CVE-2025-62765 (GCVE-0-2025-62765)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:27 – Updated: 2025-11-17 16:54
VLAI?
Summary
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-62765",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T16:54:52.076509Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T16:54:56.898Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:27:55.174Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-62765",
    "datePublished": "2025-11-14T23:27:55.174Z",
    "dateReserved": "2025-11-06T20:44:49.374Z",
    "dateUpdated": "2025-11-17T16:54:56.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-59780 (GCVE-0-2025-59780)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:26 – Updated: 2025-11-17 16:54
VLAI?
Summary
General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-59780",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T16:53:36.856914Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T16:54:08.683Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:26:35.691Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-59780",
    "datePublished": "2025-11-14T23:26:35.691Z",
    "dateReserved": "2025-11-06T20:44:49.360Z",
    "dateUpdated": "2025-11-17T16:54:08.683Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58083 (GCVE-0-2025-58083)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:24 – Updated: 2025-11-17 14:35
VLAI?
Summary
General Industrial Controls Lynx+ Gateway  is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58083",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:34:42.570290Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:35:13.251Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:24:54.274Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-58083",
    "datePublished": "2025-11-14T23:24:54.274Z",
    "dateReserved": "2025-11-06T20:44:49.352Z",
    "dateUpdated": "2025-11-17T14:35:13.251Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-55034 (GCVE-0-2025-55034)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:22 – Updated: 2025-11-17 14:53
VLAI?
Summary
General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55034",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:53:21.799019Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:53:32.111Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-521",
              "description": "CWE-521",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:22:29.031Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Weak Password Requirements",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-55034",
    "datePublished": "2025-11-14T23:22:29.031Z",
    "dateReserved": "2025-11-06T20:44:49.330Z",
    "dateUpdated": "2025-11-17T14:53:32.111Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-62765 (GCVE-0-2025-62765)

Vulnerability from nvd – Published: 2025-11-14 23:27 – Updated: 2025-11-17 16:54
VLAI?
Summary
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-62765",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T16:54:52.076509Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T16:54:56.898Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:27:55.174Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-62765",
    "datePublished": "2025-11-14T23:27:55.174Z",
    "dateReserved": "2025-11-06T20:44:49.374Z",
    "dateUpdated": "2025-11-17T16:54:56.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-59780 (GCVE-0-2025-59780)

Vulnerability from nvd – Published: 2025-11-14 23:26 – Updated: 2025-11-17 16:54
VLAI?
Summary
General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-59780",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T16:53:36.856914Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T16:54:08.683Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:26:35.691Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-59780",
    "datePublished": "2025-11-14T23:26:35.691Z",
    "dateReserved": "2025-11-06T20:44:49.360Z",
    "dateUpdated": "2025-11-17T16:54:08.683Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58083 (GCVE-0-2025-58083)

Vulnerability from nvd – Published: 2025-11-14 23:24 – Updated: 2025-11-17 14:35
VLAI?
Summary
General Industrial Controls Lynx+ Gateway  is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58083",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:34:42.570290Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:35:13.251Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:24:54.274Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-58083",
    "datePublished": "2025-11-14T23:24:54.274Z",
    "dateReserved": "2025-11-06T20:44:49.352Z",
    "dateUpdated": "2025-11-17T14:35:13.251Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-55034 (GCVE-0-2025-55034)

Vulnerability from nvd – Published: 2025-11-14 23:22 – Updated: 2025-11-17 14:53
VLAI?
Summary
General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55034",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:53:21.799019Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:53:32.111Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-521",
              "description": "CWE-521",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:22:29.031Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Weak Password Requirements",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-55034",
    "datePublished": "2025-11-14T23:22:29.031Z",
    "dateReserved": "2025-11-06T20:44:49.330Z",
    "dateUpdated": "2025-11-17T14:53:32.111Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}