Type a vendor name or a vulnerability id.



All the vulnerabilites related to Siemens - Mendix Applications using Mendix 9 (V9.12)
cve-2022-34466
Vulnerability from cvelistv5
Published
2022-07-12 10:07
Modified
2024-08-03 09:15
Severity
Summary
A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions >= V9.11 < V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.104Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V9.11 \u003c V9.15"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions \u003e= V9.11 \u003c V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:07:22",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34466",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V9.11 \u003c V9.15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions \u003e= V9.11 \u003c V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34466",
    "datePublished": "2022-07-12T10:07:22",
    "dateReserved": "2022-06-24T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.104Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-23835
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 10:42
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:42:27.044Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.34"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.23"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.22.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.18)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.18.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.15"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.34), Mendix Applications using Mendix 8 (All versions \u003c V8.18.23), Mendix Applications using Mendix 9 (All versions \u003c V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions \u003c V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.15). Some of the Mendix runtime API\u2019s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:58.910Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-23835",
    "datePublished": "2023-02-14T10:36:23.615Z",
    "dateReserved": "2023-01-18T10:28:31.589Z",
    "dateUpdated": "2024-08-02T10:42:27.044Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-31257
Vulnerability from cvelistv5
Published
2022-07-12 10:06
Modified
2024-08-03 07:11
Severity
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:11:39.898Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.31"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.18"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.14.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.2"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-31257",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.31"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.18"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.14.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-31257",
    "datePublished": "2022-07-12T10:06:43",
    "dateReserved": "2022-05-20T00:00:00",
    "dateUpdated": "2024-08-03T07:11:39.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}