "2026-03-13T20:36:44.408Z",
        "dateReserved": "2026-03-04T19:42:32.733Z",
        "dateUpdated": "2026-03-16T20:17:16.686Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-3555 (GCVE-0-2026-3555)

    Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:16
    VLAI
    Title
    Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability
    Summary
    Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process. The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    zdi
    References
    Impacted products
    Vendor Product Version
    Philips Hue Bridge Affected: 1.73.1973146020
    Create a notification for this product.
    Date Public
    2026-03-06 21:19
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3555",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-16T20:15:51.424960Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-16T20:16:14.612Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Hue Bridge",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.73.1973146020"
                }
              ]
            }
          ],
          "dateAssigned": "2026-03-04T19:42:29.193Z",
          "datePublic": "2026-03-06T21:19:00.069Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.\n\nThe specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T20:36:40.448Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-26-153",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-153/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "Mehdi Talbi, Matthieu Breuil, Th\u00e9o Gordyjan from @Synacktiv"
          },
          "title": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2026-3555",
        "datePublished": "2026-03-13T20:36:40.448Z",
        "dateReserved": "2026-03-04T19:42:29.133Z",
        "dateUpdated": "2026-03-16T20:16:14.612Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-27954 (GCVE-0-2025-27954)

    Vulnerability from cvelistv5 – Published: 2025-06-02 00:00 – Updated: 2025-06-11 15:27
    VLAI
    Summary
    An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27954",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T15:38:28.743684Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T15:43:08.823Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T15:27:08.776Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://portswigger.net/kb/issues/00500700_session-token-in-url"
            },
            {
              "url": "https://github.com/intruderlabs/cvex/tree/main/Carestream/session-token-in-url"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-27954",
        "datePublished": "2025-06-02T00:00:00.000Z",
        "dateReserved": "2025-03-11T00:00:00.000Z",
        "dateUpdated": "2025-06-11T15:27:08.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-27955 (GCVE-0-2025-27955)

    Vulnerability from cvelistv5 – Published: 2025-06-02 00:00 – Updated: 2025-06-11 15:27
    VLAI
    Summary
    Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-1259 - Improper Restriction of Security Token Assignment
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27955",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T16:07:36.398609Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-1259",
                    "description": "CWE-1259 Improper Restriction of Security Token Assignment",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T16:08:46.483Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T15:27:11.679Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/intruderlabs/cvex/tree/main/Carestream/session-token-in-url"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-27955",
        "datePublished": "2025-06-02T00:00:00.000Z",
        "dateReserved": "2025-03-11T00:00:00.000Z",
        "dateUpdated": "2025-06-11T15:27:11.679Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-27953 (GCVE-0-2025-27953)

    Vulnerability from cvelistv5 – Published: 2025-06-02 00:00 – Updated: 2025-06-11 15:27
    VLAI
    Summary
    An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27953",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-02T20:38:04.364005Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T13:05:14.652Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T15:27:10.253Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/intruderlabs/cvex/tree/main/Carestream/session-token-in-url"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-27953",
        "datePublished": "2025-06-02T00:00:00.000Z",
        "dateReserved": "2025-03-11T00:00:00.000Z",
        "dateUpdated": "2025-06-11T15:27:10.253Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3426 (GCVE-0-2025-3426)

    Vulnerability from cvelistv5 – Published: 2025-04-07 16:23 – Updated: 2025-04-10 15:40
    VLAI
    Title
    Use of default hardcoded credentials
    Summary
    We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities. Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt. This issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Date Public
    2025-04-07 16:05
    Credits
    Victor A Morales Omar A Crespo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3426",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-08T14:20:31.067496Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-08T16:01:23.914Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "IntelliSpace Portal",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "12 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "Advanced Visualization Workspace",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "15"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Victor A Morales"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Omar A Crespo"
            }
          ],
          "datePublic": "2025-04-07T16:05:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "We observed that Intellispace Portal binaries doesn\u2019t have any protection mechanisms to prevent reverse engineering. Specifically, the app\u2019s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.\u003cbr\u003eUtilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.\u003cbr\u003e\u003cp\u003eThis issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15.\u003c/p\u003e"
                }
              ],
              "value": "We observed that Intellispace Portal binaries doesn\u2019t have any protection mechanisms to prevent reverse engineering. Specifically, the app\u2019s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.\nUtilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.\nThis issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-188",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-188 Reverse Engineering"
                }
              ]
            },
            {
              "capecId": "CAPEC-65",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-65 Sniff Application Code"
                }
              ]
            },
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/S:P/AU:Y/R:U/V:C/RE:M/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-10T15:40:20.578Z",
            "orgId": "20705f08-db8b-4497-8f94-7eea62317651",
            "shortName": "Philips"
          },
          "references": [
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-3426"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html#security_advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Use of default hardcoded credentials",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20705f08-db8b-4497-8f94-7eea62317651",
        "assignerShortName": "Philips",
        "cveId": "CVE-2025-3426",
        "datePublished": "2025-04-07T16:23:00.325Z",
        "dateReserved": "2025-04-07T16:05:56.727Z",
        "dateUpdated": "2025-04-10T15:40:20.578Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3425 (GCVE-0-2025-3425)

    Vulnerability from cvelistv5 – Published: 2025-04-07 16:05 – Updated: 2025-04-10 15:41
    VLAI
    Title
    Unauthenticated Remote Code Execution via .NET Deserialization
    Summary
    The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. This issue affects IntelliSpace Portal: 12 and prior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Assigner
    Impacted products
    Vendor Product Version
    Philips IntelliSpace Portal Affected: 12 and prior
    Create a notification for this product.
    Date Public
    2025-04-07 15:36
    Credits
    Victor A Morales Omar A Crespo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3425",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-07T16:41:07.157306Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-07T16:41:18.426Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "IntelliSpace Portal",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "12 and prior"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Victor A Morales"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Omar A Crespo"
            }
          ],
          "datePublic": "2025-04-07T15:36:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. \u003cp\u003eThis issue affects IntelliSpace Portal: 12 and prior.\u003c/p\u003e"
                }
              ],
              "value": "The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. This issue affects IntelliSpace Portal: 12 and prior."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:Y/R:U/V:C/RE:M/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-10T15:41:29.106Z",
            "orgId": "20705f08-db8b-4497-8f94-7eea62317651",
            "shortName": "Philips"
          },
          "references": [
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-3425"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html#security_advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Unauthenticated Remote Code Execution via .NET Deserialization",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20705f08-db8b-4497-8f94-7eea62317651",
        "assignerShortName": "Philips",
        "cveId": "CVE-2025-3425",
        "datePublished": "2025-04-07T16:05:46.457Z",
        "dateReserved": "2025-04-07T15:37:15.413Z",
        "dateUpdated": "2025-04-10T15:41:29.106Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3424 (GCVE-0-2025-3424)

    Vulnerability from cvelistv5 – Published: 2025-04-07 15:36 – Updated: 2025-04-10 15:42
    VLAI
    Title
    3.2.1 Arbitrary File Read in insecure .NET Remoting TCP Channel
    Summary
    The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the "Object Marshalling" technique, which allows an attacker to read internal files without any authentication. This is possible by crafting specific .NET Remoting URLs derived from information enumerated in the client-side configuration files. This issue affects IntelliSpace Portal: 12 and prior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Philips IntelliSpace Portal Affected: 12 and prior
    Create a notification for this product.
    Date Public
    2025-04-07 15:05
    Credits
    Victor A Morales Omar A Crespo
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3424",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-07T16:11:37.059479Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-07T16:11:44.627Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "filesystem"
              ],
              "platforms": [
                "Windows"
              ],
              "product": "IntelliSpace Portal",
              "vendor": "Philips",
              "versions": [
                {
                  "status": "affected",
                  "version": "12 and prior"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Victor A Morales"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Omar A Crespo"
            }
          ],
          "datePublic": "2025-04-07T15:05:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe IntelliSpace portal application utilizes .NET\nRemoting for its functionality. The vulnerability arises from the exploitation\nof port 755 through the \"Object Marshalling\" technique, which allows\nan attacker to read internal files without any authentication. This is possible\nby crafting specific .NET Remoting URLs derived from information enumerated in\nthe client-side configuration files.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003eThis issue affects IntelliSpace Portal: 12 and prior.\u003c/p\u003e"
                }
              ],
              "value": "The IntelliSpace portal application utilizes .NET\nRemoting for its functionality. The vulnerability arises from the exploitation\nof port 755 through the \"Object Marshalling\" technique, which allows\nan attacker to read internal files without any authentication. This is possible\nby crafting specific .NET Remoting URLs derived from information enumerated in\nthe client-side configuration files.\n\n\n\n\n\n\n\nThis issue affects IntelliSpace Portal: 12 and prior."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:Y/R:U/V:C/RE:M/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-10T15:42:10.381Z",
            "orgId": "20705f08-db8b-4497-8f94-7eea62317651",
            "shortName": "Philips"
          },
          "references": [
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-3424"
            },
            {
              "url": "https://www.philips.com/a-w/security/security-advisories.html#security_advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "3.2.1 Arbitrary File Read in insecure .NET Remoting TCP Channel",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "20705f08-db8b-4497-8f94-7eea62317651",
        "assignerShortName": "Philips",
        "cveId": "CVE-2025-3424",
        "datePublished": "2025-04-07T15:36:46.060Z",
        "dateReserved": "2025-04-07T15:05:10.307Z",
        "dateUpdated": "2025-04-10T15:42:10.381Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }